Pipe Fitting Basics

Поделиться
HTML-код
  • Опубликовано: 15 дек 2024
  • One element of Pipe Fitting Basics is learning pipe fitting take-off dimensions available from all manufacturers of fittings. If you're trying to figure out what size piece of pipe you'll need for a center to center dimension, you'll need two key numbers.
    In this video, I break down the "correct way" of getting those dimensions but I also throw in some real-world experience I've put into practice on this long journey as a service plumber. There are many more Pipe Fitting Basics you'll need to know to be a successful plumber, this is just the beginning!
    Regards & Happy Plumbing!
    Bob
    Calculated Industries 4020 Measure Master Pro Feet-Inch-Fraction and Metric Construction Math Calculator amzn.to/3gSmlOj
    Lost Art Of Steam Heating amzn.to/2WJxdqF
    My Amazon Storefront:
    www.amazon.com...
    Disclaimer:
    My Videos are provided for informational purposes only. All material provided within this website is for informational, educational, & entertainment purposes only. Some of these projects, materials, and techniques may not be appropriate for all ages or skill levels. The plumbing instruction used here is used to simply break down jobs into their simplest steps.
    Please use a clear mind and use all safety precautions following the tutorials provided by this site. I do not make any claims of the safety of the projects, techniques, or resources listed on this site and will not take responsibility for what you do with the information provided by this site.
    Viewers must be aware by doing projects on their homes they are doing it at their own risk and Bob's Plumbing Videos cannot be held liable if they cause any damage to their homes.
    With different codes around the world and constantly changing standards, regulations, and rules, it is the sole responsibility of the viewer to educate themselves on their local requirements before undertaking any sort of project. That being said Bob's Plumbing Videos cannot claim liability with all applicable laws, rules, codes, and regulations for a project. Be safe, have fun with your plumbing repairs, and ALWAYS stay informed with your local building code.
    *NOTE: This description above contains affiliate links that allow you to find the items mentioned in this video and support the channel at NO COST TO YOU. While this channel may earn minimal sums when the viewer uses the links, the viewer is in NO WAY obligated to use these links. Thank you for your support!

Комментарии • 81

  • @nelsonechevarria7009
    @nelsonechevarria7009 2 года назад +5

    We've gotten spoiled now a days.When I used to do plumbing I had a notebook that I carried with me that I wrote up as I went along so that I would always know what I needed when doing the pipe fitting.Now with the copper pipe press fittings it has become so much simpler because there is no theading allowance that needs to be calculated and taken into account.It's a real shame that more people don't appreciate your videos Mr.sessa because you are truly a master plumber,I know that for a fact because I had the honor and the priviledge of working with and learning from licensed plumbers when I was young and wanted to learn.May God always bless you and your family Mr.Sessa and thank you again for another indispensable video.

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  2 года назад

      The "Skill" is gone Nelson, just the world we live in. Regards, Bob.

    • @KawBoyTexas1309
      @KawBoyTexas1309 2 месяца назад

      @@BobsPlumbingVideos we are currently doing this in school right now and it’s tough for me man we’re doing NPT 1/2” pipe and fittings. Our thread engagement is 1/2” our face to center on a 90 is 1 1/4”

    • @KawBoyTexas1309
      @KawBoyTexas1309 2 месяца назад

      I’m having issues figuring out my end to end pipe length calculations

  • @walter.bellini
    @walter.bellini 19 дней назад +1

    Super video, so much to learn, thank you

  • @BobD-iv3xp
    @BobD-iv3xp Месяц назад +1

    Thanks. Since my stroke I forgot how too add it up in my head on the fly and via calculator. More so, I don't have a threader any more and must hit the box store overpriced fittings. Either way its up too me but limited too entrusting and calculating the box store sizes/lengths, etc....
    Anyway.... Good Job, kudos, and thanks again!

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  Месяц назад

      Glad it helped! You're welcome and thanks for the visit! Bob.

  • @jasonmcneil7094
    @jasonmcneil7094 8 месяцев назад +2

    When i do threaded pipe i take my desired over all length take off my fitting throw times two than add my thread engagement. I make sure to write down each step over all fittings then c2c then next c2c >f2f add in my f2f +engagement = cut

  • @Metal_seer
    @Metal_seer 7 месяцев назад +3

    Very practical approach. But, I want to find that paperback, or its modern equivalent, buy, and read it. I'm 78. I was helping my Dad do plumbing on his rental houses about 65 years ago. Now, I do a job once in a blue moon. I can't afford to pay plumbers the cost of a shady lawyer. THANK YOU, Sir!

