Tankless Water Heater Valve kit Tutorial

Поделиться
HTML-код
  • Опубликовано: 22 май 2024
  • Learn how to install your Tankless water heater valve kit.
    More info at www.charmanin.com

Комментарии • 75

  • @WalterBooth-sl9sk
    @WalterBooth-sl9sk 9 месяцев назад +22

    This was an exact replacement for the old one that lasted about 10 years. ruclips.net/user/postUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).

  • @datterboy
    @datterboy 4 года назад +2

    I don't "Give a Like" or "Thumbs Up" often but this video deserves it. Amazingly delivered and explained.

  • @marioludvik4582
    @marioludvik4582 Год назад +1

    Excellent video, it s nice to see that there are still good crafts-men.

  • @Rspartan
    @Rspartan 4 года назад +5

    I watched this a couple of times in preparation for mounting a Navien NPE-180S. There are a lot of comments below about lack of sediment trap on the gas lines, or white teflon tape on the gas line, or using paste in conjunction with tape. The important thing for me is the technique used to install the valves which, btw, is the title of the video. There are plenty of videos on the merits of paste vs. tape, yellow tape for gas lines, how to's on sediment traps, and more - go watch those videos! I apprecicate Charman for putting together this video. Like others below it helped me get my unit ready while highlighting important considerations such as the relief valve, using two wrenches, etc.

  • @susiewood497
    @susiewood497 5 лет назад +7

    I would really love to see you do an instructional video on mounting and venting. You do very very good with detail!

  • @sandman70131
    @sandman70131 5 лет назад +9

    Very nice video but when using Teflon and pipe dope teflon is a thread lubricant to keep threads from binding and pipe dope is a thread sealant what should be applied after Teflon tape, there's also Teflon impregnated pipe dope which can be used by itself. I also noticed during your install there is no drip leg on your gas line before your valve, I felt this was worth mentioning to not only meet code but for safety. in one of these videos I would like to eventually see somebody include the 120 volt connection as well as the thermostat connection and the venting.

  • @neilchandresr.1787
    @neilchandresr.1787 5 лет назад +4

    Thanks, good informative video. This is how i would hook mine up when i get it. My current water is hooked up this way. Other video's show soldering copper connections only, just a pain if you're not an experienced plumber.

  • @WordsPhotos
    @WordsPhotos Год назад

    Thank you for that left right connectors information

  • @ecordy
    @ecordy 5 лет назад +3

    One of the best tutorials. Thank you so much.

  • @ltdan7783
    @ltdan7783 6 лет назад +10

    The dust caps should face outward for connecting the system flush hoses.

  • @syedalam8218
    @syedalam8218 2 года назад +1

    Thanks very informative, God bless you and your family!

  • @susiewood497
    @susiewood497 5 лет назад +2

    Excellent and very informative video!! Very detailed! Very Very helpful!!

  • @jhuh1758
    @jhuh1758 5 лет назад +2

    Excellent and very informative

  • @stevenjohnson626
    @stevenjohnson626 2 года назад +1

    Good job! Nice explanation

  • @ezmirza
    @ezmirza 2 года назад +1

    Excellent video very good explanation and details.

  • @jenmfw
    @jenmfw 4 года назад

    Very good instructions.

  • @ChallengerRT-ld3sk
    @ChallengerRT-ld3sk 4 года назад +3

    This walkthrough is amazing and on point. Thank you!

  • @davidlang8276
    @davidlang8276 2 года назад +1

    Great instructions!

  • @mainavenueprinting8306
    @mainavenueprinting8306 3 года назад

    Wanted to leave my sincere thanks. After watching this tutorial, I feel confident about my diy instal. Great job.

  • @WAY-wr6ur
    @WAY-wr6ur 7 лет назад +4

    Thanks Nice video. It helped a lot. PS. you don't have a sediment trap for you gas line.

  • @leeclark8486
    @leeclark8486 4 года назад +2

    This type A tankless water heater doesn't need or requires a duct for vent.
    There isn't a 120 volts power cord because the appliance probably runs with a couple of two 1.5 volts batteries or it has a hydropower water valve that generates voltage to activate the gas valve and the Sparks module.
    The gas line is missing the safety valve that is supposed to be handy near the unit.

  • @arvinparmar6939
    @arvinparmar6939 3 года назад +2

    I want to buy that valve kit. Please post a link.

  • @dontrunwithscissors9802
    @dontrunwithscissors9802 2 года назад

    can your hot water outake and the pressure valve be combined? I dont have a seperate line for the pressure valve

  • @Jack.333
    @Jack.333 5 лет назад +3

    Good Job
    Plumbers Creed ...If your starting to fight, back off and realign.

