Hi. Thank You for this case! Can i ask? What about defense of anterior CA, and carotid vessel part in segment between stent-retriver and carotid stent, during the carotid stent implantation and balloon optimization? Thank You.
Thanks for kind explanation. How to remove microcatheter? Lenghth profile, solitaire 200cm and many microcatheters length150~ 160cm. Is this technique remove the microcatheter and stay stent retriver alone?
It can also be used with a 4mm Preset Lite because of the thinner pusher wire Or you go smaller with a 3mm Trevo, Preset, Solitaire etc that also have a smaller pusher wire
Congratulations!
Brilliant technique!
Excellent presentation!
Kostas Lagios
Μάριε είσαι εξαιρετικός!
Hi. Thank You for this case! Can i ask? What about defense of anterior CA, and carotid vessel part in segment between stent-retriver and carotid stent, during the carotid stent implantation and balloon optimization? Thank You.
Thanks for kind explanation.
How to remove microcatheter?
Lenghth profile, solitaire 200cm and many microcatheters length150~ 160cm.
Is this technique remove the microcatheter and stay stent retriver alone?
Great technique! But it means I have to use a small stentretriever for a large vessel due to the small pusher wire needed, right?
It can also be used with a 4mm Preset Lite because of the thinner pusher wire
Or you go smaller with a 3mm Trevo, Preset, Solitaire etc that also have a smaller pusher wire
Any ASPECTS cut off ? Because you don't want to give Anti-platelets in patients with low Aspects , as it increases the chance of bleeding
What's your Anti-platelet proctol for doing carotid Stenting in this setting?
IV ASS load with 500mg
CT next day and if ok load with Clopidogrel
Aspirin iv, 300mg; next day CT/CTA an decision for DAPT