Deli case not cooling

Поделиться
HTML-код
  • Опубликовано: 1 апр 2018
  • Found a deli case running high head high suction psi.
  • ХоббиХобби

Комментарии • 84

  • @mariomorua8937
    @mariomorua8937 6 лет назад +4

    Dude, when I was green and was diagnosing a deli display case. I was taking the whole case apart looking for evap fans. Once I was done taking everything apart and found no fans, I stopped and thought things through and figured out this damn thing cools with no fans. So there I went putting everything back together. It was sink or swim for me when I first started as technician, my supervisor was no help as he didn’t know much either, but was kept with the company because he is a good brown noser.

  • @Gears.and.Gadgets
    @Gears.and.Gadgets 6 лет назад +14

    Good video Dave. I've seen one of my coworkers a bit less experienced. Try to add refrigerant to the True static coil one we have. He said the pressure on the low side was low. I told him to stop, and think, you are working witha static evaporator. I also told him to gauge up on both sides of the unit, not on just one. He found the head pressure was at 275 PSI. I asked him if the condenser coil was clean. He said it looked clean. I asked him to shine a bright light through it. He said he could not see light from the other side. I just told him to clean the condenser coil throughly. He told me he could not believe how dirty it was. I asked him what his final pressures were. Low side 10.5 PSI. High side 110 PSI.

  • @tcphvacr9950
    @tcphvacr9950 6 лет назад +14

    You mean it won’t cool three times as good with more refrigerant? Well I’ll be damned. Good vid, Dave.

    • @NorCal-refrigeration
      @NorCal-refrigeration  6 лет назад

      tcpHVAC/R 😂😂😂

    • @davidhoward2237
      @davidhoward2237 6 лет назад

      im uncle who pass away had a thing about tell people to over charge it. in the old days did it make any differnt or just screw them up?

  • @bblazeff1
    @bblazeff1 6 лет назад +4

    I 💖 when the customers have a case warm still selling product, usually just as warm as the air temp. Some of the Aldi stores in my area that I service do the same thing, selling soft ice cream and warm deli meats when a case is down. 😃

  • @scottriddle5468
    @scottriddle5468 6 лет назад +3

    Man I'm new to the static coil type deli case , im glad you posted this Dave . Now I will not be shocked when I run across this beast in the field. Tkx bro

  • @FishingwithNieves
    @FishingwithNieves 10 месяцев назад

    You need to do more videos like this man,they really helps Dave.❤️🔥👍

  • @philltafolla
    @philltafolla 6 лет назад +6

    Great Video Dave In my short career ,I’ve came across dudes with 10+ years experience that have done exactly what you’ve just showed in this video . I was working on a single door True freezer TUC 27 I believe, unit was a 134a I show up unit was at 28-32 degrees I gauge it up 22psig suction and 190 or so on the head pressure . I recovered the charge unit had about 11/2 pounds of refrigerant . I asked the dude how did you charge it he said well R134 A you need to be at a 20degree evap so that’s what I did . I was like wow . That unit only took a factory charge of 8ozs on startup I had about a 18-20 suction and about a 175-180 head as the box started cooling head pressure dropped as well as my suction pressure . I told the dude as the box starts reaching temp your suction pressure will drop . When your close to set point you will have between 8-12psig on your suction, needs to learn how to use a pt chart and understand pressure and temperature. Again I just wanted to share that with you Mr. Expert 🤫😎

    • @squirtlehvac8962
      @squirtlehvac8962 6 лет назад +1

      Felipe Tafolla couldn’t he have weighed in the charge?

    • @philltafolla
      @philltafolla 6 лет назад

      Squirtle Hvac yes thats what he should of done since the beginning but he didn’t

    • @Izzy-qj8zn
      @Izzy-qj8zn Год назад

      I I w. Msx

  • @apprenticephil649
    @apprenticephil649 6 лет назад +2

    That poor compressor! Good call with the reclaim. I've had the luck of servicing these cases quite a few times. They can be tricky if they are in high ambient or workers leave the doors open because they really ice up. Good lesson showing the suction range and temp.

