Code 11,12,13 live troubleshooting with an Agent

Поделиться
HTML-код
  • Опубликовано: 2 янв 2023
  • An interaction between a Tech and a Rheem agent, what you may expect to have a tech do to verify heater operations on hard to locate problems. At the end of the day an Agent can rule out a water heater malfunction and be confident on recommending the installation and environmental factors be scrutinized.

Комментарии • 72

  • @PatrickJeon-os5vg
    @PatrickJeon-os5vg 8 месяцев назад +11

    This was an exact replacement for the old one that lasted about 10 years. ruclips.net/user/postUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).

  • @mikeb4808
    @mikeb4808 Год назад +4

    Great video sir. I have intermittent code 11. My heater is much smaller than one you show. I will have to remove some aluminum covers to get to flame rods. Gonna try cleaning those first

  • @Mail4eb
    @Mail4eb 17 дней назад

    awesome video very helpful
    When probing small connections use a small paper clip to get into back of connector then touch meter probes to paper clips

  • @macnyac5105
    @macnyac5105 Год назад +9

    Hello,
    Thanks for making the video. It will be great if each error code solution was time tagged to chapters i.e error code 11, 0.5minute-15minutes, that way you can choose the error code you’re having with ease and not confuse the solutions.

    • @rickpowell1402
      @rickpowell1402  Год назад +2

      I agree. Not quite that good at editing yet. But will get there.

  • @vnesmuonnam
    @vnesmuonnam 9 месяцев назад

    Thank you for taking time to make video. Learnt a lot from it

  • @zumadale
    @zumadale Год назад +1

    Super video! This is great! Thanks!

  • @zumadale
    @zumadale Год назад +2

    Was wondering what that baggie of gaskets was for! Thanks!

  • @allisontrousdale5768
    @allisontrousdale5768 5 месяцев назад +1

    One of the gaskets completely crumbled and so OHL was damaged. What would cause it to crumble? We're being told nothing can be done, but the gasket should not have crumbled! We've only had this unit for 2 years!!

  • @VladRonin
    @VladRonin 15 дней назад

    How about E 3 code ? I had this code for 5 years old Eccotemp. Hot water was always 120 F. Vent is clean, water pressure, gas pressure - Ok. I did Flushed water heater by cleaning vinegar. Still code E 3 On. Contacted costumer support - no help...

  • @zumadale
    @zumadale Год назад +1

    Randomly tripping code 12...once a month maybe. I'm at altitude...6500 feet. I have the altitude dip switch set right. My venting is 10 feet with one wide sweep 90 degree. As a experiment...I set dip 2 switch 2 on...supposed to be for extra long venting...which I shouldn't need. I want to see what happens.

  • @davidlambert8772
    @davidlambert8772 Год назад

    Excellent video

  • @surefire07
    @surefire07 Год назад +3

    I see the complexity in the compact high efficiency hot water heating system. Being an electrical engineer, I would say it is not too difficult to design a diagnostic system which points to a one or two defective component to fix the problem. In short these designers have long way to go to design their own control systems in place of subcontracted out to the China mass product design team.

    • @gregbergman8601
      @gregbergman8601 10 месяцев назад

      I'm an electrical Engineer as well and I completely agree with you. I've been tempted to do exactly that. I've owned tankless water heaters for 15+ years and I have found the diagnostics to be quite aggravating.

  • @Mammothbaron
    @Mammothbaron Год назад +3

    This was very helpful. I unfortunately have once again been getting a code 12 once a day for the last 3 days. Water Heater was installed in in august last year. I spent 3 days on the phone with Rheem support trying to stop code 12. We determined everything was ok installation wise. The manifold set point chart on the heater was not on the unit. In aug, I basically increased the manifold set points until the code 12 stopped triggering every time the unit fired. At what point should I use the unit warranty now that this is starting to occur? I am going to check dynamic and static gas pressures today with my manometer again. It was fine in august.

    • @F-TV-ri4nm
      @F-TV-ri4nm Месяц назад

      Did you check small filter cap every time before?

  • @indymark4064
    @indymark4064 4 месяца назад

    I have bought 3 Rheem tankless heaters so far. First was for my house when we had propane. 2nd was to replace the LP when we drilled a NG gas well. The third was in anticipation of building a house for my daughter. An LP unit. Installation went without any problems, and according to directions and code. (I thought) A couple days ago my daughter called and had no hot water. It would come on, briefly and shut off. On as, light on remote comes on humms a bit and shuts off. Inside 01 flashing. I had her turn on hot water, and heard only a humm, no start. I suspected the fan motor as it's the first to come on. I called the 800 # in the manual and reached a service agent lady who took all our info. She asked where the unit was installed, -in a basement, under a factory built, modular home. Not mobile, modular. She told me they would not cover it under warranty. Ok. How about tell me whats wrong. NOPE. She said it was not designed for mobile home applications. Its in a conventionally built basement under a normally looking home. NOT mobile. It was like talking to a rubber wall. Anything I said she came back with the same answer. I told her Rheem just lost a future customer.
    I don't give a sh.. where it's installed, she could at least help with troubleshooting. I looked up the HUD document code she quoted, and I could not fine anything that related to a different requirement for mobile home or conventional home installations. Or how they should be built. We tried about 6 different plumbers, 3 didn't work on them 2 don't like to, "there too hard", and 1 said it would be about a week. $275 just to come out. +++ So I'm on ytube checking all different things it might be. Next searching for parts suppliers. FU.. Rheem.

