    @SlippsUK 2 года назад +120

    P & T is manual heat or auto temp.
    1 & 2 is 12v or 24v
    H & L is 5000w or 2000w
    1,2 & 8 is the pump size 16ml 22ml or 28ml

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад +8

      Awesome thanks for that mate, it is a huge help

    • @SlippsUK
      @SlippsUK 2 года назад +2

      The only thing I haven't found out is if there's a high altitude mode

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад +6

      @@SlippsUK the symbol comes on when you plug the controller in to the power and then goes off. So maybe it is possible or maybe it comes on automatically when you reach a certain altitude? I t is so hard to find anything on them at all

    • @SlippsUK
      @SlippsUK 2 года назад +5

      @@vanlifesurvivorsguide I do have a manual but it's very badly written

    • @SlippsUK
      @SlippsUK 2 года назад +2

      @jackofalltrades1206 22ml

  • @dunkindiver
    @dunkindiver 2 года назад +13

    So many thanks, spent 3 days trying every combination of button press to enter H OFF mode to do the initial prime. Followed your video and within 30 seconds it was priming!

  • @skrswift
    @skrswift Год назад +6

    You sir are a quite something....thank you for your clear concise vid fixed my problem in a heart beat.

  • @gobbledygook4000
    @gobbledygook4000 Год назад +6

    Thanks so much, the heaters are great the supplied instructions are useless.
    Once again thank you.👍

  • @raredelight4471
    @raredelight4471 2 года назад +10

    Brilliant . Thankyou for taking the time to do this . I was at a complete loss!👍

  • @altitudesickness8682
    @altitudesickness8682 Год назад +5

    Awesome, how do you change it to high altitude mode

  • @johncuthbertson2565
    @johncuthbertson2565 2 года назад +9

    Would never have figured that lot out ....ever!
    Thank you 👍

  • @Tod_Unctious
    @Tod_Unctious 2 года назад +2

    I have the same controller and have spent ages trying to get my pump to purge.
    I was phafing with the ok and down the same as the old controllers. I even tested my pump directly to the battery.
    So happy I found your video I couldn't wait to go and check if I could get the pump to prime.
    Whaheyyy my pump is clicking.
    Thankyou. 👏👏👏👏

    • @adriansykes8735
      @adriansykes8735 Год назад +1

      Hi dave can you explain how you got your pump to start clicking
      I have brand new heater but can't prime

    • @Tod_Unctious
      @Tod_Unctious Год назад

      @@adriansykes8735 hi Adrian if you have the same controller as in this video just follow the instructions.

  • @jamesrooney9822
    @jamesrooney9822 Год назад +2

    Thank you so much for this video it is a great help setting the heater up.
    I was messing around for hours trying to set the unit from the useless instruction booklet.

  • @nvrlate2220
    @nvrlate2220 4 месяца назад +2

    Is there anyway to change clock to 12hr and temp to Fahrenheit?

  • @nateuk2542
    @nateuk2542 2 года назад +7

    Best explanation I’ve seen so far!

  • @SuperDeano1000
    @SuperDeano1000 Год назад

    Thank you! Followed a few videos on how to prime and it wasnt working. Glad you worked it out! Much love.

  • @jrewillis
    @jrewillis 8 месяцев назад +3

    Great video. This controller is a bit different to others and the manual is crap. So thanks for this. I couldnt get mine into thermostatic mode until i watched this. 😊

    • @ShaunyBoy06
      @ShaunyBoy06 2 месяца назад

      Ive got the same unit as this but when I press settings and power mode together it doesn't let me change it from P mode... any ideas?

  • @melindaboyle9648
    @melindaboyle9648 Год назад +2

    Great video. I have this new model lcd with spanner but I’m not able to set Celsius temp at all. Can change the p setting. Any suggestions?

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад +3

      Yeah if you watch it again and the bit where I enter the settings menu where the options are P OR T you can change it there. I think you need to change from P to T if its in T try changing to P

    • @melindaboyle9648
      @melindaboyle9648 Год назад

      @@vanlifesurvivorsguide thanks so much that worked. Another question. We are traveling & the screen is dull. If I knock it it brightens. We went to use first time tonight, pushed ‘on’ the remote, screen brightened, pushed ’on’ again but screen now black & doing nothing. Disconnected plug & reconnected but still black. ???