  • @henryclarke7045
    @henryclarke7045 Год назад

    Where does the pressure relief valve drain to? Any drain pipe? What circumstances would cause that dangerous increase in pressure? How does flushing work? After you drain the tank what do you do? Where would you attach a filter for sediment or hard water?

  • @EurekaRecycler
    @EurekaRecycler 3 года назад

    Our old on demand / tank-less water heater system is messed up. This one has a recalculation pump. It seem we only get hot water when another hot water tap is open than it seems to heat water fine than after a minute the water flow completely shuts off. If I turn the hot water valve off for a minute or so it will turn on with good flow for about a minute than completely shuts off the water flow. Anyone every had this issue, and how did you fix it ? Thanks

  • @sunnyxiong3560
    @sunnyxiong3560 Год назад

    The thread dope is good enough no more tape is needed

  • @mark.r8900
    @mark.r8900 5 лет назад +1

    hi, do i need to use a reducer coupler 3/4" to 1/2") if my house water line is 1/2" to fit the cold water input side of the service valve? thanks.

    • @shimes424
      @shimes424 4 года назад +1

      Your house main should be 3/4 or bigger or you're not looking at the main trunk

  • @gregorydavison3421
    @gregorydavison3421 5 лет назад +5

    Either paste OR tape on joints surely? Counter productive for either bonding properties...

    • @sandman70131
      @sandman70131 5 лет назад

      Tape is to keep from having threads bind up, paste is a thread sealant. you should be using tape first and paste after if you're going to do it that way, otherwise only use paste by itself.

  • @tj1947
    @tj1947 Год назад

    Shouldn't there be a check valve on the cold water line?

  • @anthonyhitchings1051
    @anthonyhitchings1051 3 года назад

    no flushing connections?

  • @ScolarshipBoy1984
    @ScolarshipBoy1984 4 года назад

    im trying to put this in my house. reserching it ... but why did you put it that high? the tubes make it look ugly? would it be best to doit hidden or theres a reason why it wasent done like that? thanks

    • @dogelife7901
      @dogelife7901 3 года назад +1

      It's not a modern art piece. You have to be able to access those "tubes" to service it every six months, good luck tearing down your walls and not being able to see leaks with your hidden plumbing.

    • @ScolarshipBoy1984
      @ScolarshipBoy1984 3 года назад

      @@dogelife7901 wow makes sence well said ...

  • @theviron6
    @theviron6 6 лет назад +1

    Thanks! what about install with PVC?

  • @frankm2752
    @frankm2752 5 лет назад +2

    Shouldn't you turn to flush position BEFORE you take off the caps?????

    • @sdafasdfasdfsda
      @sdafasdfasdfsda 5 лет назад +1

      The whole point is to attach the hoses first which necessitates taking off the caps prior to turning to flush. Otherwise water from the tank is going to run everywhere instead of in the bucket.

  • @jameswilliams-pn1ee
    @jameswilliams-pn1ee Год назад +1

    Black iron pipe for water feeds ??? Since when ?

  • @russellmartin2705
    @russellmartin2705 3 года назад +2

    No mention of venting or condensate draining?

    • @craigsebring2522
      @craigsebring2522 3 года назад

      No, I wouldn't expect so. The video is called "Tankless Water Heater Valve kit Tutorial" after all.

  • @ervyramirez8839
    @ervyramirez8839 3 года назад

    Como conecto la electrecidad.

  • @worldtouron2wheels22
    @worldtouron2wheels22 5 лет назад

    Where can I get this valve kit?

    • @WakeUpAmerican000s
      @WakeUpAmerican000s 4 года назад

      Look for Webstone valves on the internet. Amazon sells them, as do several plumbing supply houses who have HVAC equipment. There are several different sizes etc. so be sure you get the ones for 3/4 " supply for Tankless Water heaters. A set of the valves for tankless heaters will cost about $80. They are quality made, with two ball valves for each unit (one unit for hot water, one for cold). Well worth it. Then to use them to flush your Tankless heater, go to Harbor Freight tools or a big box store and buy what you need to end up with two 3-4-foot lengths of regular garden hose with a female connector on one end if each, and a $15 small water pump (a submersible pump used for your backyard fish pond works fine ...) Get what ever fitting is needed to connect one of those garden hose pieces to the pump you purchase. (hose barb or whatever). One of those orange Home Depot 5 gal buckets is useful too.
      With the Webstone valves, the pump and two bits of hose, (plus a gallon of vinegar) you've got all you need to easily flush your heater. Turn off your tankless heater. Using the Webstone flush valve, connect the tankless hot water side to your new little pump, and the tankless cold water outlet (the flush outlet on the Webstone valve) to the other hose. Close the big ball valves on the Webstone to isolate the tankless heater, then open both of the flushing valves on the Webstone units. Put both hoses in a bucket with the vinegar and let it circulate for 45-60 minutes. When done, close the cold water flush valve, disconnect your pump from the end of the hot water flushing hose, and open the main valve for cold water to flush out the vinegar from your tankless heater with fresh water.

