Service call - All Frozen up iceomatic ice machine. ice0500HA2.

Поделиться
HTML-код
  • Опубликовано: 29 сен 2017
  • Service call - on a ice-o-matic ice machine. All Frozen up. ice0500HA2. 2004 Machine. Video shows How to Ohm out a Hot Gas Solenoid coil and what the Ohm Reading is on a Good 120 volt coil. Video also shows What a Worn out Harvest assist Probe Motor Looks like in a machine.
    Please Share My Video's on Facebook and any other Social media sites with Links to My Video's.
    Serving--- All of Orange County , California. Since 1981.
    Commercial Refrigeration, Commercial and Residential Air Conditioning Service.
    Please Share My Video's on Facebook and any other Social media sites with Links to My Video's.
    Stealing the Actual Video by Uploading or Downloading is Prohibited.
    Removing the Watermark or altering the Video in any way is Not Allowed and is a Violation of Law.
    All Video's On this YOUTube Page OcRefrigeration & H.V.A.C. are the Property Of OcRefrigeration.com. No Video's Can be Used Commercially without my Express Writen Permission or Without the Express Written Consent of OcRefrigeration.com . All Video's are Copyrighted.
  • ХоббиХобби

Комментарии • 95

  • @robertweeks1171
    @robertweeks1171 6 лет назад +2

    The good old harvest assist motor. Ice o matic has had a lot of issues with this. A bunch of revises and now a complete rewire of the harvest assist. Good catch. Any time I come to an Ice o matic frozen up, I look to see if the pin is still sticking through the ice plate.

    • @OcRefrig
      @OcRefrig  6 лет назад

      Yea, Definately the Weak Link in the ice o matic ice machine.

  • @tcphvacr9950
    @tcphvacr9950 6 лет назад +1

    Seems like a good call to replace, since it’s older and all the things that need replacing or will in the future.

    • @OcRefrig
      @OcRefrig  6 лет назад +2

      We shall see. I hate to see My Customers Throw Good Money Down a Rusty Drain. It Needs Harvest motor & Cond. Fan mtr , Minimum & Labor to do it all Right now. Machine rusting out , water valve leaking / seeping right now & needs replaced soon. 13 yr old machine. Smart Money says Put a New Hoshi in its Place.

  • @NorCal-refrigeration
    @NorCal-refrigeration 6 лет назад +3

    Multiple Offender deluxe right there.

  • @rahmanyalshugaa3556
    @rahmanyalshugaa3556 3 года назад +1

    Thank you for your video of ice o matic ice machine, I got the problem of iceo 400, and it doing just mode of difrost hot gas no power coming to the seloniod valve could be harvest motor or the switch or replace the whole assembly harvest motor and switch

    • @OcRefrig
      @OcRefrig  3 года назад

      Glad it helped. replace the whole thing as an assembly. they are not expensive. best move.

  • @craigewing1844
    @craigewing1844 6 лет назад +3

    Thanks for all the refrigeration videos! I recently started a job working on Ice Machines am kinda lost so every video helps. Can you try to make a video that better describes pressure readings and how to properly recover, vacuum, and charge low pressure systems for a rookie l like myself? Thanks!

    • @OcRefrig
      @OcRefrig  6 лет назад

      What did u do before ?

    • @craigewing1844
      @craigewing1844 6 лет назад

      OcRefrigeration,Hvac & Electrical. Residential install

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      Ouch , from Resi installer to ice machine tech. Boy, someone threw u in the deep end. So, only difference between a ice machine and a airconditioner is the technology. Make sure u sign up for ALL THE ice machine schools Right away. it's a Must !!! Hoshizaki school , ice o matic & manitowoc schools. Without it YOU WILL BE LOST !!!

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      --- Similarities ---
      Recovery = Same as A\c.
      Evacuation = Same. Under 500 microns a must.
      Welding = same
      Pressure testing for Leaks = Same.
      Finding Refrigerant Leaks = Same
      Adding refrigerant = same.
      Refrigeration theory = same. Know your Pt chart. Pressure vs temperature for different refrigerants.
      Condenser fan motors = same. Just smaller
      --- Differences ---
      Circuit boards, electronics, hot gas defrost , Curtain switches , micro processors , water pumps, Water distribution tubes plugging up with crap. Corrosion , water leaks , harvest assist motors on ice o matics, No Evaporator fan = a Water pump is Now Your evap fan creating load on Your Evaporator Plate. Water inlet Solenoids , Liquid line solenoids ,

    • @OcRefrig
      @OcRefrig  6 лет назад +3

      1) Allways make sure Condenser is Clean First !
      2) Biggest Problem -Plugged water filters. It needs water to function. Make sure it has a decent water supply entering.
      3) 2ndbiggest problem - Plugged water distribution tubes with junk , slime , bacteria.
      4) 3rd --- Water Pump Plugged up with slime. Poor water flow. Clean spray bars allways.
      5) 4 th biggest problem - Loss of Refrigerant. Not common. Don't alkways assume a Refrigeration. More often than not. Ice machines DO NOT LEAK REFRIGERANT. RARELY. 9 times out of ten its a Machine is Dirty issue. Condenser plugged with Lint & Slime inside Evaporator area / Poor water flow.

