Start-to-Finish Radiant Floor System (by DIYers) 🔥

Поделиться
HTML-код
  • Опубликовано: 20 мар 2023
  • A start to finish recap of how we installed our radiant floor heating system in our 36x40 slab. This will work in parallel with our ductless mini split system to keep our garage space comfortable year-round. Check out our Radiant Floor Heating playlist for all the details leading up to this! Comment if you have any questions and stay tuned for system start up!
    * LINK TO ENTIRE HOUSE BUILD PLAYLIST: • Self-Building Our Home...
    💰 See the exact cost details for our radiant heat floor system ⬇️
    www.masondixonacres.com/produ...
    --------------------------------------------------------
    🔨 Alex's Tools: urlgeni.us/amazon/AlexsTopTools
    🧰 Alex's Toolbelt (Stile): toolbelts.com/?rfsn=7781903.8...
    (get 10% off with code MasonDixon10)
    👕 Alex's Workwear:
    Shorts: truewerk.pxf.io/CloudShort
    Pants: truewerk.pxf.io/T3pant
    Jacket: truewerk.pxf.io/WoobieHoodie
    Long Sleeve: truewerk.pxf.io/B1LongSleeve
    Short Sleeve: truewerk.pxf.io/B1ShortSleeve
    👚 Elaina's Workwear:
    Canvas Utility Pants: collabs.shop/u4lk2e
    Relaxed, High-waisted pants: collabs.shop/jihpyg
    🌱 Elaina's Garden Gear: urlgeni.us/amazon/ElainasGard...
    🌻 Favorite Seed Starting Trays: collabs.shop/pla2vz
    🐥 Organic, Non-GMO Chicken Feed: bit.ly/layermash
    (get 15% off with code masondixon15)
    Our Camera Gear ⬇️
    -Main Camera 1: amzn.to/4aKsars
    -Main Camera 2: amzn.to/3Hbf4pB
    -Drone: amzn.to/3TKkMGu
    -Wireless Mic: amzn.to/3wDwYvL
    -Voiceover Mic: amzn.to/3kVu0A4
    -Main gimbal: amzn.to/3HhH8Hj
    -iPhone gimbal: amzn.to/3HfX1ya
    -Camera backpack: amzn.to/3wB6DOS
    --------------------------------------------------------
    Follow us on IG & Facebook for real-time progress!
    Instagram: / masondixonacres
    Facebook: / masondixonacres
    DISCLAIMER: Links included in this description may be affiliate links. If you purchase a product with these links, we may receive a small commission at no additional cost to you! Thank you for supporting our channel ☺️
    #construction #building #plumbing

Комментарии • 133

  • @MasonDixonAcres
    @MasonDixonAcres  7 месяцев назад +2

    Interested in seeing the exact cost details and where we bought everything for our radiant heat floor system? We have the spreadsheet available on our website: www.masondixonacres.com/products/radiant-flooring-cost-spreadsheet

  • @tonycortez8556
    @tonycortez8556 3 дня назад

    Electrician here with an electrical contractor license, what you guys accomplished is amazing

  • @solarking4448
    @solarking4448 Год назад +12

    As a master electrician I think you did nice work. Better than most DIY

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Much appreciated! I hope that carries through to electrical rough in 😄

  • @johnathandoe3558
    @johnathandoe3558 2 дня назад

    You guys did an awesome job.

  • @tonycortez8556
    @tonycortez8556 3 дня назад

    Coal brewed coffee would be the perfect name

  • @haripriya2485
    @haripriya2485 10 месяцев назад

    Thanks for making it so fun to watch.

  • @billybike57
    @billybike57 Год назад

    Awesome craftsmanship!

