Functional Parts Layout an Daikin VRV-4 air-conditioning (A-series)

Поделиться
HTML-код
  • Опубликовано: 28 июл 2024

Комментарии • 131

  • @brandonle4930
    @brandonle4930 2 года назад +3

    Love this version of how you do a break down on the unit. Always looking forward to your video. Thank you for the education.

    • @BonMj
      @BonMj  2 года назад +1

      Thanks bro

  • @RLTVCHANNEL
    @RLTVCHANNEL Год назад +1

    Thanks for your video I learned on refrigeration..

  • @chandrarul365
    @chandrarul365 11 месяцев назад +1

    Hi Boss, I am watching all the video’s so helpful thank you so much I can improve my skills once again thank you so much. Chandr

    • @BonMj
      @BonMj  11 месяцев назад

      👍

  • @goparismail9727
    @goparismail9727 2 года назад +2

    sukses selalu bos ku Bon MJ ilmuya bermanfaat buat teknisi infoneaia🙏🏻🙏🏻🙏🏻🙏🏻 sehat selau

    • @BonMj
      @BonMj  2 года назад

      Terima Kasih master.

  • @ayelwin5894
    @ayelwin5894 6 месяцев назад +2

    Good inspection

    • @BonMj
      @BonMj  5 месяцев назад

      Thanks 👍

  • @ayyanraj6593
    @ayyanraj6593 11 месяцев назад +1

    Thank you sir✌️😊 your videos all are very use ful tips and gifts to technicians and project leaders because they are also learn and gain knowledge ☺️☺️

    • @BonMj
      @BonMj  11 месяцев назад

      Thanks

  • @Kahobbyfarming
    @Kahobbyfarming 2 года назад +1

    Very professional product demostration regarding parts and operation of the equipment,Thanks for the video.

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @salimagwan9672
    @salimagwan9672 2 года назад +2

    You keep making videos like this and keep guiding us thank you mj sir

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @manikandanmani646
    @manikandanmani646 2 года назад +2

    Hi Bro Good job And very useful information 👏🥳👨‍🔧

    • @BonMj
      @BonMj  2 года назад +1

      Thanks bro

  • @matazmataz4287
    @matazmataz4287 2 года назад +1

    Ich bin dir sehr dankbar 😊 und du bist der bester

  • @CCL13984
    @CCL13984 Год назад +1

    Thx,sir !I learned more knowledge by this viedo

    • @BonMj
      @BonMj  Год назад

      👍

    • @CCL13984
      @CCL13984 Год назад

      @@BonMj sir, I have a problem, why I disable whole slave 1, the master unit was error and show UA-54 on display, at same time, the master unit can be normally operation, Which is VRV X7!🙏🙏

  • @wd8557
    @wd8557 2 года назад +1

    More people should do this, god bless you.

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @andyreyes6464
    @andyreyes6464 7 месяцев назад +1

    thank you for the explanation, very wise

    • @BonMj
      @BonMj  7 месяцев назад

      You're very welcome

  • @moorthilatha5739
    @moorthilatha5739 2 года назад +2

    🥰👌👌good explain 👌👌

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @toufikmatib9855
    @toufikmatib9855 2 года назад +1

    Thank you for sharing Bon

    • @BonMj
      @BonMj  2 года назад

      Welcome

  • @BonMj
    @BonMj  2 года назад +1

    CORRECTION
    7:28 minutes Right hand side is Compressor 1 and left hand side is Compressor 2.
    Sorry for the inconvenience.
    Thanks🙏🙏

  • @footballguy4209
    @footballguy4209 Год назад +1

    ❤Thank you Mr.Bon🙏

  • @sivakumar-te5kt
    @sivakumar-te5kt 2 года назад +1

    Good Explanation thank you so much sir

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @queentekindoutama484
    @queentekindoutama484 4 месяца назад +1

    Mr bon your perfect mantapp

    • @BonMj
      @BonMj  4 месяца назад

      Terima kasih

  • @GodofredoTalin
    @GodofredoTalin 2 года назад +1

    Thank you mr. Bon

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @moisesgarcia7708
    @moisesgarcia7708 4 месяца назад +1

    I like you video sir 👍👍👍

    • @BonMj
      @BonMj  4 месяца назад

      Keep watching.Thanks

  • @allanbayten3959
    @allanbayten3959 Год назад +1

    thank you sir bon mj ❤

  • @ahamedwashim5537
    @ahamedwashim5537 Год назад +1

    Thanks 👍

  • @sureshshirsath9325
    @sureshshirsath9325 Год назад +1

    thank you so much sir,...