    • @AdamHolmes-y3o
      @AdamHolmes-y3o Год назад +1

      Struggled for ages best explanation on here thank you

  • @mikewyn7981
    @mikewyn7981 Год назад

    great help this video just bought a heater with this style of control got it heating my house

  • @eddt430
    @eddt430 Год назад +1

    This is awesome thank you..One quick question. Mines all installed today. All working perfectly except the led screen won't power out for. Dim but still there. Any help would be greatly appreciated.

  • @sayton131985
    @sayton131985 2 дня назад

    Is there another sequence for temp over programme? I have a triclicks heater with this controller and I can only get program temps

  • @danielc6034
    @danielc6034 2 года назад +1

    Any idea how to get a switched live? Want to add a fan that only comes on when the heaters running.

  • @fredfred2363
    @fredfred2363 2 года назад +3

    Got the Vevo heater... the triple tap on settings button to get into the 'hidden' menu don't work on mine.
    To prime mine, you have to press (and hold) up and down together.
    Can't figure out the remote or how to set clock. Seems different to all the previous lcd controller models...
    I think they've changed something deliberately.

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад

      hi mate, so on that controller you need to press the power button and the down button at the same time for 2 secs to enter the pairing mode.
      You can pair up to 5 remotes on that controller so you have to choose a number to pair it to between 1 - 5.
      If you want to set it as number 1 you just need to press the "on" button on the remote and it will pair.
      They don't have clocks though that type but do have count down timers to set it to come on in a certain amount of hours and mins up to 99 hours and 99 mins. And then you can set one to go off in a certain amount of hours and mins too

    • @joesmith063
      @joesmith063 2 года назад

      Try taking the fuse out then going directly to pairing

  • @JoseFernandez-zt5xs
    @JoseFernandez-zt5xs День назад

    Thaks a lot with out your help it would've be very hard for me thanks again

  • @tc3imagery
    @tc3imagery 8 месяцев назад +1

    My heater has been running fine for a few hours now, just like many other times, but now suddenly, the “oil pump fault” indicator is on.
    It is the same green indicator that shows up at 0:49 in your video when you begin the priming.
    The manual says about this indicator:
    * the “machine fault“ column refers to that indicator as “oil pump fault“
    * in the “knob panel display“ column it says “4 indicator lights flash” (but this indicator is not flashing on my display, it is just sitting there, solid)
    * in the “handling method“ column, it says “check whether the oil pump is disconnected“ (but my van has not moved a bit, and the heater has not been touched, so I don’t know why or how there could be “oil pump is disconnected”.)
    Hot air is coming out the vent, but I wonder if this “oil pump fault” problem might be making it run not hot enough, or using too much of the diesel, or some other problem.
    Can anybody tell me what problem this symbol indicates might be happening, and what I might do to fix it?
    Thanks!

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  8 месяцев назад +1

      Its not a fault it just means that the pump is on. If it doesn't come on you have a fault. A spanner is the British word for a wrench

    • @tc3imagery
      @tc3imagery 8 месяцев назад

      @@vanlifesurvivorsguidethanks!

  • @skippercaship
    @skippercaship 11 месяцев назад

    Thank you I have just set my heater up thanks to your great video cheers

  • @JamesKinghorn1
    @JamesKinghorn1 Год назад +1

    hey thanks so much for this.def saved me a load of my hairs.
    one things im not sure about is on the temp settings when i go through there are 3 different centigrad settings. 2 with a big C and one with a small c and wondeirng if you know what they mean. thx j

    • @szupek86
      @szupek86 2 месяца назад

      Ambient temp, heat exchanger temp and set temp.

  • @jlindell6532
    @jlindell6532 24 дня назад

    thanks for posting but with the timer _ is it not set by time to go on & off for that day and every day after unless stopped? for example on at 7am and off at 10pm? cheers

  • @DellAnderson
    @DellAnderson 2 года назад +33

    Let's all pause now for a moment of disgust for multifunction interfaces which require puzzle solving skills to operate. Remember when one switch performed one function? Yes, those were the days. This is right up there with those cheap watches no one can ever figure out turn off the alarm that goes off at 3am.

    • @danielc6034
      @danielc6034 2 года назад +2

      :) ^ Brill. I had a watch for about 2 years with a alarm going off in my house. Never found it as it would stop to quick

    • @robertp.wainman4094
      @robertp.wainman4094 Год назад +1

      So true - I couldn't agree more! But I suspect there's actually many people who quite enjoy making things complicated.

    • @whenthesmokeclears9777
      @whenthesmokeclears9777 Год назад

      I'm there..

    • @caddyguy5369
      @caddyguy5369 Год назад

      It really only requires reading comprehension if one reads the manual. :-)
      Video is quicker than finding it or downloading one though.

