Drain height shower pan. Bonding flange

Поделиться
HTML-код
  • Опубликовано: 15 янв 2025

Комментарии • 35

  • @rideauviewconstruction717
    @rideauviewconstruction717 Год назад +8

    Forever grateful for Sal’s videos. Helped me establish skills needed for building showers and tile work. No failures since starting up in 2009.

    • @SalDiBlasi
      @SalDiBlasi  Год назад +1

      Thanks, glad it helped

    • @TILEROB
      @TILEROB Год назад +1

      Ya he git a good channel

  • @billyc5010
    @billyc5010 Год назад +4

    I've watched probably every single video of Sal building a mud pan, it never gets old watching the best in the business effortlessly build another perfect project. Thank you Sal for continuing to share your expert knowledge with us.

  • @323floors2
    @323floors2 Год назад +9

    You seem to be the one guy who cares more for the industry than he does being an influencer.

  • @chengsu6499
    @chengsu6499 10 месяцев назад +1

    The hole on the subfloor is much bigger than flofx flange drain outlet, so there is a gap between the outlet and the edge of the hole. Do you fill the gap up? Or will the gap cause mud bed movement in future?

  • @ismaelcarrerojr7124
    @ismaelcarrerojr7124 Год назад +2

    Hey Sal what type of screws you used to hold down flange? Thank you again.

    • @SalDiBlasi
      @SalDiBlasi  Год назад +2

      They are laticrete screws, the head is a bit smaller than the durock screws.

    • @ismaelcarrerojr7124
      @ismaelcarrerojr7124 Год назад +1

      @@SalDiBlasi thank you for your quick response

  • @travisk5589
    @travisk5589 11 месяцев назад +2

    Sal, level those from diagonal corner to corner, it will be faster

  • @ohokayofficial
    @ohokayofficial Год назад +1

    3 bathrooms I’ve been to so far (this month) have had their drains situated flush with the wooden subfloor..
    Any tips for what to do in prefloat situations - can you still prefloat or does the drain have to be redone?

    • @SalDiBlasi
      @SalDiBlasi  11 месяцев назад +2

      I am guessing those were two stage drains, not a bonding flange type like the ones I use. They should have a preslope, liner and then final mud bed. Bonding flange has a single mud bed.

  • @Paul-rg4is
    @Paul-rg4is Год назад +1

    What material is on those walls? Are you putting sheet membrane over that?

    • @SalDiBlasi
      @SalDiBlasi  Год назад +2

      New waterproof board, not available just yet.

  • @TILEROB
    @TILEROB Год назад +1

    Good video

  • @thomasrose6629
    @thomasrose6629 Год назад +1

    Do you have anything against slurry coating the floor before the mud instead of tar paper/wire when you’re waterproofing it anyways? Or is just a personal preference?

    • @SalDiBlasi
      @SalDiBlasi  Год назад +1

      Supposed to be an unbonded mud bed on plywood, bonded on concrete.

    • @Losas.Company
      @Losas.Company 11 месяцев назад

      @@SalDiBlasithe drypack youre using, where from? What brand?

  • @skdrcr
    @skdrcr Год назад +1

    Appreciate you Sal for making this video. Is your target drain height 1 1/4 in? What if you were on a concrete floor, would the height be less?

    • @SalDiBlasi
      @SalDiBlasi  11 месяцев назад +2

      Usually the same, but depending on the type of mud, could be less.

  • @ryankelley85091
    @ryankelley85091 11 месяцев назад

    What's the minimum mud depth under the drain flange if working on single sheet of plywood sub-floor? I'm trying to go curbless. I have 1.5 inches of difference between the shower and the rest of the bathroom floor. The shower 72 x 38 inches, which gives me about 32 inches the long way to each wall from the edge of the drain flange. That would put me right at 1/4 slope per foot if the top of the flange is 3/4 inches off the floor. I'd have to go less than 3/4 inches of mud under the flange to make this work.

    • @TsiRoadkill
      @TsiRoadkill 7 месяцев назад +1

      You want a inch of mud there but you could get away with like 7/8 and 1/8 per foot slope

  • @BonBon770
    @BonBon770 Год назад

    Good video! I always tape off my bottom piece with duct tape and cut it really nice to keep all the mud away from the drain. should that be done with bonding flamges to keep the mud off of the actual felt until you're ready to connect the actual membrane to it? And if so, which tape would you use?

  • @WadeMD
    @WadeMD 11 месяцев назад

    Sal, im a DIYer. I see that you use multiple different systems, kerdi, latticrete. What would you recommend as the easiest system? I’m planning on doing a mud base slope to my drain and waterproofing and then tiling.

  • @ajrotko
    @ajrotko 10 месяцев назад

    Do you do anything to prevent mud from going in the hole of the subfloor?

    • @SalDiBlasi
      @SalDiBlasi  10 месяцев назад

      If the hole is the correct size, it's not a problem

  • @jodavis1981
    @jodavis1981 9 месяцев назад

    Sal I see screws in your cement board lower than three inches above floor, is that ok? I always hear people say dont embed screws in mud bed. Your thoughts?

    • @SalDiBlasi
      @SalDiBlasi  9 месяцев назад

      This is a bonded system has no effect on waterproofing.

  • @felixcarrillo1528
    @felixcarrillo1528 8 месяцев назад

    I think this drain is good but it needs a hair cather like Ebbe drains, also the finish grout around the drain is prety thick or wider than the grout on the tiles

  • @erikleibbrand9648
    @erikleibbrand9648 11 месяцев назад

    Hello. I know it's overkill, but could I theoretically put a oatey pvc pan liner in and then put a membrane over the mudbed, if i could find the right parts to fit togather?