  • @nocompeterefrigerationserv7501
    @nocompeterefrigerationserv7501 7 лет назад +2

    Nor-Cal Refrigeration- True and Structural Concept always stands behind their products hence helping customers & service providers. Thanks for the great video!

  • @hvacrnortheastern2110
    @hvacrnortheastern2110 7 лет назад +2

    Nice job it nice see the manufacture stand behind their product helping the customer and the service they provide of giving out the whole condenser it is probably cheaper for them in the long. It make your job easy of installing the whole unit.In these days everything is throwaway.

  • @articairrefrigeration9142
    @articairrefrigeration9142 7 лет назад +1

    Dave thanks for your quick response

  • @hvactechpr7872
    @hvactechpr7872 7 лет назад +1

    awesome!! nice change and the replacement unit look better built!!

  • @sherwinalvarez7365
    @sherwinalvarez7365 4 года назад

    You are so right about True. I harvest the start components blade and motor because you never know.

  • @saltrue1555
    @saltrue1555 5 лет назад

    Thank you very much really nice video,instructive

  • @harrydickson4575
    @harrydickson4575 7 лет назад

    Another great job Dave

  • @jonhvac
    @jonhvac 7 лет назад +2

    $425 boo yeah! Looked like Jon HVAC put in that compressor ;) The Mr. 45fiveee. True is the most bestest.
    Enjoyed Mr. Dave.

  • @darkmagicriff
    @darkmagicriff 7 лет назад +1

    Nice work again and again and again,,,,,etc,,,,,,

  • @scottk0623
    @scottk0623 4 года назад

    Dave where did you get those hoses for that Testo 550? Nice job. Great score on that van

  • @UlisesPalacios
    @UlisesPalacios 7 лет назад

    Damn that's a great deal on that van. Those testos look new. I just cleaned mine today and put fresh gaskets in my hoses.

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      Ulises Palacios the bag keeps the testos clean ya the van was a deal.

  • @charleyh8340
    @charleyh8340 7 лет назад +1

    Nice hoses man where did you get them

  • @fredk7813
    @fredk7813 7 лет назад +1

    Iam the same way.....OCD you just have a certain way that you have adapted to over the years......

  • @sincityhvacr
    @sincityhvacr 7 лет назад

    hi sir what size filter drier do u have on ur recovery machine thank you

  • @JStorysuoertech
    @JStorysuoertech 3 года назад

    True has an amazing tech support also.

  • @aircooledtx
    @aircooledtx 7 лет назад

    Nice quick change-out. True does have few good points, hate their leaker/coils.

  • @heavydiesel
    @heavydiesel 7 лет назад +5

    Great tip on the tags!
    Just spent $35k on a new van, old one had 140k mile on it and was getting expensive to keep on the road.
    Do you have to send the old compressor back for warranty?
    Great work as usual!

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад +2

      heavydiesel no just a picture of the lable.

    • @mjojo1000
      @mjojo1000 7 лет назад

      Nor-Cal Refrigeration & H.V.A.C do you have any old refrigerator condensing units i could have for a project

  • @marlontravis6526
    @marlontravis6526 7 лет назад +1

    I often have suction pressure below 10# myself after charging to factory specs even after changing cap tubes to exact OEM. I sometimes 2nd guess myself and want to add a few more ounces; and I often have in the past only to see the head pressure rise too fast. Thanks for reassuring me to stick to the factory specs.

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад +1

      marlon travis good to hear. I need to call true and get the design evap temp

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      marlon travis I just talked to tech support they told me a 12 degree evap which is 14psig and 105 degree condensing which is 135 Psig is normal for that keg cooler. R134A

    • @marlontravis6526
      @marlontravis6526 7 лет назад +2

      Thanks for the feedback. I've watched every video in your subscription. I'm a huge fan of your work, awesome soundtracks, and above all The Vangina:-) Keep up the good work. There're a few good HVACR channels out there, but I personally think you're the best in my humble opinion. Thanks for sharing.

    • @billcv80
      @billcv80 7 лет назад +1

      I get impatient charging them to...gotta let the condenser heat up!

    • @vladopajank2444
      @vladopajank2444 7 лет назад

      i will second that.

  • @ulyssestrejo
    @ulyssestrejo 7 лет назад

    Ride it till the wheels fall off lol!! Awesome videos bro! quick question what would be better, an exhaust fan or air intake for two condensers that cook in the summer? units are on top of walk in boxes.

  • @calvinthompson5398
    @calvinthompson5398 4 года назад

    Nice!

  • @kevincabrera7747
    @kevincabrera7747 7 лет назад

    have you done one with r290 yet

  • @kinggenius6660
    @kinggenius6660 7 лет назад +1

    first comment? good job as you always do!

  • @kingofthecrease30
    @kingofthecrease30 7 лет назад +3

    it seems like the low side pressure is low even though you weighed it in because of the high side gauge being on the system...a 5 or 6 ft hose will hold 2 oz of gas plus your low side hose holds another 2 oz...i notice the low side pressure goes up when you purge out the high side gauge and get the full charge in. Yellow Jacket sent me a chart with how much refrigerant a 5 ft and 6 ft hose holds...it varies depending on which refrigerant and ambient temp.

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      kingofthecrease30 it did go up to 12 after purging the hoses. And it's cooling like a champ. Call today to check on it.

  • @justin0957
    @justin0957 7 лет назад +3

    It's True, I crave you. Na na na na na na

  • @expeditoquirino2790
    @expeditoquirino2790 7 лет назад

    Boa noite seus videos são muito bom muito obrigado sou do Brasil

  • @RobHVAC
    @RobHVAC 7 лет назад +1

    Nice of True to do that.

