Explaining "Gas Furnace Basics, Operation, Efficiency, Parts" to Your Apprentice!

Поделиться
HTML-код
  • Опубликовано: 26 сен 2024

Комментарии • 96

  • @lpdoc3369
    @lpdoc3369 2 года назад +13

    Craig, you have opened my eyes to how things work through your videos.
    It’s amazing to see someone so good at explaining things online through video. Thank you for everything you do and you’ve helped me a ton.

  • @Epicurus_
    @Epicurus_ Год назад +15

    So much free knowledge on the internet, I love it

    • @acservicetechchannel
      @acservicetechchannel  Год назад +4

      Absolutely! Its a lot different than when I started in the trade! Make sure to check out www.acservicetech.com for more info!

    • @archietilghman1943
      @archietilghman1943 Год назад

      You are the Master of this field of HVAC/R teachings and instructions Sr.

  • @TheEV3RGRAND
    @TheEV3RGRAND 11 месяцев назад +1

    I love the detail in which this channel explains things.

  • @mykimikes
    @mykimikes 11 месяцев назад +1

    This guy is an amazing instructor. I went to automotive school and did a little hvac training. His explanation and detail makes me like hvac more amd more

  • @Sci-Five817
    @Sci-Five817 Месяц назад +1

    omgsh ty for this explanation, i really needed it
    😁😁😁😁😁😁😁😁😁😁😁😁

  • @masoudn5417
    @masoudn5417 2 года назад +10

    Thank you Craig for another great video, as always you are explaining the matter very clear and to the point. I hope you have more of these videos about the furnace coming up. GREAT JOB

  • @Tatman1212
    @Tatman1212 7 месяцев назад +2

    After watching this video, I feel like I can start my own HVAC company…and I don’t know anything about HVAC systems 😉

  • @danielleottway9431
    @danielleottway9431 Год назад

    Im heading into my second yr of class and Ive been watching your videos over and over trying to prep for class. Thank you!!!!!

  • @makeupaname1
    @makeupaname1 2 года назад +1

    I've been following you since I was in HVAC school...another great video.

  • @scottcarroll92
    @scottcarroll92 5 месяцев назад

    ngl vou have helped me so much with understanding HVAC and getting more comfortable with just general knowledge

  • @chesstime356
    @chesstime356 Год назад

    I saw this video few time still I like it it looks like first time to watch it. Every time I watch it I pick something new because I see it in real life maintenance work.

  • @roberts1159
    @roberts1159 2 года назад +2

    Craig, nice explanation on this subject. Thanks for sharing.

  • @sunriseeternity300
    @sunriseeternity300 8 месяцев назад

    always a great learning experience. #furnace #efficient #gasfurnace #hvac

  • @jonathanraul4086
    @jonathanraul4086 2 года назад +1

    Thank you for another great video good to see you back

  • @armadatint
    @armadatint 2 года назад +2

    Great video. Your very clear and top notch in your experience

  • @937jt
    @937jt 10 месяцев назад +1

    best video by far love it!

  • @celestialmycology134
    @celestialmycology134 2 года назад

    Thank you so much for the helpful video Craig!!! Mush love ✌️❤️🍄

  • @madcowusa4277
    @madcowusa4277 2 года назад +1

    Good video, enjoyed that overview.

  • @hasithamilinda500
    @hasithamilinda500 10 месяцев назад

    well explanation

  • @stevemar8593
    @stevemar8593 2 года назад

    EXCELLENT VIDEO AND EASY TO UNDERSTAND.

  • @combatcoal
    @combatcoal 2 года назад +1

    Man can you explain that with clarity. Thank you!

  • @user-hu4hx6bm6m
    @user-hu4hx6bm6m 2 года назад

    Best Gas Furnace Video

  • @mattchipman3776
    @mattchipman3776 11 месяцев назад

    Thank you so much for this video!

  • @wilfredovega577
    @wilfredovega577 2 года назад

    Wow. Ty for an amazing video and explanation of a furnace control..

