Chimney DPC Tray being fitted.

Поделиться
HTML-код
  • Опубликовано: 19 дек 2024

Комментарии • 45

  • @tidyjob1
    @tidyjob1 2 дня назад

    Excellent I am a bricklayer.and years ago two my my neighbours built their own houses As I did mine. Both. Of my neighbours. Failed. To even put in a lead tray. They both spent a lot of time putting. Clear waterproofing every summer trying. To cure their damp bedrooms.

  • @paulgorman8097
    @paulgorman8097 Год назад

    Thanks for your video, it has been very helpful, comments are also informative. As someone mentioned, I think it makes more sense to leave the color upstand outside the flue instead of inside. One could seal the joint with fire cement from a tube in doing so preserving the integrity of the flue liner.

  • @kevinstreet5709
    @kevinstreet5709 2 года назад +4

    Love the weep hole trick

  • @stevesamoffgridsmallholdin5378
    @stevesamoffgridsmallholdin5378 4 года назад

    I had never realised how much thought has gone into the top of the chimney flashing. Brilliant idea the rope system for drainage.

  • @Ripper36068
    @Ripper36068 4 года назад +1

    always good to watch your vids, Peter. Just a shame they're not better quality

  • @thomashenderson3901
    @thomashenderson3901 4 года назад +2

    Nice trick with the weep holes.

  • @justlead1
    @justlead1  6 лет назад +1

    Hi Clint
    I note your thoughts. Brick built chimneys have been used for many years. We have learned over time that the amount of ventilation / air changes applied to dwellings was far greater in days gone by. Along with loft/attic areas that housed a percentage of chimney, which allowed a natural area of drying that worked well enough with out bringing attention to damp conditions in the habitable parts of properties.
    With changes in lifestyle, Eg. constructing rooms in loft / attic, blocking up fireplaces, reducing air changes to save on fuel. Using less solid fuel heating systems etc. Has made any dampness entering the building visual. In an effort to address the problem sheet lead damp proof course were developed and installed during chimney construction. They work, which allows any water that penetrates the brickwork above the roof line to be denied access to habitable areas.

    • @clinteastwood8230
      @clinteastwood8230 6 лет назад

      Should never block up fire place like if u do u need a vent it . Same as u should never cap over a chimney stack without let it breathe

  • @vivekankolekar7671
    @vivekankolekar7671 2 года назад +2

    Hello Sir
    My builders and building inspectors like to upstand OUTSIDE not inside the liner. This keep liner uninterrupted intact with no gaps .

  • @justlead1
    @justlead1  16 лет назад +3

    Hi. Kempouk i think you may not be familiar with the fitting of DPC trays to chimneys. The purpose being to prevent water entering the building via the exposed brick work. Nothing to do with soakers or indeed the chimney flashing other than using the front section to weather the front apron. As for the dog ear method of folding a corner this is the ONLY situation that it employed, for ease and know aesthetic requirement owing to its position in side the roof.

  • @c6gav
    @c6gav 12 лет назад +2

    it looks neat enaf for me..!! and it worked fine on my new build home..!!

  • @jzarfas
    @jzarfas 3 месяца назад

    Dear Peter, I watched your video a few times on RUclips thanks (: I hope you don't mind me asking you for some advice, I notice may people with ridge chimneys are installing the Lead DPC tray 1 course above the Ridgeline as opposed to below which will happen if the fold downs over aprons are approx 150mm over each side of slates... Is there a reason you know of why folk do this? On our 35 degree roof the 2 sides of Tray that will be folded up would be behind and beneath the saddle flashings. Im wondering if this is why others have put above the ridge ? also it seems in order to fold the 2 sides up, I am not sure on how I would best stop the corners from peeling downwards, unlike the middle section covered by the ridge and then saddle flashing's above. the pics I see of DPC above ridge shows all 4 sides folded down neatly together. Our chimney is on the gable end so the facing bricks continue up wall onto the chimney with barge boards covering it all. I'm trying to work out which will be the best option
    If you or anyone here could spare a moment to advise it would help me no end, best wishes Jamie (:

    • @justlead1
      @justlead1  3 месяца назад

      Hi Please send a a photo or two and I will get backusig email. peterjohnscholey@gmail.com

  • @RobertWewer
    @RobertWewer 11 лет назад +1

    I wish they built them with that kind of pan around these parts. That would be a solution to many troubling seepage leaks. Good video. Thanks!

  • @mgtalbot
    @mgtalbot 9 лет назад

    Terrific video but could you please explain the best way to do lead flashing when a pitched roof butts up against a wall at 90 degrees. The wall is plaster so the lead would be let in the plaster same angle as roof slope but how is the best way to cover ridge tile and should I use 300mm wide lead thanks.

