My Luck Is Never This Good - A Day In The Life Of A Gas Engineer 121

Поделиться
HTML-код
  • Опубликовано: 19 фев 2024
  • My luck is never this good! Canoe filter actually came out in one piece! Dealing with blocked plates, hot water issues and many more.
    Don't forget to like and subscribe if you haven't already!
    #plumbing #heating #boiler
    Related video
    Easy way to change a Worcester plate
    • Worcester Bosch plate ...
    unilite.co.uk/?ref=uncle
    Use code UNCLE for 25% off
    Powered Now - Job Management Software
    www.powerednow.com/cputility-2
    towel radiator
    vaillant
    ufh
    underfloor heating
    blockage
    magnetite
    scale
    lockshield
    radiator valves
    electric
    boiler
    electrical
    wiring

Комментарии • 59

  • @cputilitysolutions
    @cputilitysolutions  4 месяца назад +1

    Thank you for watching and please don't forget to LIKE & SUBSCRIBE 🙏🏾

  • @macpatel7810
    @macpatel7810 4 месяца назад +2

    Dennis the menace 🤣. Great job Dennis.. he's a natural in front of the camera.

  • @tonymurff5234
    @tonymurff5234 4 месяца назад +2

    Peer Pressure on the young lad 😂😂,
    Brilliant video as always mate 👍
    👍👍🤜🤠

  • @mrt864
    @mrt864 4 месяца назад +1

    Another great video, thank you. I love the diagnostics

  • @philipbrown2628
    @philipbrown2628 4 месяца назад +2

    Oooo ripples on the heat engine !!!!!

  • @Heatking
    @Heatking 4 месяца назад +1

    Great video mate, I can’t believe the canoe filter was pretty much clean but the flow pipe was choked up! 🤷🏽‍♂️😂 well done Dennis 🎉

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +2

      Yeah man I was expecting to have to break the old one out!

  • @ryandow3954
    @ryandow3954 4 месяца назад +1

    Nice one Dennis, well done mate! 👍

  • @ohforfxcksake
    @ohforfxcksake 4 месяца назад +1

    Well done Dennis, nothing worse than having an audience 👌

  • @andrewoleary9704
    @andrewoleary9704 4 месяца назад +1

    Good job Dennis

  • @robharrison6918
    @robharrison6918 4 месяца назад +1

    Oh no, that could have been you first plate clean in situ. You had the vent pipe open and could have drawn some cleaner in.
    Maybe next time you’ll give it a go. 10 minutes max 👍

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +1

      Yes mate this job was done before your previous suggestion, got a backlog of videos to upload! But yes I'm looking forward to trying that method out 👍🏾

  • @k20aa
    @k20aa 4 месяца назад +1

    Good job dennis 👍👍👍

  • @chriswhite3090
    @chriswhite3090 4 месяца назад +1

    Sometimes it's best to disconnect the pipe from the main hex first then out at the bottom on the vaillants as it can crack the main hex where the pipe pushes in

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +1

      Sound advice mate, I've seen that happen before thankfully not to me!

  • @johnmurray2470
    @johnmurray2470 4 месяца назад +6

    She's still watching

  • @Bobbymac2000
    @Bobbymac2000 4 месяца назад +1

    S.53 on the Vaillant’s is a good indicator that there’s a restriction on the DHW side.

  • @user-te1le7ck6b
    @user-te1le7ck6b 4 месяца назад +2

    Vaillant going down veissman route with pipe blockages

  • @douglaughton7626
    @douglaughton7626 4 месяца назад +1

    After cleaning out the flow pipe and replacing the canoe, did you replace all the o rings? If not, that’s really lucky 😂

  • @ashleymapes3926
    @ashleymapes3926 4 месяца назад +2

    Gotta love a watcher 😂

  • @sudhiradhikari19
    @sudhiradhikari19 4 месяца назад +1

    Nice one, just want to know what paste you were using while doing radiator valve.

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +1

      Rapid blue for the tails and jet blue for the compression

  • @heatpump8566
    @heatpump8566 4 месяца назад +1

    Hope I’m wrong but I think the wb will come back in. Great vid bud

  • @unayssheikh1070
    @unayssheikh1070 4 месяца назад +1

    Fault finding is really interesting to me. Takes experience knowing what the problem could be just based on customers description or noise coming from the boiler.
    Are there any good resources which can help an apprentice out in fault finding?

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +1

      There's plenty of resources out there but the best way to learn is to get stuck in and learn on the job. Majority of my experience came from working in social housing. I did courses, etc but it didn't fully make sense until I was working in it myself

  • @joncoke8208
    @joncoke8208 4 месяца назад

    You never tried that flushing method ?

  • @hali5341
    @hali5341 4 месяца назад +1

    How did you take out that canoe filter in one piece, every time i try i end up cracking it, what techniques or tool did you use to take the canoe filter out, did you check the red seals on the Worcester green star they comon on those there a safety bulitin every time you remove the case you need to check if it not leaking

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +1

      It just came out easily which was shocking! Yeah I always check the red seals thanks 👍🏾

  • @MrGoonerguy
    @MrGoonerguy 4 месяца назад +1

    That Worcester main HX had more ripples than the North Sea 😂 bet the HX seal/electrodes were toast

    • @cputilitysolutions
      @cputilitysolutions  4 месяца назад +1

      I thought the same but sweep test was fine, must have been changed previously

  • @normanboyes4983
    @normanboyes4983 4 месяца назад +1

    Why do you replace the PHE rather than clean it out?

  • @joncoke8208
    @joncoke8208 4 месяца назад

    Whos the apprentice in the back ground?

  • @gregbenham5586
    @gregbenham5586 4 месяца назад +2

    I bet she was easy to find when playing hid n seek

  • @davebayliss3142
    @davebayliss3142 4 месяца назад +1

    Worcester Horrible horrible boilers