FNIRSI HRM-10 Battery Internal Resistance Tester, Compared to ToolTop IR502

Поделиться
HTML-код
  • Опубликовано: 2 ноя 2024

Комментарии •

  • @GadgetReviewVideos
    @GadgetReviewVideos Месяц назад +9

    During my testing of the HRM-10 the voltage was very accurate. The only thing they need to change in the manual is the 0V-100V. It actually cuts off at 50mv and wont measure lower. Not a big deal since it’s not a volt meter and was accurate within spec compared to my other internal resistance testers. I actually like it.

    • @pault6533
      @pault6533 Месяц назад +2

      I would like to see “how low we can go” on both voltage and resistance and still be accurate. I partly wonder how much the impedance of the source affects the minimum amount of voltage measured. I would assume the source needs some sort of conductive response, otherwise the device thinks it’s finding an open circuit.

  • @jspencerg
    @jspencerg Месяц назад +1

    Thanks for your, as usual, thorough review. I think I'll get one to explore its low resistance measuring capability.
    Your repair videos of Bertan HV and electrophoresis machines gave me ideas and needed guidance to solve my devices issues. I hope you find another instrument that you'd like to share your repair or building process.

  • @guateque1718
    @guateque1718 Месяц назад +3

    Thank you. I have been disappointed by fnirsi several times but this tester sure seems to do what it says it can do.

    • @wtmayhew
      @wtmayhew Месяц назад +2

      The HRM-10 is quite a contrast to how badly their oscilloscope performed. I’ve got the GC-01 Geiger counter, and it isn’t too bad. The GC-01 appears to use a Russian gas tube. It is hard to mess up a Geiger Counter as long as the tube voltage is set correctly for appropriate sensitivity, all you’ve got to do is to count pulses. The GC-01 gives count rate as well as converting into several common dose rate values. I leave a GC-01 running for curiosity’s sake. I can tell when there’s solar flare because the alarm will trip more often when I have it set just above normal background count rate.

  • @pault6533
    @pault6533 Месяц назад +2

    There is a better option for flat-top cells. I use Kelvin dual-prong probes. Each pen has two sharp, gold-plated pogo pins that are closely spaced. At the other end is a fixed-spacing pair of banana plugs for red and black. All I have to do is clip the FNIRISI alligators in the open position to these two plugs. They fit very well in the pass-thru receptacle side of the banana plug end. I'm sure you have the same sort of probes somewhere.

  • @JAKOB1977
    @JAKOB1977 Месяц назад

    what is the lowest tolerances it will do on the ohm, is it down to 10 micro ohm res?
    If i recall, ain't it through the screen you enter on these modern Fnirsi LCD meters. you peel of the plastic front to access screws underneath but it ain't as straight forward as screws in the back.
    thx for the vid..
    user calibration....good to see.

  • @smichels5117
    @smichels5117 Месяц назад

    I am quite happy with my HRM-10. I have had it for several months and rely on it regularly. Thanks, Kerry, for confirming my results! Cheers!

  • @LawpickingLocksmith
    @LawpickingLocksmith Месяц назад +1

    OMG you get them gratis, I get jealous!

  • @jacek7178
    @jacek7178 Месяц назад

    Very interesting. Question: There is a Rel function (button) for cable calibration. I think you didn't use it for resistor measurement. 4-wire method is very exact.

  • @Electronic4U-david
    @Electronic4U-david Месяц назад

    thank you very much It was a good video😊

  • @harasti
    @harasti Месяц назад

    Nice video thank you.

  • @dogdipstick
    @dogdipstick Месяц назад

    Yea this one. is the one I got.
    Electric motorcycle/bicycle battery is either 72Vn ( 100V covers this without OL)... 96s DCV is another good nominal ( 120VDC cover this without Over Limit) ... very common.
    I will be comparing it to a 16 bit 32s pair of Revo DPL8s PL chargers on .xls logging 10 hz. It shows five digits after the zero on teh ACIR logs. Decimal accuracy of the DPL8s calibration is to +/- 1mA
    Measurement accuracy:
    Voltage resolution: 78uV (16 bit)
    Voltage tolerance: +/- 6mV

  • @wtmayhew
    @wtmayhew Месяц назад

    FNIRSI makes their cabinets really difficult to open. I have the little Geiger counter in what appears to be a yellow version of this case. To get it open, you have to remove four screws in the corners, peel off the rubber bumper, and it looks like there is also a screw under the sticker on the back. I decided to put my desire to do a teardown aside because it didn’t appear it would be possible to open the unit without destroying the sticker and losing the warranty.

  • @pault6533
    @pault6533 Месяц назад

    I suspect the center blue rectangle in the center of the back contains your key for disassembly. If you press on the label, do you feel a soft spot? Usually a label doubles as an anti-tamper device. Another trick to finding screws without peeling feet is a small smooth magnet, put it nearby and it will be attracted to any screws.

    • @Peter-rt3tu
      @Peter-rt3tu Месяц назад +1

      I've seen in another video that you can actually pop off the front panel with a spudger and then underneath you see screws in the four corners.

    • @pault6533
      @pault6533 Месяц назад

      @@Peter-rt3tuThat makes a lot of sense. Nice way to conceal screws, almost like a typical boot does.

  • @szekerespista3758
    @szekerespista3758 Месяц назад

    Can be used for capacitor internal resistance measurement too?

    • @KerryWongBlog
      @KerryWongBlog  Месяц назад

      Yes. The limitation is that the measurement frequency is fixed.

  • @martinda7446
    @martinda7446 Месяц назад

    Very cool. As I asked a question to myself... You answered it! You read my mind.

  • @robharley9838
    @robharley9838 Месяц назад

    Well done review, Metrology Masta' ! Thanks Kerry, always enjoy your explorations. - JRH

  • @pault6533
    @pault6533 Месяц назад

    I wonder how effective this would be evaluating the goodness of a dc power supply.

  • @dedskin1
    @dedskin1 Месяц назад

    what is this and why would i need it .

  • @ciprianwinerElectronicManiac
    @ciprianwinerElectronicManiac Месяц назад +1

    I was so upset when I saw that the FNIRSI hit the market, because I've got the YR1035+

    • @guateque1718
      @guateque1718 Месяц назад

      What's wrong with the YR?

    • @ciprianwinerElectronicManiac
      @ciprianwinerElectronicManiac Месяц назад

      @@guateque1718 The screen and the probes 😂

    • @guateque1718
      @guateque1718 Месяц назад +1

      @@ciprianwinerElectronicManiac I have the YR on my list. Hmmm might have to look at other options.

    • @ciprianwinerElectronicManiac
      @ciprianwinerElectronicManiac Месяц назад +1

      @@guateque1718 It is a very solid meter but those pogo stick probes are something a blessing and a curse, it would be great if it had both clips and pogo sticks. In my country the YR is more expensive than the FNIRSI.

    • @guateque1718
      @guateque1718 Месяц назад +1

      @@ciprianwinerElectronicManiac it's the opposite here. Fnirsi is a premium import brand here.

  • @SamuelRSands
    @SamuelRSands Месяц назад

    Mine turns on but doesn’t work/ measure