Dear Mr. Louie, Many thanks for your informative video. The fact that the audio is in English as opposed to Tagalog is much appreciated by the non - Filipino seafarers. 🙏🙏
Dear Mr. Louie, This is very informative. Would appreciate if you can clear my one doubt regarding emergency power supply to steering control system on the bridge in case of blackout. My question is, Are both the steering controls connected to emergency switchboard or is it only one connected to ESB just like only one steering motor is connected to ESB?
Please post circuit diagram. What kind of sensors are mounted on rudder to know its position apart from the ones on actuator. What is the coordination between the heading set and actuator movement.
Boss lecky rollsroyes din steering ng barko ko bkit ung hidrolic luck ko nka steady lng ung ilaw n alarm nya,,minsan nwawala nagpalit ako ng solinoid gnun pdin
Normally,, sa solenoid valve and problema ng hydraulic lock.. check mo din ung electrical signal.minsan kailangan i-adjust ung setting ng hydraulic valve block.. check mo sa steering manual ung procedure ng setting.
Dear Mr. Louie,
Many thanks for your informative video. The fact that the audio is in English as opposed to Tagalog is much appreciated by the non - Filipino seafarers. 🙏🙏
It’s fantastic lesson. Really appreciated for your valuable time you for us
thank you sir..keep watching
fantastic work and efforts, please make more videos in such deep details
thankyou
thank you sir..
@@leckylouie looking forward to see more machinery working videos and system operations
Hello, can I ask you a question about the HYDRAULIC lock alarm?
Thank you very much for sharing. Really appreciate your time in doing this video
Glad it was helpful!
Dear Mr. Louie,
This is very informative. Would appreciate if you can clear my one doubt regarding emergency power supply to steering control system on the bridge in case of blackout. My question is, Are both the steering controls connected to emergency switchboard or is it only one connected to ESB just like only one steering motor is connected to ESB?
Hi sir, only one steering gear system is connected to ESB. it is enough to steer ng ship when only Emergency Generator is running.
Please post circuit diagram.
What kind of sensors are mounted on rudder to know its position apart from the ones on actuator.
What is the coordination between the heading set and actuator movement.
What you do in case of an actuator alarm failure, where should you point attention
Low lube oil level alarm activation will enable standby motor to start…u haven’t mention that
you are correct sir that stanby pump will automatically start.
Really you are Great man, thank you very much for your information !!!.
"I wish you long live"
Boss lecky rollsroyes din steering ng barko ko bkit ung hidrolic luck ko nka steady lng ung ilaw n alarm nya,,minsan nwawala nagpalit ako ng solinoid gnun pdin
Normally,, sa solenoid valve and problema ng hydraulic lock.. check mo din ung electrical signal.minsan kailangan i-adjust ung setting ng hydraulic valve block.. check mo sa steering manual ung procedure ng setting.
Sir louie, possible problems po sa boiler pressure line sa hfo. Thanks sir
Really great video.
thank you sir.. keep watching
Good explanation. Thanks a lot.
Thank u for giving us ur valuable time
Thank you, I will follow your channel
thank you sir
thanks! very useful video
Thank you
Hi Sir Leck, make a video about earth faulty monitoring system Low insulation troubleshooting
Thank you for your request.. I will upload a video about 220 low insulation which is a very common problem onboard..
@@leckylouie Thank you Leck 🙏🏻 aspiring ETO someday
Keep watching sir,, most of my video will help those aspiring ETO to understand some common electrical problem onboard.
@@leckylouie noted Leck, more troubleshooting techniques Sir 🙏🏻
Thank You so much.
Sir, pls also make a video about incinerator alarm testing
Well noted Sir.
Helpfull infirmation boss thanks
Welcome
Thanks alot bro Loui...❤❤
is ur salary good?
nice one
Thank you Sir
Very informative vedio
Thanks a lot
Sir pwde safety alarm aux boiler low fo pressure
Nice👍
🎉🎉🎉
Boss i want to communitie with u, how may i get??
Thanks Boss
🎉🎉🎉thanks
Super
Thank you
You're welcome
good
Mostly of chief engr or PSC, not agree with simulation only.
thank you