  • @deadmanswife3625
    @deadmanswife3625 3 года назад +2

    Good morning Bob and have a happy Labor Day weekend. Thank you for the video.🇺🇸🇺🇸🇺🇸🇺🇸🇺🇸❤

  • @mrkrasker9609
    @mrkrasker9609 3 года назад +6

    Thanks for sharing your knowledge with us Bob.

  • @arealmaintenanceandrepairl1103
    @arealmaintenanceandrepairl1103 2 года назад +9

    Take the pipe size multiply by 2 and add one thread size take this number subtract from center to center measurement 3/4x2 =1.5 plus’s 1/2 thread =2 inches now subtract 2 from 18 get 16 boom simple

    • @ssuhuss
      @ssuhuss Год назад

      This is the way.

    • @chrisskidmore7651
      @chrisskidmore7651 9 месяцев назад +1

      Where are you getting the 1/2 thread size if it’s 3/4” pipe a little confused about what you mean for one thread size would really appreciate the help

    • @Karmine_c
      @Karmine_c 6 месяцев назад

      @@chrisskidmore7651 1/2 of thread goes into the fitting.

  • @bobvines00
    @bobvines00 3 года назад +6

    Thanks Bob! This is a very useful video for homeowners (i.e., rank amateurs ;) doing some of their own piping. I personally only do my own "outside" piping and would probably call in a licensed Plumber for inside work because of the risk of major damage if I screwed something up. Outside, any leaks just water the yard!

    • @babugandhibose6663
      @babugandhibose6663 2 года назад +1

      I want need firefighting water pipeline( sprinkler)installation videos sir

  • @scottk0623
    @scottk0623 3 года назад +3

    Nice job explaining it Bob, that’s how I been doing it 40 yrs. We ain’t building a rocket. New construction a lot of the measurements are calculated on the print. I also learned from a book but you know this isn’t real world service. Great video👍👍

  • @eduardorodriguez-ei4mw
    @eduardorodriguez-ei4mw 3 года назад +2

    very good maestro

  • @terrylingo8491
    @terrylingo8491 3 года назад +2

    Really enjoy your videos. Great day to day real world work. Thank you.

  • @michaelmolter8828
    @michaelmolter8828 2 года назад +2

    I just search McMaster-Carr for the fitting. Has the offsets and thread engagement right there. Easy!

  • @seanrichards
    @seanrichards 10 месяцев назад +1

    I'm wanting to replace two small sections of steam pipe. One section is about 3' and the other section approximately 2'. The first is in between a coupling and a 90° and the second between the 90° and a 2" Tee.
    After sizing and whatnot, I'm thinking it through and can't figure out how I'm going to make the connection to the Tee fitting because of "right tighty, lefty loosey"...

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  10 месяцев назад +1

      You'll have to place a union fitting in between the coupling and 90 or the 90 and tee or both.amzn.to/48EG0dB

    • @seanrichards
      @seanrichards 10 месяцев назад

      @BobsPlumbingVideos ...so grateful to you for your timely response. I subscribed to your channel because you seem really cool and I resonate with guy's like you. I ended up figuring it out on my own, about the union,and took most of the day figuring out how to accurately calculate the right threaded length. Do you have a handy fool-proof method for figuring out the calculations without going through all the stress(and numerous trips to home depot to get it re-cut and re-threaded) that my girlfriend and I went through???

  • @babugandhibose6663
    @babugandhibose6663 2 года назад +1

    Thank you sir 🙏

  • @nickcollins7568
    @nickcollins7568 3 года назад +2

    Steel pipe, I would use centre to centre measurements except where I am I would measure in millimetres or metres and pipe threads are all BSP not NPT. Their are tables for fitting allowances but one tends to get to know the more common ones

  • @denvercharlebois699
    @denvercharlebois699 Год назад +1

    How come you do the fitting allowance by the centre to face of the fitting? Why not the centre to the hub ?