  • @matazglb5346
    @matazglb5346 2 года назад +1

    Hi, thank you 😊

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @mohamadmosavi1625
    @mohamadmosavi1625 Год назад +1

    Good man
    Thank you

  • @mualacorachgiabestbuy1072
    @mualacorachgiabestbuy1072 2 года назад +1

    Good job

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @karimchiu7527
    @karimchiu7527 Год назад +1

    thank sir Bon

    • @BonMj
      @BonMj  Год назад

      Welcome 🙏🙏

  • @sezginkaradeli3072
    @sezginkaradeli3072 4 месяца назад +1

    Bon mj thank you süper

    • @BonMj
      @BonMj  4 месяца назад

      Always welcome

  • @tapumondol41
    @tapumondol41 9 месяцев назад

    I like your video

    • @BonMj
      @BonMj  9 месяцев назад

      Thanks

  • @hitmankingdom825
    @hitmankingdom825 2 года назад +1

    Thanks you sir

    • @BonMj
      @BonMj  2 года назад +1

      Thanks

  • @karaors8970
    @karaors8970 2 года назад +1

    Hi bro. Super video bon 🤳🛠️👍✋🇹🇷

    • @BonMj
      @BonMj  2 года назад +1

      Thanks master🙏

  • @peramaraj2763
    @peramaraj2763 2 года назад +1

    Good explain sir i would like to know more technical videos sir

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @wandritira1973
    @wandritira1973 3 месяца назад +1

    mantap

    • @BonMj
      @BonMj  3 месяца назад

      Terima Kasih

  • @agusanwar107
    @agusanwar107 2 года назад +1

    thanks Master HVAC

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @imranalam8575
    @imranalam8575 Год назад

    Very appreciated

    • @BonMj
      @BonMj  Год назад +1

      Thanks

    • @imranalam8575
      @imranalam8575 Год назад +1

      @@BonMj sir I want to learn more about inverter technology. I need your opinion if there is any online classes in your platform.

  • @tabresztabu562
    @tabresztabu562 2 года назад +1

    Tq boss ✌️

    • @BonMj
      @BonMj  2 года назад

      Thanks bro

  • @noside8469
    @noside8469 2 года назад +1

    Hello Sir, Uncle Bon,
    Can you also make a video explaining the difference between VRV, VRF and ordinary split 5tr type aircon.
    Watching from the Philippines 🇵🇭🇵🇭🇵🇭💚❤💚❤

  • @popescuvalentin3711
    @popescuvalentin3711 Год назад +1

    😊😊😊

  • @narayanaya5519
    @narayanaya5519 Год назад +1

    Let me know that copper pipe connected near pcb what purpose

  • @narayanaya5519
    @narayanaya5519 Год назад +1

    Please post video about dc fan motor how to check good or defect

  • @lokeshlokeshkumar2107
    @lokeshlokeshkumar2107 2 года назад +2

    Daikin vrv CFM how to check plz explain sir..

  • @user-rc1lu6ig1q
    @user-rc1lu6ig1q 2 года назад +1

    👍👍👍

    • @BonMj
      @BonMj  2 года назад

      谢谢你

  • @sathishkumarsamson3558
    @sathishkumarsamson3558 2 года назад +2

    Hi am working in dubai in VRV 4 E9-3. alarm recived . We replaced EEV and motor as well also we replaced NEW Pcb .but still alaram same .E09-3
    Kindly help me to get solve this problem .

  • @peramaraj2763
    @peramaraj2763 11 месяцев назад +1

    How to find ambient temprature sir ?

  • @janshaw5472
    @janshaw5472 2 года назад +1

    看的头疼,这么多thermistor

    • @BonMj
      @BonMj  2 года назад

      是一套的。

  • @khaidang8614
    @khaidang8614 Год назад +1

    ❤🎉❤🎉

  • @ayyanraj6593
    @ayyanraj6593 11 месяцев назад +1

    Could you please all thermistor actual range sir

  • @amfox8298
    @amfox8298 2 года назад +1

    Sir daikin VRV 4 PCB and senser available please replay me

  • @leelichard5092
    @leelichard5092 2 года назад +1

    Bon,感谢您的技术分享;我刚去荷兰的一家空调公司,我们有大金的系列,这次学到了不少,您是这方面专家,有机会希望可以请教到您。

    • @BonMj
      @BonMj  2 года назад

      谢谢你看我的视频。

  • @andhykafredysasmito4131
    @andhykafredysasmito4131 Год назад +1

    berarti gas sama liquid jadi satu y pak

  • @hashim3062
    @hashim3062 11 месяцев назад +1

    How to reset the LC-14 error alarm? I've tried resetting, always the LC-14 error alarm

    • @BonMj
      @BonMj  11 месяцев назад

      May Pcb faulty

  • @LC-qi5ff
    @LC-qi5ff Год назад +1

    Is gas pipe the suction pipe?

