HOW TO PREFORM EARTH RESISTANCE TEST

Поделиться
HTML-код
  • Опубликовано: 27 сен 2024
  • This tutorial show how to carry out earth resistance test for commercial and resident building . Proper setting is importance for getting the better and accurate test result .

Комментарии • 238

  • @fje1948
    @fje1948 Год назад +2

    The video I was looking for! Excellent explanation of the test. Thank you so much!
    Ps: The background music is pleasant and appropriate!

  • @kyoritsu7886
    @kyoritsu7886 23 дня назад

    Hello, this is Kyoritsu Japan.
    It is so honor that you used our product.
    We highly trust we can learn more from your excellence in feedback on electrical equipment.
    If you don't mind, we can contact via email.

    • @haseebali499
      @haseebali499 7 дней назад

      Great You from Kyoritsu Company Right

  • @manjunathamanju6204
    @manjunathamanju6204 3 года назад +2

    Thank you Sir this video very useful for all Electrical engineers

  • @muhdsolihin2641
    @muhdsolihin2641 Год назад +12

    should be disconnecting earth cable from house to ground chamber first. so you will get the purest ground resistance.

    • @pankajmishra43
      @pankajmishra43 Год назад

      Hiiii...
      You mean, first disconnect the earth cable from earth pit??
      OR
      Can we shutdown the entire system before measuring earth resistance??
      Pls guide

    • @Sim_Tiby
      @Sim_Tiby Год назад

      Disconnect the earth cable.

    • @DiReal_Donclassy
      @DiReal_Donclassy Год назад

      Of course he must have done that before starting the test otherwise the resistances of home equipment will distort the result

  • @MrSyahryzal
    @MrSyahryzal 3 года назад

    Mudah untuk difahami... Lama mencari video earthing test untuk menambah ilmu. Terima kasih boss

  • @o-techtips3871
    @o-techtips3871 3 года назад +1

    Thank you very much for your sharing very informative tips☺️

  • @muhdyunus3894
    @muhdyunus3894 3 года назад

    Video paling sng difahami...tq sgt2

  • @castertroycabillar2863
    @castertroycabillar2863 3 года назад

    Thanks for this very informative vedio. More power.

  • @sanjeevraghav3700
    @sanjeevraghav3700 2 года назад +2

    Very nice vedio 👌👌kudos to your effort 🙏🙏👌

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @fazrulchanneltv9157
    @fazrulchanneltv9157 2 года назад

    Tq Sir. Clear and easy to undrstand. This place is like "Bukit Bendera" 😅

  • @electroboy3607
    @electroboy3607 Год назад +1

    Good job..🎉 im practical test

  • @kirotomato7316
    @kirotomato7316 3 года назад

    easy to understand,thank you sir for wharing the information for us

  • @electroboy3607
    @electroboy3607 2 месяца назад

    Good interesting vedio😊😊😊

  • @kanthasamymuthusamy739
    @kanthasamymuthusamy739 2 года назад

    Simple explainations.Easy to underdstand

    • @30mAkills
      @30mAkills Год назад +1

      Shifting potential spike towards right and left is wrong.

  • @sanjeevraghav3700
    @sanjeevraghav3700 Год назад

    Appreciate 👌👌you have done share gr8 experience with kyoritsu instrument 💐
    This is sanjeev raghav from kyoritsu

    • @rictorrictor888
      @rictorrictor888  Год назад

      Thank too .kyoritsu always the great equipment ..

    • @30mAkills
      @30mAkills Год назад

      This method is not FOP.

  • @ofwj-ddah
    @ofwj-ddah Год назад

    Thanls for sharingbthis video. It helps me a lots

  • @MrOner07
    @MrOner07 2 года назад

    very easy to follow... you earned a subscriber!❤️😊

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @michaelisongekwere1402
    @michaelisongekwere1402 Месяц назад

    It was beneficial

  • @aubreynorkee6854
    @aubreynorkee6854 29 дней назад +1

    Thanks again

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 29 дней назад

    Please could you explain the operation of the meter and the readings.

  • @marchomeautorepairs
    @marchomeautorepairs 2 года назад

    Keep up the good work

  • @haseebali499
    @haseebali499 7 дней назад

    One more thing what's the distance between two consecutive Earth Pit
    what's the exact standard if you can please explain this the the minimum distance between two consecutive Earth pits

  • @neilblenkinsop2613
    @neilblenkinsop2613 Год назад +2

    To individually test the earth rod disconnect tape from earth rod

  • @lonedragon4410
    @lonedragon4410 2 года назад +5

    Below 5ohm is acceptable right?