    • @DellAnderson
      @DellAnderson Год назад +2

      @@caddyguy5369 Nobody said it was rocket science. The issue is why build something simple like a heater that needs an online manual just to operate basic functions. Multifunction buttons are bad user interface design. Only reason it is done: Smaller & Cheaper. I'd pay a few pennies more to have an extra one-button-per-function interface.

  • @7rorre
    @7rorre 2 года назад +4

    Brilliant. The best explanation I' ve come across. Thanks 👍

  • @adrianf101
    @adrianf101 Год назад +1

    Hi what is the purpose of the network bars on the top left of the control?

  • @markkiely8326
    @markkiely8326 Год назад

    glad I found this video cos the instructions I got with my heater were shite

  • @icabobcrane8984
    @icabobcrane8984 6 месяцев назад +1

    Does this controller have alpine mode ?
    If so ,how do you turn it on and off .

  • @paulb8186
    @paulb8186 Год назад +1

    Is there an alpine mode on this controller?

  • @robertp.wainman4094
    @robertp.wainman4094 Год назад +2

    Does anyone know what a red circle with horizontal line in it means? It's started showing in bottom left of screen.

  • @nicholaspargeter6913
    @nicholaspargeter6913 2 года назад +2

    Brilliant video and I have the same controller but mine doesn’t switch the heater modes. I have p 1 to 10. I’m wondering if the controller can be swapped for an up to date version with wifi Bluetooth etc.

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад +1

      Thats annoying, in the video did you see the bit where I entered the pass code to the settings menu? If that works on yours the first option in the menu is p or t so you can switch that to move between modes. P is one T is the other.
      It would be possible if you changed the motherboard and controller at the same time but they are not available anywhere for sale yet so you would need to find one

    • @nickabel8279
      @nickabel8279 Месяц назад

      what ive found so far.
      bureck
      broadlink rm4
      afterburner

  • @flapper111uk
    @flapper111uk 2 месяца назад

    What's the antenna symbol for ?
    Blue lines in top left ??

  • @markm3384
    @markm3384 2 года назад +4

    This is the controller I have, great video for the settings but what I'd really like to know is what the settings in the advanced menu actually do ?

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад +4

      Were on it, not 1005 sure but tomorrow we are going to crack it out again and work it out and film what we know after :)

    • @timkelly5602
      @timkelly5602 2 года назад +2

      Check the pinned post, P or T for power mode (manual) or temperature control, next digit: 1 for 12V, 2 for 24V.... 3rd digit: H for 5K or L for 2K... 4th digit : pump value: 1 for 16ml, 2 for 22ml, 8 for 28ml.... so really nothing you want to change unless using 24v or different pump... given you can choose manual or temperature without going into admin mode... so the values should be set for normal 12v hook up... mine stated P1H2 when i logged in... manual/12v/5KW/22ml pump... so no fan speed and pump setting to play with at all, it seems they are well set up anyhow, so one thing less to do... :) unless of course you grab an afterburner controller (checking circuit board type first)

  • @krystalshocked
    @krystalshocked 2 месяца назад +1

    What is the wireless meter on the controller do?

  • @mattaitchey4917
    @mattaitchey4917 6 месяцев назад

    hi can this style controller (with spanner) be swapped out for the normal universal type?

  • @fozman3875
    @fozman3875 5 дней назад

    Thanks mate great video information

  • @frankish5314
    @frankish5314 Месяц назад

    Thankyou for putting this together. I was hoping that you could tune the air/fuel mixture ratio but it appears this controller does not support this.

  • @susanharvey8298
    @susanharvey8298 Год назад +1

    Hi, I have this control unit, how do I change between 12 volt /24 volt .thanks guys.

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      You need to go into the secret menu like shown in the video with the passcode. Then the first option is the voltage. 1=12v 2=24v. This is just the controller voltage though not the heater voltage. If you have a 24v set up you need a 24v heater

  • @TomBedlammusic
    @TomBedlammusic 11 месяцев назад

    Any idea if you can increase the lower fan speed for higher altitude on this? You could do it on the opder ones in the secret menu but i cant figure it out in this one. Im high in the mountins at the mo and itll shut off randomly from time to time with no error code showing. Figure it needs more air flow

  • @marshallevans2738
    @marshallevans2738 11 месяцев назад

    How do you change the temperature with this controller? Cheers

  • @robbieolson4590
    @robbieolson4590 10 месяцев назад

    How about using the app. I’ve seen a couple videos but I haven’t been able to get it to hook up. In one step they say to press the reset button. Which one is that? Thank you.