    • @rickpowell1402
      @rickpowell1402  4 месяца назад

      There is definitely a difference between a modular home and a mobile home. Who was it you spoke with? Name? What is the serial number to your unit ?

  • @Truthfulfisherman
    @Truthfulfisherman Год назад

    When I did the blue cable ( flame rod 2) only I got a 4. What did it mean?

  • @anthonyhitchings1051
    @anthonyhitchings1051 Месяц назад

    Got a code 11 on my brand new Rheem tankless gas WH - I had forgotten to turn the gas valve on!

  • @nadreggid
    @nadreggid 3 месяца назад

    This vid is awsome. Now I need to know what tool is used to test the input gas pressure. Thank you!!!

  • @bkoz319
    @bkoz319 Год назад +3

    Do you know what causes the cover of the unit to deflect (making a popping sound) when the unit is first turned on? I have asked rheem tech support and no one has a clear answer....any ideas? thanks

    • @JosePerez-ih9ko
      @JosePerez-ih9ko Год назад +1

      mine does the same for the last 5 yrs.

    • @rickpowell1402
      @rickpowell1402  Год назад

      Check all screws. Make sure it’s all tight. When blower kicks on there is a change in the air pressure and the front panel can make that noise.

  • @firstreachdevelopment3305
    @firstreachdevelopment3305 Год назад

    Awesome!!!!!

  • @DeejayNightro
    @DeejayNightro 4 месяца назад +1

    @10:15 is Code 12

  • @qjack5883
    @qjack5883 7 месяцев назад

    Would descaling help with error code 13?

    • @rickpowell1402
      @rickpowell1402  7 месяцев назад

      No, code 13 would need to be investigated. Venting must be checked. Check venting dip switches, lengths and elevation settings. Gas pressures both static and dynamic checked and also checked when other gas appliances are firing. The burner may also need to be checked and cleaned. However if the burner is very dirty this is a symptom of a problem. Which means it will dirty up again if you cannot determine what’s causing it.

  • @chrisnelson3470
    @chrisnelson3470 Год назад +2

    Thanks for the great video. I’m getting a error 12 but it is intermittent maybe once a month but when it does happen it seems to repeat for a day or so. Any idea what this could be?

    • @rickpowell1402
      @rickpowell1402  Год назад

      Venting or gas issues. Possible due to install error or environmental. Venting needs to be inspected, proper setting for vent and elevations checks. Gas pressure both static and dynamic. If you have other things on the gas system and the system isn’t sized properly you will have issues. Check burner clean as needed.

    • @chrisnelson3470
      @chrisnelson3470 Год назад

      @@rickpowell1402 Thanks for the reply. I did have it professionally installed. I double checked everything. Used 2” pipe but only 11 ft with 3 elbows so no need to change dip switches. Over sized main gas line 2”down to 3/4” at water heater. There is a 2’ flex gas pipe but looks like that meets requirements. What pressure should I be looking for on the gas line? It’s just 2 years old.

    • @rickpowell1402
      @rickpowell1402  Год назад +1

      @@chrisnelson3470 Look on your rating plate by model and serial number, the gas specs will be there. you'll need to insure the pressures do not drop to low when other appliances are using gas along with the heater.

    • @zumadale
      @zumadale Год назад

      I am having same issue once a month code 12...I adjusted Dip 2 switch number 2 to on...going to see if it fixes it....I'm at altitude..6500 feet...I have the dip switch set for this altitude

  • @unicornhollowhomestead
    @unicornhollowhomestead 3 месяца назад

    Where are y’all getting codes?

  • @chadlyles5444
    @chadlyles5444 3 месяца назад

    I have no power to the heart control where you see the temperature an codes

  • @hilltopchiro
    @hilltopchiro 4 месяца назад

    First off all, thank you Rick and thank you Rheem for making this video. I realize you didn’t have to do this, but wow I learned a lot.
    Second, I have a RTGH-95DVLN, serial RHUNM131307877 tankless. I have error 13, but also failing the flame rod tests (around min 16). My 2 flame rods look very different from each other and have different connectors, but I can only find 1 part on Rheem’s part site. Can I essentially use 2 flame rod 1s (white) instead of a white & blue?
    Thank you!

