Installing Symbio Option Modules And Prepping Trane 8.5 Ton Precedent Package Unit For Installation
Просмотров 1,5 тыс.14 дней назад
Checking out a new Trane 8.5 ton Precedent package unit and pre installation setup with electric heater with economizer #hvac #trane #symbio
Almost Lost The Engine In My Subcool Van Heading To A Service Call…This Could’ve Been Bad
Просмотров 1,2 тыс.14 дней назад
This was a close one had it not been for a few circumstances that led up to a problem that could have cost a lot more than it did, Huge Thanks To My Son 👊 #hvac #promaster #automechanic #kaiweets Kaiweets Borescdope Link kaiweets.com/products/kba01-two-way-articulating-borescope?sca_ref=7366987.UARftRCU8A 15% Off Discount Code 15Subcool Amazon 15% off NXD9CZ2N 1-31-25
Cooling Fans Replacement || Why Is The Drive Operating Backwards? .. Toshiba Q9 HVAC Drive
Просмотров 1,1 тыс.21 день назад
Follow up work order to replace Toshiba drive cooling fans the easy way along with figuring out why the drive operates opposite of front switch position #hvac #toshiba #hvacmaintenance
Overpriced OEM Parts $2800! Really? Replacing Outside Air RH/Temp Sensor On Addison RTU
Просмотров 2,4 тыс.21 день назад
Follow up work order to replace a failed OARH/Temp sensor with an OEM replacement.. I’m in the wrong end of the business, these parts are Expensive!! #hvac #airconditioning #expensive
Chiller 1 Will Not Start… Let’s Just Keep Pushing Buttons
Просмотров 4,4 тыс.28 дней назад
Got a call for a RTHD Trane Chiller not able to reset and start, customer doesn’t know what they are doing when it comes to resetting …Thanks for watching!#hvac #chiller #trane
Addison 8 Ton RTU Final Repairs And Start Up : Until Next Year
Просмотров 899Месяц назад
Took a minute to get replacement parts for this Addison unit, the weak link is a rusted snap ring that holds the condenser fan assembly to the motor #hvac #addison #airconditioning
Scotsman Prodigy Ice Machine C0530MA Max Harvest Shut Down Code 2… Not Making Ice
Просмотров 1 тыс.2 месяца назад
Got a work order for a Scotsman Prodigy Ice machine not producing ice and Alarm code 2 Max Harvest Shutdown #icemachine #scotsman #hvacr
Inspecting HVAC Conduit With KAIWEETS KBA01 Borescope: Review and Test
Просмотров 4512 месяца назад
Reviewing a 2 Way Articulating Borescope from Kaiweets KBA01 … #hvac #Kaiweets #Borescope kaiweets.com/products/kba01-two-way-articulating-borescope?sca_ref=7366987.UARftRCU8A Discount Code 15Subcool a.co/d/gmJMngk Amazon 15% off Code NXD9CZ2N Ends 1-31-25
Addison 30 Ton RTU Interface Installation Part No EQT1-4-BNK…Operational Check
Просмотров 9952 месяца назад
Work order to install Equipment Touch interface on Addison RTU .. found a hidden problem. #hvac #airconditioning
Trane Chiller RTHD Water Temp Sensor Upgrade Does Not Go As Planned
Просмотров 2,3 тыс.3 месяца назад
When repairing some non functioning condenser water temp sensors turns out to be more than expected, first time running into this issue #hvac #trane #chiller
Getting Chiller 2 Trane RTHC Back Online And Finding A Hidden Problem
Просмотров 2,9 тыс.3 месяца назад
Got a work order for chillers offline and not restarting after clearing the Alarms #chiller #hvac #airconditioner
Walk In Cooler Not Having A Good Day… Looking For Answers..
Просмотров 2,6 тыс.3 месяца назад