  • @hvacrjunky6119
    @hvacrjunky6119 6 лет назад +2

    I would rather be fishing 🎣
    😎👍

  • @usamaali5239
    @usamaali5239 4 года назад +1

    Hi ,I have an Ice o matic 1406fo2 (220v) it use to fill the bin in a few hours now on average it produces about 10 bags per day . I've noticed on the left side it takes a long time to release the ice and by that time it becomes deformed .... I'm in Trinidad, I've had technicians look at it , serviced it said it's working fine ,but it's not ,please help

  • @patstansberry8189
    @patstansberry8189 6 лет назад +2

    Some of icematice design I wander what are they thinking. Example on pressure switches why don't they use shader valves that way you wouldn't have to recover freon to replace them and why do they put dryers on bottom of unit .They sure didn't think of service tech on design of unit

  • @gedyx
    @gedyx 6 лет назад +1

    Are you sure that machine was going into harvest? It looks like the low pressure delay timer was out , or the evaporator was bad , I did not see hook your gauges up to see the pressure on your harvest cycle

    • @OcRefrig
      @OcRefrig  6 лет назад

      Harvest motor seized up. Se vid 5:00. Merry Christmas & Happy New Year !

  • @jeremyboltin344
    @jeremyboltin344 5 лет назад +1

    Hey Man Y’all have a lot of Ice O Matic ice machine down your way don’t you

    • @OcRefrig
      @OcRefrig  5 лет назад

      Yes. 1/2 of them out here i Sold to the customers. 🤣🤣🤣

  • @Miketec81
    @Miketec81 6 лет назад +1

    What tips do you have for a newbie in refrigeration?

    • @OcRefrig
      @OcRefrig  6 лет назад

      Tips Regarding What ?

    • @OcRefrig
      @OcRefrig  6 лет назад +2

      Buy a Ge-H10G Leak detector to find leaks accurately.
      Allways Clean Your Condenser First ! Can u see Through the Condenser with a Flashlight ?
      Make sure evaporator is Clean and free of all ice first.
      Make Sure All your Fan motors are Turning in the right direction , i find fan blades installed backwards ALL the time.

  • @heavydiesel
    @heavydiesel 6 лет назад +2

    Looks like its time for replacement, if they had maintained it better then it would have been worth fixing. BER it, beyond economic repair!

  • @RaulFlores-zy5lt
    @RaulFlores-zy5lt 4 года назад +1

    I have a ice0400ha4 my question is does the harvest assist motor should it move while in freeze mode or should it stay still then move when in harvest?? Any help would be appreciated

    • @OcRefrig
      @OcRefrig  4 года назад +1

      in freeze - motor will spin to notch on brass wheel and stop. no more moving in freeze. in harvest - motor tries to move / slips on clutch till ice is pushed off then rotates to stop / notch position.

    • @RaulFlores-zy5lt
      @RaulFlores-zy5lt 4 года назад

      @@OcRefrig K cool thanks so much for the response yes I kinda thought that was the way it was but needed assurance thanks again

    • @OcRefrig
      @OcRefrig  4 года назад +1

      www.iceomatic.com/faq

  • @darinpugliese5103
    @darinpugliese5103 6 лет назад +1

    I have two 2013 iceomatic machines with small leaks around the compressor that I just can't see with bubbles yet

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      Buy yourself a Ge-H10 G Leak detector. It will make your life alot easier.

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      Turn ice maker off. Let system balance off for 30 minutes. No ice on the Plate. Go around with a leak detector. Check for cracked 90's from vibration. If u still can't find leak. Remove all rubber insulation from all piping and dry off tubing. Check for leaks. Check anything that contacts the floor of ice machine. Under drier ?

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      If u think leaks are somewhere sometimes they can be blowing from another direction. Leaks can be sneaky. Leaking Pressure switches ?

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      its probably leaking from the bottom of the filter drier and just blowing around the compressor. .

  • @centinelarefrigeracion8834
    @centinelarefrigeracion8834 5 лет назад +1

    Los temerarios background music.

  • @patstansberry8189
    @patstansberry8189 6 лет назад +1

    Iceomatic ice machines seem to have serious problems for 3-4 year old machines I have seen many leaks and evaporator failers working for C-store chain

    • @OcRefrig
      @OcRefrig  4 года назад

      Its Hit or Miss. I Have 3 Clients That i installed 3 New ice o matics in thier restaurants 10 Years Ago. All Good ! 1 Just starting to fail. compressor weak. 12 years old. still makes ice though. 1 Unit nickel playing coming off evap. 10 yrs old. 1 other iceomatic I did not install. ice 1406ha5 its a Lemon 🍋 Never ending problems. refrigerant leak / corroded out liquid drier at 4 years old. water pump failed at 6 years.

