  • In this video, I have explained how to connect the float switch to water pump with auto and manual selector switch.
    Normally we use auto mode (Float switch connection) for our ease of works. But if float switch damage, we should have another option to operate the water pump. So we can use manual start and stop connection for the water pump. And also Auto-Manual selector switch should be used to change the auto or manual mode.
    If you have any questions, please comment below the video. I will answer your questions.
    Thanks for watching this video.
    PLEASE SUBSCRIBE THIS CHANNEL FOR MORE VIDEOS.
    / @slengineeringacademy2234
    💻Connect with SL Engineering Academy
    🌐Facebook 📲 / sl-engineering. .
    More video
    Float Switch Wiring Diagram for Water Pump/ How to Make Automatic On-Off Switch for Water Pump
    • Float Switch Wiring Di...
    Automatic Changeover Switch for Generator / Automatic Transfer Switch / ATS (With Circuit Diagram)
    • Automatic Changeover S...
    Complete Electrical House Wiring / Single Phase Full House Wiring Diagram
    • Complete Electrical Ho...
    DOL Starter Connection with Indicator | 3 Phase Direct On Line Starter/ Explain with Circuit Diagram
    • DOL Starter Connection...
    Single Phase House Wiring Diagram / Single Phase DB Wiring
    • Single Phase House Wir...
    How to Wire Ceiling Fan and Fan Regulator / Ceiling Fan Connection / Fan Regulator Connection
    • How to Wire Ceiling Fa...
    3 Phase Distribution Board Layout and Wiring Diagram
    • 3 Phase Distribution B...
    Earth Leakage Relay - ELR / How to Wire ELR & CBCT with MCCB / Working Principle of ELR
    • Earth Leakage Relay - ...
    Two Way Switch Connection / How to Wire 2 Way Light Switch / Starecase Wiring with 2 Way Switch
    • Two Way Switch Connect...
    Star Delta Starter for 3 Phase Induction Motor / Star Delta Connection
    • Star Delta Starter for...
    Single Phase Split Type Air Conditioner(AC) Indoor & Outdoor Wiring Diagram/ How to Wire Split AC
    • Single Phase Split Typ...

Комментарии • 71

  • @hetasarvaiya6443
    @hetasarvaiya6443 5 месяцев назад +1

    2 mcb ground earthing magnetic contractors selector switch yellow navy blue manual off auto start emergency switch purple red ground blue black start stop reset yellow black teacher manual off auto float switch power teacher ji

  • @davidhamilton2708
    @davidhamilton2708 Год назад +1

    why not put up a ladder diagram in addition to what you're wiring... I think it would be more helpful , unless all your really after is likes 🤔!!!

  • @venkatfaraday
    @venkatfaraday 9 месяцев назад

    The start switch doesn't work when the tank lowers time in auto mode.float switch is in NO condition always except at lower level.

  • @duykhanhduong5941
    @duykhanhduong5941 10 месяцев назад

    This method is not good, not actual. Because when the shortest water level and highest then pump stop

  • @boopeshkumarprabhakaran
    @boopeshkumarprabhakaran 3 года назад +3

    do video for three phase....will be most helpful

  • @Tsige-im8xb
    @Tsige-im8xb Год назад

    Your vidio is very nice but u r add manual

  • @raj_sumit6942
    @raj_sumit6942 5 месяцев назад

    Please reply me sir models no of magnetic contractor

  • @РусланДеригуз
    @РусланДеригуз 3 года назад +1

    Probably you made mistake. When the water tank has high level you changed contacts of the float switch. It may be common + NC - low level; common + NO - high level. In example you had only one float switch. 4:05 in this video the tank had high level - float switch had switched to common + NC, i think common + NO

  • @keithboland6561
    @keithboland6561 3 месяца назад

    Timer for swimming pool

  • @regineannsalgarino5266
    @regineannsalgarino5266 28 дней назад

    Thank you for sharing

  • @racreativity6093
    @racreativity6093 6 месяцев назад

    Plz make a video using 2 float switch with auto manual selector switch

  • @venkatfaraday
    @venkatfaraday 9 месяцев назад

    I think there is a mistake in this, where is the start switch connection for coil to latch.is that sky-blue wire made in the latch when the green button is pressed?

  • @muhammadshabbir9068
    @muhammadshabbir9068 2 года назад

    Sir omron float less level switch par videos upper and ground tank

  • @sakthivelp1214
    @sakthivelp1214 3 года назад

    If the tank get full,we can start the pump by manual mode..I'm correct...
    But it doesn't start.why???

  • @melchoraquino351
    @melchoraquino351 2 года назад

    Why do you need a start, stop and emergency push button switch when the HOA switch can do the job starting and stopping the motor?
    A good design is one that will do the job safely with less parts.

  • @scropian_gossip
    @scropian_gossip 2 года назад

    good job. Help fully .
    automatic multiport filter valve .backwashing time .tank full but i want on pump

  • @adebayosegun6674
    @adebayosegun6674 27 дней назад

    Great one❤

  • @mr.x3455
    @mr.x3455 2 года назад

    This contactor is 24v or 230vPlease make a video of 24 v contractor

  • @AbuKassimMohdSaleh
    @AbuKassimMohdSaleh Год назад

    Thank you sir, very good lesson and very clear wiring methode

  • @angelofabillar3471
    @angelofabillar3471 2 года назад

    what is the purpose of the botton switch? and thier is no O>L

  • @arifryo6823
    @arifryo6823 2 года назад

    but in auto mode, after the motor stop because float sensor has reach the top level, when we use the water then the level of water is decreased, but this decreased only a little will make the float sensor active again then the motor start, so the motor always working by a little amount of water decreased, so the motor will start stop start stop in just a few minute,.i want to make the motor start working only when the water in tank is real empty..i just cant figured out that witjh this kind of wiring. can any one help me??