  • @Cscrefandhvac
    @Cscrefandhvac 6 лет назад +1

    Great video Dave , it’s good you showed this. I used to work on a lot of cases like this years ago but not as many around now. Definetly good for the younger guys to see this that may not see these cases to often

  • @fedboy601
    @fedboy601 6 лет назад +2

    Mane thanks so much for your videos. I have only been doing this 5 years and your videos help me learn the refrigeration side of things .

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 6 лет назад +2

    I always do a critical charge. I never heard anyone charging by super cool or subheat on a cooler or refrigerator. Nice video thank you

    • @sivalley
      @sivalley 6 лет назад

      Ron White ya got me. 😂😂😂

  • @randomrefrigeration4564
    @randomrefrigeration4564 6 лет назад +9

    freon goes in the low side and payday is on friday and if all else fails add more freon lol

  • @RealityRenovations
    @RealityRenovations 6 лет назад +1

    I can see why someone would make that mistake if they dont know what they're looking at. At first glance it does scream low charge. Great video, very helpful for non refer guys!

  • @nsboost
    @nsboost 6 лет назад +2

    Bro I would kill to be able to shadow you for six months. Thanks for the videos. They help a ton

  • @reyrodriguez1005
    @reyrodriguez1005 4 года назад

    i recently discovered your channel Dave, and im glad there is so much available content! For 3 weeks ive been sitting on the couch watching your videos on my downtime. Salud from Bakersfield, Ca!

  • @joeshearer1247
    @joeshearer1247 6 лет назад +1

    You are the only other youtuber I know that changes drier every chance. N nice work

  • @natebelden8915
    @natebelden8915 6 лет назад +3

    Your vids rock! I am just getting done with school for hvac! I would love to find someone like you to learn from in the field. Plus to live where you do!! Dang bro you got it made!!

    • @superoxidedismutor
      @superoxidedismutor 6 лет назад +1

      nate belden best thing that could happen to you, my mentor is also named Dave and he's just like him a well of know-how and knowledge, after learning with him for a bit more than a year and a half (from scratch, but I did a whoooole lot of info digging in my spare time too, I did a bit of installs with a guy who's like these two but on the installs side of the job, I learned a lot from him too) I was alone on the road with a van doing repairs, even though I'm operational I'm still miiiles away from Dave and Dave lol

    • @natebelden8915
      @natebelden8915 6 лет назад

      Yes I am in Wisconsin but I would move just about anywhere to get a mentor or trainer like Dave!

  • @mccutcheonservicesllc81
    @mccutcheonservicesllc81 6 лет назад +1

    Great video and advice!! It happens way too often 👍

  • @duncansappliancerepair2141
    @duncansappliancerepair2141 6 лет назад +2

    Great Dave keep the videos coming 👍🏻

  • @gene-khvacr
    @gene-khvacr 6 лет назад +1

    Cool basic keep it simple diagnostic old school good job 👍👍👍did it like a boss 😎😁

  • @HVACRDUDE
    @HVACRDUDE 6 лет назад +2

    AND ANOTHER GREAT VIDEO 👍 THANKS BUDDY!

  • @robertgaitskell7212
    @robertgaitskell7212 5 лет назад

    Great video Dave you should always way gas coming out, great for diagnostics, I have found many units overcharged over the years.

  • @ComfortPlusHeatingandCooling
    @ComfortPlusHeatingandCooling 6 лет назад +1

    Nice Job Dave!

  • @advancedbasher
    @advancedbasher 3 года назад

    I ran a crossed a Similar unit to day. Some times I think they look at Test pressures and charge to that... lol Great one again. Factory charge.

