THIS is why your AC isn’t keeping up 😬❄️

Поделиться
HTML-код
  • Опубликовано: 21 авг 2024

Комментарии • 97

  • @TheHVACDopeShow
    @TheHVACDopeShow  Год назад

    For more videos like this on how you can get the best HVAC for your home and avoid common mistakes, make sure you’re subscribed to the channel here youtube.com/@TheHVACDopeShow?sub_confirmation=1

  • @joestellwagon2122
    @joestellwagon2122 День назад

    I live in Kansas in a 1970s home with original AC equipment and ducts. Thanks for the info. Helpful video.

  • @AF-O6
    @AF-O6 6 дней назад

    This is one of the best overviews on the subject I’ve seen for the potential customer.
    I’ve learned it’s better to have non-adjustable registers, and put dampers for each branch to keep customers from messing with a tuned system.

    • @TheHVACDopeShow
      @TheHVACDopeShow  4 дня назад +1

      Thanks! This is definitely true about the butterfly dampers / airflow balancers, very good for the system and best way to actually balance airflow

  • @slothzilla33-p1x
    @slothzilla33-p1x 4 дня назад

    Definitely was the first summer in a long time in 2024 where I was running my central air at 81 versus 79 or 78. That desert heat wasn't joking this year glad I wasn't trying to fight keeping the temps higher saved on the energy bill not fighting the heat.

    • @TheHVACDopeShow
      @TheHVACDopeShow  4 дня назад

      Yeah I feel you!! Another trick, you can even set it to cool down lower at night once the sun goes down and this can give you a head start for the following day since your home drops to a lower temp over night

  • @Rick-tb4so
    @Rick-tb4so 8 дней назад +1

    You are the only one saying the AC can continually run all day. Mine does in hot weather and I always thought the system was too small.
    Great video.

    • @TheHVACDopeShow
      @TheHVACDopeShow  4 дня назад

      Systems used to be oversized more than they are now, and they thought is for both comfort and efficiency longer runtimes (especially during the hottest part of the day) is perfectly normal and most comfortable. Glad you enjoyed it!

    • @TheHVACDopeShow
      @TheHVACDopeShow  4 дня назад

      The caveat is making sure it’s satisfying design temp which varies by region, but normally is between 72-80F with the hotter temps being design temps in places like Phoenix Arizona where they get extreme highs

  • @DaveIngle1
    @DaveIngle1 Год назад +9

    I learn something every time. As a kid, my parents would have me close different vents and open others in summer and winter. I have always believed and even recommended to friends to do the same. Who knew... a professional I guess!

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      You're not alone! Lol there's a reason we put it in a video :)

  • @patpatboy2
    @patpatboy2 Год назад +8

    I always wondered what was "wrong" with my AC, since we keep it set at 68, but in the middle of summer, it'll frequently creep up to 70-74 if it's REALLY hot outside. I guess the system was probably designed to that 70-74 range you mentioned. I haven't heard of this before from any of the other hundreds of AC videos I've seen, so thank you for spreading the info! :)

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад +2

      For sure! Thanks for watching… When we retrofit a system and do a quote we always ask what temp they like to set things at because I’ve had people say 65 and when we hear that we almost always look at adding a ductless somewhere or VRV unit so that it keeps up!

  • @DavidSmith-vz9uu
    @DavidSmith-vz9uu Месяц назад +1

    Thank you for this information, I was panicking about why my ac unit outside was constantly running the past 3 days almost nonstop since we got 90° to 103° days and staying at 74° to 76° for the inside temperature while the set point is 73°f, so I now know my ac unit is in an efficient mode to save on the life of the AC unit and energy cost.

  • @John-js9je
    @John-js9je 9 дней назад +1

    Higher humidity in the home will be the result of an oversized system, especially in the South. A larger than needed system that is short cycling simply isn’t running for the time needed to remove excess moisture from the home.

  • @alanberry2930
    @alanberry2930 Год назад +6

    From 8:04 to 8:50 is priceless info for those of us living in certain parts of Texas where our units run all the time during the summer months. Kudos for a great video!

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад +1

      Thanks for watching!!

