    @G1ZQCArtwork Месяц назад +13

    Hmmmm, odd question, that tube is metal, and therefore just shorting the probes, so why not just touch the cell contacts with the jaws together.!?
    These meters use Twin wires because the extra wire is a sense wire, to remove the resistance of the probe cables.!
    What am I missing.?

    • @dino6627
      @dino6627 Месяц назад +6

      By doing this the resistance of the probe cables is still not being measured, but the resistance of the tube and extra contact point will be measured. From the video it seems to be low enough, but I would prefer to use a plastic or foam insulator between the probe contacts to keep them apart and use them directly.

    • @JulianIlett
      @JulianIlett  Месяц назад +4

      Yeah, for some reason that doesn't work. If you just touch the closed probes onto the ends of a cell, the resistance reading is too high and very unstable.

  • @firasgh871
    @firasgh871 Месяц назад +1

    شكرا على الفيديو لقد تمنيت أن ارى ذلك من زمن

  • @tonyh6309
    @tonyh6309 Месяц назад +1

    A simple solution is to use 2 small magnets, eg. 5x5x3mm, with insulation between them, attached to a battery terminal. Then clip the Kelvin clips across the magnets. The bigger the magnets the greater the clamping force to the battery terminal, minimising resistance (or more importantly variation in contact resistance) during the measurements. Obviously the limit is how wide the Kelvin clips will open and the size of the battery terminal. This arrangement allows a hands-off measurement eliminating variations from varying hand pressure.

  • @EsotericArctos
    @EsotericArctos Месяц назад +3

    I have seen budget oscilloscopes from the same company. They are okay for general use, but found them quite inaccurate with measurements, sometimes 10 percent or more out on the measurements. It looks like this device may be slightly more accurate than the oscilloscopes, but maybe still a little out.

  • @vink6163
    @vink6163 26 дней назад

    An 18650 battery holder might be easiest - you could mount it on a wooden board and connect the probes (or even buy a four-pin connector and wire it directly to the battery holder) so measuring a bunch of cells is as easy as putting them in and out of the battery holder.

  • @stub1116
    @stub1116 Месяц назад +1

    When are going to do some more projects with microcontrollers' ?

  • @firasgh871
    @firasgh871 Месяц назад +1

    ماهو اسم الجهاز الأخر ورقم الموديل . ملاحظة : يجب على مصنعين البطاريات أن يكون النحاس الصافي المغلفن هو ونهاية التوصيلات حتى ةان كان على شكل برغي ويفضل صولية بفتحة للربط السهل مع بطاريه أخرى

  • @GadgetReviewVideos
    @GadgetReviewVideos Месяц назад

    one solution that comes to mind is putting an insulator between the clamps that keep them separated and then taking the ends and touching them to the end of the battery.

  • @johnch.8652
    @johnch.8652 8 дней назад

    las especificaciones del producto estan atras en la caja.

  • @waschbaers_werkstatt
    @waschbaers_werkstatt 13 дней назад

    Very nice, i dont think you can't make super accurate messurements, simply the fact how you messure (steel bolt +100%) i think its not the actual value shown on screen, more the fact if you messure the same way to all cells, so can compare them, to a degree. okay you should avoid steel bolts and nickel plated steel strips.
    i think i get one

  • @RichardSloan65
    @RichardSloan65 Месяц назад

    I haven't read the comments yet I'm thinking the copper tube might as well been left out

  • @vytautasslenderis2702
    @vytautasslenderis2702 24 дня назад

    Why did you insert those copper tubes? No need. Simply close the probes, the short length of the tips will have almost no effect. You still inserted another piece of metal, which may have even more effect on the readings, one more contact point. "Solving" one problem by creating another :)

  • @kapegede
    @kapegede Месяц назад +1

    How about testing inductors and capacitors in comparision to a Mesr-100 ESR meter?