  • @marsedhajdari1572
    @marsedhajdari1572 Год назад

    Very professional !!! Thank you

  • @logankollatt2857
    @logankollatt2857 11 месяцев назад

    Getting ready to buy your reference cards. Hope it covers this too

  • @chesstime356
    @chesstime356 2 года назад

    I really like it as always

  • @thesilentonevictor
    @thesilentonevictor 2 года назад

    Great explanation 👌

  • @soloch69
    @soloch69 Год назад

    Great video keep them coming I just picked up your work books and the Tec cards, can’t wait when you do a video on how to perform a efficiency test on furnaces, thank you for all the great videos enjoy your Thanksgiving you and your family🙏🏻

  • @shine-cg9uf
    @shine-cg9uf 2 года назад

    Great informative video, thanks.

  • @juniaejunioroliveira3265
    @juniaejunioroliveira3265 10 месяцев назад

    Good afternoon, how are you?
    I found your videos on RUclips and started watching some and they are really good. As I don't have very good knowledge of English, as I'm learning, I would like to know how your course works, is there an in-person or online school, or just material to study alone, how does it work?
    Thank you very much in advance

  • @deanmartin1966
    @deanmartin1966 2 года назад

    Another great video.

  • @dudewelder1756
    @dudewelder1756 2 года назад

    wow many thanks for education.

  • @tonyshepherd4738
    @tonyshepherd4738 10 месяцев назад

    Do you have any videos of dual pressure switch testing and operation? I’m still learning and out these and how to change just one of the two dual switches

  • @logzz6373
    @logzz6373 2 года назад

    Thanks again

  • @TV-dv5fq
    @TV-dv5fq 2 года назад

    Thank you

  • @matthewsummers7513
    @matthewsummers7513 9 месяцев назад

    Thank you for the video I really appreciate it! I had someone tell me that with a 90% or above if you don’t have a minimum set temp above 60 you can end up with early failure of the secondary heat exchanger. Like for a garage kept just over freezing. Was this a sales technique used on my friend or is there sense behind this? I’ve never heard this before and wasn’t sure if I should tell him yes or no.

  • @acci2003
    @acci2003 8 месяцев назад +1

    My HVAC Jman is great unfortunately he is ESL (English Second Language) and cannot explain this to me. For the last 8 months I've relied on AC Service Tech to teach me what he's been unable to. My Jman is a wizard at putting a new furnace/AC in and troubleshooting, however, he's not able to explain anything to me.

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 года назад

    Thanks again for the video!
    🍺🍺🍺🥃🥃🍿🎯
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

  • @GM-wf6el
    @GM-wf6el Год назад

    Hello. Great video. I live in an apartment and the gas furnace stops working during a power outage. Can I connect a vehicle battery or some other power source to the furnace so that it will run during power outage? Thanks

  • @KingRex12398
    @KingRex12398 Год назад

    So is the blower motor and the combustion motor running at the same time?

  • @rajjose7416
    @rajjose7416 15 дней назад

    I'm in Alberta Canada, last year winter, when it was about-35 deg c outside Furnace was unable to catch-up. Any advice please

  • @lancerudy6584
    @lancerudy6584 2 года назад

    Great videeo

  • @KavinSBS
    @KavinSBS 2 года назад

    Can you make a video about size piping and regular in LP

  • @MMorin-qy8jr
    @MMorin-qy8jr Год назад

    I have a Daikin gas furnace and the middle burner have rush on the plate of the burner, What Is the cause ? The in side of the heat exchanger seem ok and the burner too . What can cause that ?

  • @davidcooper4385
    @davidcooper4385 2 года назад

    XNLT VIDEO WELL DONE...

  • @gostofshadow831
    @gostofshadow831 2 года назад

    Could you do a training on ultra low nox?

  • @ziaddaya865
    @ziaddaya865 2 года назад

    I'm replacing my furnace and two different technicians have told me that they would seal the existing Return, and just use the fresh air intake and exhaust. Does this make sense? How can they just seal off the Return air/intake? Thank you

  • @efrainpelaez1246
    @efrainpelaez1246 Год назад

    Hello. Let me ask you some thing. The delta T of 50 degrees is only for hi efficiency furnace ?, or is the same delta for low efficiency ?
    Thank you !
    Blessings.