  • @CrisBoy410
    @CrisBoy410 Год назад

    video excelente parabens , abraços do Brasil .

  • @ahmedbelazi2318
    @ahmedbelazi2318 Год назад

    Thank you for the effort made in the video.... I have a question... Is it true that the yellow wire is supposed to be an extension of the red wire, meaning on one line to give the reading... Why change in yellow only and should it be changed in red? ??

  • @redbirdgaming7905
    @redbirdgaming7905 3 года назад

    Thank you very much sir Many Thanks

  • @william5624
    @william5624 2 года назад

    Very good👍🏻

  • @bundaajhalah
    @bundaajhalah 4 года назад +1

    Hadir nyimak 👍

  • @gabus1956
    @gabus1956 2 года назад

    Thank
    from Hungary

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @nathan37141
    @nathan37141 Год назад

    Thank you Engineer

  • @francisrayang805
    @francisrayang805 3 года назад +2

    Hi sir. You did a very informative video thanks. I've a question for you.In the video you did the test on a big compound. I'm in a terrace house and the compound is very limited. I can't pull the yellow and red cable that long..only 3-4 meters to the nearest soil. Will it affect the reading? Please advice thks.

    • @rictorrictor888
      @rictorrictor888  3 года назад

      In that situation ..You can try nearest area to ground the spike ..

    • @rictorrictor888
      @rictorrictor888  2 года назад

      in that situation ..yes..

    • @30mAkills
      @30mAkills Год назад

      You have to maintain distance. Please read my other comments. Get permission from neighbours.

  • @matsetizar65
    @matsetizar65 4 месяца назад

    when lightning strikes the earth doesn't the surge enter the house via the earth wiring? If so isn't it dangerous, probably better not to have any earthing system at all?

  • @angelosrcayabyab6952
    @angelosrcayabyab6952 2 года назад

    thanks for sharing

  • @iranweranga225
    @iranweranga225 Год назад

    Is there a specific number of times that earth resistance testing should be done for a specific area? (like number of times per meter squard)

  • @niezam1729
    @niezam1729 3 года назад

    Jika persekitaran rumah tamn agak sukar nk ambil bacaan,sb permukaan tanah @ berturap simen Dan jalan tar.
    1- minutes 6.15 mase kita clamp wayar di electrod bumi.yg seeloknya copper tape @ cable incoming perlu ditanggalkan @ tidak semasa nak ambil bacaan.klu sye lihat Tuan x buka ..

    • @nasrulhelmeihalimppksistem7432
      @nasrulhelmeihalimppksistem7432 3 года назад +1

      kalau kawasan tar @ bersimen, boleh guna metal screen @ earthing mat. letak pada jarak yg ditetapkan & siram dgn air jd blh buat measurement

  • @قصيعليعبدالهادي
    @قصيعليعبدالهادي 2 года назад

    Thank you, sir

  • @pankajraina4832
    @pankajraina4832 Год назад

    Good sir 👍

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @fauzibafana9089
    @fauzibafana9089 2 года назад +1

    Can i know whether before the individual earth rod being tested you have to remove the connection of the earth rod from the rest.

    • @gniraj8501
      @gniraj8501 2 года назад

      I am also have same question.

    • @30mAkills
      @30mAkills Год назад

      Yes it should be disconnected from service. If the voltage is more than 10 it will destroy the meter and also give false reading. Please read the user manual reg the max voltage limit that the meter will work safely in energised service without disconnection.

  • @igorsmirnoff8578
    @igorsmirnoff8578 Год назад

    Будьте любезны,выложите такое же видео с прибором KEW 4106,спасибо!!!

  • @jillferrer6135
    @jillferrer6135 2 года назад

    thank you sir..

  • @wazzer5293
    @wazzer5293 10 месяцев назад +1

    Sir, how 1). If earth got voltage, what is the next action.. 2). When to use the setting mode 200 & 2000? Apprecite ur answer

  • @sahayaxaviersahayaxavier3217
    @sahayaxaviersahayaxavier3217 3 года назад

    Salute sir

  • @solomonnyaga7018
    @solomonnyaga7018 Год назад

    Does it mean now the earth resistance is perfect?

  • @yusufsupyan9940
    @yusufsupyan9940 4 года назад

    Luar biasa kawan Videonya.
    Sudah saya kirim Bungkusan komplit dan,paten, durasipun Aman. Sesuai undangan.
    Ditunggu Amanahnya ya..