  • @anthonykotoff3041
    @anthonykotoff3041 3 года назад +5

    Your videos don’t suck

  • @webcrawler3332
    @webcrawler3332 Год назад +1

    I have a question, if you’re removing a section of pipe or a flex pipe and one of the pipes you don’t want to remove loosens a little. Can you just tighten up the one that moved a little and just tighten it? Or do you have to remove the pipe that moved a little and re-tape and dope it to reinstall!

  • @alexill
    @alexill 3 года назад +1

    Nice video bob. Very informative. Hope you did ok after the storm. I took a trip last night to ave J to get some pizza 😎

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  3 года назад

      I did OK no water, my daughters house not so much. Which Pizza Store? Difara's?

    • @alexill
      @alexill 3 года назад

      @@BobsPlumbingVideos oh yes my friend good guess… domenico “the pizza guy” demarco is a friend of ours 😎

  • @elev8torguy
    @elev8torguy Год назад

    Does this work for electrical rigid pipe?

  • @frankp705
    @frankp705 9 месяцев назад

    Are dresser style/compression fittings acceptable to use to transition between galvanized to pex? Trying to replace a section of 1/2" supply line to a hose bib. Everything is of course badly corroded. Is that recommended if you cant cleanly get a fitting uncoupled?

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  9 месяцев назад

      I would just use a Shark-bite fitting - ruclips.net/video/CuqEibmPVRE/видео.htmlsi=WoS6sIFRmtWhxel9

    • @frankp705
      @frankp705 9 месяцев назад

      Thank you for responding Bob. I can use a shark bite on galvanized pipe without having to cut threads?

  • @edgardooblena6210
    @edgardooblena6210 Год назад +1

    You should use a board to demonstrate your measurements. It woul really help.

  • @briancrandall1601
    @briancrandall1601 3 года назад +2

    I have seen thread protectors used as couplings and you can tighten them until there are no threads left. I am surprised A lot of them dont leak because 2" and smaller are not npt pipe threads.🤔

    • @brooklynaudit
      @brooklynaudit 2 года назад

      That’s cause you using imported pipe

  • @joshcowart2446
    @joshcowart2446 2 года назад +1

    I think the only time I’ve ever used the book on allowances was during my exam. If I remember correctly I think they taught us with iron pipe on a 45 offset the allowance is the pipe size. So on 3/4 you’d take off 1 1/2 total, 3/4 per fitting. Or maybe it’s 3/4 total, I can’t remember but that doesn’t sound like enough. In the field i just put a tape to it and eyeball. It seems like with dwv most of the measurements are pretty round. It’s been a few years since I’ve done a threaded pipe job and I’ve probably done 3 in the last 6 years. We use mega press mostly. But even when I did it I’d just eyeball the tape and it never caused me any issues. The only time I use any of these numbers is on an offset formula. Even then I just measure the allowances. I do find it interesting that the two pipe systems that are going away are the ones that look the best and neatest. I think soldered copper, if done correctly, looks so much nicer than pro press. Funny enough on the video topic copper is easier to measure with solder because there aren’t many take offs. On 90s and tees you jest measure pipe to pipe. With pro press though there’s a small allowance on fittings in order to fit the press head on so you have to account for that. Threaded gas pipe looks so much cleaner than mega press. With mega press you can easily press a pipe in slightly crooked. It won’t leak but it looks terrible.

  • @niteckarobinson7721
    @niteckarobinson7721 3 дня назад +1

    I'm A PF apprentice and I cried about 4x today!!!! I have never felt so useless and dumb. Why can't I get this?

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  День назад

      Example:
      Imagine a fitting with a face-to-center measurement of 2 inches and a thread engagement of 0.75 inches.
      To calculate the fitting allowance, subtract the thread engagement from the face-to-center: 2 inches - 0.75 inches = 1.25 inches.
      This means you would need to cut your pipe to be 1.25 inches long to fit properly into the fitting.

  • @shieldcracker
    @shieldcracker 2 года назад +1

    This topic does not get sufficient recognition in the trades wether it is the books classes or in the field. Great video, I am getting that book! Do you happen to know why steam fittings are so beefier and shorter than regular plumbing & gas fittings. Steam pressure for heating systems is far less than the pressure on water lines no?

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  2 года назад +2

      That's a great question and one I never gave much thought about. I'm going to do a little research and try to answer that for you! Thanks for the question. Bob.