  • @danielthechskid
    @danielthechskid 2 года назад +1

    That's galvanized steel pipe being used for the gas feed not the proper black iron pipe. I hope that gets fixed too.

  • @potentialhvac6074
    @potentialhvac6074 2 года назад

    Awsome training session. Do you do trainings at supply houses?

  • @REFEREEMOUSE
    @REFEREEMOUSE 2 года назад +1

    Awesome video, I have bought your books and the material is great.
    I have a question, we have a furnace that is making a popping sound when it shuts off? Any ideas where to troubleshoot?

    • @clucknorriz6683
      @clucknorriz6683 2 года назад +1

      Check the sheet metal, sometimes when the unit shuts off and burners stop throwing heat it starts to cool down and that's where you get that contraction from the duct work.

    • @REFEREEMOUSE
      @REFEREEMOUSE 2 года назад +1

      @@clucknorriz6683 thank you

  • @gman3563
    @gman3563 2 года назад

    Have you had any issues with "smart" thermostats? I had an issue with my furnace the other night and it turned out to be the Nest. Everything would work up until it went to open up the gas valve and it would just click and then instantly shut down the furnace. I ran the C wire for the thermostat so it had constant power because i have heard that not having constant power can cause issues. I was just curious if you have seen issues and what you have done to make them more reliable and not damage the furnace. I currently have the old thermostat wired up for the time being as its starting to get cold and I no longer trust the NEST

  • @jamescollins8148
    @jamescollins8148 Год назад

    Thanks Craig! I have a question on a rollout sensor. I have a Carrier gas package unit. The rollout sensor is an automatic resetting button type. I ran a continuity test on it and got 0001, however when I taped the disc the numbers jumped all over the place. There was no rollout, however the exhaust was wide open (unshrouded) on the side of the unit. Any suggestions? Thank You!

  • @rpsmith
    @rpsmith 2 года назад +2

    I think you may have missed a step. Before the inducer motor is turned on, doesn't the controller board verify that the pressure switch is not stuck close?

    • @badassgrower
      @badassgrower 2 года назад +1

      No - inducer motor proves pressure switch which tells board to go ahead and send electricity to glow igniter. The combustion motor clears all gases that may have built up in heat exchanger so it doesn’t blow up .

    • @timrob0420
      @timrob0420 2 года назад +1

      Yes RP Smith you are correct, the IFC board first checks to see if the pressure switch is closed before ever turning on the inducer

    • @timrob0420
      @timrob0420 2 года назад +3

      @@badassgrower wrong. It does check to make sure the switch isn’t closed before it ever turns on the inducer motor

  • @partshnc
    @partshnc Год назад +1

    Fantastic video !Your thorough and well-presented explanation of the fundamentals of a gas furnace impressed me greatly. You have a clear grasp of the material, and I value your ability to translate difficult concepts into understandable language , for quality Furnace spare parts, visit us

  • @benjaminjohnson9198
    @benjaminjohnson9198 Год назад

    Craig, My heating system has been installed approximately 10 years now. I’ve never paid much attention, but I do know I have a high efficiency unit. PVC exhaust. One of the main things I’ve noticed after viewing your videos is that I DO NOT HAVE any outside combustion air installed. I’ve always noticed that when the unit kicks on if my basement door is open it actually slams shut. Did the company just skip this Combustion air intake.??? The unit was inspected by the township and passed. Is it code requirement to install outside combustion air..???

    • @DakotaHeatingAndAir
      @DakotaHeatingAndAir Год назад

      I would say thats a hack install, someone decided to skip running an intake it sounds like to cut down on time on the job. I've seen this issue where it drafts so hard because of no intake installed it puts out the burners for the water heater.

