Really Good. Have a Navien and it just went dark on me. No power to controller. Slight drip from actual Water heater outer casing!! Unplugged, going to open it and see what is leaking, possibly fried the unit?
I'd say water savers in your shower heads. Code 12 is a flame out. It was burning then it quit. P1 is low water pressure. So, something is restricting it. check the filter on the bottom of the heater too.
We have a Rinnai that from time to time stops working after a few minutes. We have no codes and it just reads the 120. It doesn’t happen all the time. We also just had it serviced and the tech said he couldn’t find anything wrong. Any suggestions what our problem is? Thanks
Thank You for video. I have Eccotemp 45 hi - natural gas water heater . Have code E 3. All is OK. Water pressure, gas, vent is clean .. HOW to reset that code.. I Turned OFF power for all day, dont helps. Thanks
It worked for three showers. The water starts hot for about five minutes then goes cold. Then the next day the shower stays hot?I think my tankless is bipolar?
Thank you! Great video and instructions 👌
Great Video. I now know what I need to do for the maintenance of my Rheem Tankless heater.
Glad it was helpful!
VERY INFORMATIVE... THANK YOU VERY MUCH!!!
This video has been a big help for me!
Thank you, so much!
Any suggestions on how to fix a fill error on a ruud combi boiler?
What about this water heater not turning on at all?
Sweet
Really Good. Have a Navien and it just went dark on me. No power to controller. Slight drip from actual Water heater outer casing!! Unplugged, going to open it and see what is leaking, possibly fried the unit?
Hello did you figure out what the issue was to the controller?
Mine - the pressure regulator for the natural gas was stuck. Just tapped the regulator with the handle of a screwdriver and the water heater fired up.
surprisingly that has fixed the problem for me so many times .
I get Code 12, P1, 12, then P1 again. Any idea what that could be?
I'd say water savers in your shower heads. Code 12 is a flame out. It was burning then it quit. P1 is low water pressure. So, something is restricting it. check the filter on the bottom of the heater too.
We have a Rinnai that from time to time stops working after a few minutes. We have no codes and it just reads the 120. It doesn’t happen all the time. We also just had it serviced and the tech said he couldn’t find anything wrong. Any suggestions what our problem is? Thanks
Water savers in shower heads, something is slowing the flow,
What about 29? Can I fix it?
That a condensate code. check the condensate drain line.
What is code 1L
Thank You for video. I have Eccotemp 45 hi - natural gas water heater . Have code E 3. All is OK. Water pressure, gas, vent is clean .. HOW to reset that code.. I Turned OFF power for all day, dont helps. Thanks
Um, normally turning the power off for a few seconds does the trick. Eccotemp has a tech support number you can call, it's probably really simple.
@@PlumbingSolutionsLLC I DID BEFORE MANY TIMES. Heater was Off all nigh, but stil coming E 3 Code...
what is code 24?
that is a bad remote or remote wires
What does code 13 mean?
Indoor unit code normally means you got something in your venting. like bugs or some bird is trying to build a nest. check your vent .
How about error 14
We have removed the water savers in the shower heads
Did it fix the problem?
It worked for three showers. The water starts hot for about five minutes then goes cold. Then the next day the shower stays hot?I think my tankless is bipolar?
🚀🚀🚀🥬👐