Water Heater Blinking Error Code Reset Honeywell Valve

Поделиться
HTML-код
  • Опубликовано: 24 июл 2020
  • This is a method to help you try to reset your Honeywell gas valve on your water heater. In this particular instance it was a "7 blinks" (gas control failure) error code. However you can try this for several different codes and it might work for you. It is imperative that you get the water heater pilot flame lit and hold the (round) button in for at least 2 minutes because sometimes if you do not hold it in long enough -even if the controller starts blinking - and you let go of the (round) button; the thermopile can't generate enough power (millivolts) to generate the proper error codes.

Комментарии • 83

  • @FreonTheFrozen
    @FreonTheFrozen 3 года назад +14

    My Control Gas Valve did NOT reset to 1 blink or even less than 7. However since I was able to light the pilot and it did NOT turn off when I let go of the knob; I decided to turn the knob towards to "A" setting and the flame turned on! However it was still showing the 7 red light blinks, but after a minute or so it turned Blue! 🙌🙌 Hope this helps anybody else. Thanks for the video man, really saved me a headache.

  • @martinjaime9006
    @martinjaime9006 3 года назад +17

    Worked for me just now. From the off position turn to the pilot position and hold the button down while igniting the pilot. Once the pilot is lit continue to hold the knob down until you see the blue light blink. Once it’s back to blue you’re good to go.
    Thank you 👍🏽

  • @heavylifter6181
    @heavylifter6181 3 года назад +4

    Thank you Mike, I bought a new controller, hooked it up, turned it on and got 7 blinks right from the start. I was pissed and sure i got a bad controller. I saw your video, held the button for 3.5 minutes and it reset and now is working great. Thank you very much for sharing your knowledge and experience.

  • @tuanly7373
    @tuanly7373 3 года назад +8

    Thanks Mike. This worked for "5 blinks" too.

  • @mskim6562
    @mskim6562 3 года назад +2

    I am so glad I found this! We fixed it thanks to you!!!

  • @veritastruth9456
    @veritastruth9456 Год назад

    Houston freeze 2022! Boiler turned off and I was tripping ⚽️ 🏀 🏈 I’m glad you uploaded this video. Many many thanks. 🙏🏼

  • @jorgebetancourt4725
    @jorgebetancourt4725 3 года назад +3

    Worked for me, thanks Ruben.

  • @macjacfernandez6593
    @macjacfernandez6593 3 года назад +2

    Holy crap! Thank you so much Mike God Bless you man!

  • @nopointshorts5373
    @nopointshorts5373 2 года назад

    Thank you so much man I just purchase a new gas control valve and my luck I'd get another faulty one but seen this technique worked for everyone else I set a timer and help it and at the 3 min mark it turned blue and works perfectly thank you and happy new year !!!

  • @laurendavis8287
    @laurendavis8287 4 месяца назад

    Thank you thank you thank you! After getting the gas turned back on in my house, I was getting the 7 blinks. This completely fixed it!!!!

  • @kfduff
    @kfduff 8 месяцев назад +3

    If you don't have four or five minutes to wait, you can unplug the two leads that go into the thermostat, the light will blink for about 15 more seconds before dying out to nothing. Wait another 10 seconds. Plug the leads back in and it should be reset back to a single flash again.

    • @kfduff
      @kfduff 8 месяцев назад

      You will need to relight the pilot after performing this reset.

  • @Agapy8888
    @Agapy8888 Год назад

    Thanks so much. I saw the flashing light and didn’t know what it was. I checked it and it was flashing blue. From your recommendation I put it on A. It was on B. You helped a lot.

  • @jsheridan2793
    @jsheridan2793 3 года назад +5

    Thanks I was getting the 7 blink error too and couldn’t get it to light again . This worked it only took about 30 seconds for mine to reset .

  • @joynequawest2256
    @joynequawest2256 2 года назад

    Thank You so much!!! I had the 7 flash code, held the pilot button down and it worked in less than 3 mins. I then placed it on A it was on very hot previously.

  • @254zero
    @254zero 2 года назад

    Thank you very much. Worked in about 1.5 mins

  • @chadsimons2979
    @chadsimons2979 2 года назад +1

    Worked like a charm. Gotta you’re awesome thanks for saving my skin.

  • @CohenJeffrey
    @CohenJeffrey 3 года назад +3

    Dude! You just saved me several hundred bucks! I hadn't held it down long enough

  • @rafakatskiripz7652
    @rafakatskiripz7652 3 года назад +2

    A lot of help thanks man

  • @joonykim615
    @joonykim615 3 года назад +5

    Thanks Mike! The other video I saw was much more involved. I’m glad your simpler approach worked for the seven red blinks I was seeing. Very grateful you posted this.

