- Видео 78
- Просмотров 238 587
Lecky Louie
Филиппины
Добавлен 3 май 2021
Most of my videos are about my work onboard marine vessel.
Mitsubishi HFO Purifier | Overhauling of Purifier | Vertical and Horizontal Shaft Assembly
Overhauling of Mitsubishi HFO Purifier.
Dismantling of Vertical and Horizontal Shaft, Gravity Disc and Gear Pump.
Dismantling of Vertical and Horizontal Shaft, Gravity Disc and Gear Pump.
Просмотров: 1 036
Видео
Main Engine Alpha Lubricator Magnetic Pick-up sensor Alarm ‖ BCU Pick-up Failure and Replacement.
Просмотров 7764 месяца назад
Music: Alive Musician: @iksonmusic
Provision Crane Slewing Gear ‖ How to replace Crane Slewing Gear and Load Test.
Просмотров 3264 месяца назад
Provision Crane Slewing Gear How to replace Crane Slewing Gear and Load Test.
MARINE INCINERATOR SAFETY ALARM TEST AND AUTOMATIC SHUT-DOWN.
Просмотров 8624 месяца назад
Music: Alive Musician: @iksonmusic
Bosphuros Strait ‖ Experiencing the beauty of Istanbul Strait during Day and Night Transit.
Просмотров 694 месяца назад
Music: See You Musician: @iksonmusic Music: Voyage Musician: @iksonmusic
Helicopter experience from Ship to Shore.
Просмотров 865 месяцев назад
Helicopter experience from Ship to Shore.
Pt100 Resistance Temperature Detector ‖ Replacement and Calculation of Temperature Output.
Просмотров 3525 месяцев назад
Pt100 RTD or Resistance Temperature Detector
Marine Growth Protection System | Copper and Aluminium Anodes | Ship Anti-Fouling System
Просмотров 2,4 тыс.Год назад
Marine Growth Protection System | Copper and Aluminium Anodes | Ship Anti-Fouling System
Ship Annual Survey | What to expect when surveyor is onboard.
Просмотров 3,1 тыс.Год назад
Ship Annual Survey | What to expect when surveyor is onboard.
Ballast Tank Level Sensor | Pressure Transmitters inside ship's pipe tunnel.
Просмотров 949Год назад
Ballast Tank Level Sensor | Pressure Transmitters inside ship's pipe tunnel.
Emergency Generator OFF-LOAD and ON-LOAD TEST. | SOLAS Regulation for Emergency Power Supply.
Просмотров 7 тыс.Год назад
Emergency Generator OFF-LOAD and ON-LOAD TEST. | SOLAS Regulation for Emergency Power Supply.
How to test Main Engine Fuel Oil Leak Alarm Sensor.
Просмотров 1,9 тыс.Год назад
How to test Main Engine Fuel Oil Leak Alarm Sensor.
Portable Fan Motor Overhauling | Burnt internal windings..
Просмотров 405Год назад
Portable Fan Motor Overhauling | Burnt internal windings..
Fishing is one of the best thing that you can do onboard.
Просмотров 162Год назад
Fishing is one of the best thing that you can do onboard.
Boiler Smoke Analyzer | Checking Boiler Efficiency
Просмотров 462Год назад
Boiler Smoke Analyzer | Checking Boiler Efficiency
How to perform GMDSS Radio Batteries Annual Performance Test. | MF-HF Radio console | Back-up Power
Просмотров 3,9 тыс.Год назад
How to perform GMDSS Radio Batteries Annual Performance Test. | MF-HF Radio console | Back-up Power
How to test the Main Engine Oil Mist Detector and replace the Optical Filters of the Measuring Head.
Просмотров 3,8 тыс.Год назад
How to test the Main Engine Oil Mist Detector and replace the Optical Filters of the Measuring Head.
De-greasing and overhauling of Galley Exhaust Fan Motor
Просмотров 729Год назад
De-greasing and overhauling of Galley Exhaust Fan Motor
Duckdalben International Seamen's Club | Hamburg, Germany
Просмотров 144Год назад
Duckdalben International Seamen's Club | Hamburg, Germany
Troubleshooting: 440 volts Low Insulation Alarm from BWTS Lamp Power Supply.