Got a work order for a walk in cooler blowing hot air, food has gone bad… here’s what I found #refrigeration #hvacrepair #cooler
Uniweld MaxEvac 6 CFM Cordless HVAC Vacuum Pump.. 3 Different Battery Brand Options
Просмотров 1,4 тыс.4 месяца назад
Uniweld MaxEvac 6 CFM Cordless HVAC Vacuum Pump.. 3 Different Battery Brand Options
2Yr Old Goodman AC Just Stopped cooling… Aluminum Coil Repair
Просмотров 9024 месяца назад
2Yr Old Goodman AC Just Stopped cooling… Aluminum Coil Repair
Evapco 10hp Cooling Tower Motor Replacement.. This One Tried To Be Difficult
Просмотров 2 тыс.4 месяца назад
Evapco 10hp Cooling Tower Motor Replacement.. This One Tried To Be Difficult
Trane 25 Ton Condensing Unit Blowing Fuses … I Should Have Known
Просмотров 1,9 тыс.4 месяца назад
Trane 25 Ton Condensing Unit Blowing Fuses … I Should Have Known
Klein MOD BOX 54821MB 1 Drawer And 54803MB Medium Drawer Cleaned Up Clutter Area
Просмотров 1,1 тыс.5 месяцев назад
Klein MOD BOX 54821MB 1 Drawer And 54803MB Medium Drawer Cleaned Up Clutter Area
Emergency Work Order .. Tower Fans For Chillers Not Spinning After Early Storm… Steaming Hot
Просмотров 1,7 тыс.5 месяцев назад
Emergency Work Order .. Tower Fans For Chillers Not Spinning After Early Storm… Steaming Hot
Chilled Water Air Handler Making Loud Noise And Not Cooling Properly
Просмотров 2,4 тыс.5 месяцев назад
Chilled Water Air Handler Making Loud Noise And Not Cooling Properly
York YMC2 Magnetic Bearing Excessive Shutdown Alarm…
Просмотров 1 тыс.6 месяцев назад
York YMC2 Magnetic Bearing Excessive Shutdown Alarm…
Chiller In Alarm …Trane CGAM Chiller Comm Loss Faults .. Discharge Temp and EXV
Просмотров 2,6 тыс.6 месяцев назад
Chiller In Alarm …Trane CGAM Chiller Comm Loss Faults .. Discharge Temp and EXV
Carrier RTU 8.5 Ton Not Turning On Affecting The Weight Room… It’s Getting Hot
Просмотров 8 тыс.7 месяцев назад
Carrier RTU 8.5 Ton Not Turning On Affecting The Weight Room… It’s Getting Hot
14yr Old 5 Ton Ruud Iced Up || Customer Prefers To Repair If Possible … Let’s Check It Out..
Просмотров 11 тыс.7 месяцев назад
14yr Old 5 Ton Ruud Iced Up || Customer Prefers To Repair If Possible … Let’s Check It Out..
NAVAC 18v 2 CFM Cordless Vacuum Pump VS HERCULES 20v 2 CFM Brushless HVAC Vacuum Pump
Просмотров 10 тыс.8 месяцев назад
NAVAC 18v 2 CFM Cordless Vacuum Pump VS HERCULES 20v 2 CFM Brushless HVAC Vacuum Pump
Air Handler Blowing Warm Air And Trane RTHD Chiller Leak … Yep That’s Oil
Просмотров 4,4 тыс.8 месяцев назад
Air Handler Blowing Warm Air And Trane RTHD Chiller Leak … Yep That’s Oil
York YMC2 Service Needed || That Doesn’t Sound Good
Просмотров 3,2 тыс.8 месяцев назад
York YMC2 Service Needed || That Doesn’t Sound Good
Condenser Pump And Motor Install With Some York YMC2 Surging Issues
Просмотров 4,3 тыс.8 месяцев назад
Condenser Pump And Motor Install With Some York YMC2 Surging Issues
TRANE Stealth Chiller Circuit 1 AFD 1A Bus Under Volts | Part 2 Results Are In ⚡️🦎
Просмотров 3,4 тыс.9 месяцев назад
TRANE Stealth Chiller Circuit 1 AFD 1A Bus Under Volts | Part 2 Results Are In ⚡️🦎
TRANE RTAE 150 Air Cooled Chiller Circuit 1 AFD 1A Bus Under Voltage Alarm Not Resetting…Part 1
Просмотров 6 тыс.9 месяцев назад
TRANE RTAE 150 Air Cooled Chiller Circuit 1 AFD 1A Bus Under Voltage Alarm Not Resetting…Part 1

