2 Services, under 11 minutes!
HTML-код
- Опубликовано: 16 май 2024
- How to strip service a @WorcesterBoschHeating CDi and a brand new @WorcesterBoschHeating 8000 with the hidden tip on turning off Worcester siphon fill mode!
This is especially useful for apprentices and new starters!
Thanks for watching!!
There’s been a few requests on where I get the ‘Fluezy’ adapters from - eightbitgho... - www.ebay.co.uk/usr/eightbitghost
Don’t forget to like and subscribe please 🙏🏽❤️
#boiler #worcester #centralheating #heating #leak #fan #damage #education #multimeter #wiring #repair #repaircosts #plumbing #gassafe #gas #boilerservicing #boilerservice #boiler #boilerfix
11 minutes that's fast money. Nice and easy access
Haha, if only!
Great video and cheers for the shout out mate ❤
You come with those new age tools 😂 thanks bro!
Hi RJ Heating, cool vids, but I would replace the electrode gasket and door seal always!
Also, a flue integrity test (air intake) is pointless with the case off!
Just a couple of tips.
I’m not digging you out mate, just a few pointers 👌👍
You’re right on the flue integrity, and the test was done with the case back on after - cards on the table, I’m new to filming and sometimes it throws you off or you don’t manage to film everything or gets cut in the edit etc - but lesson for me to at least update the description.
Personally, I only replace the gaskets on the electrode and burner door if required - again, probably should have showed the testing.
Thank you for watching anyway, hope to see you back in the future!
Nice one buddy! What's ebay shop for those air intake adapters? Cheers
Thanks Alan! Appreciate you watching. His name is @eightbitghost on instagram or www.ebay.co.uk/usr/eightbitghost
That was a top short and sweet video. ❤. That was very informative. What was them angle bits for the flue called again? Thanks
Thanks Arif! Appreciate that! They’re called Fluezy from @eightbitghost906 or @eightbitghost on instagram and eBay! He’s a great guy with some really helpful products, especially for tight spaces!
www.ebay.co.uk/usr/eightbitghost
@@RJHeating thanks man appreciate that❤️👍
@@user-li8gr8ur8l no problem! Grab the drain down keys whilst you’re there too 😂
@@RJHeating yes most definitely . First thing that caught my attention🤣❤️
Did you take the burner out and check the barring platt
Burner had a visual when taking the electrodes out to check. Not sure why you’d be checking the bearing plate - it’s not a serviceable part and you’ll soon know if it’s sticking. Rumour has it, it’s not actually required and only necessary in really cold climates like
Some European countries.
FGA checks will also highlight any issues with burner. Thanks for watching anyway
@@RJHeating I change the top burner seal after 4 years on a full strip down and have a look at the barring platt to see if it's ok