  • @Roblovesbushcraft
    @Roblovesbushcraft Год назад +2

    Hi there great vid, best explanation I've seen so far. I wonder if you could tell me how you actually set the desired cabin temp please. I'm sure it obvious but bit not too sure.

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад +2

      Hey, sorry I have only just seen this. You need to go into thermostatic mode so the celsius reading not the power 1-10 reading then set that number to what ever you want the temp to be.
      However the heater will not turn off when the ambient temp of the room reaches the set temp it will just turn down to its lowest power to maintain the heat.
      So if you have a well insulated space it will just keep getting hotter and hotter. For small well insulated space it is best to use power mode and find the sweet spot. This video explains that side of things if you are interested. When the video talks about hz mode it is talking about your p1-10 settings in case it confuses you.
      We also have loads of other helpful diesel heater videos on our channel if you get the time check them out :) ruclips.net/video/uyzIfBwJMWg/видео.html

    • @Roblovesbushcraft
      @Roblovesbushcraft Год назад +1

      @@vanlifesurvivorsguide Ah thst makes sense, I allways thought it was thermostatic and just maintained desired temp.

  • @alfie858
    @alfie858 Год назад +1

    Hi, mine currently has no clock just dashes, no battery symbol at all. None of the buttons seem to work. Before I buy a new one, reckon it's that or the heater? 😁 It has been working fine.

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      its sounds like the connection between the b=controller and wiring loom. have you unclipped it? is it new or have you been using it for a while

  • @4g63tpowered
    @4g63tpowered 11 месяцев назад

    How do i change the temp readout from Celsius to fahrenheit?

  • @bigtarget9709
    @bigtarget9709 Месяц назад

    Absolute lifesaver! Thanks so much!!!

  • @catherinewalsh8613
    @catherinewalsh8613 3 месяца назад

    We have same controller with spanner - just wondering when it turns off it doesn't flash OFF like the other type does, this one flashes CLEA - wondering if that means 'cleaning' instead of off? Starts & runs fine & no fault codes so assuming its not 'clear'?

    • @aaronzwosta5701
      @aaronzwosta5701 2 месяца назад +1

      Just fired mine up today for the first time. I received the same CLEA message when shutting it down. Google was no help. It switched to OFF after a minute or two. Were you able to find out what this means?

  • @trevorjenkins1976
    @trevorjenkins1976 2 месяца назад

    Thanks for the information I've learnt something.
    When turning my unit off, with a long press it comes up with clear.
    Anyone know why?

  • @icabobcrane8984
    @icabobcrane8984 6 месяцев назад +1

    How do you turn the alpine mode , on and off ?

  • @MattParkinson
    @MattParkinson Год назад

    Thanks for this, so many other videos and instructions suggest other buttons for priming etc, spent ages trying to figure this out, not sure why this model is so different? (Triclicks 5kw bought on Amazon). My remote fob was already paired so didnt even need that step.

  • @rusticbro1403
    @rusticbro1403 Год назад

    With the 5 button full function controller, can you change from Celsius to Fahrenheit?

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      you can on this controller, we have another video on our page on how to do it. Other controllers normally no

  • @weymufffisher
    @weymufffisher Год назад

    Do you have to prime every time from cold?

  • @James-yu8nv
    @James-yu8nv Год назад

    Brilliant easy to follow tutorial , thank you!

  • @andrewdart3367
    @andrewdart3367 Год назад

    Does the timer set then work on a 24 cycle ? Thanks

  • @sheerpride
    @sheerpride Год назад

    Many thanks. Watched your video and a few minutes later my heater was up and running. The importer would do well to include a link to your explanation and junk it’s useless manual. That said my heater is working brilliantly now I know the start procedure.

  • @zenith1011
    @zenith1011 11 месяцев назад

    I only have 5 levels of heat. Is there a way to unlock ten? I'd love to be able to turn it down more.

  • @PetesJeepAdventures
    @PetesJeepAdventures Год назад

    Wish it would work. All the buttons you press don’t work on mine. Although it is the same exact controller. Is there a way to reset the whole thing? Then it might work.

  • @حسنحسن-خ7ح1ف
    @حسنحسن-خ7ح1ف 4 месяца назад

    Thank you.... Sir, this device.. to whom is it connected... and what does it do? I know that it is a diesel operating control....

  • @markh4013
    @markh4013 2 года назад +1

    Just got one of these heaters with this controller, everything was just as in this video except I cannot change from temp mode. Pressing power and spanner buttons does absolutely nothing, am I missing something or is it a duff control panel?