  • @MrLamixsoccer
    @MrLamixsoccer 4 года назад

    Hello my friend thank you for your video just so question what was the main problem because it was freezing up I have a service to finished and it is freezing up also what part did you replace you was the bin sensor can you reply my message please thank you very much

    • @OcRefrig
      @OcRefrig  4 года назад

      Harvest probe motor assembly Loose at back of evaporator area. Harvest assembly needs replaced.

    • @MrLamixsoccer
      @MrLamixsoccer 4 года назад

      @@OcRefrig thank you very much my friend I will do that because this ice o matic ice machine it makes ice but the next day woke up freezing up

    • @MrLamixsoccer
      @MrLamixsoccer 4 года назад

      @@OcRefrig thank you again my friend and also I wanted to mention that when I found the machine I found with that contactor burn out and obviously I replace it but it came out with this problem freezing up

    • @OcRefrig
      @OcRefrig  4 года назад

      it could also be the water pump stopping or getting a piece of scale sticking in the water pump impeller. clean machine real good before replacing probe motor. remove water pump and make sure its clean. no scale.

    • @OcRefrig
      @OcRefrig  4 года назад

      wash out water trough real good.
      remove water pump.
      check that water pump turns freely.

  • @kactusjoe
    @kactusjoe 6 лет назад +2

    That Machine Is Nasty ,Sell Them A New One ,Youll Be Doing Them A Favor

    • @OcRefrig
      @OcRefrig  6 лет назад

      Yep, thats what i told them. as i said in the video at 9:30 . thanks for watching.

  • @philltafolla
    @philltafolla 6 лет назад +3

    Just replace it with a Hoshizaki 😊

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      That would be nice , maybe. stay tuned for update.

    • @philltafolla
      @philltafolla 6 лет назад +1

      OcRefrigeration,Hvac & Electrical. By chance you happen to any Hoshizaki cover panels? Just tough I’d ask I have a k500 need the top panel, and front

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      No, sorry , i don't keep any old stuff around. Everything to trash or scrap. Sorry for late reply.

  • @FACEYOUTH
    @FACEYOUTH 5 лет назад +1

    Hello sir, I'd like to ask a question. I have an Ice o matic that won't harvest at a little homeless mission I help with. It had the harvest assist probe motor replaced but still no harvest. I checked resistance at coil and its 140, doesnt seem horrible... I hooked up voltmeter and watched for voltage but no voltage ever showed up long past harvest being frozen. What would be next point of diagnosis?

    • @OcRefrig
      @OcRefrig  5 лет назад

      just Follow wires back from solenoid to find power if no power at solenoid.
      usually there are a few parts in circuit, as soon as suction pressure pulls down to approx 28-30 psig low pressure switch should be closed and power coming out of it to timer block( black square thing) it times down and power comes out of that to solenoid usually. there might also be a Yellow cube relay in circuit. remove / inspect cube relay / swap yellow cube relay if u have 2 , they are same.

    • @OcRefrig
      @OcRefrig  5 лет назад

      what city & state are u in ? if your local ill donate my time to help out. im in south orange county, california.

    • @OcRefrig
      @OcRefrig  5 лет назад

      140 ohms is prob ok. you can put power directly to solenoid coil by making a little cord with 2 push ons on the end and plug into a extension cord to test solenoid coil and solenoid valve operation. remove wires to coil then hook your test cord to it. run ice machine, let it make ice when grid is full of ice. plug your test cord into a extension cord and power up hot gas defrost coil. slab of ice should heat up and drop within 2 minutes on the clock. unplug coil after ice drop to re initiate freeze cycle.

    • @OcRefrig
      @OcRefrig  5 лет назад

      there is a Temperature switch on some machines that is a common problem, it is buried under the insulation with 2 black wires coming out of it. it is strapped to a copper refrigeration pipe under the top cover right in front of you.

    • @FACEYOUTH
      @FACEYOUTH 5 лет назад +1

      @@OcRefrig Lol Im in New Orleans, prolly a little too far.

  • @onerussian
    @onerussian 5 лет назад +1

    Oh hey is that a ice500ha2? 🤦🏻‍♂️

    • @OcRefrig
      @OcRefrig  5 лет назад

      no , its a ice0500ha2

  • @jayjaykingbee5566
    @jayjaykingbee5566 6 лет назад +1

    okay 2004 got it, you only told us like 12 times.

    • @OcRefrig
      @OcRefrig  6 лет назад +1

      maybe it was 2005.

    • @MrLamixsoccer
      @MrLamixsoccer 4 года назад

      My friend please just a question so basically what did you replace because that machine was freezing up I have a problem with the same problem I mean machine with the same problem