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 Месяц назад

    whats the meaning of 20ohms, 200ohms, and 2000ohms ?

  • @dakwahislamcn6390
    @dakwahislamcn6390 4 года назад

    Lanjutkan

  • @MdSultan-u4e5t
    @MdSultan-u4e5t Месяц назад

    good

  • @muhammadaresyamilbinazman7935
    @muhammadaresyamilbinazman7935 2 года назад +1

    Tumpang tanya, kan ada 20ohm, 200ohm, dan 2000ohm. Yang tu nak laraskan berdasarkan faktor apa ye?

  • @FabioHM71
    @FabioHM71 3 года назад +3

    the operator wears the helmet because there are suspended loads?

    • @rictorrictor888
      @rictorrictor888  3 года назад +2

      He worries falling mango fruit..hahaha

    • @FabioHM71
      @FabioHM71 3 года назад

      @@rictorrictor888 hahahaha ;-)

    • @fidelcatsro6948
      @fidelcatsro6948 Год назад

      there are flying cats around in the neighborhood

  • @ericmunkanta2964
    @ericmunkanta2964 5 месяцев назад

    Why is the leads in the same line

  • @svh6195
    @svh6195 3 года назад

    Thanx!!

  • @anthonykihanga2881
    @anthonykihanga2881 Год назад

    Thanks alot

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @japhethm6103
    @japhethm6103 8 месяцев назад

    What readings should tell me that the resistance is not okay please

    • @rictorrictor888
      @rictorrictor888  8 месяцев назад +3

      depend on local regulation ..as lower as possible. .below 10ohm

  • @fidelcatsro6948
    @fidelcatsro6948 Год назад

    if we had no access to such equipment will adding more grounding rods to the ground all connected together potentially reduce the earth resistance?

  • @prabhus4137
    @prabhus4137 2 года назад

    Hi sir I have a doubt. Could you please tell me the difference between 2 point, 3 point method. In megger it has 4 terminals C1, C2, P1, P2. how to measure earth pit resistance?

    • @30mAkills
      @30mAkills Год назад

      Short C1 and P1 and connect to electrode under test. P2 is for potential and C2 is for current spike. This is known as 3 point or Fall of Potential method.
      4 terminals method is for testing soil as per Wenner method. This is for civil guys and not for electrical guys.
      Reg 2 point earth pit resistance testing: In India we don't/cant use this method because our public water supply is thru PVC pipes which is non conductor. Hope this helps.

  • @arturotakuma4742
    @arturotakuma4742 Год назад

    excelent ¡¡¡

  • @Bestofthebest383
    @Bestofthebest383 4 месяца назад

    I had an exams question in college how to do earth rod test . I didn’t pass it 😢

  • @azleeman
    @azleeman 3 года назад

    Saya nak tanya, bukankah testing dibuat semasa pemasangan rod sahaja (sebelum kita sambungkan dengan earth DB atau sebelum sambung ke perlindungan kilat)

    • @rictorrictor888
      @rictorrictor888  3 года назад

      Kedua2 nya boleh ..sebelum dan selepas ..Sebenarnya Cooper tape itu bukan utk pelindung kilat..

  • @Mike-ry4ti
    @Mike-ry4ti Год назад +1

    Your value of 1.63 ohms is a little high. Ideally less than 1 ohm is what you want...

  • @kennedymutuku8950
    @kennedymutuku8950 2 года назад +1

    Hello Sir,what if the result is above 10,let say 50..how can you improve this to 5?

    • @AutodidactEngineer
      @AutodidactEngineer Год назад

      Use a combination of vertical and horizontal grounding!
      My tip would be get copper/or in poorer countries galvanized pipe works well enaugh and install it in conjunction with galvanized steel bar/ or do the same but with copper if you can afford it!

    • @fidelcatsro6948
      @fidelcatsro6948 Год назад +2

      add more earthing rods all around the place the more the better🐱👍🏿

    • @neilblenkinsop2613
      @neilblenkinsop2613 Год назад +2

      All earth rod supplies these days are carbon steel with copper coating add to and go deeper using brass connection.

  • @ervingjonaj9082
    @ervingjonaj9082 8 месяцев назад +3

    music is shocking

  • @leomarbecilla2785
    @leomarbecilla2785 2 года назад

    hi sir. how do you perform it in a building where there is no earth ground to put the spike?