    • @rickpowell1402
      @rickpowell1402  4 месяца назад

      Do you have the interior water heater or is yours on the exterior with the side outlet vent?

    • @hilltopchiro
      @hilltopchiro 4 месяца назад

      Interior with top vents.

    • @rickpowell1402
      @rickpowell1402  4 месяца назад

      then you should have FL1 and FL2. on the right will be the igniter. yes the blue and white plugs are the same. And the flame rods should also be identical.

    • @hilltopchiro
      @hilltopchiro 4 месяца назад

      It won’t let me post a picture, but my flame rods are skewed to the left a little more than in your example unit. My flame rod 1 (white connector) looks just like yours, but the far left flame rod (blue connector) has a slightly larger pin connector and the flame rod itself is shorter for some reason.

    • @rickpowell1402
      @rickpowell1402  4 месяца назад +1

      Ah you have the fist generation. Yes they will be different.
      Get the correct replacement. Look online as other places carry parts also.

  • @mexicolindo5290
    @mexicolindo5290 3 месяца назад

    No have power in the termostato, help me

  • @timsevilla3168
    @timsevilla3168 Год назад +2

    When is code 13 addressed in the video?

    • @rickpowell1402
      @rickpowell1402  Год назад +2

      Testing the gas valve. Code 13 you want to check gas and venting and be sure to check it 100%. In the video the testing of the gas valve and solenoids will be a code 13 check. Cleaning flame rods and cleaning burner assembly may also be a step you’ll need to take.

  • @yoliet6859
    @yoliet6859 21 день назад

    Control panel turned off and can’t turn it on, why?

  • @ht894600
    @ht894600 Год назад

    What do you do if the plastic wrap is torn?

  • @elkhunter307
    @elkhunter307 Год назад +9

    That freaking beeping is the bane of my existence. I will never buy a green again. Nothing but issues and no answers from tech support. Not even a year old I have had flame rods go bad, thermistors go bad, ignition coil. Just a nightmare of a unit.

    • @rickpowell1402
      @rickpowell1402  Год назад +1

      Take it back and exchange it, also have someone familiar with reading the use and care manual check the install, a lot of issues are installation related

    • @elkhunter307
      @elkhunter307 Год назад

      I might have it. The 5/8 gas line doesn’t support enough btu . Got a 1” od that has up to 290kbtu let’s hope this fixes it.

    • @rickpowell1402
      @rickpowell1402  Год назад +1

      What is your serial number ?

    • @rickpowell1402
      @rickpowell1402  Год назад

      @@SunriseLAW I would recommend you have a different installer look at your system, the venting and intake are not correct, the correct configuration is outlined in the use and care manual. If you want to return the unit that is not anything Rheem will prevent you from doing, tell your point of purchase you have a defect and want it swapped out. They do not need to call Rheem to do an exchange anymore than walmart would need to call Apple to swap out some airpods. However I do believe the issues are caused in some part by the incorrect install, If I were you I would have a serious conversation with your installer, and then get a different one.

    • @rickpowell1402
      @rickpowell1402  Год назад

      @@SunriseLAW I'm Just here trying to help fix water heaters, If you want me to try and help you further I'm happy to do so.

  • @nadreggid
    @nadreggid 3 месяца назад

    Great Instructional Video! Why is the thermal safety plastic non-replacable? The rest of the unit is fine. I hate to throw away $1400.00.

    • @rickpowell1402
      @rickpowell1402  3 месяца назад

      It was a decision that was made way up the food chain. I don’t have info but it may either have to do with them not wanting the heat exchanger removed in the field or they wanted it to be harder to bypass. It’s a shame because they’re are people that can do this, truly mechanical engineering type people, but there are more of the other type that install outdoor water heaters indoors, breathe in exhaust, and then have to go to the Dr for headaches. Can’t count the number of times I’ve seen that.

  • @DR-um2bv
    @DR-um2bv 9 месяцев назад

    O NO
    not obd2 codes. These things gonna be worst than cars.
    Check engine lights
    I thought I wanted 1 of these. Now I may just stick with the old proven and reliable tank.
    That thing looks like space ship behind the panel.

    • @rickpowell1402
      @rickpowell1402  9 месяцев назад +2

      If we can educate the majority of plumbers diagnosis and repairs will be quicker and easier, these heaters are also still very serviceable by homeowners. It looks intimidating but it’s not.

    • @chrisnow1105
      @chrisnow1105 3 месяца назад

      It's irreplaceable if you need constant hot water flow like for my big hot top. With 40 gallons tank I had less than half of needed water. I installed tankless myself and for 8 years was perfect. Now I have to figure out error 13

  • @api9714
    @api9714 Год назад +2

    I'll stick with my conv water heater thank you.

  • @KimberlyMahoney-sl5wi
    @KimberlyMahoney-sl5wi 23 дня назад

    Code 29