  • Siglent updated their user calibration process in firmware V3.01.01.12R1, I show how to calibrate a Siglent Multimeter !
    Siglent watched my previous videos performing the original user calibration process, they listened to my feedback about a better way of doing it and they actually did it ! WELL DONE Siglent !
    New Siglent SDM3065X SDM3055 SDM3045X User Calibration Process
    I really appreciate the donations and support I get from my Patreon Supporters and RUclips Members, donations really do help me to make content for the channel and buy broken test gear, this hobby gets expensive !: defs.link/?u=f...
    #TheDefpom
    #ElectronicsCreators
    #Siglent
    #Repair
    #Electronics
    #TestEquipment
    #Defpom
    ▶ Subscribe: defs.link/?u=f...
    Click the Bell Icon to get notifications about my future videos!
    Affiliate links: (Bookmark and buy using them)
    ▶ Aliexpress: defs.link/?u=5...
    ▶ Banggood: defs.link/?u=5...
    ▶ Amazon Store: www.amazon.com...
    ▶ 👕👚🎽☕ Merchandise: teespring.com/...
    Donate so I can make more videos for you:
    ▶ Become a Patreon!: defs.link/?u=f...
    ▶ Become a RUclips Member: / @thedefpom
    ▶ PayPal Donations: defs.link/?u=b...
    ▶ My Odysee channel: odysee.com/@Th...
    ▶ My Bitchute channel: www.bitchute.c...
    ▶ My Utreon channel: utreon.com/c/T...
    ▶ Test Equipment Repair Videos: • Test Equipment Repair,...
    ▶ Electronics & Repair Videos: • Electronics & Repairs
    ▶ Review & Teardown Videos: • Teardown & Reviews
    ▶ Mailbag / Postbag Videos: • More Mailbag Videos
    ▶ Electronics Projects Videos: • Electronics Projects
    ▶ Apple Repair Videos: • Apple Repairs
    ▶ CB & HAM Radio Videos: • CB & HAM Radio Repair ...
    ▶ My website: www.TheDefpom.com
    ▶ My Twitter: / thedefpom
    ▶ My Thingiverse for 3D printed replacement test equipment parts: defs.link/?u=0...
    ====================
    My Electronics Tools (video and purchase links)
    ====================
    Boonton
    ------
    4220.
    8210: defs.link/?u=e...
    Datron
    ------
    1062: defs.link/?u=4...
    4700: defs.link/?u=e...
    Fluke
    ------
    8842A:
    45: defs.link/?u=e...
    343A: defs.link/?u=1...
    540B: defs.link/?u=0...
    5200A: defs.link/?u=a...
    5450A: defs.link/?u=3...
    Siglent
    ------
    SDM3065X: defs.link/?u=1... defs.link/?u=1...
    SDS1104X-E.
    SDS2102 (hacked to 340MHz): defs.link/?u=1... defs.link/?u=1...
    SDS2104 X Plus.
    SPL-1008.
    SDP1168X: defs.link/?u=1... defs.link/?u=1...
    SDL1020X-E: defs.link/?u=a...
    Other Equipment
    ------
    UNI-T UTi260B Thermal Imager: defs.link/?u=f... (use discount code: BG45411)
    KSGER T12 Soldering Iron: defs.link/?u=6... defs.link/?u=5c...
    Quick 861DW: defs.link/?u=1... defs.link/?u=a...
    Pro'skit SS-331 Desoldering Station: • 🔴 ProsKit SS-331 Desol...
    S-993A: defs.link/?u=0... defs.link/?u=e...
    EEVBlog BM235: defs.link/?u=1...
    YR1030 Battery ESR: defs.link/?u=c...
    Heathkit IT-12 Signal Tracer.
    Racal Dana 1992: defs.link/?u=8...
    Bird 43: defs.link/?u=4...
    Sinadder 3: defs.link/?u=2...
    Audio Control SA-3050A RTA: defs.link/?u=a...
    Korad KA3305D: defs.link/?u=6...
    PDVS2mini: defs.link/?u=8...
    Valhalla 2703: defs.link/?u=0...
    Feeltech FY6800: defs.link/?u=8... defs.link/?u=34...
    Eakins Microscope: defs.link/?u=b... defs.link/?u=2...
    Mustool G600: defs.link/?u=b... defs.link/?u=3...
    Uni-T UT210E: defs.link/?u=3... defs.link/?u=e...
    DER DE-5000: defs.link/?u=0... defs.link/?u=1...
    MK-328: defs.link/?u=0... defs.link/?u=7...
    MESR-100: defs.link/?u=0... defs.link/?u=0...
    ESR Meter: defs.link/?u=0...
    HOPI: defs.link/?u=7...
    PeakMeter PM6252: defs.link/?u=5...
    HS1010: defs.link/?u=1...