    • @BonMj
      @BonMj  Год назад

      Red for discharge pipe
      Blue for return pipe

  • @Lee-mu2jc
    @Lee-mu2jc 2 года назад +1

    Boss r3t to r6t how many ohm thankyou

    • @BonMj
      @BonMj  2 года назад

      Aound 14K ohm

  • @ronellolpos8668
    @ronellolpos8668 2 года назад +1

    Hello my friend im here in philippines, i got a costumer service call, daiken model RKC35PVM error f3, i just cleaning the condenser but unit run only for just 2days, and now the customer call me again said that the a,c is brinking again, any idea for this my friend

    • @BonMj
      @BonMj  2 года назад

      Check gas pressure
      Check discharge pipe thermistor

    • @ronellolpos8668
      @ronellolpos8668 2 года назад

      @@BonMj gas pressure standing is 250 psig, running pressure of 130psig and amps of 6.58 on clamp meter out 8.28 amps, discharge pipe thermistor is 11 ohms in 37 ambient temp

    • @ronellolpos8668
      @ronellolpos8668 2 года назад

      I am the second technician who check the unit, and according to the customer the first tech finding is eev problem,

    • @brandonle4930
      @brandonle4930 2 года назад +1

      Did you hook up the service checker to see what temperature of the compressor surface area compare to the actually temp? If temperature is incorrect from the service checker compare to your actual check. Replace main PCB

    • @ronellolpos8668
      @ronellolpos8668 2 года назад

      @@brandonle4930 sir, i have only guage manifold and clamp meter

  • @samirfroid3928
    @samirfroid3928 2 года назад +2

    hi sir i have a problem in this vrv (pj 04) please would you help me

    • @BonMj
      @BonMj  2 года назад +1

      Do you replace pcb?

    • @samirfroid3928
      @samirfroid3928 2 года назад

      @@BonMj yes

    • @samirfroid3928
      @samirfroid3928 2 года назад +1

      the old pcb is EB12042(F)
      the new one is EB12042(L)

    • @BonMj
      @BonMj  2 года назад +1

      @@samirfroid3928 may setting not match

    • @samirfroid3928
      @samirfroid3928 2 года назад +1

      @@BonMj Can you give me the special edits because they didn't come with the new PCB EB12042(L) please .

  • @kayodejulius2388
    @kayodejulius2388 2 года назад +1

    How can I bring back the master after bypass

  • @peramaraj2763
    @peramaraj2763 2 года назад +1

    Today just happen sir whenever you free you explain to me VRV-3 one CU 7 nos of FCUs Blinking E3 error code is have after reset all FCUs just CU run up compressor 2 or 3 minute cut off similarly 3 times after MCB trip what is the issue sir please explain.

    • @BonMj
      @BonMj  2 года назад

      Inverter compressor ok?
      Standard compressor ampere?

    • @peramaraj2763
      @peramaraj2763 2 года назад +1

      @@BonMj inverter compressor already faulty standard compressor from 6 to 10 reached within 1 after cut off the compress sir

    • @BonMj
      @BonMj  2 года назад

      @@peramaraj2763 if standard compressor running amps over 10amps consider over current.need to replace compressor or you try wash CU first

    • @peramaraj2763
      @peramaraj2763 2 года назад +1

      @@BonMj standard compressor running amps-19.89 ,low side - 198 psi,high side -360 psi .sir

    • @BonMj
      @BonMj  2 года назад

      @@peramaraj2763 19.8A compressor over current. (Make sure the cu is one inverter and one/two standard compressor)

  • @ANKITKUMAR-qu7vm
    @ANKITKUMAR-qu7vm Год назад +1

    E4 error vrv x

    • @BonMj
      @BonMj  Год назад

      Check pressure

  • @khaidang8614
    @khaidang8614 Год назад +1

    Việt Nam HCM

    • @BonMj
      @BonMj  Год назад

      👍👍