How A Diverter Valve Works In A Combi Boiler - Gas Training for new Plumbers

Поделиться
HTML-код
  • Опубликовано: 3 апр 2021
  • Looking at how a Brass Diverter Valve works in a gas combi boiler.
    Roy From Viva Training Academy shows us how the diverter valve and hydroblock works in a gas boiler. Understanding how to repair a gas boiler.
  • ХоббиХобби

Комментарии • 45

  • @AllenHart999
    @AllenHart999  3 года назад +7

    Bobbin Type Flow switch: 10l/min 7211823
    12l/min 7211822
    40kW 16l/min 7211824
    Turbine Type Flow switch 10l/min 7663535
    12l/min 7663533
    15l/min 7715773
    New Brass Diverter Cartridge 7656807
    Black & White Diverter motor 7216534

  • @marksenior1179
    @marksenior1179 3 года назад +3

    Thanks again Roy and Allen, for making it as simple as black and white.

  • @user-nb5ki9wo7r
    @user-nb5ki9wo7r 4 месяца назад

    This video helped me to understand why my 10year old Potterton Gold HE was banging sometimes. It was when radiator valves closed at certain temperatures. Ordered the motor head using the correct part number but the non- spring loaded type was supplied-This was the source of the problem. Sorted now, thanks for the free advice.

  • @mcginn002
    @mcginn002 3 года назад +3

    Roy you are a legend , a fountain of knowledge 👍

  • @rayc1503
    @rayc1503 3 года назад +1

    Fantastic Al & Roy, & thanks to viva for making this possible. You're both extremely knowledgable engineers 👍.

  • @bahiaharjinder
    @bahiaharjinder 3 года назад +2

    Hi allen thanks for another super sunday video, hydro block on a baxi combi instant would be awesome
    Thankyou roy + viva

  • @iheggis86
    @iheggis86 3 года назад +2

    Another great video thanks Roy & Allen

  • @emzdarlington9661
    @emzdarlington9661 9 месяцев назад +1

    Seriously very helpful video guys, can thank u guys enough for the high effort goes in these videos

    • @AllenHart999
      @AllenHart999  9 месяцев назад

      Thank you very much for watching

  • @zeeshannajib1787
    @zeeshannajib1787 3 года назад +1

    Very well explained, you made it simple and easy to understand

  • @moulesanctuary
    @moulesanctuary 2 года назад

    Brilliant classroom stuff .. Ive learned alot .. I am on my way to change a divertor and the motor this morning

  • @brendanconnolly8341
    @brendanconnolly8341 2 года назад

    Excellent as always

  • @paulnixon4489
    @paulnixon4489 3 года назад +2

    The worlds our Royster. 👍

  • @tonywardell3411
    @tonywardell3411 2 года назад

    Brilliant video thanks lads

  • @abualam4418
    @abualam4418 2 года назад

    🙏 thank you.
    Appreciate your work

  • @mikecave4154
    @mikecave4154 3 года назад +2

    Top video lads 👍

  • @arronblythe8086
    @arronblythe8086 3 года назад

    Cracking little Video 👌

  • @sheriefgerges7789
    @sheriefgerges7789 3 года назад +1

    Great Video, what is the part no of spigot for the pump and brass washer for thermistor
    Thanks alot

  • @veronicahart450
    @veronicahart450 3 года назад

    Good video

  • @kalsingh3660
    @kalsingh3660 4 месяца назад

    Hi Allen, thank you for this detailed video. Really helped me out! Many of these motors look fairly universal, not sure if you know but would this motor fit a Ariston HE series boiler? They all look extremely similar.

  • @oscaribarramartinez1033
    @oscaribarramartinez1033 11 месяцев назад +1

    Fantastic

  • @suheilhanna873
    @suheilhanna873 3 года назад

    Great one, would you please zoom in, to see the part clearly, appreciate your hard work. 🙏

  • @rayc1503
    @rayc1503 3 года назад

    Roy/Allen could I just ask the effects on water flow rates. Lets say if I were to put a larger or smaller plate to plate on a boiler. How would the boiler behave? I've never tried it myself, I'm just curious that's all, thanks 😉.