    • @nicholaspargeter6913
      @nicholaspargeter6913 2 года назад

      Looks like me and you have the same controller.

    • @timkelly5602
      @timkelly5602 2 года назад +1

      spanner + ok for 3 secs or so... then admin mode by using spanner button to toggle down through time, timer1, timer2, then admin...enter the psw, then ok, then on the 4 digit display, change the t to a P using up or down arrow...

    • @markh4013
      @markh4013 2 года назад +1

      @@timkelly5602 👍 cheers,I'll give that a try

  • @mauriziomaianti9380
    @mauriziomaianti9380 Год назад +2

    Thank you so much for this tutorial!!

  • @Benboxell
    @Benboxell 22 дня назад

    Hello when my heater is running the temperature has gone up to 150°c + what does this mean? Thanks

  • @damenfeld
    @damenfeld Год назад +1

    This video is extremely interesting for me because it shows the same controller that I got with my Triclicks 5kw heater but I cannot make it work in the same way. I want to change it from P-01, P-02, etc to deg C but pressing the buttons you suggest doesn't switch between the power and temp screen as you show.
    Any suggestions on how I can change it from P mode to temp mode?

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      does it have the same logos on it? We have a tutorial of one that came with a triclicks on our channel if you want to take a look it is one of the fist videos we made

    • @damenfeld
      @damenfeld Год назад +1

      Yes, the icons (if that is what you mean by logos) are the same, spanner rather than a settings icon.

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      @@damenfeld Sorry I just read the full comment from before. if it has p mode rather than a hz setting then that means it only has one mode. you cant do much with that type of controller its not a universal one

    • @damenfeld
      @damenfeld Год назад +2

      @@vanlifesurvivorsguide But you showed changing from P Mode to Temp mode on your video? I can't do that on the one I have :( am not looking for the advanced function or Hertz, just the way to change from P mode to temp :)

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      @@damenfeld Does it let you enter a menu with a pass code or can you even get to that screen?

  • @andychibob4889
    @andychibob4889 Год назад +2

    Cool and thanks. I think the changes you make after you put in the code need to be more explained though rather than just you can change that to that. Would be good to find out what changing those does and make an updated video.

  • @raymondreynolds7846
    @raymondreynolds7846 Год назад +1

    I have the same controller; however, nothing happens when I push the spanner and power buttons to switch between modes. Any suggestions?
    I've spend two days trying to fire it up and constantly get failed starts.

    • @anitazuger9617
      @anitazuger9617 Год назад

      We are having the same problem .

    • @joewallauer4345
      @joewallauer4345 Год назад

      I have same looking controller only temp/ set by holding both up and down at same time.

    • @WTGH-sd8hl
      @WTGH-sd8hl 11 месяцев назад

      Just hold spanner for 2 secs on some.

  • @SuperDeano1000
    @SuperDeano1000 3 месяца назад

    Mine doesn't seem to allow me to change the temp setting for some reason. I can change power but not temp. Any suggestions? Thanks 😊

  • @katherineweekes7639
    @katherineweekes7639 Год назад

    Do you know how to set this unit to “altitude mode”?

  • @dtwistrewind7361
    @dtwistrewind7361 Год назад

    Was the last function fan speed so the maximum speed can be lowered to keep the burn chamber hotter?

  • @daiashthomas
    @daiashthomas Год назад

    Is it possible to disable rolling code on these heaters?

  • @wishfix
    @wishfix Год назад

    I had the old type controller on my last heater, I could turn down the fuel to 0.8.
    My heater broke down so I bought a new one, spanner type, Question,, is there any way to turn the fuel down, fan speed down ?

  • @amacmedia3221
    @amacmedia3221 Месяц назад

    Great video.
    I also have this controller and just installed my heater today, just trying it out and plenty heat coming from it after priming it.
    When I go to select OFF I get the message CLEA on the screen, it does power down, just wondering if that is correct though

    • @nickabel8279
      @nickabel8279 Месяц назад +1

      yeah. its clearing out the burner so the unit is ready to run next time. very important step and why they tell you not to just pull the power

    • @amacmedia3221
      @amacmedia3221 Месяц назад +1

      @ many thanks, good to know.
      I’ve got the display showing the temperature but I can’t get it to display the power setting, or are they basically the same thing, as not sure what power mode setting I currently have

    • @nickabel8279
      @nickabel8279 Месяц назад +1

      @@amacmedia3221 I've only been needing with these heaters for 3 be weeks.
      But temp is thermostat mode and p setting is manual. (No on off just puts out that heat level)
      Think it's top two buttons held down to switch?