  • @kinggenius6660
    @kinggenius6660 7 лет назад +1

    curious about how much do you think the MFG adds in the price of the equipment to cover any warranties?? 40% would be my guess

  • @jonnymac31
    @jonnymac31 7 лет назад +3

    Badass

  • @articairrefrigeration9142
    @articairrefrigeration9142 7 лет назад +2

    I have over charged a couple of these beer coolers by a few ounces and they seem to work fine what's your take on that

  • @Sixta16
    @Sixta16 7 лет назад +3

    WAGO connectors are pretty much standard everywhere in the EU for the last decade. Nice to see the US has discovered them. :D Europeans hate wirenuts :)

    • @Sixta16
      @Sixta16 7 лет назад +1

      Good to see True have sent the whole new condenser. Wow.

  • @notanewbie1718
    @notanewbie1718 7 лет назад

    How many repairs have you had to do on the van? I have stuff failing a lot on my newer chevy box truck.

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      Nilo Hissom I replaced the intake gaskets and rear piñon Bering and radiator. That's it.

  • @AfroThriller
    @AfroThriller 7 лет назад +1

    That's not OCD that's just efficient! I do it all the time

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      Spencer Applewhite I like that a lot. Thank you.

    • @OcRefrig
      @OcRefrig 7 лет назад +1

      Me too. Efficiency is Key. Repeatability is key in our trade. same way gets same results. it's when u change u have problems.

  • @AVR-hf1rl
    @AVR-hf1rl 7 лет назад +1

    don't mean to sound stupid but where did you get your charging hoses and do you have a part number
    Thanks

  • @randomrazr
    @randomrazr 2 года назад

    do you know if TRUE still honors warranty if u take over a cooler from the original owner

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 года назад

      Good question. I think so. The compressor they run cabinet serial number and if in 5 years ship out replacement.

  • @bradmironik6137
    @bradmironik6137 6 лет назад +1

    The van was a good investment.

  • @TheJakenesbit
    @TheJakenesbit 6 лет назад

    hey dave im a commercial refrigeration apprentice. Im looking to go digital ( probes, guages) what brand would you reccomend for me ? I know you have tried a number of them. cheers

    • @NorCal-refrigeration
      @NorCal-refrigeration  6 лет назад

      Jacob Nesbit that’s a good question because now there are so many choices. I honestly don’t know on the gauges. I have the sman and the Testo 550, the 550 are great for the price. I have not tried the new yellow jacket digital yet. The probes if you can afford them the iconnect is the best. The Fieldpiece probes now can be used with measureQuick looks good.

  • @articairrefrigeration9142
    @articairrefrigeration9142 7 лет назад

    how many Oz. do you think is in the the charging lines

  • @rosskious7084
    @rosskious7084 3 года назад

    You like the Testo 550?

  • @philltafolla
    @philltafolla 7 лет назад

    Yo Dave I'll give you $450 for the vangina and lll throw in a chorizo con huevos , deal? jk.. bud great repair how long did you have to wait for the unit to come down to temp ?I remember I had an issue with a Coldtech 2 door freezer , I charged it by scale my suction pressure was low , I added some more and booom... head pressure started rising, so I remove the charge, charged it by scale again, and I had about 20psig suction, and 245psig discharge 😁 bad ass!

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      Felipe Tafolla no long at all. You can see the clock on the iPad. At 65 degrees then at 37 degrees.

    • @philltafolla
      @philltafolla 7 лет назад +1

      Nor-Cal Refrigeration & H.V.A.C cool thanks Dave

  • @TheGhettoLobster
    @TheGhettoLobster 7 лет назад

    Windows on the truck? Break in waiting to happen. Hope the best for you. Our trucks get broken in all the time and they have puck locks on them with no windows.

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад +2

      TheGhettoLobster the world is full of tweekers now. Is everywhere. We can't even shoot em here even in the house.

  • @1984juant
    @1984juant 7 лет назад

    so no vehicle debt? sweet

  • @rubin2200
    @rubin2200 6 лет назад

    #VANGINA

  • @kylebickford9476
    @kylebickford9476 3 года назад

    ill give you 500 for the van bro

  • @MrDjonks86
    @MrDjonks86 4 года назад

    Get this backpack from yellow jacket 10146 way better

  • @royalbrianwalker6637
    @royalbrianwalker6637 7 лет назад +1

    TRUE ROCKSTHE OTHER STUFF NOT

  • @dennisnoone7427
    @dennisnoone7427 7 лет назад

    you stole the vangina!
    another year or two, thats how i thought about my 95 e150 endup keeping it for seven more years. Keep the vangina till she dies!

  • @zekemontgomery6678
    @zekemontgomery6678 6 лет назад

    True is junk. The end

  • @OcRefrig
    @OcRefrig 7 лет назад +4

    Something i do to Avoid the liquid in the hose scenario. i only Guage up on Hot Gas Side of the units. i install my access valves on the hot gas side never liquid side. same pressure just a gaseous state rather than the Liquid state which is Huge. because the units we work on have such small charges it makes a HUGE difference. NO Liquid in my hose ever only hot gas which's affect is miniscule. once u Weigh in the charge it turns to gas. weigh in the Liquid charge in on the hot gas line where it enters the condenser. i just weld in an access tee there. when guaging up much less affect on small systems.

  • @OcRefrig
    @OcRefrig 7 лет назад

    Yea, True is Awesome about thier warrantys. thats a good point u Bring up about the Cheapo Korean or chinese units out there. i have not had any warranty dealing with them yet. i think it's only a one year warranty if that. Have u had any dealing with the cheapo units under warranty and whats the Scoop ?

    • @NorCal-refrigeration
      @NorCal-refrigeration  7 лет назад

      OcRefrigeration,Hvac & Electrical. No I'm not doing warranty on those.