  • @backwardsrun
    @backwardsrun Год назад

    I just starting to build a house and quickly finding out I doing it ll my self but yall have been such a welcomed encouragement so a thousand times thank you both.😊

  • @markr2297
    @markr2297 Год назад +1

    I like the attention to detail and making everything look neat and orderly. All the grunts paid off.
    PS: Camp fire coffee and cooking was good practice for our future visits. Glad you’re working the process for future events.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Thanks Mark!! Eventually we'll have a nice landscaped fire circle set up 😁

  • @bendugas8632
    @bendugas8632 6 месяцев назад

    Oh , sorry, it is very interesting and informative. Thank you

  • @frankieboy2417
    @frankieboy2417 Год назад +9

    I am a retired Ironworker and had done the rebar structure for these floors since they first came onto the construction sites. My ankles are still sore from working around these floors. You guys never seem to be surprised by your determination of doing things yourself, like me I always hated paying someone to do what I can regardless if I did it before.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Rebar is tough work! We definitely like to do things ourselves when possible 💪

  • @Thefunny25_
    @Thefunny25_ Год назад

    Just found your channel from a short! Having just finished a smaller scale house reno, I've found a new love for doing things myself instead of paying someone else to do it. I'll be watching more!

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +2

      Awesome, we have the same thought. While it is slower, we learn so much and the satisfaction is fantastic.

    • @jeffjodyauman7774
      @jeffjodyauman7774 7 месяцев назад

      great work, and yes, very professional looking! Just be careful if you plan on running the outdoor outlet on the same circuit as your critical circuits for your heating system. That way, you don't have something outside like a storm or hosing down your siding, the whole cirucuit doesn't trip due to water intrusion.

  • @averageliving4Life
    @averageliving4Life Год назад

    40min video!? Well worth the time. I probably won't incorporate my radiant floors until after we get in the house. But this will definitely be a reference! Good job.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Thanks! Yeah this one was quite a marathon.. many months of footage combined 😅

  • @flimmaytinstone8980
    @flimmaytinstone8980 5 месяцев назад

    I knew you were gonna say ow! With that little piece of wood. Great job btw

  • @bojangles_bonjangles8000
    @bojangles_bonjangles8000 Год назад +3

    Plumbing work looks good. Don't worry about the Sharkbite coupling, they are code and will be fine for what you are using it for. Nice work!

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      I appreciate it!!

    • @Chris_dahlen
      @Chris_dahlen 3 месяца назад

      After saying you watched y.t. videos on soldering, you forgot to say, you also stayed at Holiday Express.

  • @user-zy3hj7wm4m
    @user-zy3hj7wm4m 7 месяцев назад

    Nice work i did notice one loop too close to the toilet make sure you use a rubber gasket on the toilet opposed to wax.

  • @johnnythorn4847
    @johnnythorn4847 10 месяцев назад

    Thanks!

  • @rogerwhiting9310
    @rogerwhiting9310 7 месяцев назад

    That manifold looks exactly like my new Uponor.

  • @karl22GR
    @karl22GR Год назад +1

    I designed and built my house with radiant floors and have been through all of this! Good work! In my setup, the floor sensor doesn't really help. What I did was bore out a hole in a bottom plate of a wall, stick the sensor in there and jam it full of silicone. Even after installing this sensor at both of my thermostats I don't need to use it. The timer function on the thermostat is all you need. Your setup may be different becase of the depth of slab, amount of insulation, etc.. You will develop an understanding of your system only after living with it!!

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +1

      Yeah I'm already seeing the floor temperature doesn't mean a whole lot, the thermostat default is to keep the air temp at a set point, and only pays attention to floor temp to keep it between min and max limits (45 and 80 I believe). So far so good!

    • @karl22GR
      @karl22GR Год назад

      @@MasonDixonAcres My slab might be thicker than most, so the time delay between when the system turns on and when any heat is felt in the room is over three hours. I can't let the system run until the thermostat kicks off because the slab would be overloaded with heat. So its a bit of a guessing game. I usually watch the weather and adjust the water temperature and/or the lenth of time that my system runs in the morning, but only really need to change that a few times over the winter.