    • @nickabel8279
      @nickabel8279 Месяц назад

      @@amacmedia3221 oh or 1234 menu. First letter. P for manual. T for temp.
      Don't quote me. Video demonstrates this

    • @amacmedia3221
      @amacmedia3221 Месяц назад +1

      @@nickabel8279 cheers mate, I’ll have a look at this

  • @connellcontracts9270
    @connellcontracts9270 Год назад

    Hi Ive the same controller with the spanner but can't get into the advanced settings when pressing it three times? It seems to be on 24v as I keep getting low voltage

  • @BOSS2GOLDEN
    @BOSS2GOLDEN Месяц назад +1

    Mine come up with E-01 any help no instructions

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Месяц назад

      yes mate low power check out our error codes video as there are a few causes

  • @chrislobb9397
    @chrislobb9397 Год назад

    Thank you for a really helpful video

  • @1bigsyd
    @1bigsyd 2 года назад +1

    Any chance you can do a video on the maXpeedingrods Bluetooth controller

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад +1

      We will do as soon as we can. We don't have the controller at the moment but will have it soon

  • @amacmedia3221
    @amacmedia3221 25 дней назад

    Hi, my heater came on today for no reason, fortunately I was heading out so I noticed, I hadn’t set the timer but wondering how I turn the timer off if I had somehow set it to on

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  25 дней назад +1

      you can just turn the heater off and then that will be it. you have to set it every day so once its come on it needs setting to come on again it wont do it automatically

    • @amacmedia3221
      @amacmedia3221 24 дня назад

      @ excellent, many thanks

  • @tonybaines3332
    @tonybaines3332 2 года назад +1

    how do you change the voltage from 24 to 12

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  2 года назад +1

      Watch the bit where we get into the settings menu with the pin code. The 2nd option is 12v or 24v 1 is 12v or 2 is 24v

  • @MustangBoss1973
    @MustangBoss1973 Год назад +1

    Whats the Wi-Fi icon?
    Has this version got Wi-Fi?

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  Год назад

      It is the remote control radio signal, no it doesn't have wifi.

    • @MustangBoss1973
      @MustangBoss1973 Год назад

      @@vanlifesurvivorsguide thought so thanks for clarifying

  • @jameshead35
    @jameshead35 5 месяцев назад

    Great vid, please add a section on fault codes and explain the purpose of the options in secret menu

  • @jaxsonking26
    @jaxsonking26 2 года назад +2

    I just got mine and it says E-2 and I don’t know what to do or hit to fix it. Iva ran it off a jackery and a lithium battery and both say e-2

    • @timkelly5602
      @timkelly5602 2 года назад

      E02 is over voltage... try a car battery if one available...

  • @LynnRichens
    @LynnRichens 11 месяцев назад +1

    Hello I am getting a E07 code and I cannot figure it out. Can you please help me

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  11 месяцев назад

      Hi yes, it means the controller isn't communicating with the motherboard. Have you changed either recently? Check the connections on the wiring loom are all clipped correctly. Take the connectors apart and make sure the pins inside are straight and not bent. Is it a new or used heater?

  • @grangefarm2
    @grangefarm2 Год назад

    Unable to change from Hertz mode to Centigarde tried pressing Spanner and Power button same time but no luck any ideas! thanks

    • @SquirrelTR23
      @SquirrelTR23 Год назад

      i also have this issue found a fix?

    • @johntartaggia2191
      @johntartaggia2191 Год назад

      On mine, holding down the Settings button (Top left) will change it from deg. to pump rate and back

    • @johntartaggia2191
      @johntartaggia2191 Год назад

      On mine, holding down the Settings button (Top left) will change it from deg. to pump rate and back@@SquirrelTR23

  • @bradleytownsend2294
    @bradleytownsend2294 Год назад +1

    I have the same controller, does anyone know how to set alpine or plateau mode as some call it?

  • @princedemiterios2488
    @princedemiterios2488 2 года назад +1

    Great, Thank You that was very helpfull.

  • @maximoalejandrobudzinski6431
    @maximoalejandrobudzinski6431 6 месяцев назад

    Does anyone know how to decrease the fan speed? Its stucked on MAX. please. Thank you

  • @MrEdde95
    @MrEdde95 Год назад

    Hi! I have a question, maybe you can help. I installed my diesel heater, all good, but every time I start it up it goes trough a procedure, fan starts to run, fuel pump starts to run for a while, firing up and than the fuel pump goes faster and faster, so it does the fan, and only after it slows down to my H1 slow choice. Is that normal, shouldn,t it start with the choosen speed? I have the feeling it always does a selfpriming procedure, with every startup. Thanks!

