Annual Maintenance & Cleaning Weil McLain Steam Boiler

Поделиться
HTML-код
  • Опубликовано: 12 янв 2025

Комментарии • 44

  • @KERRYWentworth-c5d
    @KERRYWentworth-c5d День назад

    Hands down, the best in the business. Pipe Doctor all the way!

  • @OzlemSule-z1v
    @OzlemSule-z1v День назад

    Pipe Doctor: where knowledge meets professionalism 👨‍🔧🔥

  • @KatheleenHurd
    @KatheleenHurd День назад

    Pipe Doctor is the superhero of home repairs! 🔧🦸‍♂️

  • @MrSprintcat
    @MrSprintcat 2 дня назад

    If I'm not drinking coffee while watching these videos these awesome videos I'm having a bowl of ice cream Mad Mike

  • @Semrailknur-tb4hn
    @Semrailknur-tb4hn День назад

    Watching this helped a lot!

  • @ModestaBlackman
    @ModestaBlackman День назад

    Watching your HVAC videos helped me fix my own AC. Thank you!

  • @zekenzy6486
    @zekenzy6486 День назад

    Great video. Thank you for sharing. Have a nice weekend

  • @lhasaboy0073
    @lhasaboy0073 2 дня назад

    Mikey Pipes,, thank you for showing everything your knowledge 👍🥃

  • @throttlebottle5906
    @throttlebottle5906 День назад +1

    the funny thing about asbestos and mesothelioma claims. it seems to not effect everyone the same, if at all, many people worked in factories where it rained down like snow flakes and hung like fog and yet they never had a breathing issue one, many still alive or lived to ripe old ages. I think there's far more to it and other compounds/contaminated air being breathed involved in the mix.

  • @ISIDROWalls
    @ISIDROWalls День назад

    A+ service, every single time. Can’t recommend you enough!

  • @DanielCroneSr
    @DanielCroneSr 2 дня назад +1

    White Ash deposits around a Pilot and /or Burners, Heat Exchangers which the gas burners are impinging upon, is from the use of aerosol sprays in the home or business which flows into the primary and secondary air mixing in and around the pilot and burners.🤔

    • @throttlebottle5906
      @throttlebottle5906 День назад

      that can also be from minerals in the air(humidifiers, as well as other steam sources like cooking can cause that), other gasses infiltrating into the home via the basement/crawlspace floor/walls can also cause that. many other household cleaning products. sometimes the supplied gas itself(propane or natural gas) cans do that from the odorant added(it builds up t higher levels at times). also candles, endless list :)

  • @Chris_In_Texas
    @Chris_In_Texas 2 дня назад

    I see you got one of the plasma arc lighters... Those work great, I hope you have had good luck with it. Just don't forget to charge it from time to time. 🤠👍

  • @benjaminwallace4626
    @benjaminwallace4626 2 дня назад

    PIPE DOCTOR = 💪

  • @TC_Tris
    @TC_Tris 2 дня назад

    I have a feeling I’m not the only one who was saying “Mike the valve is closed!!” Lol sometimes the simplest things we can’t see some days

  • @RAYFORDTavarez
    @RAYFORDTavarez День назад

    So glad I found this channel!

  • @BaranSibel
    @BaranSibel День назад

    Trust Mikey, he’s the best!

  • @DanielCroneSr
    @DanielCroneSr 2 дня назад +1

    The noisy pilot burner is “Sharp” with too much air to gas ratio. It will burn up the Thermocouple in short order, because it is excessively hot. The pilot orifice should be changed to one size larger which will quiet the pilot making it “Soft” , and cooling the flame, and thereby extending the life of the thermocouple.

    • @throttlebottle5906
      @throttlebottle5906 День назад

      too much gas pressure, it's chooching "full steam ahead", it probably blew out before in a down draft or was never set to start with. at least it;s not a big lazy no-air) flame with yellow tip sooting the boiler. although like that it will white ash it....

  • @captainwho1
    @captainwho1 2 дня назад

    Curious what the verdict was on the water loss. Is steam leaking out of the boiler or is the pressuretrol set too high or not functioning?

  • @waylonhartwell
    @waylonhartwell 2 дня назад

    When you stuck the camera into the bottom of the boiler looking at all the soot you could just see on the bottom of the one heat exchanger a lot more white, almost soot or something like it was dripping. So I suspect the heat exchanger is starting to fail and that's probably where his water's going up his chimney and down onto his burners

  • @MattGallo-k3f
    @MattGallo-k3f 2 дня назад

    Mikey Pipes , great content exceptional knowledge about your trades, I love watching the videos. How come you don’t work on oil fired boilers or furnaces? Is it just something you don’t like or not your forte? I have oil in my house and we don’t have access to natural gas, but I would go natural gas in a heartbeat if I could . So much cleaner in my opinion.