  • @yosuaabimo9379
    @yosuaabimo9379 9 месяцев назад

    Test ini apakah harus saat listrik off?

  • @lenslens7379
    @lenslens7379 2 года назад +1

    I think 1/RT = 1/R1 + 1/R2 + 1/R3

    • @SpecialVeloce
      @SpecialVeloce Год назад +2

      Sorry your Appying the wrong formula, it's average, not resistances in paralel

  • @loveandpeace594
    @loveandpeace594 Год назад

    thanks :)

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike in perpendicular ( left and right)direction is not correct.

  • @aruquest25
    @aruquest25 3 года назад

    The green wire is for?

    • @rictorrictor888
      @rictorrictor888  3 года назад

      electrode wire..

    • @olegkotletov7857
      @olegkotletov7857 3 года назад +2

      green wire is for grass. grass is green. make sense right? put green wire on grass and see resistance of grass. grass is green, green wire is green too. make sense right? right.

  • @wilsonloo8576
    @wilsonloo8576 3 года назад

    Hi Rictor , may i know how to know the result is good or bad? Many Thanks

    • @rictorrictor888
      @rictorrictor888  3 года назад +4

      low in reading is the batter .must below 10ohm.some time we can get 0 ohm. that the best..

    • @octaviohurtado2779
      @octaviohurtado2779 3 года назад +2

      It depends on your country standards. But the Best is the nearest to 0 ohms which is imposible to get 0 ohms. Also there are many methods to make the measurraments, it depends on your country standards too.

  • @islammaidul6999
    @islammaidul6999 2 года назад

    Overall resistance how is it calculation sir

    • @rictorrictor888
      @rictorrictor888  2 года назад

      Total of test 1 ,2 ,3 then / by 3..it show on video min 13.20

  • @Bwelz2010
    @Bwelz2010 Год назад

    Good, Thanks

  • @roannapigkit261
    @roannapigkit261 9 месяцев назад

  • @callishandy8133
    @callishandy8133 Год назад +2

    Good country with laws and people that know a well earth ground safe tere life, reduce EMC, lower the body contact voltage, ...
    Wow well electrician = You controlled (only optical) the ground connection boxes around the house. For the beginning well done.
    I hope you measure the low resistance later to be sure that the connections are not corroded.
    Fine work und knowledge ! Well done.
    Attention your result is influence of the premium earth groundind metal in the earth.
    Keep the measuring line far away or you get worse results. 2.10 Ohm is very very low = perfect but in my country I start thinking why is it so low ?
    Where is the fault to get these brilliant results ? Very wet earth ?
    Under the measuring line = really no water pips, no powerlines, no other pipes/metallsheets , ...
    What is hidden under the bid concret by the 2nd Spike movement.
    Testing the earth voltage = well done you know the users manual ! Perfect
    We use different instruments in europe (english version form page 37 to page 72)
    www.dehn.de/store/f/27628622/EBA/1805_060583_GEOHM_Messger%C3%A4t.pdf
    And other brands.
    My thumb up for your video.

  • @johnvillellegunas186
    @johnvillellegunas186 Год назад +1

    Hi sir. If floor is concrete, how to insert voltage and currrent spikes?

    • @fidelcatsro6948
      @fidelcatsro6948 Год назад

      break concrete and place into the soil below?

    • @30mAkills
      @30mAkills Год назад +1

      It need not be inserted. Wrap the spikes in wet towel and place them horizontally on the concrete floor with weights (stone) placed on the sack. Wet the whole area by watering.

    • @fje1948
      @fje1948 Год назад

      @@fidelcatsro6948
      Jesus, what planet are you on…..

    • @fje1948
      @fje1948 Год назад +1

      @@30mAkills
      Excellent explanation….

    • @fidelcatsro6948
      @fidelcatsro6948 Год назад

      @@fje1948 planet Kittygystan 🐱 of the 23rd Constellation, why do you ask amigo?

  • @ahmadwahab1641
    @ahmadwahab1641 3 года назад +1

    untuk apa select ke earth voltage?

    • @rictorrictor888
      @rictorrictor888  3 года назад +3

      kita uji dahulu jika terdapat voltage dalam tanah.. terutamanya di kawasan kediaman yang berdekatan dengan sub station

    • @fidelcatsro6948
      @fidelcatsro6948 Год назад

      kalau ada voltage baguslah pasang diode boleh charge bateri kereta anda🐱👍🏿

  • @aruniimalka6123
    @aruniimalka6123 3 года назад +1

    what is this aim?