  • @JR-ci2pk
    @JR-ci2pk Год назад

    Thanks for the videos, helps answer some questions I have. I’m designing a garage apartment, I was wondering about the exhaust that close to a operating window. Keep it up

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +1

      There’s a full table of clearances in the manual of whatever tankless you buy, and I think those are derived from National fuel gas code. I checked our manual again and it’s 1ft in the US and 3ft in Canada for a direct vent next to an operable a window

  • @johnbanks8065
    @johnbanks8065 7 месяцев назад

    This is the first of your videos I've watched, but I've really enjoyed it so I'll go back and start watching the rest. One thing that instantly struck me though, and I'm surprised no-one else has commented on it, is that I don't think it's ideal to have your electrical outlet directly underneath the boiler; any leaks would potentially be straight into that outlet.

    • @MasonDixonAcres
      @MasonDixonAcres  7 месяцев назад

      Thanks! I think someone else did comment on that a while back, I agree that was definitely not best practice in hindsight 😂 however with it being GFI and the low liklihood of a tankless springing a leak with yearly maintenance, it should be okay

  • @lovethosebudgies
    @lovethosebudgies 5 месяцев назад

    After all your work, without question you've earned those grunts lol.

  • @aliveandwell2078
    @aliveandwell2078 Месяц назад

    Armored cable would have been nice for all the exposed wiring. Nice work!

  • @richardscarlett7942
    @richardscarlett7942 3 месяца назад

    you need to relocate tall outleta, switch boxes and junction boxes out from under and away from any water connections that could leak and out from under all water and sewer drains pipes

  • @MattSapp
    @MattSapp Год назад

    Hey Alex. I'm also not a tradesman, but I do have one suggestion for you - on your electrical box you put in, it looks like you wound the ground wire around the ground screw counter-clockwise. I've always seen it suggested, and it makes sense to me, to run that wire around the screw clockwise so there is less chance of the loop trying to unwind as you tighten down the screw. I wouldn't bother going back and changing this one as it appeared secure, but as you wire in receptacles and future boxes, something to look out for. Gotta be exciting to make this progress!

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Oh that's interesting! I just took a needle nose pliers and formed a tiny circle that held the screw captive and then tightened it in the box. Never thought about which way the circle was wound. Funny enough I do actually need to go change that screw out, because they are supposed to be green by code but I only found a silver one laying around. Or just go in there with a green sharpie 😁 Most of our boxes will be nonmetallic, actually about to go pickup all the electrical rough in supplies tomorrow. It's definitely nice to be getting to mechanicals, lots of fun ahead

    • @MattSapp
      @MattSapp Год назад

      @@MasonDixonAcres Did you get cited by an inspector on the green screw? I've seen people that believe it has to be green in these boxes, and also plenty that say it does not. I have not been able to find a code reference that requires a green screw outside of the panel bonding jumper in a panel (250.28c), just that it must be threaded, not a self-tapper (250.8), and that it can't be used for anything else (250.148)

  • @Mightyeldo
    @Mightyeldo 6 месяцев назад

    Do you have a video that shows how water flows and each component of the system works? Thanks

  • @kevinhornbuckle
    @kevinhornbuckle Год назад +1

    Nice work. When you use metal clamps to secure plastic pipe, cut a strip of rubber from an old bicycle inner tube or roofing membrane. Put it under the clamp so that the plastic is isolated from the metal.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +1

      Good tip! I wrapped the ones securing our gas manifold in electrical tape but didn’t bother for the rest. You’re thinking just as a chafe guard?

    • @kevinhornbuckle
      @kevinhornbuckle Год назад

      @@MasonDixonAcres I believe that is the rationale behind the code. Your condensate pipe is not under water pressure. So it will never chafe. So maybe the inspector won't care.

  • @Overpar73
    @Overpar73 Год назад

    Very nice job, I'm really not looking forward to building my in floor system, I will have 13 runs and a combi boiler!

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      It's actually pretty fun once you get into the swing of it! I would definitely do it again for a future shop.

  • @tylerlanders4315
    @tylerlanders4315 Год назад +1

    Great work! It's always a fun time learning new skills. I've seen some people that use closed loop glycol vs open loop water. What were the deciding factors for y'all choosing open over closed?

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Thank you, agreed! Biggest one was being able to use the same heating appliance for both floor and domestic water. Also the open system makes sure the water never gets stagnant in the floor during summer. It's a very simple system and I like that there isn't even a control needed for the boiler.

