Installing Symbio Option Modules And Prepping Trane 8.5 Ton Precedent Package Unit For Installation

Поделиться
HTML-код
  • Опубликовано: 10 фев 2025
  • Checking out a new Trane 8.5 ton Precedent package unit and pre installation setup with electric heater with economizer #hvac #trane #symbio

Комментарии • 33

  • @zekenzy6486
    @zekenzy6486 18 дней назад

    Great video. Thank you for sharing

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 18 дней назад

    Nice simple little unit. Got to enjoy thise days

    • @subcoolHVAC
      @subcoolHVAC  18 дней назад +1

      Yeah, grateful for low stress day 👍

  • @EverythingHVACR
    @EverythingHVACR 19 дней назад

    Nicely done, thanks Subcool.

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад +1

      Thanks Steve, I Appreciate the feedback!

  • @stevencossaboon3237
    @stevencossaboon3237 19 дней назад

    Nice work Subcool.

  • @thesilentonevictor
    @thesilentonevictor 19 дней назад +2

    Good video)

  • @kwestreef8938
    @kwestreef8938 18 дней назад

    From all brands Trane labels and schematics are the worst, most will fade out in the first year. Nice vid by the way 👍

    • @subcoolHVAC
      @subcoolHVAC  18 дней назад

      Yep, the schematic is the mercy of a ziplock bag on the inside panel.

  • @joshuaricks7730
    @joshuaricks7730 17 дней назад

    Word of advice.....you really have to set fan correctly with those microchannel evaps. They will drip water into the space if it was a vertical config. With this being horizontal, you still will get water in the evap section if not set correctly.

    • @subcoolHVAC
      @subcoolHVAC  17 дней назад

      Thanks for the advice 👍

    • @joshuaricks7730
      @joshuaricks7730 17 дней назад

      @subcoolHVAC you do great work brother. Love the channel.

    • @subcoolHVAC
      @subcoolHVAC  17 дней назад

      I appreciate that 👊

  • @topher8634
    @topher8634 19 дней назад

    I'm installing a 7.5T split where I work now. Didn't know you had to have an option module just to use the strips. They didn't say anything when we got the quote. With Reliatel, all you ever had to do was cut the jumper to enable them.

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад

      @@topher8634 yeah, I had to remove the jump and install on P4 and from P5 to the OA module P5. First time dealing with Symbio but from what the Installation sheet looks like what they want.

    • @Jeremy-gt8xf
      @Jeremy-gt8xf 19 дней назад +1

      Symbio is the epitome of overly complicated controls & poor QC.
      Haven't had a single startup that didn't have a factory issue.

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад

      @Jeremy-gt8xf I fully expect some type of issue , might be installer error on my part 😂

  • @brushben22
    @brushben22 18 дней назад

    I have that same unit at a facility, we have changed the ECM motor twice in 9 years. You need to remove the top, get a ladder and spend a ton of money to get that motor. Worst thing Trane has done

    • @subcoolHVAC
      @subcoolHVAC  18 дней назад

      @@brushben22 I fully expect that since one of the items listed in IOM is supply fan failure if not up to 30rpm within 40sec it shutdown.

  • @erniejack3723
    @erniejack3723 19 дней назад

    do the 454b regs go with commercail applications ???

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад +1

      Residential/light commercial Any manufactured after January 1, 2025 will be A2L, dealers can sell r410a units mfg prior still . Trane will use r454b from what I understand

    • @EverythingHVACR
      @EverythingHVACR 19 дней назад

      Yessir 454B with RDS mitigation

  • @davidnull5590
    @davidnull5590 19 дней назад

    Wooo, those are expensive Trane 8.5 Ton Precedent Package Unit, the ones I can easily find are around $11,600 plus shipping. At that price they better last a lifetime.

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад

      @@davidnull5590 Yeah, that’s a good estimate. Is 10 years asking too much 😉

  • @abdullah_q8171
    @abdullah_q8171 19 дней назад

    Both compressor are deference 1 is big than other why ?

    • @colossalsky
      @colossalsky 19 дней назад +1

      There probably different stages, or one is a compressor and one is a receiver.

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад

      2 stages

    • @davidnull5590
      @davidnull5590 19 дней назад +1

      If I remember correctly, one compressor is about 1/3 of the cooling (maybe a little bit more); the other compressor is about 2/3 of the cooling.

  • @polishsharpshooter2876
    @polishsharpshooter2876 19 дней назад

    Absolute trash. God speed my man.

    • @subcoolHVAC
      @subcoolHVAC  19 дней назад

      We’ll never be without work