    • @DJ-Art-Morris
      @DJ-Art-Morris Месяц назад +2

      Meanwhile I was over here doing everything i could to figure out how to stop it from running constantly thinking something was wrong 🤦🏻‍♂️

    • @paulsosa1872
      @paulsosa1872 6 дней назад +1

      I live in Houston, TX and my ac doesn't run all the time during the peek summer 72at night and 74 during the day. Now I do have to mention my attic has spray foam insulation. So it's only about 10-15 degrees warmer up there. That means my ac isn't fighting the heat in the attic to cool the house.

  • @TM_Stone
    @TM_Stone Год назад +6

    I had the opposite, an undersized system. I figured when it was in the mid 90s to 100s outside, not getting below 78 indoors was normal. My unit was close to 16 years old so I wanted to replace it before it died on a hot Texas day so I did early this year. Lo and behold, all bids I received told me my 3.5 ton was way too small for my sq ft. of 2699. They did some duct mods and now it cools nicely.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад +1

      This is also true sounds like you had some great contractors who knew what they were doing!

    • @alextran7885
      @alextran7885 2 месяца назад

      😅 who in theirs right mind would installed 3.5 ton for 2700 sf home? 1700 maybe

    • @seabass22
      @seabass22 Месяц назад +1

      I have the same problem. The house was added onto and when the central AC was replaced, it was replaced with the same size and not upsized. Went from like 1700 sq ft to 2300. Still a 3.5 ton unit. The air flow is also messed up. Shut air off going to addition, put a window unit in there. Had to put in dampers to balance the rest. Had a ton of air dumping into one bedroom. Still have a lot of work to do. Poor airflow to two back bedrooms. Duct is coming off the back of the plenum. Someone told me that will cause poor airflow. Need to add a vent going to middle bathroom. Gets hot in there. Lol old houses.

  • @nejdro1
    @nejdro1 Год назад +2

    I remember a few years ago it hit 108 degrees here in Portland, Oregon and my system was not keeping up. i called the A/C people and asked about it. Their answer is simply that they don't design systems in Portland for such abnormal heats. When I later had to replace my 15 year old condenser, I asked them to increase the size from 30K to 36k BTU. Good thing to, as a couple years later we hit a staggering 116 all time record heat and my house stayed reasonably comfortable.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      Yeah that sounds right the design temps vary by region but if your ductwork could handle the increase in sizing (which it sounds like it can because it’s not icing) then it sounds like it was a good move 😁

  • @nejdro1
    @nejdro1 Год назад +3

    There is another consideration in system sizing in very humid areas: If a system is sized too big, it will bring down the temperature before it has reduced the humidity in the house, resulting in the homeowners feeling cool and clammy.

  • @USCG.Brennan
    @USCG.Brennan Месяц назад +2

    I have a geothermal system and it works fantastic for heating and cooling.

    • @Goodfella0982
      @Goodfella0982 12 дней назад

      lol

    • @USCG.Brennan
      @USCG.Brennan 12 дней назад

      @@Goodfella0982 That's somehow funny, or do you not know what a geothermal system is? Google is your friend.....get educated.

  • @corbanharvey
    @corbanharvey Месяц назад +1

    Really helpful! I just turned my fan onto On instead of AUTO, hoping that makes a difference. One end of my home is warmer than the other. I also have my thermostat in a hallway, I’ll need to move it to the living room. Thanks again 😊

    • @TheHVACDopeShow
      @TheHVACDopeShow  Месяц назад

      Right on glad it helps! Hopefully you notice a difference it normally does on the hottest days especially

    • @USCG.Brennan
      @USCG.Brennan Месяц назад

      Did I miss something? My fan is currently set at "auto" so should it set it on for continually on?

    • @serlalonde8420
      @serlalonde8420 29 дней назад

      @@USCG.Brennan It depends on your geographic location. Generally if you are in a high humidity area like southern U.S than that is a very bad idea. if your air handler/furnace blower is running continuously independent of A/C setpoint you will be drawing in hot, humid air through doors ,windows etc. without it being conditioned. As in you are bringing in unfavorable air when your A/C condenser is not operating so introducing higher load than designed for and will cause many issues.
      TLDR: Leave fan on auto

    • @USCG.Brennan
      @USCG.Brennan 29 дней назад

      @@serlalonde8420 I'm in Western Oregon (near Salem) and our humidity is far less than down South (where I was stationed).
      I've been leaving it set on Auto and we're OK with that. Thanks for the info though.

