Trane Condenser Coil Replacement With Bonus Footage

Поделиться
HTML-код
  • Опубликовано: 10 янв 2025

Комментарии • 225

  • @HVACRSurvival
    @HVACRSurvival  4 года назад +14

    Sorry my viewers 🙄. I had a real nice soundtrack underneath the video but some jerk on RUclips decides to say it's not copyrighted music and then soon as I upload it it gets flagged so that I can't monetize my video. Total theft of my time. So I had to re-record and re-upload this again without the music. 👉👉If you haven't subscribed yet 👀, please consider doing so, and most importantly click that bell so that you're notified when the next video is released. Thanks for taking the time to view the video 🤜🤛... I truly do appreciate your time and comments. 👍👍👍

    • @hvacresidentialbasics7684
      @hvacresidentialbasics7684 4 года назад +1

      HVACR Survival Isn’t it fun dubbing over the work that you’ve already done. I’ve had to do that a couple times. But it does sound good

    • @sherwinalvarez7365
      @sherwinalvarez7365 4 года назад +2

      Wtf RUclips. We watch to see you work. The music just adds quality to an already fine product. Thats there loss. You know how many songs I got put on to before all the RUclips police stuff. Guess all these artists are gonna miss out on my 99cents.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      I know. What's bs is it's said royalty free.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I just pulled it out of my edit and then reformatted it and re-uploaded it. Takes about an extra 50 minutes to upload and process 😠

    • @DigitalIP
      @DigitalIP 4 года назад +1

      honestly, there are times where id rather hear whats being done in the vid instead of background music. But yeah, that sucks. Makes me curious what hardware you're working with that takes 50+ mins to do your edits.

  • @marvinsellers4457
    @marvinsellers4457 Год назад +2

    Had an old man tell me years ago show me someone that makes no mistakes and I’ll show you someone that’s doesn’t work hard . You da man really enjoy watching you in the many things you do . All ahead full Hoss

    • @HVACRSurvival
      @HVACRSurvival  Год назад +1

      Thanks for the kind words, I'm just doing what I can do.

  • @scottk0623
    @scottk0623 4 года назад +21

    Glad you didn’t edit the filter dryer install backwards. We have ALL done it. It shows your honesty and practical job experience. Nice job.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      Thanks, I agree, I try to be real and not pretend I don't screw up and have problems. Because I do 😲😏😁

    • @fishermankdk
      @fishermankdk 4 года назад +1

      Every filter/drier on my van is bi directional

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I have them, there nearly double to triple the cost for a sporlan.

    • @throttlebottle5906
      @throttlebottle5906 4 года назад +1

      DOHHHHH. just one of those days :)
      the best part is, I missed it being backwards because the big shhh smiley lol

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Your slacking 😁

  • @sherwinalvarez7365
    @sherwinalvarez7365 4 года назад +10

    I really like how you put that error in there. I really beat myself up when I make mistakes. Im basically a newbie. When i see a tech as good as you that i respect i have to remember it could happen to anyone. Don't get all defeatist, fix the problem and move on. Love your videos man. Keep them coming.✊🏽

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Sherwin that's really nice of you to say 👍👍. I'm just a average tech trying to help give the newer guys some extra resources to learn from.

  • @georgeian3243
    @georgeian3243 4 года назад +3

    You’re welcome. Trane did have some problems with tube rub leaks back in 2010 or so, particularly on the 14 SEER units as I recall. And, they were also having problems supplying replacement coils so the subcooler work around was actually a factory suggestion as a temporary repair until the new coil arrived. However, we found that the units worked very well without a fixed subcooler. It was only because of units being under warranty that many of the coils were replaced in the end. Another situation happened when a homeowner rammed a screwdriver through the middle of the coil for some unknown reason. No coil in stock and insurance wouldn’t pay for a new unit. Again, because that condenser is constructed of loops of spine fin, we simply isolated the damaged loop by cutting it off the discharge and liquid headers, brazing the cuts and put the unit back into service. All in all, a nicely designed coil, in my opinion.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I never thought about it till this video review 👍👍.

  • @TheLuckyman7726
    @TheLuckyman7726 4 года назад +2

    I now know how to take these apart. Thank you for this. I work on everything, even though my job is carrier specific. Nice to see this now I don’t gotta struggle like a botch.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +2

      We're a Carrier dealer as well but I've worked for Rudd and Lennox dealers but Trane is not a big seller in the residential side around my area. I mainly see them in the commercial market.