    • @tylerlanders4315
      @tylerlanders4315 Год назад

      @@MasonDixonAcres That makes sense! I didn't realize you were using the same heating appliance for both. Looked great!

  • @karlthorson971
    @karlthorson971 5 месяцев назад

    Just wondering how hard your water is and if the scale inhibitor is doing its job? also are you on a well?

  • @bigrick1772
    @bigrick1772 3 месяца назад

    Do you have a monthly cost for the in floor radiant/temp setting?? I am also on propane and will be building a 40x60 ft pole barn w/ in floor radiant. I am in NY and experience 10-45 degrees in the winter from November- April.

  • @wd269
    @wd269 3 месяца назад

    @Mason Dixon Acres - Would you mind sharing the size of the sweep 90s that were used to turn the pex vertical? I watched a number of your radiant floor videos. Very helpful - thanks!

  • @petersl2449
    @petersl2449 9 месяцев назад +1

    Question, for the electrical... conduit is not required? I thought romex had to be either behind sheet rock (fire barrier) or in a PVC conduit or EMT metal conduit. Or is this a barn non living area?

    • @MasonDixonAcres
      @MasonDixonAcres  9 месяцев назад

      The NEC is vague on this so it’s left to the local AHJ and ours was fine with it. The NEC states something like no surface mounted nm-b where exposed to hazard. Conduit and thhn or MC cable would also work. This is in a utility room attached to the garage and separated from the living space in the same manner as the garage.

  • @ericdolan2130
    @ericdolan2130 6 месяцев назад

    Quick FYI, the adhesive on duct tape can damage / weaken the pex tubing. Make sure you do that on the stuff that is excess.

    • @MasonDixonAcres
      @MasonDixonAcres  5 месяцев назад

      oh never heard of that! Can you explain why?

  • @dspears666
    @dspears666 Год назад

    Great video. But shouldn’t your vent pipe slope toward the outside so any condensation will run out and not into the heater?

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +2

      Nope, otherwise it will drip icicles in the winter. When it goes back into the heater, it ends up in the condensate drain where it belongs

  • @grante1461
    @grante1461 Год назад +1

    I worked at the new rockwool plant in WV until recently! There's a decent chance my crew made that insulation for you lol

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +2

      Awesome!! You may have had a hand in our house 😉

    • @grante1461
      @grante1461 Год назад

      Consider me honored!

  • @johnf8877
    @johnf8877 Год назад +1

    In my area, they would require that the electrical be run in conduit if exposed to the room.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      I'll learn for sure when the inspector comes for plumbing (impossible to get ahold of him otherwise), worst case I'll swap it for MC cable. He's pretty flexible though so I'd be surprised if that's the case

  • @ericfraser7543
    @ericfraser7543 Год назад +1

    13:04 I was going to say they sell a fireproof fabric for this purpose, but I am guessing beyond this piping you are not using too much copper in your home, though I might be using pex rather than that CPVC supply pipe, seen some horror stories with that pipe. I think that manifold was a good investment and price too prob $500 in fittings and pipe alone.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +1

      Yeah i was too cheap to buy the little fireproof blanket 😂 for this little bit of pipe leading to the manifold i was trying to avoid the flow restriction from traditional PEX-b fittings and I didn’t really want to hassle with expansion PEX since i don’t have the tool and fittings are a pain to find. If the cpvc ever gives me a problem I’ll just replace with copper since it’s less than 10’ total. I’ve only ever seen problems with cpvc when it freezes, so fingers crossed that never happens 🤞🏼

  • @AF-O6
    @AF-O6 7 месяцев назад

    You must surely research all night and work all day. I bet you’re looking forward to sleep!
    I was a GC for many years, and your work is better crafted than 99% of the jobs I’ve seen. My only point would be that not all municipalities will let you surface mount nmc cable. I’d recommend a raceway or pre-wire before you installed your plywood. …but you’re doing a super job!