    • @lordelliott42
      @lordelliott42 4 дня назад

      @@serlalonde8420
      Are you saying that the AC is blowing conditioned air outside? Because that’s the only way I can see it creating a vacuum that sucks air through cracks around windows and doors.

  • @user_jonathansaine
    @user_jonathansaine 24 дня назад +2

    thanks! it ended up being i tried using too high a quality of a filter than my AC could pull though. I switched it back down to a lower quality and the thermostat started to drop almost right away

    • @Goodfella0982
      @Goodfella0982 12 дней назад

      Correct. Some filters like 3m make very thick filters and can cause a restriction. I always recommend 11 or 13 Merv filters, unless you have a very high efficiency unit where it was made to take the media filters that are about 6 inches thick

  • @boosted300
    @boosted300 Месяц назад +3

    I wish you had a branch in Miami...no one here wants to take the time to conduct such a comprehensive analysis, and/or they simply aren't sufficiently knowledgeable to do it. I had a "reputable" Trane authorized company come out to give me an estimate on installing a new, additional, split system to my house as the two existing 5 ton systems are unable to keep the temperature from rising during severe temp days in the summer... and they told me that I had to hire a GC to do a load calculation to determine the size of the new system...I mean, shouldn't a good AC company be able to do that? Certainly sounds like your company can...

  • @kabloosh699
    @kabloosh699 Год назад +3

    Interesting. My problem with my A/C is the second floor works great, but the first floor doesn't feel like it is getting much air. The ducts are open on the first floor yet it doesn't feel like any air is coming through them while upstairs it most certainly is.
    The air isn't naturally trickling down either so while I have the upstairs set to 70, the first floor is 74-75, and the basement is even warmer at 75-77.
    I don't have central heating but heat rises just fine in the house. I also have electric baseboards to compensate so this isn't an issue I am seeing.
    I feel like something is jammed in the ducts or something.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      This is very strange I’ve never heard of a basement being warmer than the rest of the house when the AC is running. I would look at ducting. Sounds like an issue with airflow balancing or maybe runs being disconnected, I’ve never ran into this lol for what that’s worth… sounds like ducts aren’t connected or dampers are shut or something is off with the design

    • @KMCA779
      @KMCA779 14 дней назад

      I've never heard of a basement being warmer, I'm curious on the how myself.

  • @bikeny
    @bikeny Год назад +1

    So, if your system is running all day and keeping things set to where it's designed, then I take it to mean that just like a car with cruise control engaged, it runs smoothly. If it's running like it's driving in New York City, well, stop & go driving is no fun. Thanks for a good video. I'm gonna share it with a few folks so they check their systems against the points you mentioned.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      Awesome sounds good and glad you enjoyed it and found it helpful!

  • @NotSexualAtAll
    @NotSexualAtAll Год назад +1

    If I close a vent, I also shut the room door off from the rest of the house. That does help significantly.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      Right on if it’s not icing then it’s probably fine… It still restricts total airflow so if you have too many vents shut to the point it ices us and doesn’t keep up it will actually be counterproductive. We advise people to keep as many vents open as possible. In systems with undersized ductwork even 1 or 2 closed vents out of 10 or 12 can make a difference to cause things to ice.

  • @thenexthobby
    @thenexthobby Месяц назад

    Our downstairs A/C seems to be a decent size. No it does not run 24/7 but nor does it short-cycle.
    We have a separate attic system for the 2nd floor. It’s a smaller system. It’ll maintain our set point of 75 until the outside air rises to about 85 and then by 90 it can longer keep up. Putting the air handler and duct work in the attic does it no favors. 83 yr old house and the sun bakes the roof.
    We have R38 in the attic - not too bad for TN - none of which really matters in summertime.
    I’m also of the opinion that the return isn’t sufficient and am thinking of perhaps adding an additional return to it if I can.

    • @Goodfella0982
      @Goodfella0982 12 дней назад

      Sucks with air handlers in the attic! Companies even charge more $ when they know your air handler is up there!

  • @michaelkearney7923
    @michaelkearney7923 6 месяцев назад +1

    It just kills me that I pay natural gas surge prices in Colorado when Texas is falling apart because the utilities don’t cold proof their gas pipelines and generators. I’m with you on heat pumps to free me from Texas’ energy failures.