  • @djmusickayin6936
    @djmusickayin6936 3 года назад

    how to connect auto & manual for 1 water pump with 2 float switch?

  • @mdrashidali4574
    @mdrashidali4574 2 года назад

    Pls make a video for booster pump control Panel

  • @olakotantimothy334
    @olakotantimothy334 5 месяцев назад

    This song will become evergreen

  • @arunpandit425
    @arunpandit425 2 года назад

    Contactor voltage and amps rating please

  • @zaldytrabado8413
    @zaldytrabado8413 Год назад

    3phase waterpump nmn boss

  • @ginoandrino6366
    @ginoandrino6366 2 года назад

    Boss wiring diagram.. please

  • @izsamaesartegucila383
    @izsamaesartegucila383 3 года назад

    hi if i have .5hp motor pump what ampere to use in breaker and magnetic contactor?

  • @shahilzafar5854
    @shahilzafar5854 3 года назад

    Thanks very much
    Please salector switch se
    Start delta motar Kese Chalti hain
    Auto hand

  • @warrengacho4773
    @warrengacho4773 3 года назад

    Can we replace the magnetic contactor with a 220v relay?

    • @davidhamilton2708
      @davidhamilton2708 Год назад

      A relay does the exact same thing , there is no overloads on a contactor. Yes u can

  • @mayjalhoque3489
    @mayjalhoque3489 3 года назад

    Very nice video and perfect video...👌👍👌

  • @julieanndaitol7227
    @julieanndaitol7227 2 года назад

    TEMPERED( K)

  • @joaquimferreira7324
    @joaquimferreira7324 Год назад

    Legal ❤

  • @abulkalamazad2092
    @abulkalamazad2092 4 года назад

    Kon software diye kaj krecen

  • @mkumusa5414
    @mkumusa5414 3 года назад

    Good job

  • @alimukhtar3384
    @alimukhtar3384 3 года назад

    what is the benefit of it ? it more safe ?

  • @mustaphac714
    @mustaphac714 3 года назад

    Thank you for the explanation, we want a scheme like this with the addition of a floating key at the bottom, meaning we have two tanks, one at the top and the other at the bottom, thank you

    • @slengineeringacademy2234
      @slengineeringacademy2234  3 года назад

      Thanks for watching.❤👍
      Please watch..
      How to Connect 2 Float Switches to Water Pump / Float Switch Connection Explain with Circuit Diagram
      ruclips.net/video/C4BTbNpVBK4/видео.html

  • @ridagaceb7689
    @ridagaceb7689 3 года назад

    Thanks for this video

  • @josephmuthu5773
    @josephmuthu5773 3 года назад

    👌

  • @gasmiichrak4763
    @gasmiichrak4763 3 года назад

    Very good vedio,sir

  • @gaffarholla3608
    @gaffarholla3608 Год назад

    Good job

  • @rkprasadbhookya1878
    @rkprasadbhookya1878 3 года назад

    Really superb

  • @olusolabalogun3092
    @olusolabalogun3092 3 года назад

    I learned a lot

  • @gopurajakannu5461
    @gopurajakannu5461 4 года назад

    அருமை

  • @abulkalamazad2092
    @abulkalamazad2092 4 года назад

    Nice wiring

    • @slengineeringacademy2234
      @slengineeringacademy2234  4 года назад +1

      Thank you..👍❤

    • @juanpangui1007
      @juanpangui1007 4 года назад

      @@slengineeringacademy2234 hola que tal, soy de Argentina, te cuento que empeze a seguir tus videos, queria hacerte una pregunta con respecto a este circuito, si sos tan amable de Responder, el circuito ¿¿Lleva 2 flotadores? o ¿Lleva 1 flotador? Me puedes enviar ami correo electronico el esquema de funcionamiento del video?? Este es mi correo: panguijuandavidnao@gmail.com

  • @antonioguedes1028
    @antonioguedes1028 3 года назад

    MUITO BOM, PARABÉNS!

    • @breckengannon216
      @breckengannon216 3 года назад

      i know im asking randomly but does any of you know of a way to get back into an instagram account..?
      I was dumb lost my login password. I would love any help you can give me.

    • @jasonbeau9773
      @jasonbeau9773 3 года назад

      @Brecken Gannon Instablaster =)

    • @breckengannon216
      @breckengannon216 3 года назад

      @Jason Beau I really appreciate your reply. I got to the site thru google and im in the hacking process now.
      Takes quite some time so I will reply here later with my results.

    • @breckengannon216
      @breckengannon216 3 года назад

      @Jason Beau it did the trick and I now got access to my account again. I'm so happy!
      Thanks so much, you saved my ass :D

    • @jasonbeau9773
      @jasonbeau9773 3 года назад

      @Brecken Gannon You are welcome =)