    • @mauanderuk
      @mauanderuk Месяц назад

      Or for find shorts on PCB's

  • @ErrorMessageNotFound
    @ErrorMessageNotFound Месяц назад

    Do they have alternative probes available ?

  • @flagpoleeip
    @flagpoleeip Месяц назад

    The voltage reading 18650 Li-ion was exactly the same on both meters??? why did you say it wasn't?

    • @vink6163
      @vink6163 26 дней назад

      It wasn't exactly the same, there was about 10 millivolts of difference, which is relevant when it's supposed to measure to an accuracy of 0.1 millivolts. It would be like using meters that measure to the nearest volt, and one reads 3 volts but the other reads 103 volts. Quite a big difference given the precision it's supposed to have.

  • @lint2023
    @lint2023 Месяц назад

    What was that small scope you used?

    • @JulianIlett
      @JulianIlett  Месяц назад

      It's an Aarontek 30MHz, but there are dozens of small handheld scopes available now.

  • @craigtucker777
    @craigtucker777 27 дней назад

    I will NEVER buy something with scraped numbers off components, that means I can't repair it witch means I don't own it

    • @vink6163
      @vink6163 26 дней назад

      How would you repair something with a microcontroller in it that has embedded, locked, flash? You can read the chip number and replace it, but without the firmware it still won't function. So having chip numbers on it probably won't help with repairability. Scraping numbers off the chips is only done so they can use factory seconds destined for the rubbish and not get caught by the company that paid to have the chips fabricated, it's not done to hide anything from the buyer.

    • @craigtucker777
      @craigtucker777 25 дней назад

      @@vink6163 but they erase markings even on opamps, I dont care for their reasons, I'm not bying fnirsi and simmilar e waste anymore.

    • @craigtucker777
      @craigtucker777 25 дней назад

      @@vink6163 RUclips keep deleting my comments, why scrub numbers on opamp? Just no

    • @craigtucker777
      @craigtucker777 25 дней назад

      @@vink6163 so why from op amp

    • @vink6163
      @vink6163 25 дней назад +1

      @@craigtucker777 It probably didn't meet the specifications, or the batch was found to fail early, or had some other problem so the company didn't want it released with their brand name on it, so they told the factory to destroy them. But many Chinese factories just scrape the numbers off and sell them cheap for low-cost products where either they don't care if it breaks, or the problem with the component doesn't matter. The companies making the chips don't like it because it means people aren't buying their proper chips and they're not getting royalties, but it seems to be difficult to stop it from happening.

  • @singlesteve2011
    @singlesteve2011 Месяц назад

    you could of used a small peice of nickel strip spot welded to the 18650

  • @andyshap
    @andyshap Месяц назад

    Would a magnet work? Solder a block to the magnet and the probes grab the block. Attach magnet to the end of the cell.

    • @JulianIlett
      @JulianIlett  Месяц назад +2

      I've just checked a magnet - it's resistance is about 1.5mohm - quite a bit higher than the copper tube which was about 0.03mohm. Also, soldering to a magnet is problematic - heat damages the magnet.

    • @andyshap
      @andyshap Месяц назад +1

      @@JulianIlett it was worth a try! Thanks, Julian. I would think a battery holder would work

    • @Brian_Of_Melbourne
      @Brian_Of_Melbourne Месяц назад

      @@andyshap Clipping the Kelvin Clips to an 18650 battery holder seemed like the obvious solution as soon as the 'problem' was raised.

    • @juancarlossandoval5628
      @juancarlossandoval5628 Месяц назад

      Thanks foe the review. Have you check its accuracy? Planning to buy this for lion batts ang capacitor Internal resistance test job.

  • @rory9174
    @rory9174 6 дней назад

    I don't get it. So this is a very limited multimeter which only takes two readings, volts and ohms. What the hell use is it.

    • @JulianIlett
      @JulianIlett  3 дня назад

      Not many multimeters can measure down to 0.01 milliohms