Carrier 58 Series ECM Blower Motor Replacement
HTML-код
- Опубликовано: 31 авг 2023
- Help Support My Son Logan To Beat His Cancer.
GoFund Me
gofund.me/9deb66a2
Venmo & Zelle. jfeger4@att.net
Amazon Wish List Link
www.amazon.com/hz/wishlist/ls...
www.amazon.com/shop/miheatingguy
NU CALGON 4774-0 Coil Gun Sprayer With Quick Connect Hose Nozzle
amzn.to/39PxGya
Nu-Calgon 4291-08 Nu-Brite
amzn.to/3u6yN3x
Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light
amzn.to/3pe2hYH
Milwaukee M12 Surge Hydraulic Driver Kit 2551-22
amzn.to/3n5offb
Makita E-01563 Impact XPS 3 Pc. 6" Magnetic Nut setter Set
amzn.to/2JdAcku
Milwaukee 48-22-6330 Tongue and Groove Pliers Set
amzn.to/3kfch0R
GoPro Hero 8 Black Action Camera with Accessory Bundle
amzn.to/34AGamf
Veto Pro Pac Tech XL Tool Bag
amzn.to/2U1QqPF
OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
amzn.to/370rGiq
Amprobe AMP-320 Clamp Meter
amzn.to/2GNxUHe
Fluke 117 Electricians True RMS Multimeter
amzn.to/3iFZP9t
Milwaukee 2364-20 M12 Rover
amzn.to/2HNvitK
Milwaukee Rocket light 2132-20
amzn.to/341OTPm
#MIHeatingGuy
#MichiganHeatingGuy Хобби
Always nice to make your own diagnosis. Nothing on those Carrier units are inexpensive . Those motors, boards and inducer motors are crazy expensive. Nice second opinion on the motor. That confirmation tool is pretty cool.👍👍🇨🇦
Great troubleshooting. That's what I was always the best at. Actual repair, that was hit or miss with me. It always frustrated me, that after I told another tech the exact steps I followed, it never seemed to matter, they would go through the same steps. But, I can understand it. It's easy to miss some subtlety when troubleshooting electronics.
The mounting bracket for the motor reminds me of the old school Christmas tree stands.
I ran into a lot of those Carrier 90+ furnaces with bad primary heat exchangers because the installers never changed the heating cycle rate on the thermostat to 3 cycles per hour from the factory default setting of 6 cycles per hour. The short cycles would not allow enough run time to get the heat exchanger up to temperature and resulted in flue gases condensing in the primary instead of the secondary one. The condensed flue gases would rust out the primary after 4 or 5 years. 6 cph was okay for 80+ furnaces.
6cph is ridiculous for any furnace.
Nice just learned about ecms today in class great to see what it’s about before we get into the labs
You showed a lot of common sense & common courtesy today Joe... neither of those qualities are very common these days.
on propane, should have just changed the furnace and done a heatpump at the same time. doubt the new secondary will last on propane.
Looks like it’s cold in Michigan
👍👍
👍👍👍🔥🔥
That heat inducer motor sounded like crap, they always sound that way?