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 3 года назад +2

    When I first started I use to bury the threads.😂
    You forgot to mention the pipe stretcher .🤣
    🍺🍺🍺🥃🍿🥃🏌🏻‍♀️
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses.

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  3 года назад +3

      I once heard a carpenter ask his helper to go and get the sheet rock stretcher out of the van! 😂😂😂

  • @Andre-tc1wj
    @Andre-tc1wj 3 года назад

    New to the channel. Do you have a video on cutting around the shower stems. I saw your video on using a Gerber rebuild kit. Can that replace any 3 handle shower?

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  3 года назад

      Regardless of brand, I use an old screwdriver / small cold chisel to chip away at the tile in order to remove the chrome sleeves going into the wall. I work on Gerber, Price Pfister, Sterling, Central three valve shower body’s in my service area.

  • @servantofthegreatiamloving2113
    @servantofthegreatiamloving2113 5 месяцев назад +2

    In addition carry your black Franklin book in your back pocket

  • @logjamtoo
    @logjamtoo 3 года назад +1

    How about a video showing your truck set up

  • @castillodp73
    @castillodp73 2 года назад

    Hi Bob, I congratulate you for your channel and your videos, very well explained and illustrative. I would like to ask you a question since I have seen in the work of Pipefitters and plumbers most of the time that this type of threaded joints is made by some people empirically and without technical basis.
    Please can you help me solve or know how to solve problems or real situations of take off in threaded joints.
    For this examples:
    1) A piece of NPS ∅2" pipe is being cut to run between two 90° degree threaded fittings. The center-to-center measurement of the fittings is 7'-2¼". What is the cut length of the pipe?
    2) A length of NPS ∅1½ inch pipe is to be cut run between two 90° degree 6.000# threaded fittings. The fittings measure 7 ft 2¼ inches center to center. What is the cut length of the pipe?
    What fittings tables do you use to obtain the dimensions required for the calculations.
    Regards... Thanks

    • @BobsPlumbingVideos
      @BobsPlumbingVideos  2 года назад

      What type of fittings are you using? Black malleable, black steam, brass, galvanized, galvanized drainage? Need that info!

    • @castillodp73
      @castillodp73 2 года назад

      Hi Bob, so sorry for not answering you on time, these fittings are for fixes and spools in AHU's connections for HVAC and Chillers.... #3000

    • @castillodp73
      @castillodp73 2 года назад

      CWR (Chiller Water Return)
      CWS (Chiller Water Supply)
      HWR (Hot Water Return)
      HWS (Hot Water Supply)

    • @castillodp73
      @castillodp73 2 года назад

      Mr. Bob, the book you mention and show in the video is this one:
      Lee Smith
      Mathematics for Plumbers and Pipefitters
      8th Ed.??

    • @brooklynaudit
      @brooklynaudit 2 года назад +1

      @@BobsPlumbingVideos hey bud just hire a real plumber

  • @davidgibson7729
    @davidgibson7729 2 года назад +1

    You could speak up louder but great video keep up the great work!!

  • @JohannnesBrahms
    @JohannnesBrahms 3 года назад +2

    Is there ever a point at which you have wrenched a pipe too much? Great video, btw!!

  • @mikev.1034
    @mikev.1034 3 года назад +2

    👍

  • @588158
    @588158 3 года назад

    I usually measure the distance between the faces of the fittings and then add the thread gain for each fitting to get the pipe length because I can butt my ruler against the face of the fitting to steady the ruler while I take the reading from the other face. Great video Bob! A Pipe threading video would be good follow up video. I remember my father reminding me not to cut the threads too long which he called a steamfitters thread. Are there special dies for electrical conduit or can standard dies be adjusted to reduce the thread taper. I'd love to hear your views about it and how to adjusting pipe threading dies.

    • @joshcowart2446
      @joshcowart2446 2 года назад

      I think it’s completely different dies because EMT has a different OD. The ones I’ve seen were almost exclusively hand crank dies.

    • @588158
      @588158 2 года назад

      @@joshcowart2446Only Ridged conduit is threaded. EMT is not meant to be threaded and is not legal for exterior work.

  • @debbie2027
    @debbie2027 3 года назад

    liked and shared on FB

  • @WApnj
    @WApnj 3 месяца назад

    Making it more complicated than it needs to be. Just measure face to face of the fittings and add one inch.