    • @TheLuckyman7726
      @TheLuckyman7726 4 года назад +1

      HVACR Survival I see here I don’t see to many of them but enough that it’s nice to know

  • @coolmandude1000
    @coolmandude1000 4 года назад +4

    Man i found 100s of Trane coils leaking in the same spot over the years. Fixing and replacing Trane units keeps my belly full lol.Not sure if you know or have seen any older Carrier units that also had the same Spinefin coils about 33-38 years ago. Actually my next door neighbor of 32 years has one of those Carriers with a spinfin coil and it is still working good. Just replaced the original 35/5 capacitor last week on a 101 degree day with 112 heat index. Also replaced condenser fan motor 2 years ago. Great video man keep up the good work. Peace

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +2

      🤣🤣🤣👍👍 have a great weekend, thanks 4 watching!

  • @evasmechanical3902
    @evasmechanical3902 4 года назад +1

    Great video Rick, i catch your live shows on the rerun, because of my hours. I learn more about attention to detail after watching your videos

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thanks Evas Mechanical👍👍. It's all detective work if there's not a dead HVAC system laying on the ground in front of you 😁. Asking the right people the right questions and build your case of what murdered it or abused it. 😲😎👍👍 (That's my version of the big picture analogy)

  • @georgeian3243
    @georgeian3243 4 года назад +2

    Nice work, very professional. As another commenter mentioned, you can bypass the bottom subcooler loop if it leaks down there. Depending on your climate zone, the subcooler might not be necessary; up here in Canada I’ve bypassed several leaks and the unit still operates spot on to the charts. The remainder of the coil will still subcool enough. BTW, if you need to change the compressor in an AC unit, (not so easy on the heat pump) strip down the unit and remove the coil as you did, now you have easy access to the compressor. Swage the discharge and liquid line then braze, evacuate and recharge.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      That's a good thing to know 👍👍i will definitely try that option to get a system back to operation in critical situations. Thanks for the tip 👉👍👍

  • @matthewgregory8218
    @matthewgregory8218 4 года назад +1

    Wow big job to replace the condenser box

  • @chrisrouleau693
    @chrisrouleau693 4 года назад +3

    Nice neat job Rick thanks for taking the time to make these videos we appreciate it

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      You got it Chris 👍👍. It took longer to cut it up than to do the repair 🤣🤣

  • @sivalley
    @sivalley 4 года назад +3

    Gotta love that pre-work-hardened mystery Chinese copper. Bitten me a few times with how easily it cracks under the SLIGHTEST vibration load.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      I believe that's made in the USA but I could be mistaken? 🙄

    • @sivalley
      @sivalley 4 года назад +1

      @@HVACRSurvival Yum, this crow is tasty. . . 😅

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      I could be wrong but who knows anymore 🤣

  • @JuanTodoli
    @JuanTodoli 4 года назад +2

    That last leak is just unbealievable 🤯

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I haven't seen you in a while, 👍👍 glad to see your still around, thanks 4 viewing it!

    • @OnePointLander
      @OnePointLander Год назад +1

      Agree, and the question is how?!?!? 🤔

  • @DWAYNE2ism
    @DWAYNE2ism 4 года назад +1

    Always a pleasure enjoying your workmanship

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      That's really cool of you to say👍👍🤜🤛 . I appreciate you taking the time to respond!

  • @stevealoia
    @stevealoia 4 года назад +1

    Well at least you seen it before you changed the system. I did the same thing. Got my SC set cleaning up system up and running . And dam. Filter drier in wrong . Lol I hate when that happen .

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I agree, it could have been worse just like that 👍👍

  • @deafhvacrsocal5292
    @deafhvacrsocal5292 4 года назад +1

    First of all I’ve always enjoy your videos. Man you looks very healthy and skinny that’s totally different from years ago. I remember that I used to watch your old channel. Keep it up sir ! 👍

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +3

      Thank you sir, I've lost about 80 to 85 lb. It makes life a little easier. It sucks watching what you eat but it's good all the same 👍👍

  • @ericrasmussen9892
    @ericrasmussen9892 4 года назад +2

    Just carry the bi-directional heat pump filter dryers and you're always right!