  • @guloguloguy
    @guloguloguy 2 года назад

    .....One of my favorite activity!.... ("Nipple snugging") Most Americans agree: We NEED "BETTER nipple access!!"....

  • @anthonyhitchings1051
    @anthonyhitchings1051 3 года назад

    for goodness sake, use the teflon tape and toss the paste

  • @paulsmith9574
    @paulsmith9574 2 года назад

    These valve thingys are way expensive. You mean I can't just use a, "T", an in line shut off. Even 2, "T's" Has to be less than $70. What am I missing?

  • @Hever73
    @Hever73 5 лет назад +1

    what about the vent?

  • @bkoz319
    @bkoz319 3 года назад

    tighten em up with a set of channys

  • @2u263
    @2u263 3 года назад

    Excellent clean precise Installation Video, except you dropped your voice volume on a couple of spots. I'll try yo augment it. 🙏.
    Sorry I have 0 Experience do I was hsning on your every word.
    Where does, Scale Retardent Water Filter System Go?

  • @javery50
    @javery50 4 года назад +1

    Forgot to tighten gas line!

  • @donaldmayes2916
    @donaldmayes2916 4 года назад +5

    I think you used the wrong tape on the gas line

    • @tommybokelman5565
      @tommybokelman5565 4 года назад +2

      No such thing it's all the same tape
      Just different colors and thickness
      I'm sure a lot will disagree with me and say yellow is gas , white or blue for water and blablablabla. ITS ALL TEFLON TAPE.

  • @hugoalvarez9805
    @hugoalvarez9805 3 года назад

    Mal. 1 sola llave en la entrada de agua es suficiente. Faltan uniones desarmables también llamadas doble uniones

  • @vettepiper6752
    @vettepiper6752 4 года назад +2

    For heaven's sake people don't use the Teflon tape - Pipefitter for life and experience speaking. Alson the tape manufactures state if your using tape to only apply 1 and 1/2 rounds of it.

    • @imdeplorable2241
      @imdeplorable2241 3 года назад

      I have never seen pipe dope AND teflon tape (5 wraps, too) applied to a single threaded connection before and I've worked with plumbers, steam fitters, boilermakers, and sprinkler fitters for 39 years.
      Was this overkill or is that spec'd by the code?

  • @user-cl7yf9im2w
    @user-cl7yf9im2w 11 месяцев назад

    Not sure about your water connections, but your using the wrong pipe dope & Teflon tape on the Gas connections.

  • @eco_guardian
    @eco_guardian 3 года назад +1

    "nice and perdy..." Ahhhh Americans. Lol

    • @jamietodd2560
      @jamietodd2560 3 года назад

      We're mostly harmless and whimsical.

    • @eco_guardian
      @eco_guardian 3 года назад

      @@jamietodd2560 Haha, tell that to capitol hill

    • @jamietodd2560
      @jamietodd2560 3 года назад

      JustinTrojan “Mostly”

  • @cowlumbus
    @cowlumbus 3 года назад +1

    Terrible placement of valves for access to the cleaning ports down the road. Otherwise great video.

  • @ghostghost8136
    @ghostghost8136 3 года назад

    ITS ILLEGAL TO INSTALL A WATER FLEX LINE ON THE T&P

  • @johnrogan9420
    @johnrogan9420 2 года назад

    Gas....goodbye!

  • @mbrusso01
    @mbrusso01 4 года назад +2

    I don't think so! No sediment trap for the gas? Hack job.

  • @DavidMortaz
    @DavidMortaz 4 года назад

    There is no sound from this clip!! last one played one and I have checked my speakers!!

    • @flyerone
      @flyerone 4 года назад

      David Mortaz check your system as sound comes through nice and clear on my iPad

  • @nelsonbrooks
    @nelsonbrooks 2 года назад

    I can barely hear your narration.

  • @hbseth1867
    @hbseth1867 3 года назад

    Not one valve....... not 2 valves....... 3 valves folks because why not spend your hard earned money on redundancy. Looks cool but I'll go ahead and just use that existing valve down there on the bottom and call it a day. I like breaking rules and pissing people off though so don't listen to me

  • @captaintruth3219
    @captaintruth3219 10 месяцев назад +1

    Now just sit back and get ready for your first electric bill. Our current rate is $.26 per kilowatt hang on. And after about eight months, get the tools back out to disconnect everything again, and flush out all of your lines in your whole house from the build up.🧰🛠️🔧💵💵💵💵💵