Marine Boiler: Part 4: Safety device and Auto-Shutdown alarm testing | Alfal Laval | Aalborg Boiler

Поделиться
HTML-код
  • Опубликовано: 28 дек 2024

Комментарии • 45

  • @raquitaguibao6447
    @raquitaguibao6447 2 года назад +1

    mabuhay ka sir,naishare mo ang knowledge mo na magagamit din nmn sa barko. OIC-EW license holder po ako.

  • @johnangelodelacruz8068
    @johnangelodelacruz8068 2 года назад +1

    wow!
    eto yung magandang explenation straight to the point.
    keep it up ka lecky Louie!

  • @gibjiggingadventures2046
    @gibjiggingadventures2046 2 года назад +2

    Thank you for sharing your knowledge Sir Louie! Laking tulong po ito sa amin na may hawak na boiler. Godbless!

    • @leckylouie
      @leckylouie  2 года назад

      Salamat ka-lecky.. keep watching..

  • @MyThilina123
    @MyThilina123 2 года назад

    Sir louie.. You are amazing, you helped us to solve a big problem of our ship.. You helped me to solve the boiler feed water pump start stop problem.. You didn't care about your valuble time.. Finally we got success because of you.. Highly appreciated sir.. Thanks a lot...

  • @pablitojr.tormis7752
    @pablitojr.tormis7752 2 года назад

    Boss lecky salmat sa pag share, hindi ko mahanap part 5,salamat

    • @leckylouie
      @leckylouie  2 года назад

      salamat din boss.. ung part 5 hindi ko pa ma-upload.antay muna ko magandang internet signal..

  • @KarloDelosReyes
    @KarloDelosReyes Год назад +1

    Thank you for sharing your knowledge Sir Louie, may part 5 na po ito Leck?

  • @melvinpadulla1712
    @melvinpadulla1712 2 года назад

    Salamat sir sa video malaking bagay para sa amin,.

    • @leckylouie
      @leckylouie  2 года назад

      Thank You sir, please subscribe and keep watching..

  • @MyThilina123
    @MyThilina123 2 года назад

    Thanks a lot for your kind reply.. I will try to follow as you instructed.. 🙂

  • @DennisRosales-m6n
    @DennisRosales-m6n Год назад

    Leck pwede ka ba magblog ng alarm testing ng safety device ng main engine...Thanks!!!

  • @totirengel6332
    @totirengel6332 Год назад +1

    sir louie tnx po sa video

    • @leckylouie
      @leckylouie  Год назад

      Thank you sir.kepp watching and please subscribe to my channel..😁

  • @ashishjoshi4061
    @ashishjoshi4061 Год назад

    Hi,
    We are facing problme with Mission OL boiler after black out. We are getting alarm "S!B! extended IO link error". And boiler found not starting in Auto. Boiler running satisfactory in Emergency mode. Please advise.

  • @sandynon3569
    @sandynon3569 2 года назад

    The best video.

  • @ricmarvinampongan3973
    @ricmarvinampongan3973 2 года назад +1

    sir pwede burner maintenance at change-over procedure nyo dyan sa alafalaval aalborg OC. thanks sir

    • @leckylouie
      @leckylouie  2 года назад

      Sure.. we'll make it soon. Thank You ka-Lecky and don't forget to subscribe..

  • @junbenarenza4233
    @junbenarenza4233 Год назад

    Sir pano mag carry out ng blowdown surface and bottom in this type of boiler....thank you.

  • @AndreBonDalen
    @AndreBonDalen 8 месяцев назад

    Sir gud evening my some questions lang po sana ako regarding sa boiler

  • @abegailgabriento-coelho5708
    @abegailgabriento-coelho5708 2 года назад

    Sir Lecky naipost po ba ung Part 5 ng boiler? Hnd ko po kc makita. Salamat Sir!

    • @leckylouie
      @leckylouie  2 года назад

      hello po ma'am..hindi ko pa po na post..hindi pa po kasi na tpos ma-edit dahil po medyo naging busy dahil bagong sampa po ulit.. inform po kita pag uploaded na .God bless

  • @MyThilina123
    @MyThilina123 2 года назад

    Sir louie.. We have a big problem. On board.. That is boiler's dp sensor shows the water level on it's screen and the system doesn't.. So, feed water pump won't start or stop automatically, the system shows water level as zero.. That happend after a balckout. The biggest problem. We have to do a watch to fill the boiler manually.. 😢 Now we are so tired of doing this.. Can i have a solution sir.. Please..

    • @leckylouie
      @leckylouie  2 года назад

      Hello,, the posible solution to that problem is in the UNISAB CONTROLLER. after blackout,sometimes you need to input again the setting for water calibration.. if you have a copy of boiler menu tree,you can reconfigure what was the original setpoint for water DP range.. please send me a message to my FB and I will try to assist you.. thank you

    • @leckylouie
      @leckylouie  2 года назад +1

      Sir,in HMI main control panel. In water level menu. What are the setpoints for your normal limit and standby limit? the normal limit (-20) is the in-service feedpump autostart. And the standby limit (-70) is the standby feedpump auto start.. you can check this first sir.

    • @leckylouie
      @leckylouie  2 года назад +1

      Please also check the left Unisab controller inside boiler main control panel. Click menu SET-Up. Then click CALIBRATE. Then click WATER LEVEL. Check what are the setting for RANGE HIGH AND RANGE LOW. take a photo or record it for reference. The range high and low are the reference for your water level indication.. here in my current vessel, the boiler water range high is 312 and the range low is -495. I also encountered this kind or trouble in water level. Maybe you need to recalibrate again this value. By actual or by trial and error.. but our settings are difference.the value here is for your reference only .

    • @leckylouie
      @leckylouie  2 года назад +1

      Before you change any settings..please record it for your reference.. thank you

    • @leckylouie
      @leckylouie  2 года назад +1

      Sir, also try this. Inside the main cabinet, left unisab controller. Go to SET UP, then CONFIG, then ANALOG INPUT. then WATER LEVEL. The setting should be YES to have water level signal for water monitoring.

  • @asopre3664
    @asopre3664 2 года назад

    sir pano naman po kung yung monitor offline galing sa block out pano i reset ? kasi manual kami sa boiler and after block out hindi na namin ma operate sa manual at ang lumalabas sa monitor OFFLINE

    • @leckylouie
      @leckylouie  2 года назад

      Sir, na Experience ko na din yang power panel offline/ local panel offline alarm.. mag pokus ka mag check sa main unisab unit na nasa loob ng panel board.. check mo ung mga settings base sa menu tree settings ng boiler..

  • @jomarchrisoquendo5149
    @jomarchrisoquendo5149 2 года назад

    Shhout out lodi

  • @MyThilina123
    @MyThilina123 2 года назад

    Sir can i have your Facebook profile link please?

  • @MaxKharevsky
    @MaxKharevsky 4 месяца назад

    English please 🙏

  • @subhammondal6294
    @subhammondal6294 2 года назад

    Sir English please

  • @VipVip-wo6vw
    @VipVip-wo6vw 11 месяцев назад

    Speak English