    • @rictorrictor888
      @rictorrictor888  3 года назад +2

      Protect human and electrical equipment from electric short

  • @rjaramilloc
    @rjaramilloc Год назад

    Ese método no existe, tomaste medidas arbitrarias y sacaste un promedio... No tiene sentido.

  • @Андреич-с4н
    @Андреич-с4н 10 месяцев назад

    Why to use this device with long cables and sticks while THEORETICALLY one can get more relevant results using any household electric appliance like, say, Incandescent light bulb, a mulimeter and the old good Ohm's Law? One terminal of the bulb is connected to live (hot), the other to earth and the current is measured. Divide voltage by current and subtruct the bulb's resistance and the result is the earth resistance. What is wrong in such approach?

    • @Godfa539
      @Godfa539 8 месяцев назад +1

      The results would only be resistance on the load , not main earth resistance

    • @Андреич-с4н
      @Андреич-с4н 8 месяцев назад

      @@Godfa539 will you justify this statement please?

    • @hidennseek1483
      @hidennseek1483 6 месяцев назад

      I get what you mean and yes you can get accurate measurement through ohms wall but use a proper load resistor that is large enough to limit the current so the damage you will cause on the ground rod is limited.

  • @thunderhype5972
    @thunderhype5972 2 года назад

    Sub

  • @johnherbster5110
    @johnherbster5110 Год назад +2

    Much too long. Can't stand the music. Should begin with the schematic drawings.

    • @fje1948
      @fje1948 Год назад

      Music is beautiful. If you don’t like the sound, turn the volume down! What an inappropriate comment!

  • @AutodidactEngineer
    @AutodidactEngineer Год назад +2

    The test should be done preferably during the driest season to prevent moisture from ruinning your values!

    • @File-Transfer
      @File-Transfer 6 месяцев назад

      I have a question, engr. Why is it required in the earth resistance tester manual to damp the surroundings?

    • @AutodidactEngineer
      @AutodidactEngineer 6 месяцев назад

      @@File-Transfer I don't know about that

  • @dumindathusuth2026
    @dumindathusuth2026 Год назад

  • @GUDANGLAMPUSURYA
    @GUDANGLAMPUSURYA 2 года назад +1

    Om untuk mengetahui brp kedalaman grounding rod yg di tanam bagaimana ya ? 🙏

    • @GUDANGLAMPUSURYA
      @GUDANGLAMPUSURYA 2 года назад

      Apakah bisa di test dgn ohm meter tersebut

    • @rictorrictor888
      @rictorrictor888  2 года назад

      Kedalam nya sehingga rod gak bisa masuk lagi..baru di uji..jika masih tidak mendapat kan bacaan yg dikehendaki..buat point baru sehingga mendapat bacaan yg paling rendah

  • @gohpoikheng6030
    @gohpoikheng6030 2 года назад +1

    May i know why the cable for current is longer than the voltage?

    • @raemondbradford1629
      @raemondbradford1629 2 года назад +1

      When current is injected into the earth, then the voltage will change around the location of injection. The voltage reference cable spike needs to be some distance from the points where current is injected or removed, in order to try and find a location with minimal disturbance of earth voltage potential.

  • @robertotrinanes1744
    @robertotrinanes1744 2 месяца назад

    What about the grounding rod resistance?each rod shall be tested and removed all connected cable before the test of total resistance grounding.

  • @VlogSidah
    @VlogSidah 4 года назад

    Mantap tuan,done support ya,maaf lewat.. 🙏🙏

  • @salumhongo3955
    @salumhongo3955 Год назад

    You demonstrate this critical task to look easily, Thank you very much a learn a lot through your video.

  • @ohhappyday1548
    @ohhappyday1548 3 года назад

    thanks to your efforts, it is very helpful .. thank you..

  • @HENRYFANUELPHIRI
    @HENRYFANUELPHIRI 3 месяца назад

    Why the leads are in same line? pliz assist me sir.

  • @kalamsa7445
    @kalamsa7445 Год назад

    Without much noise around, explained in a simple practical way...Thanks Rictor

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @PbaY.
    @PbaY. 3 года назад

    mantap tutorial nya .👍👍🌟🌟🌟

  • @MNor-nb8sp
    @MNor-nb8sp 2 года назад +1

    What we do if earth volt not zero

    • @rictorrictor888
      @rictorrictor888  2 года назад +1

      Find another location for grounding the rod..