  • @wandacruz5702
    @wandacruz5702 10 месяцев назад

    This worked for me, thank you so much!

  • @glowinggrave
    @glowinggrave 3 года назад +2

    Thank you. Was getting 7 blinks after I lit it. This reset it. Thank you so much again.

  • @papavictor3691
    @papavictor3691 Год назад

    Dang! I had lost hope but after seeing this video, I gave it a try. Shazaam! It worked! Thanks for posting this video.

  • @bravpadilla
    @bravpadilla 3 года назад +2

    Appreciate it worked on mine too

  • @ariaslauson5529
    @ariaslauson5529 3 года назад

    Thanks so much!

  • @danepane527
    @danepane527 Год назад

    Fixed my problem!

  • @joerose8538
    @joerose8538 3 года назад

    This worked for me thanks

  • @jamiesochin
    @jamiesochin 3 года назад +2

    I owe you a beer. Thanks.

  • @tfustudios
    @tfustudios 2 месяца назад

    Is your knob set to PILOT when you're pressing that down?

  • @JoeBlow-fe9rm
    @JoeBlow-fe9rm 2 года назад

    Life saver

  • @dannydelvalle2259
    @dannydelvalle2259 3 года назад

    I'll try it

  • @FullmoonEffects89
    @FullmoonEffects89 3 года назад +1

    Dam all the videos ive watched and see all the positive comments. Im jere the only one who cant fix mine.

  • @shelvinhodges2383
    @shelvinhodges2383 Год назад

    Yes it did

  • @mr.garcia8589
    @mr.garcia8589 3 года назад +1

    im replace new valve after that it game code 2 error thermocopile low voltage so i replace it it kept reading error 2 put a second new thermopile same thing error 2 after 30 sec valve pilot off.any tips on whats going on thanks for the advice

  • @lrh57psi
    @lrh57psi 2 года назад +1

    Maybe what we have to do is sue these manufacturer companies for being so reckless!

  • @michaelmcfeely6588
    @michaelmcfeely6588 3 года назад +2

    I am about to replace my 18-year-old water heater. I prefer the old reliable gas valve, not the new fancy electronic valve. I know not to put gasoline in the basement, so I have never had a fire or explosion. The new fancy valves will cost more and will be less reliable. This is not progress.

  • @MrCorbinsdad
    @MrCorbinsdad 2 года назад

    ?? Is it going to light while there is an error? The dial has to be on pilot for it to light. Are you holding it down while on "Pilot" ?

    • @MrCorbinsdad
      @MrCorbinsdad 2 года назад

      IT WORKED! My pre-RUclips search attempt to reignite the heater is what gave me the 7-blink code. I had dial on Pilot > Pressed ignite 5 - 7 times > rotated dial while keeping it pressed (out of frustration) and I heard it light up! I kept the dial pressed for about 30 seconds before I got a single steady blinking light.

  • @ValentineFamily1489
    @ValentineFamily1489 Год назад

    My rheem is blinking twice
    Sucks bc I can not afford for someone to look at it but I definitely need hot water but I’m literally having heart surgery in a couple weeks so I’m on medical leave with my job and they’re not paying me so I cannot afford. I have to do this on my own. I’m going down for my second attempt I didn’t hold it down for a couple minutes because I wanted to see what would happen but I’m going down to hold the button for 3 to 4 minutes to see if it will light and stay lit, wish me luck. I’ll come in again letting you know if it were. It worked the first time but then I didn’t hold it long enough. Thanks for the knowledge.

  • @DTA-me3kv
    @DTA-me3kv 2 года назад

    Will it work for a 5 blink sensor failure code

    • @michaelstroup8964
      @michaelstroup8964 2 года назад

      Someone from 10 months ago said it did, so I'm going to try this on mine tonight.

  • @georgegonzalez4399
    @georgegonzalez4399 3 года назад

    We got an ao smith 40 gallons. We qre gwtting 10 blinjs and the wayer is not heating up. My huaband tginks is tge dust?

    • @mikemorrison4860
      @mikemorrison4860  3 года назад

      I'm sorry but I'm not familiar with the 10 blink error code.

  • @adorablyadorable5665
    @adorablyadorable5665 2 года назад

    So you hold it down in position A?......Shouldn't you first turn it back to pilot?