Комментарии

  • @mxslick50
    @mxslick50 12 часов назад

    Does your apprentice have his Union card?😅

    • @subcoolHVAC
      @subcoolHVAC 9 часов назад

      I had to leave him on the job🦎

  • @klabkebash
    @klabkebash 18 часов назад

    9:45 - Are those coils Rust colored Red? - Did you soak them with the purple or yellow condenser coil cleaner?

    • @subcoolHVAC
      @subcoolHVAC 17 часов назад

      It’s Heresite coil coating… coils are corroding

  • @klabkebash
    @klabkebash 19 часов назад

    7:10 - Near 400 Head Pressure on R-22 is pretty high. Was it 90 Deg on the inside or something?

  • @bobparrott8130
    @bobparrott8130 4 дня назад

    Nice work

  • @mohsinkhan837
    @mohsinkhan837 4 дня назад

    Have job in US ? I am working in Dubai as a HVAC technician

  • @EverythingHVACR
    @EverythingHVACR 4 дня назад

    😂

  • @PedroHenrique-cu6fq
    @PedroHenrique-cu6fq 4 дня назад

    dont think this new guy is very good, open eyes with him

    • @subcoolHVAC
      @subcoolHVAC 4 дня назад

      He’s a little green still

  • @jeffkleyboecker8190
    @jeffkleyboecker8190 5 дней назад

    It is not Yorks fault totaly the faylt of EMS. Tower pump needs to be controled by the YMC2 . Get that tower water down to 50-55 degrees and let that poor chiller live its best life. EMS should be able to plot rhe KW usage of the tower fans and chiller input KW and see the energy savings by running the tower water colder.

    • @subcoolHVAC
      @subcoolHVAC 5 дней назад

      Yep, if only the weather would stay this cool , it’s just been unseasonably cold this winter. Thanks for the input 👍

  • @HVACTIME
    @HVACTIME 5 дней назад

    Great catch on the pump staging? With the colder weather, have they considered dropping cond temp? With that low of a load the chiller would love about 65F entering condenser water. If its in the 60's outside your wetbulb should be low enough for the towers, even if they struggle in the summer. Thoughts? Back seat driving here.

    • @subcoolHVAC
      @subcoolHVAC 5 дней назад

      That’s a good question, I have a meeting scheduled w/EMS , we’ve had a colder than usual winter and these Yorks are loving it. There’s talk of tower replacement but I don’t see it happening soon, although I’ve been surprised before. Condenser tubes were just cleaned (not really fouled at all) The drift eliminator is in need of replacement if nothing else. Both tower motors operate roughly 5 amp under FLA, my thoughts were have the blades pitched and balance to compensate during Summer , a lot of little things add up. In a month or two it will be full on Tropics weather again here

  • @zekenzy6486
    @zekenzy6486 5 дней назад

    Great video. Thank you for sharing

  • @thesilentonevictor
    @thesilentonevictor 5 дней назад

    Good catch we all learning

    • @subcoolHVAC
      @subcoolHVAC 5 дней назад

      Yes we are, maybe one day I’ll walk in that chiller room and find nothing wrong 😃

  • @BOBKB3NZX
    @BOBKB3NZX 5 дней назад

    I've got to wonder what prompted them to change the behavior profile. It feels like a bean counter said "I can save 5k$ by stopping the pumps right before shutdown."

    • @subcoolHVAC
      @subcoolHVAC 5 дней назад

      The posted sequence of operation only list start up but not shutdown, should be a simple fix in programming

  • @bradwilmot5066
    @bradwilmot5066 5 дней назад

    I hate remotely managed EMS... I run my own. If our company ever decides they want to go with remote management, I'm out of here... I've seen it cause WAY more problems than it solves... "It doesn't work like that" -- "I'm standing in the goddamn machine room and I'm telling you that's what it did... Either unfuck your program or I'll do it with a pair of wire cutters..."

  • @Pippy626
    @Pippy626 5 дней назад

    Why don’t they control the condenser pumps through a relay. York controller can demand what it wants and turn it off properly.

    • @subcoolHVAC
      @subcoolHVAC 5 дней назад

      I prefer that but when the updated controls EMS took this route

    • @joshuaricks7730
      @joshuaricks7730 5 дней назад

      That's also how Trane would like to operate.

    • @subcoolHVAC
      @subcoolHVAC 5 дней назад

      @ for sure 👍

  • @abdullah_q8171
    @abdullah_q8171 5 дней назад

    The new trane microchanel fast leek👎

  • @ThumperKJFK
    @ThumperKJFK 6 дней назад

  • @kellymarieangeljohnson114
    @kellymarieangeljohnson114 7 дней назад

    Thanks for explaining how it all works, I remember we had a cooling tower at my old work place used for cooling 14 Anodising machines. I was told the system used 1 million gallons of water per week was glad I didn't have to pay the water bill!

  • @throttlebottle5906
    @throttlebottle5906 9 дней назад

    I imagine the last guy said, compressor isn't running, it's low on gas, So you need a new system and here's the bid...

    • @subcoolHVAC
      @subcoolHVAC 9 дней назад

      @@throttlebottle5906 That and here’s a price for a service contract… see you in 6 months.

  • @throttlebottle5906
    @throttlebottle5906 9 дней назад

    plastic fantastic and chrysler doing it's usual thing. you're lucky it lasted as long as it did....