  • @justlead1
    @justlead1  16 лет назад +3

    Hi Thanks is not the be all and end all just the method i use. Good luck

  • @rolandhawken6628
    @rolandhawken6628 2 года назад

    I am assuming you do not put in a DPC like this on a tall 3 meter chimney that will be used constantly for wood coal burning ? I would melt yes ?

    • @paulgorman8097
      @paulgorman8097 Год назад

      This thought crossed my mind also. I think I would put the color outside the liner for that reason. Any further ideas?

  • @anthonydavis5035
    @anthonydavis5035 8 лет назад +4

    and... what will happen when the water in the chimney freezes? won't it expand and destroy the chimney?

    • @mcraigb1
      @mcraigb1 5 лет назад +2

      The whole point of this is for the water to run out the weep holes and not stay in and freeze.

    • @harlekijn007
      @harlekijn007 5 лет назад

      But when it does we keep work

    • @paulgorman8097
      @paulgorman8097 Год назад

      Also, in cold weather, the chimney should be toasty with a good fire below which would minimize the chance of water accumulating but as the video shows the weep holes should take care of it.@@mcraigb1

  • @mcraigb1
    @mcraigb1 5 лет назад

    If I may ask, what does "DPC" stand for?

    • @gazilew
      @gazilew 5 лет назад

      Damp proof course

    • @mcraigb1
      @mcraigb1 2 месяца назад

      @monkeyboy4995 your reply is in line with your name.......

  • @jacobmarmolejo3946
    @jacobmarmolejo3946 5 лет назад

    That's the problem these day's. Want the masons to prevent leaky roofs. Built many from the fire box on up. Alot of overkill today.

  • @wwalk632
    @wwalk632 4 года назад +1

    so what happens when say Beetle ,mud wasp, spider, plugs the drain hole made buy your string - drain ? maybe time to reinvent this concept

    • @paulgorman8097
      @paulgorman8097 Год назад

      the water will still make its way out through the joint between the lead and mortar plus the volume would be minimal in any case.

  • @banjax66
    @banjax66 12 лет назад

    What happens if those two seep holes get blocked with dirt, moss or debris from bird nesting materials etc...

  • @identitywithheld1027
    @identitywithheld1027 4 года назад

    Impressive

  • @clinteastwood8230
    @clinteastwood8230 6 лет назад +2

    If they didn't use cheap bricks and mix the right mortar and sand ratio then they wouldn't need that lead in the stack. Old houses never had it and how much damp do they get down the chimney u could say they used alot of solid fuel back then to dry it out . But still ppl switched to gas and no problems with them. Personally u got a weakness on the bricks as the cement mortsr won't key thst well to the lead u also go the problem of the holes blocking up with moss and that which will grow there cause it's going to be wet

    • @justycrusty
      @justycrusty 6 лет назад

      Clint Eastwood8
      You’re talking bollocks mate. Read the comment from Peter, I agree completely with his response

    • @clinteastwood8230
      @clinteastwood8230 6 лет назад

      @@justycrusty I know far more about it than u mate. New house have a big problem with wrong mix ratios that's y the ridges tiles blow off on newly built house. There no need for that lead in the stack at all plenty of houses don't have it no problems

    • @justycrusty
      @justycrusty 6 лет назад

      Clint Eastwood8
      Oh you reckon?
      Why does the NHBC advocate the use of lead trays through stacks then? Just because chimneys have survived for years without a lead dpc tray at the correct height, doesn’t mean to say they shouldn’t be used. Surely a progressive professional as yourself can appreciate the advantages. Anyway, what do I know after 32 years at it?

    • @clinteastwood8230
      @clinteastwood8230 6 лет назад

      @@justycrusty I can see the other problems it can cause too . Plus it looks very unsightly . There loads of things they bought out on to the market before and then realised its a bad idea cause problems and had to change it

    • @justycrusty
      @justycrusty 6 лет назад +1

      Clint Eastwood8
      I’d rather look at a narrow band of lead around the stack than s big damp psych spreading across the ceiling to be honest. What other products are you talking about?

  • @justlead1
    @justlead1  5 лет назад +1

    Damp proof course

  • @ollie51164lead
    @ollie51164lead 13 лет назад

    Tut, tut new work should be steps, good vid tho, wish brickies would watch something like this, they nearly always fit tray in wrong course.

  • @c6gav
    @c6gav 12 лет назад

    You get up on the roof and fix it..!! Its just like a car it as to have a mot every 12mths..!!

  • @711-v3k
    @711-v3k 4 года назад

    liners in wrong way around, on most flues well done

  • @polska181
    @polska181 6 лет назад

    +hi