    • @30mAkills
      @30mAkills Год назад

      De-energize that service and procced if the voltage is more than 10.

  • @foonglikwei3913
    @foonglikwei3913 2 года назад

    This teaching very useful and very easy to understand. Thanks and appreciate it 😊

    • @30mAkills
      @30mAkills Год назад

      Shifting potential spike towards right and left is wrong.

  • @daspecialist1220
    @daspecialist1220 Год назад

    Attack of the silent explanation vid strikes yet again

  • @yghiduppastimatikelak8854
    @yghiduppastimatikelak8854 2 года назад

    Good job ...thanks for sharing..

  • @bruce.bchannel9046
    @bruce.bchannel9046 3 года назад +1

    Macam mna kalo erathing buat ats tnh bacaan bukit tu tnh...

    • @rictorrictor888
      @rictorrictor888  3 года назад

      tetap kena dapat kan bacaan bawah 10 ohm juga...tapi ada kaedah2 untuk menurunkan bacaan jika di buat atas tanah berbukit..tq

    • @bruce.bchannel9046
      @bruce.bchannel9046 3 года назад +1

      Sa lbih 15ohm bgtu

    • @bruce.bchannel9046
      @bruce.bchannel9046 3 года назад

      Nnti whatapps kmi 0138724857 mhu tnya kaedah lain

    • @rictorrictor888
      @rictorrictor888  3 года назад

      @@bruce.bchannel9046 boleh tambah point lagi tu..atau guna wayer tembaga bogel gulung jadi kan coil...tanam terus dlm tanah.hujung nya sambung ke electrod yang sedia ada..

    • @bruce.bchannel9046
      @bruce.bchannel9046 3 года назад

      Mcm mna cara ti

  • @KGL101293
    @KGL101293 2 года назад

    Hi, I have a Kyoritsu 4105A unit too, and I am getting "1. . ." reading at 20 ohm dial, who do you think is the problem, and how to fix this? Thank you.

    • @deutroitcity
      @deutroitcity 2 года назад

      It's over limit. U need to dial up the limit. Cannot use 20ohm. Because the reading is above 20 ohm

    • @nasiadomary4893
      @nasiadomary4893 Год назад

      How about if the reading is 25ohms
      What can i do to get less than 5Ohms?

    • @30mAkills
      @30mAkills Год назад +2

      @@nasiadomary4893 1. If possible increase the depth of electrode.
      2. Insert another electrode at a distance of at least twice the buried depth of 1st electrode and link both at top. Eg.: If 1 st electrode buried depth = 3 M then second electrode should be installed at a distance of minimum 6 M away and both should be linked with wire or strip at the top.
      3. Wet the pit by watering because dry earth is a bad conductor.
      Note : Chemical electrodes are fraud work. Hope all this helps.

    • @nasiadomary4893
      @nasiadomary4893 Год назад +1

      @@30mAkills
      Thanks🙏🙏

  • @joselitodupaya2092
    @joselitodupaya2092 3 года назад

    Thank you sir sa video

  • @castertroycabillar2863
    @castertroycabillar2863 3 года назад

    Sir what is the porpuse for higher ohms setting.is it same result as 20ohms setting.thanks

  • @TheElectricianOnHisMission
    @TheElectricianOnHisMission Год назад

    I have to perform this same test but outside of the building is all concrete, a shower room will be built in the basement but first the neutral to earth voltage needs to be tested, so how would I go about this?

    • @frankkennedy7831
      @frankkennedy7831 Год назад

      you silly person. what sort of system are you on?

    • @30mAkills
      @30mAkills Год назад +1

      Check with normal clamp or multimeter in volts mode between earth and neutral of any 3 pin socket connected to that service. The voltage value should be below 2. Hope this helps.

    • @fje1948
      @fje1948 Год назад

      @@frankkennedy7831
      Perhaps you are the silly person making such an inappropriate comment! 🤢

    • @nagarajah8930
      @nagarajah8930 21 день назад +1

      Sir ummmmmmmmmmbu

  • @stanleyozoilo1587
    @stanleyozoilo1587 Год назад

    What is the accurate value for best low resistance using Megger machine

    • @rictorrictor888
      @rictorrictor888  Год назад +1

      0 ohm

    • @30mAkills
      @30mAkills Год назад

      @@rictorrictor888 Practically not possible. Is earth full of gold?

    • @fje1948
      @fje1948 Год назад

      @@rictorrictor888
      I wish 😂