    • @subcoolHVAC
      @subcoolHVAC 9 дней назад

      Failure is built into design these days , of course warranty ran out 6 months ago

  • @throttlebottle5906
    @throttlebottle5906 9 дней назад

    "hey where do you want the control box", ""oh I don't know put it over there up high so it doesn't get hit or smashed with anything"". 🤣🤣

    • @subcoolHVAC
      @subcoolHVAC 9 дней назад

      🏀 yep, They play ball in there

  • @JudeHutto
    @JudeHutto 10 дней назад

    Will it detect a leak on copper tubing, example: I just brazed into a unit and my gauges are detecting a leak, could this thing find it for me?

    • @subcoolHVAC
      @subcoolHVAC 9 дней назад

      I have had good experiences detecting r410a and r22 leaks, double check your hose seals and valve seals are not the leak source as well

  • @joshuaricks7730
    @joshuaricks7730 12 дней назад

    Word of advice.....you really have to set fan correctly with those microchannel evaps. They will drip water into the space if it was a vertical config. With this being horizontal, you still will get water in the evap section if not set correctly.

    • @subcoolHVAC
      @subcoolHVAC 12 дней назад

      Thanks for the advice 👍

    • @joshuaricks7730
      @joshuaricks7730 12 дней назад

      @subcoolHVAC you do great work brother. Love the channel.

    • @subcoolHVAC
      @subcoolHVAC 12 дней назад

      I appreciate that 👊

  • @brushben22
    @brushben22 12 дней назад

    I have that same unit at a facility, we have changed the ECM motor twice in 9 years. You need to remove the top, get a ladder and spend a ton of money to get that motor. Worst thing Trane has done

    • @subcoolHVAC
      @subcoolHVAC 12 дней назад

      @@brushben22 I fully expect that since one of the items listed in IOM is supply fan failure if not up to 30rpm within 40sec it shutdown.

  • @zekenzy6486
    @zekenzy6486 13 дней назад

    Great video. Thank you for sharing

  • @kwestreef8938
    @kwestreef8938 13 дней назад

    From all brands Trane labels and schematics are the worst, most will fade out in the first year. Nice vid by the way 👍

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      Yep, the schematic is the mercy of a ziplock bag on the inside panel.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 13 дней назад

    Nice simple little unit. Got to enjoy thise days

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      Yeah, grateful for low stress day 👍

  • @davidnull5590
    @davidnull5590 13 дней назад

    Wooo, those are expensive Trane 8.5 Ton Precedent Package Unit, the ones I can easily find are around $11,600 plus shipping. At that price they better last a lifetime.

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      @@davidnull5590 Yeah, that’s a good estimate. Is 10 years asking too much 😉

  • @polishsharpshooter2876
    @polishsharpshooter2876 13 дней назад

    Absolute trash. God speed my man.

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      We’ll never be without work

  • @stevencossaboon3237
    @stevencossaboon3237 13 дней назад

    Nice work Subcool.

  • @EverythingHVACR
    @EverythingHVACR 13 дней назад

    Nicely done, thanks Subcool.

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      Thanks Steve, I Appreciate the feedback!

  • @topher8634
    @topher8634 13 дней назад

    I'm installing a 7.5T split where I work now. Didn't know you had to have an option module just to use the strips. They didn't say anything when we got the quote. With Reliatel, all you ever had to do was cut the jumper to enable them.

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      @@topher8634 yeah, I had to remove the jump and install on P4 and from P5 to the OA module P5. First time dealing with Symbio but from what the Installation sheet looks like what they want.

    • @Jeremy-gt8xf
      @Jeremy-gt8xf 13 дней назад

      Symbio is the epitome of overly complicated controls & poor QC. Haven't had a single startup that didn't have a factory issue.

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      @Jeremy-gt8xf I fully expect some type of issue , might be installer error on my part 😂

  • @abdullah_q8171
    @abdullah_q8171 13 дней назад

    Both compressor are deference 1 is big than other why ?

    • @colossalsky
      @colossalsky 13 дней назад

      There probably different stages, or one is a compressor and one is a receiver.

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      2 stages

    • @davidnull5590
      @davidnull5590 13 дней назад

      If I remember correctly, one compressor is about 1/3 of the cooling (maybe a little bit more); the other compressor is about 2/3 of the cooling.

  • @erniejack3723
    @erniejack3723 13 дней назад

    do the 454b regs go with commercail applications ???