    • @TheHVACDopeShow
      @TheHVACDopeShow  5 месяцев назад +1

      Yeah Texas also has deregulated energy which I think has made things cheaper but also kind of the Wild West in certain respects

    • @Goodfella0982
      @Goodfella0982 12 дней назад

      They're trying to convert everyone to heat pumps! Some states just don't need them like Florida for example

  • @user-zr1dq9cv4s
    @user-zr1dq9cv4s 6 месяцев назад +1

    Well explained, thanks

    • @TheHVACDopeShow
      @TheHVACDopeShow  6 месяцев назад

      Right on my pleasure! Glad you enjoyed the explanation!

  • @KPHVAC
    @KPHVAC Год назад +1

    If you only have 1 return air duct in a house it's a Red Flag! Make sure you have a HVAC tech check your static pressure! If the total static is over 0.50 you need to fix the size of your ductwork! In my area over half the homes only have a single undersized return air duct. This is often giving you half the airflow that your system is designed to move.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      Agreed! The builders don’t have to service the equipment otherwise they’d add more return air

  • @MrOscar5690
    @MrOscar5690 11 дней назад

    Amazing, informative video..
    I’m still not sure where our system falls.
    Thanking you in advance for reading and hopefully you can provide some suggestions.
    Just bought this house. It’s our second week. Just recently found the filter was inside what we learned to be a “furnace”? Incredibly intimidating, we managed to find the filter door that was painted shut. We dusted it and stuck it back in while the replacements arrived.
    After cooling house cooled much better.
    But next day, it wouldn’t cool anymore. After checking we found some splashing near a plastic pipe, initial research suggests pipe clogged but there’s water flowing into some water pump/box thing
    How do I address this?
    Secondly we found ice, initial googling suggested run heater for a bit. How can we check if the freezing is caused by dirty filter and not by other factors?
    Thank you again

    • @TheHVACDopeShow
      @TheHVACDopeShow  11 дней назад +1

      Remove the filter that will probably fix it and open all vents in the house just dropped a video this morning on the topic 😁

  • @fluoriteheals
    @fluoriteheals 9 дней назад

    We leave ours at 77-79 normally. at the lowest its on 75 for maybe 10 minutes. It's so hot here it's pointless to keep it below 77 for a long period of time. It just runs constantly.

    • @TheHVACDopeShow
      @TheHVACDopeShow  4 дня назад

      Yeah you’re not alone in the summer things get hot and run constantly so it happens!

  • @KpxUrz5745
    @KpxUrz5745 Месяц назад

    I knew when they were installing my new central air system in my 101 yr old house that it would never actually be comfortable inside. Mainly because they had not even invented insulation when the house was built!!! (Nor was there any indoor plumbing!) This is in a moderate southeastern normal residential neighborhood. We actually set the thermostat on 82 downstairs in hot weather, and a miserable 85 upstairs, because otherwise they would both run day and night and never stop or catch up. It would be impossible to upgrade the entire house to install insulation, because it would be far more cost effective to just bulldoze the house and rebuild... believe it or not. So, other than simple things like checking filters and cleaning condensers, there are no real solutions here. Oh, incidentally, during winter we set the thermostat on a cool 61 for "heat"! Can't raise that to a comfort level for the same reason. One more thing: if I were to blow in insulation, would have to ensure this is not creating a fire hazard around the 100 yr old knob-and-tube wiring! Main lesson: Think twice before buying an OLD house!!!

    • @TheHVACDopeShow
      @TheHVACDopeShow  Месяц назад

      I would verify its sized properly for the load and ductwork. A simple “cheap” insulation is blow in… you can get the machine rental at Home Depot for free if you buy enough insulation, it’s like maybe $500 to insulate a 1200’ attic space and that will usually make a huge difference if you have no insulation whatsoever

    • @KpxUrz5745
      @KpxUrz5745 Месяц назад

      @@TheHVACDopeShow Thank you for the reply. I have attic landing insulation, that's not really the problem. It is a large old house with plaster on lath walls downstairs, and wood drafty beadboard walls upstairs, no insulation. By creating countless DOZENS of holes in these walls to blow in insulation, it could help some, but would then create a virtual nightmare to repair all those plaster and beadboard holes throughout 11 large rooms. Plus, the old style construction used angled members some places behind the walls, which would prevent blown in insulation from filling the voids. The house would be absurdly impossible with holes every 16 inches in 11 large rooms, just about impossible to properly repair. Not easy like drywall is.