  • @crforfreedom7407
    @crforfreedom7407 5 лет назад

    I'm new to this game, and when I first saw you evacuate a system to weigh the charge instead of determining +/- amounts from SH or SC, I thought you were being a bit extreme and over the top. Not now. I think this is the best example there is on how the importance of system weight and what the reintroduction of spec weight can do in ensuring a properly running system, and saving time in the long run. Perhaps minor tweaking with gas notwithstanding.
    And with leaks always a concern on an older, 1st time worked on or in a while unit (by my mits anyway), I would imagine it's a good way to know if it has a leak to be found as well? Great resource all around. Thanks for sharing your knowledge and experience with us new guys! It's always nice to NOT have to re-invent the wheel!!!!

  • @gr82becool
    @gr82becool 6 лет назад +1

    That was a good video, 👍🍻

  • @74womack
    @74womack 6 лет назад

    Another good one keep em coming bro.

  • @JMills-28457
    @JMills-28457 6 лет назад

    Who would thumbs down that video? Probably the guy that overcharged it to begin with. Great video

  • @mikestevenson1819
    @mikestevenson1819 6 лет назад +2

    Awesome!

  • @aircooledtx
    @aircooledtx 6 лет назад

    OC is common on reach-in like that one. Racetrack, Stop-Quik stores here. Good recovery /recharge Dave

  • @davidpetersen4290
    @davidpetersen4290 6 лет назад

    That's nice I've never worked on a static coil unit

  • @capitolrefrigerationheatin7501
    @capitolrefrigerationheatin7501 6 лет назад +3

    free r 134, thats always a good day

  • @kidalwys
    @kidalwys 5 лет назад

    That’s a great video.

  • @Tgriff209
    @Tgriff209 6 лет назад +1

    Love this RUclips account. What are some other good refrigeration accounts? Not hvac

    • @NorCal-refrigeration
      @NorCal-refrigeration  6 лет назад

      tommy griffin csc refer and HVAC guy. Good stuff. HVACR videos also

  • @HVACRDUDE
    @HVACRDUDE 6 лет назад +2

    Hey Dave, Have you ever tried taking both cores out and using the 3/8" hoses with the 1/4" fitting for evacuation? Its INSANE HOW FAST IT IS!!!!

  • @hvacgabe5889
    @hvacgabe5889 6 лет назад

    Good video dave. Great Tip on the static coil. So how long of a defrost time is normal on static coils?

    • @NorCal-refrigeration
      @NorCal-refrigeration  6 лет назад

      gabriel brown I like 120 min at night. I’ve seen 2-90 min defrosts also.

  • @JeWfRo815
    @JeWfRo815 6 лет назад

    Great video. What’s your desired operating temperature in that case? Mid 30s??

  • @williamloper9260
    @williamloper9260 6 лет назад +1

    Just a little to much Gas Ha Ha Crazy ! I also run into this a lot with 134a systems Good advise just recover right away and weigh in and stop the guess work

  • @bradmironik6137
    @bradmironik6137 6 лет назад

    Good video. When you recovered the charge how do you know if the refrigerant is good to reuse. Do you pull a vacuum on the tank so the charge can be reused? Thanks.

  • @danielchappell9355
    @danielchappell9355 Год назад

    Thanks Dave, working on a static coil fish display case. What evaporator coil temperature should be for this?

  • @superoxidedismutor
    @superoxidedismutor 6 лет назад +1

    When there's no sticker with the charge, stay safe, some of these static machines evaporate at -20°C (-4°F) (, be careful and don't go for a -5°C (23°F) right away, I've blown a compressor doing that (not the only problem, there was an oil plug in the condenser and lots of acidity due to previously burned compressor stator windings but still, main was burned, start wasn't, which means HP too high, the oil in the condenser coil didn't help, maybe the oil was pushed in the discharge by liquid flooding back due to excess charge)).
    Refer to the high side pressure aswell, and if there's no valve on the high side, don't be afraid to solder a schrader, a new schrader and 30min soldering it will still cost less than a compressor and 2h replacing it on warranty.
    And if you have any slightest doubt, change the effin dehydrating filter.