    • @subcoolHVAC
      @subcoolHVAC 13 дней назад

      Residential/light commercial Any manufactured after January 1, 2025 will be A2L, dealers can sell r410a units mfg prior still . Trane will use r454b from what I understand

    • @EverythingHVACR
      @EverythingHVACR 13 дней назад

      Yessir 454B with RDS mitigation

  • @thesilentonevictor
    @thesilentonevictor 14 дней назад

    Good video)

  • @PorkChopAChunky
    @PorkChopAChunky 17 дней назад

    First mistake was buying a dodge. Second mistake was keeping it. Don't make a 3rd😂

    • @subcoolHVAC
      @subcoolHVAC 17 дней назад

      Guilty 😂 although ROI wasn’t bad for 5yrs

    • @PorkChopAChunky
      @PorkChopAChunky 17 дней назад

      @subcoolHVAC Don't feel to bad, I have a LML duramax that has nearly bankrupted me with emissions parts. I'm in so deep I just can't sell it

    • @subcoolHVAC
      @subcoolHVAC 17 дней назад

      @PorkChopAChunky Thanks, I feel better.

  • @Yrersw
    @Yrersw 17 дней назад

    Oh no!

  • @AlbertPlante-z5q
    @AlbertPlante-z5q 17 дней назад

    Nice to know we have a mechanic in the family

  • @Ericbakereb1
    @Ericbakereb1 17 дней назад

    Try crayon wax. Learned that trick from a RUclips mechanic. Thanks for the update bud

    • @subcoolHVAC
      @subcoolHVAC 17 дней назад

      Oh yeah, I saw that. Will give it a try. Thanks 👊

  • @topher8634
    @topher8634 17 дней назад

    The oil cooler on those Pentastars are notorious for failure. Usually fail around 50K. Also the water drainage is an issue on the Pro masters and Ford's Transit vans. Usually end up shorting the coils out.

    • @subcoolHVAC
      @subcoolHVAC 17 дней назад

      Thanks for the info , got that leak sealed 🤞

  • @pomonabill220
    @pomonabill220 18 дней назад

    You have gorgeous eyes! That was nice that your son helped and you didn't try and drive your van without oil! THAT would have been a disaster! I really like your videos. Great content and good detail! Thank you.

    • @subcoolHVAC
      @subcoolHVAC 17 дней назад

      @@pomonabill220 Thanks for watching 👀

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 18 дней назад

    Props to your son....he saved the day....proud dad moment there

    • @subcoolHVAC
      @subcoolHVAC 18 дней назад

      Thanks Jason! Yes he did, and saved a big repair bill 💵

    • @thesilentonevictor
      @thesilentonevictor 18 дней назад

      Good job fixing your own alongside your son

    • @subcoolHVAC
      @subcoolHVAC 18 дней назад

      @thesilentonevictor Thanks, he definitely saved time and $.

  • @Nefstar
    @Nefstar 20 дней назад

    “Outstanding” ✅

    • @subcoolHVAC
      @subcoolHVAC 19 дней назад

      Thanks for Watching 👍

  • @jamesvegas7203
    @jamesvegas7203 21 день назад

    ABB > Toshiba

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 21 день назад

    That sucker was dirty....when you blew it out....i was damn....how has that drive survived this long....kudos to you. Enjoyed the video 😊

    • @subcoolHVAC
      @subcoolHVAC 21 день назад

      Everything at that same level was covered in dust, cleaning services must only go up to 8ft high😀

  • @thesilentonevictor
    @thesilentonevictor 21 день назад

    I just find things are not serviceable anymore

    • @subcoolHVAC
      @subcoolHVAC 21 день назад

      It could have been more service friendly for sure

  • @topher8634
    @topher8634 21 день назад

    One of the main killers of VFDs

  • @ThumperKJFK
    @ThumperKJFK 22 дня назад

  • @ccthepope
    @ccthepope 22 дня назад

    Great video!

    • @subcoolHVAC
      @subcoolHVAC 22 дня назад

      @@ccthepope Thank you for watching!

  • @stevencossaboon3237
    @stevencossaboon3237 22 дня назад

    Nice work Subcool, thank you for the knowledge.

  • @mxslick50
    @mxslick50 22 дня назад

    Oops, commented too early. But still, a head's up: Most drives have a parameter setting that electrically reverses the motor. It allows a lazy installer to reverse rotation without swapping motor wires. It is usually disabled by default. An extensive power down, faulty memory keep alive supercap/battery, or power surge can toggle that parameter when the drive is powered back up. Another thing that causes that is static electricity, which could have happened when you blew the drive out in the truck. Early versions of some Damnfussy drives were prone to that and defaulting to full factory parameters.

    • @subcoolHVAC
      @subcoolHVAC 22 дня назад

      @@mxslick50 yep, in this case the drive operated when bypass selected on front panel and bypass when drive selected.,