Step Chimney Flashing 2

Поделиться
HTML-код
  • Опубликовано: 18 дек 2024

Комментарии •

  • @dcp2001
    @dcp2001 15 лет назад +4

    Nice video. This is the difference between the tear down and build new in the US and buildings that are around for hundreds of years, quality of work... Awesome how to demo thanks for posting

  • @peterryan7827
    @peterryan7827 7 лет назад +2

    I have some to do ,and needed to refresh myself on stepflashing i knew the basic ,but have not done it for many years and now ime building a conservatory,and will have to stepflash the pitch and an apron acrros the top ,many thanks loved it.

  • @justlead1
    @justlead1  14 лет назад +2

    @Sweetdreamsprelude
    Hi
    Thanks for your comments. We do use the method you describe and it is less likley to have problems. But step flashing is traditional and in some cases it provides THE LOOK clients like.

  • @thechrissyb
    @thechrissyb 15 лет назад +2

    Yeah i thought exactly that. I normally weld that corner for an extra bit of weather protection. pretty good for diyers to get the gist though.

  • @dozdeshabb
    @dozdeshabb 15 лет назад +2

    thanks very much for sharing and in such details. it really pays to build things properly with good workmanship.

  • @michaelclarke3860
    @michaelclarke3860 11 месяцев назад

    I like the steeper steps, a lovely job sir

  • @bethmeggis
    @bethmeggis 15 лет назад +6

    not fancy but functional, one thing though if you,ve got your disc cutter out you might aswell cut a decent sized joint out instead of a thin cut that you cant point up very well.

    • @puppylife7459
      @puppylife7459 3 года назад +2

      Most cuts are a 1/4 and get silicone, don't want the joint open to much cause then your asking for a leak, and cement doesn't adhere to metal

  • @VeterusTV
    @VeterusTV 12 лет назад +1

    Great video - I'd watch using lead and copper nails because of galvanic corrosion though...

  • @Thedudeabides803
    @Thedudeabides803 7 лет назад +6

    The leak point is very close to where the lead slides into the masonry at the tip of those ugly triangles. Why not have the step go vertically down subsequently overlapping the leak point a couple inches. Man that looks ugly.

  • @ReinaldoPerez-iy6dg
    @ReinaldoPerez-iy6dg 5 месяцев назад

    I'm wondering, how much is a job like that because I need it at my place

  • @simonwalker2533
    @simonwalker2533 10 лет назад +1

    Awesome. Well explained and well executed..

  • @justlead1
    @justlead1  15 лет назад

    Hi. Its a flat lead dresser. Readily available on Ebay uk Good Luck

  • @neroc1
    @neroc1 2 года назад

    excellent video, did you do your own lead welding ?
    I need to do one of these soon and ive not done on in years, this has been a very good reminder , thank you for your time.

    • @justlead1
      @justlead1  2 года назад +2

      Sorry for delay. If your a bit stuck get hold of Just Lead we can chat you through it and supply if needed.

    • @HomeGrownPyro1
      @HomeGrownPyro1 2 года назад

      @@justlead1 do you ship to the USA?

  • @brucedeleskey8540
    @brucedeleskey8540 2 года назад

    But dose it really work

  • @michaeltrimmer8899
    @michaeltrimmer8899 7 месяцев назад

    Never seen a cover flashing g on a chimney front apron,what's the point, the turn into the brickwork joint should be part of the front apron, check out the Lead Sheet Association guidance manuals, also the the front turn on the step flashing should be an angled cut not straight down

  • @justlead1
    @justlead1  14 лет назад

    @tippa2kk
    Do not understand the question?

  • @grubbvictor
    @grubbvictor 11 лет назад +1

    Great presentation.

  • @justlead1
    @justlead1  15 лет назад +1

    @harleyharleyharleyha
    Your a genius. I must rush out and register Just Cement

  • @1longholiday
    @1longholiday 3 года назад +3

    This guy is clearly a proper craftsman. I never understood why the returns are cut back so sharply toward the water line instead of vertically down to the next step. Seems it’s just aesthetics.
    Also never understood why uk step flashing doesn’t incorporate a bend/cover flash over the closest tiles. Surely that would stop the soakers underneath working as hard?