    • @PipeDoctor
      @PipeDoctor  2 дня назад +1

      I’ve never been professionally trained on oil fired equipment

  • @throttlebottle5906
    @throttlebottle5906 День назад +1

    I would guess that boiler is late 50's early 60's area.
    ** edit: actually, after seeing more of it overall, the paint color, size, plastic rivets on the badges, probably the late 60's to early 70's range.

    • @PipeDoctor
      @PipeDoctor  День назад

      You're right on the money with that guess!

  • @GrandviewLawnCare
    @GrandviewLawnCare 2 дня назад +1

    Hi Mike how are you

  • @unvjustintime1
    @unvjustintime1 2 дня назад +4

    I keep yelling at the phone the damn valve is closed.

  • @Chris_In_Texas
    @Chris_In_Texas 2 дня назад

    13:47 I am yelling at my screen that you have the fill valve closed. Need the tags! 🍺 Uncut, unscripted!

  • @kat2641
    @kat2641 2 дня назад +1

    😂 she be an old steam girl😂 if and I say ( IF ) my memory is correct the series 3 were manufactured between 1986 and I believe 1999 was the last manufactured .. I could be off a year or two either way that was a long time ago for my memory to remember, but regardless, she’s from the 80s “” back in the day when they built boilers to last forever hardly ever had to replace a cast-iron burner 😁” but regardless she be dam close to 40 years old !! A for her age she be looking dam good 👍 an working like a timex watch… Nice tune up on an old girl !!!

    • @throttlebottle5906
      @throttlebottle5906 День назад +1

      I first guessed late 50 to early 60's, but after seeing more overall, I'm going with late 60's to early 70's. overall size, badges held on with plastic push rivets, paint color, standing pilot with thermocouple vs power pile. not many steamers around here and not that many hydronics at all, but I've seen plenty over the years(worked on/replaced them too)

    • @kat2641
      @kat2641 День назад +1

      @ throttle bottle 🤷🏻‍♂️ it is very possible I just know when I was first introduced to them. granted I agree with you the paperwork and some of the parts do look more like the 50s~60s but my first experience was in 88 or 89 after I did a 10 year stent in the Army after I took some classes an worked for a Master an lol now I’m too old an too stupid to retire now 🤷🏻‍♂️ I go out almost everyday but I leave most to my guys an gals.. 3 of them call me pops an think I am breakable China an are way way over protective of me 🙄 it’s not like I got one foot in the grave .. but I would be curious when that unit was actually manufactured 🤔

    • @davidlabar-jn2ig
      @davidlabar-jn2ig 12 часов назад

      The EG series of boilers first came out in 1977 and is obviously still in production. The E series was 60s to 77 I think. This boiler still used push nipples and very heavily casted sections.

  • @GozdeGulhanim
    @GozdeGulhanim День назад

    True experts at work!

  • @dr.comforthvacr8889
    @dr.comforthvacr8889 4 дня назад

    ❤❤❤ hell yea!!

  • @scottvolage1752
    @scottvolage1752 2 дня назад

    Feed the People Mikey Pipes. Make the Trades great again. #LoveBosch Smash That Like Button and Subscribe folks.

  • @ThumperKJFK
    @ThumperKJFK 2 дня назад

  • @dannyg402012
    @dannyg402012 День назад

    Mikey, Question........
    You took off the Pigtail and water came out. The water level mark in black marker someone marked is about 2 inches about the float on the Miller No. 67.
    The fill valve is obviously bad overfilling, but why was the sight glass marked so high as "Normal Water Level" when it was still about 2 inches above the float on the No.67?
    On my 1962 National Boiler that still works like new since I replaced everything over the last 10 years the water in the sight glass is always perfectly in line with where the Float is on the No.67.
    I never got water out of my Pigtail opening when I take it off to clean it.
    Confused as to why water would be 2 inches above the float. Float in the 67 should show the same level of water in the sight glass.

  • @steverone7623
    @steverone7623 2 дня назад

    Chyeah

  • @domingod9394
    @domingod9394 9 часов назад

    Valve closed!!!!!!!!!

  • @steveblake8766
    @steveblake8766 2 часа назад

    405th Thumbs uP

  • @GurkanMediha
    @GurkanMediha День назад

    You make even the toughest jobs look like a breeze!