  • @bikeny
    @bikeny Год назад

    Typos are fun. @6:34 "Duck" Work Size.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      Lol thanks I catch them but honestly don’t have the energy to send it back to the editor so as long as it’s nothing crazy I let it slide. You’re paying attention, good eye!!

  • @jesseyriley6931
    @jesseyriley6931 Год назад +1

    Any recommendations on a replacement system in Las Vegas? Currently have two 25 year old Carrier furnaces a 17 year old york single stage condenser and an 11 year old goodman condenser single stage. When the time comes to replace does it make sense to replace with single stage? I’ve seen your videos about the Daikin Fit and also seen video about Bosch ids 2.0. Not sure how heat pumps would work in the desert tho. Thanks for the advice.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      They work great but I would check with a local contractor on the Daikin fit and in Vegas get a higher efficient inverter system you’ll be much happier you did… your AC runs constantly there the savings will definitely pay off over time. I’ve heard the Daikin fits do well but in high ambient above 110/115 there can be issues with humidity during monsoon season (in phoenix) above 3.5 ton systems only. So just check with a local contractor that sells Daikin because they’ll have the inside scoop on local systems, but an inverter system is definitely worth it in vegas and will keep up fine in the winter too.

  • @Debate_everything
    @Debate_everything Год назад

    I keep thinking there’s something wrong with my system, and I think that there must be because I have my setpoint at 77 and by the 3 o’clock hour the machine is running constantly, and the temperature will be upwards of 81. The machine itself sits in direct sunlight for 90% of the day and the outside temperature in the summer months gets to 105+. It seems to me that the machine is not able to keep up, but I don’t understand what the issue is.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      Has it ever kept up? I would check the basics like air filter / open all the vents etc… it could be refrigerant charge but I always check airflow and basics first. Especially if it was working at one point and just recently stopped… if it’s never worked properly from day 1 it could be a sizing issue / design issue.

  • @BBrown-gs8sv
    @BBrown-gs8sv 13 дней назад

    If the condenser is dirty u will never have a iced up evap coil I'm sorry to inform but that is not possible dirty condenser coil raises the refrigerate pressure an temp

    • @Hi-TechHillbilly
      @Hi-TechHillbilly 13 дней назад

      Come to my house I'll show you one.

    • @Goodfella0982
      @Goodfella0982 12 дней назад

      Honestly, I've never seen a dirty condenser ice up an evap coil. It will definitely cause high head pressure, and your capacitor might have to be replaced and down the road eventually your compressor will fail

    • @TheHVACDopeShow
      @TheHVACDopeShow  9 дней назад

      I’ve seen it ice up from this, throw a trash bag around your condenser and watch your suction line temp drop

  • @victorstandiford9724
    @victorstandiford9724 8 дней назад

    If an AC unit is running constantly, doesn't that mean it never reaches the set point and therefore is undersized?

    • @TheHVACDopeShow
      @TheHVACDopeShow  8 дней назад

      It will run constantly to reach setpoint in the summer… if it’s 5 degrees warmer than design temp (varies by region, 72-78F are typical design temps depending on your region for cooling) then it could be undersized if the system is working properly and there’s not another hidden issue… I’ve seen everything from returns disconnected in attics sucking in hot air to systems that just won’t keep up because they were low on charge, but if everything is dialed in then it can often times come down to the load being greater than the home can handle.

    • @victorstandiford9724
      @victorstandiford9724 7 дней назад

      @@TheHVACDopeShow Unless I am missing something ( quite possible) the unit should cycle off when the set point is reached. Short cycling means that it is reached too quickly. and things ice up. I have read that an AC unit cycling off 2 to 3 times an hour is optimal.