Просмотров 5 тыс.Год назад
Troubleshooting: 440 volts Low Insulation Alarm from BWTS Lamp Power Supply.
How to adjust Battery Charger Voltage Output
Просмотров 822Год назад
How to adjust Battery Charger Voltage Output
Generator Reverse Power Protection Test | Pinoy ETO
Просмотров 9 тыс.Год назад
Generator Reverse Power Protection Test | Pinoy ETO
Water Rafting Adventure at Cagayan De Oro, Philippines / on vacation
Просмотров 59Год назад
Water Rafting Adventure at Cagayan De Oro, Philippines / on vacation
Bridge Telegraph Unit Critical Failure Alarm.
Просмотров 3,1 тыс.Год назад
Bridge Telegraph Unit Critical Failure Alarm.
Deck Air Compressor High Temperature Alarm / Cleaning of Cooling System / Pinoy ETO
Просмотров 1,1 тыс.Год назад
Deck Air Compressor High Temperature Alarm / Cleaning of Cooling System / Pinoy ETO
Steering Gear Safety Devices and Alarm Testing | Pinoy ETO |
Просмотров 17 тыс.2 года назад
Steering Gear Safety Devices and Alarm Testing | Pinoy ETO |
Sir paano Yung dalswang g/e nka parallel tapos pag tsnggalen Ang load Ng Isang g/e nag prefential trip
Thank You Sir,
My experience with Egyptian pilots was bad. From push back it was all the way into airborne - no taxing. Then before landing there was this sharp right corner one would think the runway was there only to continue for another like five kilometres to it. The female hostess was unfriendly. Cairo itself was noisy 24/7 with vehicles scooters and bicycles hooting. Way back the Egyptian airport security was also rough. God forbid i wouldn't want to go back to Cairo.
I am sorry you had a bad experience...the flight I took was as smooth as silk,the crew,helpful ,and since I am Roman,I didn t mind the cheerful noisy streets in Cairo...I wish I could go back,right now
Thanks a lot
Hello friend did you do the blackout in ship for installing the main circuit breaker please tell me..
No, we didnt blackout the ship. the breaker was for ESB and isolated to MSB prior replacement.
Exide battery performance is good and quality also..
Good explanation. Thanks a lot.
thank you sir sa informative information,tanong ko lang yung AC sa control room ayaw lumamig at lagi mataas yung HP side?
pag mataas na ung high pressure ay may problema na cooling system.. try nyo linisan tapos pwede nyo lagyan ng hangin pra matanggal mga kalawang sa linyada. madalas walang problema sa condenser tube.ang problema ay ung inlet at outlet cooling pipe.
How to lap nozzle hull?
❤
ok lang ba tatanggalin ung mga wire kahit naka ahead ung throttle or mamatay ung command ng throttle sa patongo sa engine?
Good video, thanks Lecky 🙏👏👍🤝
thank you very much
Hello from Türkiye. Your videos are really very informative. Thank you for your efforts.🙏 Your channel will grow up i am sure for it. Have a nice day
thank you sir. keep watching
sir good day po! ask ko lang sana yung alborg boiler ko dito, may nag aappear sa touch screen display nya na "comm. error signal" offline 1 parang ganun ang nag aappear sa screen, tapos nilagay ko sa emergency mode pero ayaw mag fire sa emergency mode, ok naman ang oil pressure, sinunod ko naman ang procedure, may ignition naman sya pero ayaw mag fire..hndi umiilaw yung flame scanner indication nya..anything po na maisuggest nyo sa akin sir to solve the problem..thank you.
sir,,paki check mo sa loob ng panel ung controller nya kung may offline 1. try mo muna sir off ung main power ng 5mins then try mo ulit start. check mo isa isa parameters setting sa unisab. sa manual baka meron kayo copy ng parameters setting.minsan kasi nagkaka error ung panel lalo kapag mainit na panahon.
@@leckylouiecge sir check ko bukas, ang init kasi ng panahon ngayon sir kaya cguro nagloloko ang mga electronics..try ko irestart ang nain power bukas.