  • @daviddavues1677
    @daviddavues1677 3 года назад +2

    Legends

  • @sheriefgerges7789
    @sheriefgerges7789 3 года назад

    Hi Allen when I write the part no to find flow switch turbine type can't find all bobbing type can you please put link for turbine type to buy one
    Thank you

  • @baffoxxx2117
    @baffoxxx2117 2 года назад

    Hello, my question is the following:
    When the boiler is off, where is the three-way valve positioned towards the heating systems or the sanitary water?
    Thanks

  • @neil5628
    @neil5628 2 года назад

    Does the light flash red on the right side diverter valve when its not giving hot water??

  • @BELHORIZON31
    @BELHORIZON31 2 года назад

    Hi, i got an issue with no hot water, can i just remove the cartridge from the diverter clean it and the. Cross the finger?

  • @Hannah-yz6in
    @Hannah-yz6in 2 года назад +1

    Can’t believe this video is only 11 months old- thought it must have been from years back with the way you’re describing people as blokes who can’t read instructions etc. I love your content and find it so helpful but the world is changing and it’d be good to see you be more mindful of all the women who work in this industry. And not all the men who do this job are just ‘blokes who don’t read instructions’! Come on Allen and Roy- you’re better than that!!

  • @terryquinlan5901
    @terryquinlan5901 Год назад

    My boiler is pressurising itselve,I have changed the pressure or expansion vessel and the divert or valve cartridge also cleaned and flushed out the plate exchanger ,the pressure vessel is pumped up to 1 bar with air but the pressure still rises to 3bar and continually releases to via the external pipe. I have also removed the filling loop on the boiler and capped off pleased help before I go mad what do you thing is causing my problem Terry

  • @davidb2464
    @davidb2464 3 года назад

    Again, great video Roy. I may have missed it, but let's say that the hall-effect sensor is faulty/blocked, what might the symptoms be? Would you suggest giving things like these a quick rinse on a service every couple of years?

    • @royfugler9971
      @royfugler9971 3 года назад +2

      Hi David, Thanks for the feedback.
      If the hall effects sensor is blocked, the red led wouldn't light up.
      Hopefully soon we will do a video on a live boiler and I'll demonstrate what would happen and how to test it.

    • @davidb2464
      @davidb2464 3 года назад

      @@royfugler9971 Hi Roy, thanks for a great answer, looking forward to the video of this. Keep up the good work.

  • @richardnixon8410
    @richardnixon8410 3 года назад

    Roy, my 105 instant diverter valve is letting by in CH and pre heat mode, I overhauled the valve with a kit , but still lets by, any ideas pls, I descaled the Plate h/e and top up expansion vessel.

    • @royfugler9971
      @royfugler9971 3 года назад

      Hi Richard.
      Check the by-pass valve in the rear of the right hand hydroblock, it could have dirt on the seat.

  • @chriswhitehead6095
    @chriswhitehead6095 3 года назад +1

    Halstead Eden CBX hydroblock

  • @huunghiem
    @huunghiem 3 года назад

    Hi Allen I got Baxi 28E it that mean if my boiler are on then I turn my hot tap on the diverter stop run hot to my radiator? I just noticed the light on the boiler turn over to the hot tap if I run the hot tap.or you should see both light on(hot tap and the radiator light on)?
    Thank

    • @royfugler9971
      @royfugler9971 3 года назад +1

      Hi Yo,
      Yes when you turn a tap on the diverter moves to hot water and shuts off the central heating, once you turn the tap off if there is still a demand for central heating the diverter valve will move back over. With a combi you can only have hot water or heating on at one time not both together, that is why the radiator light goes off when you run the tap.

    • @royfugler9971
      @royfugler9971 3 года назад +1

      Sorry Ho, I spelt you name wrong

  • @user-pl7oo6dc3j
    @user-pl7oo6dc3j Год назад

    Hi, after gas safety engineer left the water wasn’t heating he came back and fiddled with some pipes under the boiler and then we had hot water. This happened twice! This year the radiators don’t heat up! They were ok until April and the safety engineer came in August… now it turns in for around 10-15 seconds and the boiler flame light turns off! I wonder if this time he has stopped s valve or something connected to the radiators? I’m a little suspicious that he charges the landlord every time he visits our flat. Please help!

  • @strider0106
    @strider0106 3 года назад +1

    you forgot to give us the part numbers

  • @derekclark7545
    @derekclark7545 3 года назад

    Can you do a Vaillant hydro block, well you did say anything. hahaha.

  • @TheMrC99
    @TheMrC99 2 года назад

    Hart. Allen Hart. Licence to unchill.