Mini Split Multi Zone Pipe Connection HVAC Basics

Поделиться
HTML-код
  • Опубликовано: 25 янв 2025

Комментарии • 44

  • @P9rkour90
    @P9rkour90 6 месяцев назад +1

    This is the kinda of HVAC owner I’d love to work for teach everything he knows, and start my own business! Taddy you are the best in the trade! God bless you. I’ve learned so much from you in these last few weeks it’s insane!

  • @cashonlyj3469
    @cashonlyj3469 3 года назад +1

    Good info Tad I just forwarded it to my son in Colorado he's checking in to this kind of unit.

  • @albmarku4379
    @albmarku4379 2 года назад +1

    Very informative! Great work! Thanks you!

  • @kevinpearce3281
    @kevinpearce3281 Год назад +1

    I only install Lennox equipment. Wish you would make some videos on that stuff.

  • @seantuttle3652
    @seantuttle3652 2 месяца назад

    Yo i got a question for you i got multiple id. units running to multiple od units samsung dvm vrf system ..so here is my question each unit has a thermastat but have 2 even 3 units piped to same port on mcu (branch box) and each thermastat is programmed to same port will that work or cuase commincation issues an eror E201 do i need to wire those units together with one thermastat? To control both or can you have them on separate tstats if its piped together at same port?

  • @LC-qi5ff
    @LC-qi5ff 2 года назад +2

    Do you have 3 separate comm wires from the outdoor to each indoor?

    • @TaddyDigest
      @TaddyDigest  2 года назад +1

      yes absolutely

    • @LC-qi5ff
      @LC-qi5ff 2 года назад +2

      @@TaddyDigest interesting

  • @ace7709
    @ace7709 2 года назад +1

    Id like to get the help guide you referenced

  • @robertrodriguez2514
    @robertrodriguez2514 3 года назад +1

    Good info Tad. I have 4 ton ducted system . Installed by somebody else . I have power to outdoor unit and communication to ducted unit inside with controller . I powered up unit outside but the board does not seem to get any power.

    • @TaddyDigest
      @TaddyDigest  3 года назад +1

      Oh no
      Let me know if you need help
      Click the join button and then send me an email at tadfuller1@gmail.com after you have joined

  • @08yannch
    @08yannch Год назад +1

    question. lest say you have a 5 port Samsung but you only use 3 ports, can you at a later date hook up a 4th line set for another indoor unit?
    would you need to add valves to the spare ports at initial install to facilitate this or does the unit shut off the ports that aren't being used?

    • @TaddyDigest
      @TaddyDigest  Год назад +1

      Yes at a later date you can add another indoor unit
      No you do not have to add any valves

    • @08yannch
      @08yannch Год назад

      @TaddyDigest that's very helpful to know thank you so much

  • @Pau1ys
    @Pau1ys 3 года назад +1

    Taddy, if I have a 9k and An 18k but the 9k is further away than the 18k does the 9k still go on the a connection even though its further away

    • @TaddyDigest
      @TaddyDigest  3 года назад

      Yes the 9K still goes where the 9K goes and the 18K goes where the 18K goes

  • @0527uriel
    @0527uriel 2 года назад +1

    New sub

    • @TaddyDigest
      @TaddyDigest  2 года назад +1

      Thank you for watching 👀 😀 Stay healthy Stay Happy 😊

  • @ore-georgecicovic6533
    @ore-georgecicovic6533 2 года назад +1

    Hi have a guestion. Have only 2 units on outdoor unit that can have 4 heads and indoor units are 22 feet each 15 000 btu both indoor units have 1/2 inch and 1/4 inch pipes. Is it ok using bottom 2 connections since they only fit to indoor flare? Thanks

  • @maldivesmalework945
    @maldivesmalework945 2 года назад +1

    How is pump down gass lock multiple type split AC tell me

    • @TaddyDigest
      @TaddyDigest  2 года назад

      I don't understand your question

    • @maldivesmalework945
      @maldivesmalework945 2 года назад +1

      @@TaddyDigest how to lock gas in multiple split ac oudoor

    • @maldivesmalework945
      @maldivesmalework945 2 года назад +1

      @@TaddyDigest How to lock gas in multiple split ac outdoor, if you want to disconnect an indoor unit, how will the bra restore the gas?

    • @TaddyDigest
      @TaddyDigest  2 года назад +1

      Close the liquid line service valve
      Push the K button until you are in pump down mode read the service manua
      Close the suction line service valve after the low side gauge confirms a low side pressure of 0

    • @maldivesmalework945
      @maldivesmalework945 2 года назад

      @@TaddyDigest thanks you pdf link give me

  • @michomarinoff5299
    @michomarinoff5299 2 года назад +1

    I have this split system but seems like indoor units thermostat is very offset. Showing 68 while every other indoor thermometer shows 72-74. Any idea how to fix this?

  • @mikefarah5752
    @mikefarah5752 2 года назад +1

    It it normal for these units to have some oil in the lines and pressure when opening the port for the first time to make my flare connections? (I know the indoor units come charged with nitrogen)

    • @TaddyDigest
      @TaddyDigest  2 года назад

      always open the vapor line 1st
      Are you asking is it normal

    • @mikefarah5752
      @mikefarah5752 2 года назад +1

      Jw if is normal on the outdoor unit to have a little fluid in the lines? (First time open the port to make my connections)

  • @ianwarren5297
    @ianwarren5297 2 года назад +1

    👏RTFM! Read the f' manual!

  • @jimmybeee5
    @jimmybeee5 3 года назад +1

    I've got a 9000 on a 33' lineset, and a 12000 on a 25' linset. How should I connect these lines to a 2 ton Gree multi outside unit?

    • @TaddyDigest
      @TaddyDigest  3 года назад

      Are the 2 inside heads gree or Samsung
      should be first two ports for the 9 and 2nd set of two ports for the 12

    • @jimmybeee5
      @jimmybeee5 3 года назад +1

      @@TaddyDigestOutside and both insides are Gree. Only info in manuals speaks about line sizes and torque.

    • @TaddyDigest
      @TaddyDigest  3 года назад

      line connections should be 3/8inch and 1/4 inch

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 7 месяцев назад +2

    READ!

  • @hvacandvrvspecialvedoindus7891
    @hvacandvrvspecialvedoindus7891 2 года назад +1

    sir my qualification is Total 6 port pipe canection but your ac 3 pipe xpention valve open .and close telme please ☺️🙏 canected aftar pipe canection pumdon yas o no

  • @foreman4504
    @foreman4504 2 года назад +1

    I have a 3 ton fjm, 2, 18k heads and a 7 head. Line sets were run years ago. The 7 head has a 1/2 od line and a 1/4. I have my longest run in head on bottom or port e, 2nd 18 head on port d and the 7k head is on port c. Went through auto addressing, let unit do its thing. Went inside and tried running 18k unit on port d and get an error code e465 and e464. Any advice or information will be greatly appreciated. Thank you

    • @TaddyDigest
      @TaddyDigest  2 года назад

      I have a guide You should get. Click the join button and send me an email at tadfuller1@gmail.com I will send it to you

  • @victorfernandez6137
    @victorfernandez6137 2 года назад +1

    Exactly- Read the Manual!