    • @superoxidedismutor
      @superoxidedismutor 6 лет назад

      Well even without the shadow of a doubt, change the filter anytime you add or replace anything on the circuit

  • @primetime758
    @primetime758 5 лет назад

    reminds a few yrs back for a Japanese restaurant he had a 6ft display case for some who knows what lol... i got there .. compressor was done for... it had 5 pounds of Freon in it i said did someone else come here and fiddle with this .. he said yes a family member.. ... sheesh but this case had another problem there was zero Air circulation he didn't want me to cut the bottom front to put a grill there was no chance to install water cooled he has a basement just not under that side of the restaurant i ended up pulling the pipe above the ceiling he called a carpenter to cover my pipes ... ran the pipe above the ceiling than as soon as i knew i was above the basement i ran it down

  • @harrydickson4575
    @harrydickson4575 6 лет назад +1

    👍👍👍

  • @nocompeterefrigerationserv7501
    @nocompeterefrigerationserv7501 6 лет назад +2

    👍🤘🤘💰💰

  • @superoxidedismutor
    @superoxidedismutor 6 лет назад +1

    Now that I think about it lp: 30psi and hp 250 psi would be ok on the same case if the case was running r404a. Thought about wrong gas but since you put the gas you recuperated back in the circuit if it were r404a, at 150psi it would condense at 70°F which wouldn't work at all. So coincidence I guess.

  • @jeremyvoshage2410
    @jeremyvoshage2410 6 лет назад

    Dave, What length and duration do you like on this static boxes?

  • @andygalindo8978
    @andygalindo8978 6 лет назад

    Your the master. I’m not worthy.

  • @averagebloke4474
    @averagebloke4474 6 лет назад

    Wish I can learn refrigeration. Maybe someday.

  • @ianpalmer1482
    @ianpalmer1482 6 лет назад

    Hey Dave did you get hit with the earthquake? I hope everything is going well.

  • @syedbasheer8210
    @syedbasheer8210 4 года назад

    🙏

  • @joeheritage
    @joeheritage 6 лет назад +3

    Nice work Dave. Would you suspect a leak if someone was adding gas? Maybe do a nitro check after recovery?

  • @MotivativeThinking2
    @MotivativeThinking2 6 лет назад

    Slugging the crap out of that compressor!

  • @marinobravo1
    @marinobravo1 6 лет назад

    I wonder what made the previous "tech" juice it up so much

    • @NorCal-refrigeration
      @NorCal-refrigeration  6 лет назад

      marino lack of knowledge of the static coil system. It boned us all myself included

  • @romanadriel2877
    @romanadriel2877 4 года назад

    Why would they have added gas? Did the owner call a different company because no cool condition? They probably added gas it started cooling, then quit again because an overcharge. Makes me think there may have been a restriction or contamination. Don't mind me I'm just a rookie who over thinks thanks for the video.

    • @NorCal-refrigeration
      @NorCal-refrigeration  4 года назад

      Roman Adriel we all over think every job we are HVAC/R techs. Lol

  • @josuealvrado6348
    @josuealvrado6348 3 года назад

    How do you read the psi on the high side of it doesn’t read R134a?

  • @jonhvac
    @jonhvac 6 лет назад +4

    Moe gas is always moe better...don't u no nothing! ;)

  • @skadelbai1
    @skadelbai1 6 лет назад +1

    How long before it gets down to 38°?

  • @josuealvrado6348
    @josuealvrado6348 3 года назад

    I have a reach in Refrigiration. It’s not cooling, the compressor and the condenser fan turn on even the evaporator fan turns on but it’s not getting cold. Any suggestions?? Anyone ?

  • @ThisyoungTony
    @ThisyoungTony 3 года назад

    id put my money on someone buying one of the auto part store 16oz 134 cans and thinking they are gonna fix it.

  • @robertgaitskell7212
    @robertgaitskell7212 5 лет назад

    Sorry weigh

  • @robertarnold6672
    @robertarnold6672 6 лет назад

    Question: Was this a cap tube system?

  • @zack9912000
    @zack9912000 6 лет назад

    Problem is it is a true cooler. Garbage