May video ka sir sa pag charge naman sa air con . Reefer pra sa accomodation
salamat po sa request sir
paano po sir magkuha ng running hours sa ganyan model?
sir,ung running hours namin ay sa ECR alarm computer po namin kinukuha. naka program na po doon at naka~sync ang mga purifier running hours..
Thanks for sharing your knowledge and experience. Please keep sharing troubleshootings.
thank you sir.keep watching
@@leckylouie Alwaysssss👍
Thank you for the impormative video.
keep watching.
Thanks for your vidoe
thank you.keep watching
🎉🎉🎉thanks
🎉🎉🎉thanks
🎉🎉🎉thanks
Sir gud evening my some questions lang po sana ako regarding sa boiler
Please make video in English language sir or English subtitles
noted sir
Name of the vessel please
Really great video.
thank you sir.. keep watching
Suction side ka ng comressor nagkarga sir?
Nice👍
Very good pare. Thanks for education video 👍🏻
Many many thanks
Helpfull infirmation boss thanks
Welcome
fantastic work and efforts, please make more videos in such deep details thankyou
thank you sir..
@@leckylouie looking forward to see more machinery working videos and system operations
It’s fantastic lesson. Really appreciated for your valuable time you for us
thank you sir..keep watching
Thank you. I have a question after I disconnected the supply from the main power in the case of the test.... After the generator starts and supplies the emergency switch board, what will be the fate of the electricity generated during the emergency, because in the case of the examination, the main generator is the one that supplies the power,
Sir, during the test of Emergency Generator, the TIE BREAKER between MSB and ESB will automatically open. then the MSB has still normal power. But the ESB is totally blackout during the test and the back up Emergency generator will start and gives supply to ESB.
Hello friends in AutoChief® C20 Telegraph showing communication error and my printer doesn't got print. Any idea how to resolve and get print on Telegraph printer
You too fast
Great vidoe eto
Sir yung provision plant ko iing ang suction line normal po ba yn ? Malpit na sa compressor
hindi normal yan. baka kulang ng refrigerant or may problema na ung expansion valve. check mo ilan ung suction pressure mo dapat nasa normal limit lage.
Nice one lecky, safe sailing.
thank you sir,, keep.watching
thanks , very clear message
thank you, highly appreciated your comment. keep watching Sir.
thanks so much
Dear Mr. Louie, This is very informative. Would appreciate if you can clear my one doubt regarding emergency power supply to steering control system on the bridge in case of blackout. My question is, Are both the steering controls connected to emergency switchboard or is it only one connected to ESB just like only one steering motor is connected to ESB?
Hi sir, only one steering gear system is connected to ESB. it is enough to steer ng ship when only Emergency Generator is running.
Low lube oil level alarm activation will enable standby motor to start…u haven’t mention that
you are correct sir that stanby pump will automatically start.
Thank you for your job
sir, yung aalborg ko dito palagi flame failure kpag vlsfo at biofuel ang gamit pero kpag diesel wala nman problema..ano po ba ang tamang air/fuel ratio nya para hndi sya mag flame failure?salamat.
pwede mo check sa boiler commision data na nasa manual kung ano air/fuel ration ng boiler nyo. Pwede mo din i try na. babaan muna yung air ratio during firing sequence. Compare mo din ung oil pressure kapag naka.diesel at pag naka vlsfo. madami kasing factor kung bakit sya mag flame failure.
idol pag rack out need pa i off ang acb
for safety reason much better na naka-Off. pero mag automatic OFF din naman kapag rack-out.
Boss paano kng dko mapaabot ng -18 pwd ko bng mag dalawang compresor para maabot nia -18 o -19
pwede gamitan ng dalawang compressor pero base sa makers manual ay maximum of 30mins lang pwedeng i-service ng sabay ang compressor.kung kailangan lang habulin ang room temperature lalo pag bagong lagay ng provision. may connection ang dalawang compressor na pang balancing ng pressure na kailangan buksan pag sabay naka service. pero ang design kasi ay kaya lang ng isang compressor,pag dalawa na.meaning may abnornal sa system.
interesting video. what is the name of this port?
Thanks
Thank you and pls make another video how to setting the 45 sec time relay and point as the located
Thank you, I will follow your channel
thank you sir