    • @MasonDixonAcres
      @MasonDixonAcres  7 месяцев назад +1

      Thanks so much! I cleared the surface mounted nm-b with our inspector ahead of time, NEC allows it but is vague

  • @vandalorian8777
    @vandalorian8777 7 месяцев назад +1

    Great Job! The only thing I would have changed is the cpvc. It’s a shame to see all of that pretty copper attached to white plastic

    • @MasonDixonAcres
      @MasonDixonAcres  7 месяцев назад +1

      Thought about it but it had to transition at some point due to the cpvc ball valve coming off the well tank valve. I also didn't see much extra value in copper for the amount of extra labor and material cost

    • @vandalorian8777
      @vandalorian8777 7 месяцев назад

      @@MasonDixonAcres I would have done the same but it still would have hurt me every time I looked at it. 😀

  • @markjanes2392
    @markjanes2392 9 месяцев назад

    Not sure if anyone pointed this out yet but, it needs to be in conduit using thhn wire not romex. Romex can be exposed but it has to be 6’6” off the ground. I own an electrical company, over all it looks great.

    • @MasonDixonAcres
      @MasonDixonAcres  9 месяцев назад +1

      Thank you! The NEC is vague on this so it’s left to the local AHJ and ours was fine with it. The NEC states something like no surface mounted nm-b where exposed to hazard. Conduit and thhn or MC cable would also work

  • @MrInkotime
    @MrInkotime 3 месяца назад

    So how do you control each room in the house? Where are the thermostats for those or is it one temp throughout?

    • @MasonDixonAcres
      @MasonDixonAcres  3 месяца назад

      This is only for the slab, there is just the one air/floor thermostat shown

  • @TrevPagesPlace
    @TrevPagesPlace Год назад

    Curious, I noticed the lack of an expansion tank. Do you not require one where you live? We're building a home with a heated slab as well

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад +1

      With an open system you don’t need one - the well pressure tank serves as the expansion tank

  • @laminatedhalo
    @laminatedhalo 2 месяца назад

    Hey, so is your radiant system circulating potable water? I couldn’t see for sure, but looked like it. It looks like maybe the Takagi boilers are designed for potable water? If not, it will rust out from dissolved oxygen in the water. If you have a standard cast iron pump, that will also rust.
    All the other systems I’ve seen (and my system) are closed loop once filled, so the oxygen comes out of solution once it heats and that inhibits corrosion in all the ferric parts.

    • @MasonDixonAcres
      @MasonDixonAcres  2 месяца назад

      Yes, this is an open system. More info on Radiant Floor Company's site

  • @VacMaster2020
    @VacMaster2020 9 месяцев назад

    So is the radiant heating hooked up to the boiler directly, and not like an indirect or a separate set of connections on the tankless unit? Is it the same connection for the boiler and the hot water because if it’s set up that way, that’s not right

    • @MasonDixonAcres
      @MasonDixonAcres  9 месяцев назад +1

      You can see all the details here: www.radiantcompany.com/system/opensystem/

  • @Tenebrius1963
    @Tenebrius1963 11 месяцев назад

    Did you put a vapor barrier on top of your insulation before putting the final plywood?

    • @MasonDixonAcres
      @MasonDixonAcres  11 месяцев назад

      Nope. Not a good idea for our climate.

  • @johnf8877
    @johnf8877 Год назад

    Dutch oven; usually 2:1 coals top vs bottom. Get welding gloves. Those cotton gloves are a hazard near flame.

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      Good tip, I'll put those on the list for the next Harbor Freight trip 😁

  • @bob3md2
    @bob3md2 9 месяцев назад

    Can you reference the instagram that shows how to make the unistrut pipe clamp holder?

    • @MasonDixonAcres
      @MasonDixonAcres  9 месяцев назад

      it was a static post on @mechanicalhub quite a while back. Not a how-to, just an photo that I copied the technique

  • @maciejkowalczyk1426
    @maciejkowalczyk1426 5 месяцев назад

    Could the power outlet under the water heater cause a problem if there is a leak?

    • @MasonDixonAcres
      @MasonDixonAcres  5 месяцев назад

      Location could have definitely been better on that, but it is a GFCI recep at the least. May relocate in the future, however I would imagine these tankless boilers aren't prone to catastrophic leakage like normal tanked heaters

  • @rickallen8158
    @rickallen8158 5 месяцев назад

    Can you say specifically what insulation you used in the walls and where to buy it?

