Earth electrode testing the proper way

Поделиться
HTML-код
  • Опубликовано: 25 ноя 2024

Комментарии • 49

  • @Jake_Baker_Electrician1997
    @Jake_Baker_Electrician1997 Год назад +3

    Not a test I have had to undertake often, so this video will be a massive help to refresh the memory in future!
    You’re probably the best RUclips Spark for informative content that looks awesome 👌 watched all your content and I’ve adopted a lot of the things you do into my own skill set which has helped me massively as an apprentice!

  • @walseee
    @walseee Год назад +7

    Where you been, we’ve missed you 😢

  • @bramcoteelectrical1088
    @bramcoteelectrical1088 Год назад +1

    good to see as not many have done the 3 lead test or understand how to carry out this testing good video thanks

  • @TheHomeent
    @TheHomeent Год назад +1

    Once again you nailed it.
    Always great videos.
    Full of information and the job done properly, no shortcuts.

  • @DarkShadowedOne
    @DarkShadowedOne Год назад

    Only just had to use this sort of tester at work this week for doing lightning protection testing. Lucky you have a nice open area to drive your test stakes in for your video

  • @fredflintstone1
    @fredflintstone1 Год назад

    years ago I used a wheatstone bridge meter for testing earth rods in hospitals

  • @patterdalezipsuzilil
    @patterdalezipsuzilil Месяц назад

    I used to fit mats 4ft square copper dig a big hole all rods and plates only work if soil is damp with plates we put sink waste pipes into ground for watering in dry weather

  • @rattlehead85
    @rattlehead85 Год назад

    Fantastic video mate. Good reference material to go back on as this test is not one of the common ones and not many sparks could tell you how to do it. Calculations towards the end got a bit complex with the percentage deviation but how you explained it was great. Well done fella. Enjoy your content. 👍🏻👍🏻👍🏻

  • @johnward5006
    @johnward5006 Год назад +1

    Top man! You nailed it and that's a plumber commenting!

  • @Engineer-Samibress
    @Engineer-Samibress Год назад

    Thanks for your time

  • @fje1948
    @fje1948 Год назад

    Excellent video - you do thing’s properly! Many thanks Mike.

  • @paulstimpson8977
    @paulstimpson8977 6 месяцев назад +1

    I went with a cheaper tester as testing can be done with as you say by 3 methods, my luck get called to a TT install with a fault no power (Fuse pulled) and what looks like a disconnected Earth Rod! Didn't do the job in the end because no one knew who pulled the fuse or why and other issues! But I would have been in a pickle not being able to prove the TT earth was sound prior to the Supplier (DNO had no contact and stated that without knowing why the fuse was pulled they would not reinstate) coming out and who knows when they would turn up! Would probably need to be there when they came.

  • @corymac
    @corymac Год назад

    Great job! 👍🏼

  • @e5Group
    @e5Group Год назад

    coming along nicely

  • @avfczoff
    @avfczoff Месяц назад

    Really helpful video & well explained 👍🏻

  • @lowrybrock8272
    @lowrybrock8272 Год назад

    That’s really interesting stuff. And go ahead and admit it, those were your toys weren’t they? Good to see you back! Be safe out there!

  • @sergiofernandez3725
    @sergiofernandez3725 Год назад

    Great explanation Mike

  • @tincanpete
    @tincanpete Год назад

    interesting and helpful video... thanks!!

  • @alantowler9430
    @alantowler9430 Год назад

    excellent video.

  • @chas3997
    @chas3997 2 месяца назад

    look st the reason behind the test its to find if your intentional earthing rod position is placed at higher resitance postion than other possible ground at a much lower resistance.
    In real life we place them where they wont be disturbed and have a loop value below a 100 ohms 😀. ( the condu disk project you did i would see a calculated average being of more value than this over kill method for a single ground stake 🧐)

    • @residualelectrical
      @residualelectrical  2 месяца назад

      Mate it’s literally the preferred test method in guidance note for testing earth electrode systems, it’s also great for determining rod location, same principals.
      The purpose of the video was to educate others on how to conduct the test, if anything the simpler the installation, the easier to get the knowledge across.