Комментарии • 19

  • @schnibbelwind91
    @schnibbelwind91 Год назад

    That's awesome 👍
    Last year I wrote Siglent Support, because the User Calibration on the SDM3055 was faulty. I figured out that the SDM3055 calculated the Values in the mV Range wrong. And the R-Range were impossible to calibrate.
    Coming week I will take the SDM to my work an try to calibrate it with an 8.5 Digit Fluke.

  • @LawpickingLocksmith
    @LawpickingLocksmith Год назад +2

    Geez, you must have South Island's most sophisticated lab.

  • @TonyAlbus
    @TonyAlbus Год назад

    Thanks Scott, yes much better this way!.. thanks for the update

  • @exploozz460
    @exploozz460 Год назад

    Thank you very much for your involvement 👍

  • @AndreyVasilyev
    @AndreyVasilyev Год назад

    Thanks for the important information!

  • @jamesdonaldson7546
    @jamesdonaldson7546 Месяц назад

    Being a newbie, how often should the unit be calibrated? Also, if I do not have another unit to use (like you are doing there), am I dead in the water? I would rather do this myself and not have to send in the unit to pay for calibrating. Thank you for your time!

  • @jamesdonaldson7546
    @jamesdonaldson7546 Месяц назад

    So if you have to use another digital multimeter to calibrate the one that you have, how do you know the other meter is ok itself?? If it wasn't in great calibration itself, then a waste?? Sorry for the novice perspective/newbie perspective. It was just something I was wondering. Your efforts here are indeed brilliant, though.

    • @TheDefpom
      @TheDefpom  Месяц назад +1

      @@jamesdonaldson7546 I am comparing a 6.5 digit meter to a 8.5 digit, so 2 orders of magnitude greater resolution. The 8.5 digit uses artifact calibration based on a 10V reference, which I do have calibration data for, also this is all being generated by a Datron 4700 calibrator who’s output has been verified against other standards I have, so I can have a high confidence level in the calibrator and the 8.5 digit meter accuracy for the purpose of adjusting a 6.5 digit meter.

  • @la7yka
    @la7yka Год назад

    This is great news. I presume the factory calibration still remain stored in case if we mess it all up?

    • @TheDefpom
      @TheDefpom  Год назад +1

      Yes, you can always revert back to the factory cal, in fact if you need to call more than once you should do it based on the factory cal, I found with the previous method that if you did it from the user cal it did it wrong, so best to do it from factory cal.

  • @robertgast5953
    @robertgast5953 Месяц назад

    My SDM3045 is out of spec by a few mv, siglent wants 190 to do a cal/adjust on my sdm3045 that only costs 400! How are you deriving accurate voltages at all those different and specific ranges the meter lists? Most voltages standards are like 5 or 10 volts only. Are you just transferring the readings from the higher accuracy Advantest meter? I would like to be able to do my own cals

    • @TheDefpom
      @TheDefpom  Месяц назад

      @@robertgast5953 I have a Datron 4700 calibrator, I use that to generate the voltages, in this video I have the 8.5 digit meter there for reference.

  • @captiveimage
    @captiveimage Год назад

    The Rigol PSU's have a similar feature, which I really like. Well it does on the Rigol DP832 anyway, so I guess they do it on others too. Manual data point entry is possible, but I don't run this manually on my box. I use PyCharm software and a script (thanks EEVBlog!) that reads the info from my Keysight 34465A and programmatically runs through the cal' sequence. Does the Siglant have this feature too, i.e. you can use 3rd party, or even Siglant software (?) to automate a calibration sequence?

    • @TheDefpom
      @TheDefpom  Год назад +1

      There is a calibration script from Siglent which is based on using a fluke calibrator for automated calibration.

  • @TheEmbeddedHobbyist
    @TheEmbeddedHobbyist Год назад

    What no caps involved at all.

  • @QsTechService1
    @QsTechService1 Год назад

    Is which model of this Meter do you recommend getting ... Also will this display On pc Live readings on the pc ?

    • @TheDefpom
      @TheDefpom  Год назад

      It depends on how much precision you need, the 3045X is probably enough for most people, but the 3055 has some improvements, and the 3065X has a better reference and some extra features.

  • @sanolivo6867
    @sanolivo6867 9 месяцев назад

    I really don't see what is the need for those meters they do nothing for you. Is just a vanity on the bench. Can't even test transistor with them, a $20 bucks tester and bench Brew circuits that cost 0 will do more for you

    • @TheDefpom
      @TheDefpom  9 месяцев назад +2

      If you need to check the accuracy of a lower digit count meter, you need a higher digit count meter… I DO use all the digits when working on higher end test gear, it’s use isn’t for hobbyists where 3 digits is good enough, if you want to test transistors use a transistor tester.