  • @kevinollivierre8801
    @kevinollivierre8801 2 года назад

    Hello morning I have a question I'll like to ask if you don't mind me asking

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 года назад

    👍

  • @andyfer7716
    @andyfer7716 2 года назад

    Thanks for an excellent video. I am wondering how the gas can be at 1/4 psi while normal atmospheric pressure is around 14 psi. Wouldn't the air want to rush into the gas line when the valve is opened ( instead of the gas flowing out)?

    • @justenhaight6429
      @justenhaight6429 2 года назад +6

      When referring to pressure inside the gas line, we are using pounds per square inch gauge, 0 psig is equivalent to 14.7 psia or pounds per square inch ambient.

    • @justenhaight6429
      @justenhaight6429 2 года назад +1

      So what he is referring to when he said 1/4 psig, is one 1/4 psi above ambient.

    • @andyfer7716
      @andyfer7716 2 года назад

      @@justenhaight6429 Ah that makes sense now. However, I'm still confused why he said car tires are 45 psi. Normally car tires are 32 psi....so on the psig scale that should be 18 psig, correct?

    • @justenhaight6429
      @justenhaight6429 2 года назад

      @@andyfer7716 car tire pressure is also rated as psig, so psia = 14.7 + 32 psig = 46.7 psia.

    • @justenhaight6429
      @justenhaight6429 2 года назад +1

      @@andyfer7716 car tire pressure is normally listed on the tire, and is usually the cold pressure of the tire, once the tire heats up the pressure will increase, passenger cars are typically rated at 32 psig cp, but the larger the vehicle and the more weight it has to carry, the pressure rating will be higher.

  • @dabig_guy2204
    @dabig_guy2204 11 месяцев назад

    Gas furnace parts

  • @gene4094
    @gene4094 Год назад

    These heating,(furnace) technologies are archaic. This engineering is stuck in the previous decades. The current furnace’s produced, must be changed for more safety and reliability.

    • @jasonwareing905
      @jasonwareing905 18 дней назад

      You should just be grateful living in a country that actually has great technology to heat your home ya spoiled American! Try heating your home by fire in a wood stove and be grateful for it.

  • @357-e2r
    @357-e2r Год назад

    I think your secondary is leaking .......

  • @lholama70
    @lholama70 2 года назад

    😅👍👍

  • @UltraHydrophobiccoat
    @UltraHydrophobiccoat 2 года назад

    I don’t like the general design which has the evaporator coil on the top. It’s very hard to clean up the evaporator coil. Evaporator coil at the bottom will be much better for evaporator coil cleaning.

    • @timrob0420
      @timrob0420 2 года назад

      Can’t do it like this with a gas furnace. Will literally void a heat exchanger warranty

  • @lcfr341845
    @lcfr341845 2 года назад

    1st 30sec I've heard 5 falicies. You should write down what you're going to say before talking.

  • @eclipse369.
    @eclipse369. 2 года назад

    Too much hand movement

    • @jasonwareing905
      @jasonwareing905 18 дней назад

      You'll be okay....go stuck on your thumb in the fetal position for a half hour.

  • @fuckjewtube69
    @fuckjewtube69 8 месяцев назад

    Compared to being a car technician this is like childs play lol. A modern BMW headlight is more complex than this...

  • @matts9629
    @matts9629 9 дней назад

    When are you coming out with a gas furnace book?

  • @jacksarisun6640
    @jacksarisun6640 2 года назад +1

    Thank you so much. This is a wealth of knowledge and I learn so much from your presentation.

  • @reliablehomeservicesinc8836
    @reliablehomeservicesinc8836 Год назад

    Hi,
    Great videos and info. I would like to see more videos on troubleshooting the new high efficiency 2 and 3 stage furnaces, now using algorithms and multiple dip switch options, etc. They are becoming more common and some of these advanced units can be tricky to understand and diagnose. Thanks

  • @gilbertopatino2616
    @gilbertopatino2616 2 года назад

    Awesome 👏 video, thank you very much🙏

  • @AJ-hx4my
    @AJ-hx4my 2 года назад

    Thank you