    • @chas3997
      @chas3997 2 месяца назад

      @@residualelectrical Yes all good but i think the purpose of this test is to find the best location
      for the ground rod as far as impedence but there other considerations as well such as location it wont be distubred or provide a hazzard.

    • @chas3997
      @chas3997 2 месяца назад

      personally aslongs its below 100 ohms and not distubed im happy with that !

  • @flint1982769
    @flint1982769 Год назад

    Great video!!

  • @maximuspareo
    @maximuspareo Год назад +2

    It is ok 16 ohm ???
    In my country we need 4 ohm for normal and 1 ohm for + lighting protection .

    • @adriatikkrasniqi1453
      @adriatikkrasniqi1453 Год назад

      How did you do calculations is 2.2 percentage. To ne work out 3.8 percentage..,

    • @abdulseaforth6930
      @abdulseaforth6930 4 месяца назад

      @@adriatikkrasniqi145316.2/16.56≈0.98 ie 2% difference

  • @Riley_Jarvis_the_sparky
    @Riley_Jarvis_the_sparky Год назад +1

    Lovely video bud keep it up 👍

  • @iosebbegiashvili8145
    @iosebbegiashvili8145 9 месяцев назад

    previously with efli test you have almost similar readings ,i wonder ,is it worthy to do potential fall test as well?

  • @chrismason3341
    @chrismason3341 7 месяцев назад

    Dno or supplier still not been out to reseal?

  • @SpikesMavic
    @SpikesMavic 6 месяцев назад

    But if the test Spikes are into dry ground, what will that measure ?

  • @vioreltanasa988
    @vioreltanasa988 10 месяцев назад

    What are you doing when you measure to a industrial place and you cannot disconnect earth because are a engine in process

    • @martijn7924
      @martijn7924 6 месяцев назад

      Look up stakeless and selective earth testing. If money is not an issue, see earth clamp meters as well.

  • @NabeelAhmad-gp5ps
    @NabeelAhmad-gp5ps 5 месяцев назад

    I haven't five years experience in this field...please guide me and help me i want work with you

  • @electricalservicesmaroc
    @electricalservicesmaroc Год назад

    Hello man ❤❤❤🎉🎉🎉

  • @vioreltanasa988
    @vioreltanasa988 10 месяцев назад

    Rezistence should be under 4 ohms for civil and industrial ,and under 2 ohms for farming 😢

  • @vioreltanasa988
    @vioreltanasa988 10 месяцев назад

    You have only 1 electrode must be 3 in star connected

  • @adriatikkrasniqi1453
    @adriatikkrasniqi1453 Год назад

    I done the calculations 3.8 percentage not 2.2 percentage…

    • @fje1948
      @fje1948 Год назад +1

      @adriatikkrasniqi1453
      Hi. Can you please provide an analysis of your calculations - Thank you. I make it: max deviation from average 16.56 - 16.20 = 0.36 then (100/16.56) x 0.36 = 2.17% which is close to Mike’s result!

    • @adriatikkrasniqi1453
      @adriatikkrasniqi1453 Год назад

      @@fje1948 you have to do the highest minus average taken from 3 reading then divide by the highest + - 5% but not more then that…

    • @fje1948
      @fje1948 Год назад

      ⁠@@adriatikkrasniqi1453
      Thank you for your swift reply.
      Using Mikes readings:
      Highest 16.84
      - Average 16.56
      ----------
      0.28
      Further using your wording:
      ‘Then divide by the highest’ 0.28/16.84=0.01662708 ???????????
      Your detailed calculations using Mikes readings would be appreciated - Many Thanks.

    • @adriatikkrasniqi1453
      @adriatikkrasniqi1453 Год назад

      @@fje1948 than times by 100 %

    • @adriatikkrasniqi1453
      @adriatikkrasniqi1453 Год назад

      @@fje1948 I the end of the day is good to contribute with this calculation for us as learners maybe I am wrong Mike calculation I could be right I don’t but he to explain the calculation.

  • @vioreltanasa988
    @vioreltanasa988 10 месяцев назад

    I am not satisfied with this

  • @vioreltanasa988
    @vioreltanasa988 10 месяцев назад

    Electrods sh