    • @craigsimons817
      @craigsimons817 Год назад

      Cover flashing onto flat tiles or slates will allow driving rain to ingress.
      The soakers are vital to the weatherproofing process and must be correctly fitted.
      Sorry but this gentleman is no craftsman and is bungling the job.
      Do not follow the example he is showing here, consult the British Lead Association for proper and correct information and guidelines, as this sort of thing is skilled work, not to be undertaken by amateurs.

    • @1longholiday
      @1longholiday Год назад

      @@craigsimons817 see part one. There’s soakers under it 😊

  • @malkeetsingh8849
    @malkeetsingh8849 3 года назад

    Well done job

    • @justlead1
      @justlead1  3 года назад

      Thank you, If you can help, I wish to promote Just Lead as we make and deliver sheet lead items through out the UK. www.justlead.co.uk. this link willl show the products we make.

  • @justlead1
    @justlead1  15 лет назад +2

    Thats where we differ i aint cheap

  • @Dieseljonnyboy
    @Dieseljonnyboy 11 лет назад

    A very well done instructional video, ignore the dumb arse comments!

  • @johngulliver6151
    @johngulliver6151 10 лет назад

    Great Job

  • @marcusgriffin4945
    @marcusgriffin4945 8 лет назад +2

    ??????

  • @ThierryLeger389
    @ThierryLeger389 7 лет назад

    super...véry good job

  • @judsonwhitley
    @judsonwhitley 15 лет назад +2

    Wonderful job, but this would never work in the U.S.
    We do not have enough time to do it right. Our time is too valuable. No one would pay the correct amount to flash a chimney according to the way this guy did it.

  • @butchybastad9337
    @butchybastad9337 7 лет назад +2

    Instead of cutting each joint up the side cut a solid channel through the brick at an angle up the side of the chimney for your step flashing cover.will make a much neater job

    • @justycrusty
      @justycrusty 6 лет назад +2

      mike harris
      You’re wrong there mate. This video is 100% correct.
      In very exposed situations the flashings should be cut individually and lapped over one another as they progress up the stack.

  • @johnquinn4151
    @johnquinn4151 3 года назад

    Everyone say you are great flasher

    • @justlead1
      @justlead1  3 года назад

      Just Lead Love flashing

  • @PeakyBlinder
    @PeakyBlinder 15 лет назад +1

    5:49 should of been a strait cut (confusing camera angle) then nip the right hand side of the fold @ a 45d angle.
    its good, but not perfect.

  • @harleyharleyharleyha
    @harleyharleyharleyha 15 лет назад

    why not just like wack some fuckin cement in the corner to stop the water gettin through

  • @ryanthibeau6586
    @ryanthibeau6586 4 года назад

    Why don't u chalk each row of lead before u put in the next one I don't like how u cut the lead on an angle ether u just off material that u could have had for covered

  • @WApnj
    @WApnj Год назад

    That is a terrible way to counterflash. It is not water tight. Wind blown rain gets in at every course.

  • @bigadz46
    @bigadz46 14 лет назад

    pants

  • @harleyharleyharleyha
    @harleyharleyharleyha 15 лет назад

    well whats the point spending more money whe u can just spend less money and save time.. see u cowboys dont know anything til u learn from a proper pro like me

  • @tippa2kk
    @tippa2kk 14 лет назад

    tinman how can u not no what a lead dresser is?

  • @pearlanders
    @pearlanders 13 лет назад

    But you dont use lead 2011. Not very environmentally friendly! :(

  • @TheDaldi8800
    @TheDaldi8800 14 лет назад

    look this vid : "THE REAL ROOFER "
    click on the first vid
    thats quality

  • @naui_diver9290
    @naui_diver9290 4 года назад

    You wanna know how to do a job? Listen to a brit!

  • @mrc8221
    @mrc8221 4 года назад +3

    This may seem like legit lead work to people that haven’t done it, but this is a very bad way of doing a simple lead flashing.