  • @Smudg
    @Smudg 12 дней назад

    Hi, Great video and I watched it more than once and I have a question; After a power failure during a thunderstor, the AC kicked back on and all was good untill we noticed that it is colder in the house than usual while the thermostat was set to 74 degrees, i eventually cranked it up to 77 wich is still cold but 78 is not comfortable. I tried resetting the thermostat to factory settings and still doign the same thing. I downloaded two apps on my phone to read room tempreture and they both read lower by 3 to 4 degrees. My thermostat is Honeywell pro. Hopefully i can get some help,

    • @Goodfella0982
      @Goodfella0982 12 дней назад

      Maybe the t-stat temp. sensor is bad. If you have a Honeywell, you could try switching to a Honeywell T4 thermostat, they are very reliable and not crazy expensive, unless you have a 2-stage unit then I would try a Honeywell T6

    • @Smudg
      @Smudg 12 дней назад

      @@Goodfella0982 Thank you , I looked at the T4 pro online and look like the same backplate connections, so I can just plug it in and program it without wiring or rewiring?

    • @Smudg
      @Smudg 11 дней назад

      I switched the T6 witha T4 and set it up correctly and I am still experiencing the same thing. Is ther anything else that could be bad, up in the attic or in the outside unit?

    • @TheHVACDopeShow
      @TheHVACDopeShow  9 дней назад

      Have you adjusted the calibration in the stat? If the temp is off you can just adjust the calibration so the temp on the screen reads the same as the temps on the phone

  • @justingwin2966
    @justingwin2966 18 дней назад

    I live in south texas and just moved into a house. 1400 sq ft and the outside is a 4 ton and the inside is a 5 ton. I have 8 vents in the house. I have it set at 80 and in the heat of the day it goes up to 83. Is that normal? It takes about 4 hours for it to start dropping down to like 75. Just wondering if this is normal or not?

    • @TheHVACDopeShow
      @TheHVACDopeShow  17 дней назад

      Depends if it’s icing, does it continue blowing air during the heat of the day or does the airflow stop and it develop ice on the line sets outside? It should be sized to keep up, it could be low on charge but it does sound slightly oversized for the ductwork. You could try adding a few duct runs but I would get a contractor out there to verify because at a glance it sounds oversized and like a 3 ton (outdoor unit) would keep up better. Indoor unit just has to be at least the same size or bigger and the fan speeds can be turned up and down

  • @micaht52
    @micaht52 21 день назад

    I just had a new unit put in(3ton) in a 1200 sqft house same as the old one but it blows way harder. I have so much positive pressure its blowing the pet door going into the garage open Now. I added weight to the door, made sure all vents were open, and even remove the filter to make sure it wasn't too restricted. It still has too much pressure. Any ideas?

    • @TheHVACDopeShow
      @TheHVACDopeShow  21 день назад

      Turn down the blower speed, it’s probably a bigger air handler and you can adjust the speed taps… installer should be able do this

    • @micaht52
      @micaht52 20 дней назад

      ​@@TheHVACDopeShow thanks!

  • @jeremyh172
    @jeremyh172 Год назад

    How bad is it if I don’t have a cold air return? My house does not have one and my ac can’t ever cool my house down.

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад

      What do you mean doesn’t have a return? That’s not possible the system will just ice and not run and not be able to circulate air. You definitely need enough return air otherwise it won’t circulate air without a return… did a fix and flipper cover them up or something ?

  • @manuelsalgado8510
    @manuelsalgado8510 Месяц назад

    My system is not cooling as it did before, any ideas?

    • @TheHVACDopeShow
      @TheHVACDopeShow  Месяц назад

      Filter, airflow, dirty condenser or coil, too many vents closed…all the basics first. After that I’d check charge refrigerant could be low

  • @Flipcrypto
    @Flipcrypto Год назад

    *The Dope HVAC Show? 😂

    • @Flipcrypto
      @Flipcrypto Год назад

      Current Name: “How to pump the most dope through your AC!”

    • @TheHVACDopeShow
      @TheHVACDopeShow  Год назад +1

      No, but thanks though 😂 I do agree dope hvac show makes more sense tho but idk why we just stuck with the other order lol

  • @blessing1564
    @blessing1564 9 месяцев назад

    Why is it that my ac after 10:30 turns off delay to turn on til 2:30 am

    • @TheHVACDopeShow
      @TheHVACDopeShow  9 месяцев назад

      Probably just settings in the programming

  • @xtremeownagedotcom
    @xtremeownagedotcom Год назад +2

    shit, my minisplit can cool it down to 58 degrees while I sleep. I love this thing.