    • @joewallauer4345
      @joewallauer4345 Год назад

      as I know it ,the fan not only controls the air outside the combustion chamber but inside it,, and a high setting would cool glow plug on startup.

  • @rogerpennington5784
    @rogerpennington5784 Год назад

    How do you change Celsius to Fahrenheit ?

    • @joewallauer4345
      @joewallauer4345 Год назад

      either follow the video/ or use alt method of (up and down buttons at same time) for some models.

  • @mattcooley6157
    @mattcooley6157 2 года назад +9

    Super useful with the pinned comment thanks! Mine came with this and I worked out the 1234 code but had no idea what the rest meant. So I assume all the pulse rates are fixed for each pump size and heater version now?
    Anyone tested whether switching to the 28ml setting on 22ml pump or 2000w setting on a 5000w heater brings the tick rate down and gets a leaner burn? Might be a glitch way to get the missing alpine mode. Seems like they have wised up to people messing with settings and destroying heaters so locked people out of the fan speed and tick rate 😂
    Just to point out both the timers run concurrently, so if you want heater to come on in 1 hour for 2 hours you need to set 01:00 in the first menu then 03:00 in the second. So stupid that the thing has a clock but doesn't let you set by time making us count forward manually. At least it doesn't have the silly hours in decimal controller though!

    • @danielc6034
      @danielc6034 2 года назад +1

      I'm interested to see how to get a leaner burn.
      After seeing many people do videos with the old controller and saying how it keeps the inside clean I think it would be good.
      Wonder if there's a secret secret menu...

    • @mattcooley6157
      @mattcooley6157 2 года назад +2

      @@danielc6034 I don't think they giving access to the pulse rate and fan speed anymore. Probably to many returns because people destroyed heaters! Turning up a fan max rated at 5000rpm to 5000 always was a sure way to kill it quickly. Or 8hz tick rate in a smaller heater. My front room is way bigger than a average garage what these were designed for and hell I'd die if I ran it on p10 for a few hours. That's by dehydration not CO 😂
      I'd like to tone it down a little tbh but I don't think we are getting that in the settings anymore. It's the nature of the beast run large heater under capacity it soots up. Run small heater over capacity it dies. They wised up and made the default settings foolproof...
      But still, turning a 5kw into 2kw does it reduce the tick rate? If you tell it there's a 28ml pump does it tick less to compensate or does it send a bigger charge for a bigger pump and destroy a 22ml?
      Logic tells me they aren't that smart and you'd get the leanest burn by setting 28ml pump in a 2kw heater and it would pump less fuel. But then you could also say set it at 16mil it will pump less fuel because it expected the smaller pump. My head hurts now let's stay warm and CO free 😂

    • @danielc6034
      @danielc6034 2 года назад

      @Matt Cooley :) Thanks. Hopefully these are all questions someone will answer with a bit of time.
      I don't have any tools accurate enough to test these settings.

    • @mattcooley6157
      @mattcooley6157 2 года назад +7

      @@danielc6034 Tested with a click counter app on phone. Does exactly what I though. 2K setting and 28ml pump reduce the tick rate by about 0.3Hz each.
      Default H 22 is 1.6Hz on P1
      L28 is 1.0Hz (Struggles to light)
      H28 1.3Hz
      H16 is about 2.2Hz
      Left mine on 28ml and it's toned the lowest setting down perfectly and maintains temp now rather than increasing

    • @danielc6034
      @danielc6034 2 года назад +1

      @Matt Cooley Amazing! Going to change the pump setting I'm a sec when it stop raining. Mines on p1 at the minute slowly raising but have all the doors shut so smaller space.
      Did you notice fan speed change?

  • @craig2606
    @craig2606 4 месяца назад

    If you need getting e08 after priming check the filler cap is letting air in. I have just worked this out

  • @MrGingerseal
    @MrGingerseal 10 месяцев назад

    I can't seem to change modes out of p-01/10 to •c any help would be great thanks

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  10 месяцев назад

      Hi mate, yeah go into the settings menu using the method and pin code shown in the video and then change the first setting from p to t

