Another Worcester With Problems, Surprised?! - A Day In The Life Of A Gas Engineer 155
HTML-код
- Опубликовано: 27 сен 2024
- Another Worcester Bosch with problems, surprised?! Then an Ideal Logic with the usual issues that need sorting, just a day of sorting out minor issues.
Hope you enjoy the video!
As always, thank you all for supporting the channel, I appreciate it!
#plumbing #heating #boiler
velocityprogea...
unilite.co.uk/...
Unilite IL-925R
unilite.co.uk/...
Use code UNCLE for 25% off
Powered Now - Job Management Software
www.powerednow...
towel radiator
vaillant
ufh
underfloor heating
blockage
magnetite
scale
lockshield
radiator valves
electric
boiler
electrical
wiring
Great vid Chirag❤. Sound advice as usual..
Thank you 👍🏾
Great information as always mate
Thank you 🙏🏾
When the crap man doesn't want to collect these boilers you know somethings up Broski
💯
hahaha you knew that case was going to fall over
I never learn 😂😂
Your P.A. is doing a great job there lol
😂
😂 foreal, good P.A
On the ideal logics... How can you tell which part is gone when it vibrates? For e.g. if I put boiler in low mode and it vibrates/ does this mean gas valve? And in high/does this mean burner? The way to differentiate between the two has always confused me! Have you come across this? 👍
(Vibrate and rumble through ignition and for a few minutes at random intervals)
I've had it before to be either one! Usually though the low rumbling tends to be the burner and if it whistles then it's more likely the gas valve
that ideal, was that left screw on condensate door over tightened by someone previously? or did the plastic just go. be nice to know. stick a screw in there and see if it moves. good luck on that sump change they are a pita. you can gain a few mill by losening the heat exchanger from the boiler casing but you probably know.
i always change the bearing plate on bosch too on a full stripdown with service kit.
great videos as usual.
Thanks mate, yeah Ideal went out under warranty and replaced a few parts 👍🏾
Hey mate thought I recognised that house I went there for ideal 😂 in Brentwood wasnt it? I replaced burner had reverb on low rate partially blocked if I remember rightly
Yes mate that's the one! They said they've not had anymore issues since so the new burner must have sorted it. Thanks! 👊🏾
What’s reverb on low rate? What was partially blocked? Thanks
@@gasnewbie1941 reverb is when you get a vibrating sound whirring hard to describe. youll know it when you hear it.. burner is blocked or what i was told and you can test it theres a plate you can see from where the fan conects with circular holes in it, its spot welded and you can see where on the top of the burner. one of the spot welds back left as the burner sits in the boiler as i recall fails sometimes. stick your finger in there and see if it moves. cant remember if it was reverb on high or low rate. maybe the ideal guy can confirm. i scrached my head on that one for sure. ideal support were brilliant as usual.
When I last spoke to ideal they said providing burner seal is intact and no damage. Can be re-used . I always carry one just incase. Also told not to do sweep inside 'ONLY FI' 🤷🏻♂️👊🏻
Yup they advise not to do a sweep test because the burner gasket is porous and they allow up to 50ppm (I think) around it. Madness that a boiler manufacturer allows that, but then again they also let their boilers overheat and catch fire so doesn't speak much for their quality assurance standards 😂
I know it's absolute madness..... keep it up 👊🏻
@@cputilitysolutions thats a bit unfair i think. ideal have been pro active on getting that sorted didnt push blame onto service guys or installers and took it on the chin, more than i can say vaillant and glowworm did back in the day. blaming everyone exept themselves. do you remember when they came from the factory with rubber heat exchanger door seals seals before they changed it to graphite with lock nuts (your probably too young), prior to that do you remember them putting rubber pipes with jubilee clips on flow and return from the heat exchanger as a quick fix for noise problems.
Idea say you don’t have to change the burner gasket on removal?
Ok 👍🏾
Ideal really are the worst boilers out there by a mile. Sump’s leak, they set alight! No better than the Isra’s and icos. I genuinely don’t know why anyone would fit one
💯
A lovely little breakdown changing a sump though ?
Worcester are the worst boiler out there
💯
Hate em 😂
Ey? I LOVE worcesters...they give me SO much work!! 🤣🤟😁
You're back at that logic ya fit a clock on! ✌️ Had a L2 yesterday, wasn't rectifying - cleaned venturi, electrode, injector & gas valve & syphon checked - working fine! ✌️
Yup the same one 😅
Great video mate, let us know what the outcome is with ideal 👍🏼
So the Ideal engineer who attended actually commented on this video earlier on! He changed the burner and it's not happened again since so 👌🏾
Happy father's day mate. Ideals have a lot of faults but I love talkng them apart. A doddle if youve done a few same as greesnstars to be fair.
Thank you mate 🙏🏾
How much do you charge for service and strip down service?
Within my local area £80+vat for a standard service and £160+vat for full strip down. Parts, service kits, etc are additional if required
I'm undercharging!! I only quoted 100 for a full strip down . It was a logic though which are easy to get apart plus I'm not running a business I'm doing it as a spiv
What is the white crust?
Dried POCs
Mate il be honest, you get a serious amount of callbacks lol. I think ive had 1 in my time😂😂
You clearly don’t do much work out in the field then. Every break down engineer will get recalls from time to time. It’s just part and parcel of the job
@@drewburrows475 when your as good as me and know how to fix boilers, its a gift. Some people are better than others fixing boilers, i regard myself as up there. When it comes to installs, im by no way the quickest man alive at it lol
Well done to you then 👍🏾
@@drewburrows475 i do about 5 breakdowns a day, got a fantastic van stock and get the job done. Breakdowns are super easy if you know what your doing. Ive been to thousands of L2s and not had one callback from one. Any boiler, be it oil or gas, il fix it first time. Installs im slow, so everyone has strengths and weaknesses
Looks like that Worcester you went to was a very bad installation crusty flue think it was fitted with 13amp plug gas valve to boiler in 15mm just didn’t look a good install really but hey what can you say it’s a Worcester boiler lol….good video m8t you look a decent lad with nice family respect..🙏
Thanks man 👍🏾