    • @zosothehobbit
      @zosothehobbit 2 года назад

      No, you're correct. It should be held down in pilot. He said he just got it working before making the video, so I think he didn't want to turn it back down just to show the camera.
      I just now did this with it set to pilot, and it seems to be working, for now at least.

  • @6758BANDIT
    @6758BANDIT Год назад

    It helped me out !!! But I turned it off then tried to turn the pilot on & it worked the lite started blinking blue again ..

  • @ryanr6240
    @ryanr6240 2 года назад

    Just tried it and it worked, back to 1 flash. Let's see how long it stays. I set the knob to A.

    • @ryanr6240
      @ryanr6240 2 года назад

      Had to reset it again this weekend so it lasted only about a month. This I set it to just below the Hot setting.

    • @ryanr6240
      @ryanr6240 2 года назад

      3rd reset less than 2 weeks from the last one. Guess it's time for a replacement. I wonder if the replacement is an improved version or the same.

  • @justkang
    @justkang 3 года назад +1

    Our is flashing 9times. Error code says "chamber sensor failure". Any idea how to fix that??

    • @mikemorrison4860
      @mikemorrison4860  3 года назад

      Installing a new chamber sensor might work

    • @justkang
      @justkang 3 года назад

      @@mikemorrison4860 darn, I was hoping we could reset system and avoid that a replacement. Thanks!

    • @frank-qe7yt
      @frank-qe7yt 2 года назад

      mike morrison which one is the chamber sensor??? is that the temperature sensor or wich one any advise thanks mike for ur help

    • @frank-qe7yt
      @frank-qe7yt 2 года назад

      @Mike morrison

    • @itachisenpaix3
      @itachisenpaix3 2 года назад

      I'm having the same problem, any ideas on how to fix it?

  • @DTA-me3kv
    @DTA-me3kv 2 года назад

    Getting 5 blinks.. help..

  • @damaraewaldron7392
    @damaraewaldron7392 3 года назад +1

    Hold it down on pilot or A?

    • @mikemorrison4860
      @mikemorrison4860  3 года назад +2

      You can't push it in on "A". You can only push it in when it's in the pilot position. Give it a try you'll see what I mean.

  • @justdissin7340
    @justdissin7340 3 года назад

    I got a hydraulic system so its gotta be up all the way

  • @binine_s
    @binine_s 2 года назад

    Hello . Could you please describe each error code?

    • @mikemorrison4860
      @mikemorrison4860  2 года назад

      Unfortunately there are different controllers with different error codes. The error codes are printed on the controller or sometimes on a label on the water heater. If it's not on the controller look for a label up there about the middle section of the water heater.

  • @andrealynn1314
    @andrealynn1314 3 года назад

    Help. My pilot lights... but tank wont blink or fire up

    • @mikemorrison4860
      @mikemorrison4860  3 года назад +1

      Does the pilot light stay lit when you let go of the button or does it go out as soon as you let go of the button?

    • @andrealynn1314
      @andrealynn1314 3 года назад

      @@mikemorrison4860 it goes out...

    • @andrealynn1314
      @andrealynn1314 3 года назад

      @@mikemorrison4860 we did it last year (for my parents at their cottage) but cant figure it out for the life of me! I know I just did it last year.

  • @lxlspooky__
    @lxlspooky__ 3 года назад

    what if your scared that gas will drop?

    • @yeahthatshouldwork
      @yeahthatshouldwork 3 года назад +2

      Then have you wife do it for you

    • @dntlss
      @dntlss 3 года назад

      @@yeahthatshouldwork lol

  • @Bigbabby68
    @Bigbabby68 3 года назад +1

    What about a 5 blink code

    • @mikemorrison4860
      @mikemorrison4860  3 года назад +1

      What does it say on the controller that five blinks means?

    • @DTA-me3kv
      @DTA-me3kv 2 года назад +1

      @@mikemorrison4860 IT SAYS SENSOR FAILURE WILL IT WORK?

    • @DTA-me3kv
      @DTA-me3kv 2 года назад +1

      @@mikemorrison4860 any answer would be appreciated

    • @DTA-me3kv
      @DTA-me3kv 2 года назад

      The 5 blink code

  • @salcee1750
    @salcee1750 3 года назад

    My pilot lit but the light never blinked and I held it down for 8 minutes. Released and it turned off? 🥴

    • @mikemorrison4860
      @mikemorrison4860  3 года назад +1

      Your thermocouple (thermopile) is BAD. Or one or more of the contacts on the board is bad.