    • @MasonDixonAcres
      @MasonDixonAcres  5 месяцев назад

      ROCKWOOL ComfortBatt R23! Should be available at most HD/Lowes or any insulation supplier

  • @spinxt
    @spinxt 4 месяца назад

    Great video! I work in the plumbing/ HVAC supply industry and, like you, I love saving money by doing all of this kind of stuff DYI. Are you guys in PA? (I noticed the PSU mitt your wife had on).

    • @MasonDixonAcres
      @MasonDixonAcres  4 месяца назад +1

      Right on! Yep we both went to PSU!

    • @spinxt
      @spinxt 4 месяца назад

      @@MasonDixonAcres me too! My wife and I just brought a piece of lakefront property on Smith Mountain Lake in Virginia. I plan on doing a lot of my own work when we build. What portions of your build did you outsource/ vs doing on your own?

    • @MasonDixonAcres
      @MasonDixonAcres  4 месяца назад

      We will probably do a whole blog post & video on this question eventually, but basically outsourced the things which were highly impractical if not impossible to do ourselves - laying block, slab pour, roof framing, metal roof install, dropping the well pump, drywall, seamless gutters. Two items (excavation, soffit/fascia) we could have done, but had friends or bartered for others to do it instead. Everything else we are doing ourselves.

  • @geniferteal4178
    @geniferteal4178 7 месяцев назад

    Did they let you install the exhaust beneath the window like that?
    Watch out for carbon monoxide coming in the window.

    • @MasonDixonAcres
      @MasonDixonAcres  7 месяцев назад

      3ft is all that's required to a window opening per the heater install instructions

    • @geniferteal4178
      @geniferteal4178 7 месяцев назад

      @@MasonDixonAcres ok. Didn't realize it was just a height thing

  • @allthingsgrowing
    @allthingsgrowing 4 месяца назад

    next time, get yourself a heat gun, warm those joints up and the pex pipe usually slides right off the fittings with a small tug.

    • @MasonDixonAcres
      @MasonDixonAcres  4 месяца назад

      Good tip thank you!!

    • @allthingsgrowing
      @allthingsgrowing 4 месяца назад

      @@MasonDixonAcres anytime. I wish I had people helping me when I needed it. All the best in your new lives. Congratulations on your build. Bangup job! Be proud!

  • @iainf6
    @iainf6 Год назад

    👍🤗

  • @euphgolf
    @euphgolf Год назад +2

    Not sure what electrical code year your area has adopted, but flush-mounted non-metallic cable is not allowed anywhere from floor height to 5' above floor height. Needs to be armored cable or individual wires running through EMT, or non-metallic cable is ok running through the studs like any other interior wall. Great work though. Your inspector may not be too picky. Given you were doing this back in January, you might already know this. Love the channel. This rule doesn't count for your ultra-low voltage cable (thermostat).

    • @MasonDixonAcres
      @MasonDixonAcres  Год назад

      I did look into code on this before and it seemed fairly open to interpretation by the AHJ, the verbiage was something like protected from physical damage “where necessary” but didn’t have any height requirements. I’ll talk to him about it when we do our rough plumbing inspection before I run anything else. Thanks for the input!!

    • @euphgolf
      @euphgolf Год назад +2

      @@MasonDixonAcres You are correct in that the code doesn't stipulate the height. If your code official approves any exposed NM cable below 5', immediately go out and buy a lottery ticket. You are having a lucky day :)

    • @petersl2449
      @petersl2449 9 месяцев назад +1

      I had the same question.... it's odd to see exposed romex that is not behind sheetrock or if exposed not in PVC and/or EMT conduit. Even in the attic, the inpsecter wanted the romex either covered or in conduit ~7ft around the hatch. And the attic was simply a service area for the furnace.. was not a living space. That maybe extreme but in a common areas I would expect wires to have some covering (drywall or conduit or plywood). Drywall is a fire barrier too.