  • @oojimmyflip
    @oojimmyflip Год назад

    Ive just got one of these and the special settings menu is confusing to say the least , Ive got other heaters a 5kw and 2kw but ive always tried to get the blue lcd screens that have the code 9009 to access te special settings menu and they give you lots of adjustment of Hz and fan speed settings althougth I didnt find it to healthy to mess about to much as the carbon monoxide enters the hot air stream through the glow plug hole from the glow plug breather as tiny as it is we were getting 33 parts per million in our living area, I ended up using some high temp silicone fire sealent to put around the glow plug rubber cap. fortunately the heater is outside in a custom wooden box bolted to our outside wall. I was going to convert the latest addition to the collection a 5kw heater to the blue screen with the lcd remote but now ive seen your video I might give the screen it came with a try it seems that theirn are some better controls in its special setting menu like being able to run it as a 2kw or 5kw unit. I have noticed that a 2kw needs to be run at around 2.5 Hz for the same heat output as a 5kw at 1.7 hz making the 5kw slightly cheaper to run running the same size 22ml pump. the 5kw minmum setting is 1.7 Hz no matter how low you set the special settings menu on the blue Lcd display.the 2kw will alow you to go as low as 0.9 Hz but this is so low it practically wouldnt heat much of anything.

  • @PAPAwheelie568
    @PAPAwheelie568 3 месяца назад +2

    I’ve watched all of your videos and I still can’t change mine from temperature mode to power mode and it’s very frustrating

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  3 месяца назад +1

      Hi mate, sorry only just seen this i have been in spain. Watch the video again and watch where I go into the hidden menu with the pin code. Then change the first option from p to t. Hope this helps

  • @monkeyflyer410
    @monkeyflyer410 3 месяца назад

    What's the difference between a 3 blade and 6 blade controller?

  • @rikubister6562
    @rikubister6562 2 года назад

    have exact same controller, it seems cannot set hi/low for hertz for tuning up... mine is from vevor 8kw

    • @nicholaspargeter6913
      @nicholaspargeter6913 2 года назад +1

      I don’t think there is such a thing as an 8kw heater. A guy did the math and it’s not possible. You can feed the heater with enough diesel but you can’t run the fan quick enough to cope.

  • @ianrobinson6065
    @ianrobinson6065 2 года назад

    just got one with this control has anyone worked out what hertz the pump runs at with each p value

    • @joncrew6413
      @joncrew6413 Год назад

      I would also like to know this

    • @lessmith8540
      @lessmith8540 Год назад

      Lowest hertz setting is 1.2, this means 1.2 pumps per second, 1.3 is 1.3 pumps per second and so on.

  • @mikeakerstrom1667
    @mikeakerstrom1667 2 года назад +4

    This is not the new version of this controller, it is the older version.
    The dead giveaway that it's the older version is the remote signal displayed at the upper left of the screen.
    Would love to see a real walkthrough of the new control though - can't figure out how to adjust fuel pump/fan speed. I've been using high-altitude mode to get the correct fuel-air mix

    • @SunsetDrift
      @SunsetDrift Год назад

      I would also be interested as I can't adjust the fan speed also, only the temperature?

    • @paulb8186
      @paulb8186 Год назад

      You can't, all that functionality has been taken out. Just basic heat settings including alpine mode and timer/temperature settings.

    • @SunsetDrift
      @SunsetDrift Год назад +1

      @@paulb8186 I've found away to doit.. so you can have the temperature or fan speed settings

    • @petmalumtb1746
      @petmalumtb1746 Год назад

      @@SunsetDrift how did you do it the fan speed work?

  • @1884mray
    @1884mray Год назад

    Ive got the same controller but screen is blank when off but power connected. If I press the on button the heater starts to go through the start up procedure. Any ideas? Thanks

    • @paulb8186
      @paulb8186 Год назад

      Faulty screen/controller, loose connection?

  • @teromustonen2233
    @teromustonen2233 2 года назад

    Thanks, finally i got it to work. 😅🙏👏

  • @nitro.7509
    @nitro.7509 5 месяцев назад +1

    Hi I have just bought one of these and it keeps coming up with e01 error code but it's a brand new battery can anyone help?

    • @vanlifesurvivorsguide
      @vanlifesurvivorsguide  5 месяцев назад +1

      it could be volt drop, the cables to the battery might be too thin. Check out our error codes video

    • @nitro.7509
      @nitro.7509 5 месяцев назад

      Thanks

    • @nitro.7509
      @nitro.7509 5 месяцев назад

      ​@vanlifesurvivorsguide what size cable should it be please?

  • @trevorlewan9227
    @trevorlewan9227 2 месяца назад

    Why does my heater constantly run on max fan speed even though I have it set to the lowest temperature possible?

  • @Diyfix777
    @Diyfix777 9 месяцев назад

    Still trying to find Alpine mode