  • @shamoy1000
    @shamoy1000 5 месяцев назад

    I've never seen a tradesman do as neet clean looking installed as you did. Unless they were working on their own house. 😅

  • @MuddyCreekPines
    @MuddyCreekPines Год назад

    I was your 100th thumbs up woohoo!!

  • @EnergySeeker
    @EnergySeeker 5 месяцев назад

    water ?? not glycol ?

  • @markradtke5398
    @markradtke5398 5 месяцев назад

    Am I the only one who thinks "the ham" was a turkey? :)

  • @qwkcivic95
    @qwkcivic95 9 месяцев назад

    How many square foot is your building?

  • @billb3268
    @billb3268 3 месяца назад

    Hope your putting up vapor barrier behind all your plywood. Well actually everywhere

  • @dolmarf411
    @dolmarf411 5 месяцев назад

    OMG , no plastic behind the wood bords??? moister WILL go behind it.

  • @cheeseymccheese7249
    @cheeseymccheese7249 6 месяцев назад

    Wish i could find a cute wife like yours that wants to homestead haha.

  • @Craig-qx7uy
    @Craig-qx7uy 25 дней назад

    He called it unistrut. Somebody cooked here…

  • @bendugas8632
    @bendugas8632 6 месяцев назад

    I know you are saving a lot of money by installing it yourself. What about warranty and building codes for the insurance? How do you get away from this?

  • @shermansas
    @shermansas Месяц назад

    You shouldn't mix the domestic with hydronic water. A lot of jurisdictions restrict this because it will be a health hazard. If you wanted to use the boiler to heat domestic you should use an indirect tank. "After longer periods of inactivity, such as after the summer, the heating water has been stagnant for weeks or months, allowing more time for legionella to multiply." When you turn the heat on in the fall your water will taste like crap.

    • @MasonDixonAcres
      @MasonDixonAcres  Месяц назад

      In an open system, the water in the floor flows any time a hot water fixture is opened. It doesn't sit - the tankless draws cold water from the floor, which is replaced by cold water from the well. More info on the Radiant Floor Company's site

    • @shermansas
      @shermansas Месяц назад

      It will always choose the path of least resistance, it will not go through all of the floor loops and because there is mixing valves it will most likely only go straight to the boiler. This is why many places require a backflow prevention device between the hydronic and domestic water. Any place governed by codes will not allow this setup. The ucc states "M2101.3 Protection of Potable Water The potable water system shall be protected from backflow in accordance with the provisions listed in Section P2902.mrpexsystems.com/wp-content/uploads/2021/12/Radiant-Combination-System-Recommendations.pdf @@MasonDixonAcres

    • @MasonDixonAcres
      @MasonDixonAcres  Месяц назад

      The code reference seems to assume a closed system, the term backflow in its traditional sense doesn't really apply to an open system. There's flow into the system, circulation, and flow out of the system when domestic hot water is used. Our inspector had no problem with this setup. The recommendation you linked is certainly good info, and it's true that the tankless isn't drawing 100% from the loops due to the mixing valve but it's not 0% either. We will test our water annually and if something changes it would be easy enough to convert to a closed loop, but as far as I can tell at this point, an open system is no more risky for bacterial growth than a guest shower that gets used twice a year.

  • @user-gu4mw2py5c
    @user-gu4mw2py5c 3 месяца назад

    Check state code... Usually water heaters have to be on their own circuits... But this is 10 months ago... so meh!

    • @MasonDixonAcres
      @MasonDixonAcres  3 месяца назад

      If it were electric, yes. Gas tankless uses very little current

    • @user-gu4mw2py5c
      @user-gu4mw2py5c 3 месяца назад

      @@MasonDixonAcresi had a 20amp circuit in the garage. I went from a pilot light 50 gallon tank to a Bosch tankless. When I sold the house the inspector made a big deal about me sharing the power from the rest of the garage and they made me put in a dedicated circuit. It was natural gas driven. But they still wanted to see a dedicated circuit. 🤷🏼‍♂️

  • @mindfullygreen2870
    @mindfullygreen2870 3 месяца назад

    Damn. Looks too hard