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      I have them but there about double the cost. Good idea otherwise 👍👍

  • @RayRay-nb7tn
    @RayRay-nb7tn 4 года назад +1

    Great find of a leak in that coil could be from vibration of the unit. Have to use nitrogen when brazing is the long term key. Its the old TXV. Bad belts causes lots of issues. Motor over heats, pulleys wear out, belt brakes, and low performance of the unit. Great video Rick. Like the material you cover. Thank you for the share.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      As always Ray, you have been a great supporter of my channel 👍👍 thanks man!

    • @RayRay-nb7tn
      @RayRay-nb7tn 4 года назад +1

      Rick you are very welcome. Love to support you always. Great guy doing great things. Keep up the great work.

  • @fastlife866
    @fastlife866 4 года назад +2

    Had one leaking at the bottom last week. Used solderweld al-cop was able to braze the copper to aluminum, saved them from purchasing a new coil.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      It's not sold around here, and getting my shop to buy something to sit on my truck in hopes of having it when I need it is slim pickings. I have heard it does well on aluminum.

    • @MrBaha2009
      @MrBaha2009 6 месяцев назад

      with same spot in coil . I did a lot of research about how to repair coil leak and I found products that would work well with this type of repair. Solder weld “ Alloy Sol “ comes with powder flux is best choice to repair aluminium coils. Thank you @fastlife for your comment it helps me to make my choice to repair the coil , if I succeeded it would save me a lot of money.

  • @berylwhite2983
    @berylwhite2983 2 года назад +1

    Your hey scared my poor 🐈 to death 😅 that's the first time you've ever scared the cat. LOL you did a great job

  • @Eddy63
    @Eddy63 4 года назад +1

    Good 1 Slick Rick ... We appreciate em all ...

  • @Trickp01
    @Trickp01 4 года назад +1

    As always, good stuff. Always learning and the commentary is absolutely priceless😊
    Cant wait for another one or a live stream.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thanks bud 👍👍I appreciate you checking it and leaving me feedback.

  • @johnt7502
    @johnt7502 4 года назад +1

    I’ve had those spun driers bust and spread bb’s through everything. Get rid of them at every opportunity. Great video. 👍

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I agree, I don't like them either 👍👍

  • @williamgildea8348
    @williamgildea8348 4 года назад +1

    Being a Trane dealership I can’t tell you how many of those coils I’ve replaced because of a leak in that s as same spot. Keep the videos coming 👍

    • @pelon542
      @pelon542 4 года назад +1

      trane is nothing but overpriced junk

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      They are all junk. I work on all brands and they all fail and they all are cutting corners to put more money in the shareholders pocket 😏👎👎

    • @clintgray1623
      @clintgray1623 4 года назад +2

      Just delete the bottom row of coils, old unit anyway saves bucks $$

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      That's what I'm hearing. News to me, I figured it would be higher head pressure.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I'd rather they just had replaced it 🤷🏾‍♂️

  • @AKStorm49
    @AKStorm49 4 года назад +1

    Luckily, I have not put a dryer in backwards (yet) but that's because my boss has and makes me check it 14 times before putting flame on it. Good videos.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +3

      It doesn't happen often, I was missing around getting the smoke alarm bypassed by the monitoring company and lost track of what I was doing. I figured it builds character 😏

  • @84DavidM777
    @84DavidM777 4 года назад +1

    I am looking for an aluminum coil so I can practice my aluminum repair skills. There is a guy in my company that is really good at it. He told me he had an aluminum coil and practiced over and over with propane gas. I have also heard cleaning the aluminum with alcohol.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I would like to try the solder weld kit 👍👍

    • @84DavidM777
      @84DavidM777 4 года назад +1

      @@HVACRSurvival Dude! A garage video on it would be great! Then you can add a por to pressure test. That's if it doesn't go to hell of course hahah

    • @dondesnoo1771
      @dondesnoo1771 4 года назад +1

      There's a outfit makes a low temp alum solder for auto use using a propane torch can fix a hole in a beer can .had some lost the name worked well for EVAP leaks .

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I have one like that and it did not work, I heard good stuff about solder weld and millhoff.

    • @dondesnoo1771
      @dondesnoo1771 4 года назад +1

      @@HVACRSurvival thanks

  • @philltafolla
    @philltafolla 4 года назад +1

    Good video Rick . I always install a sight glass on systems with large linesets . Not a big fan of those copper spun driers. Stay safe !!!

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      Just remember you can't charge a ac without a receiver by the sight glass. I have one on my heatpump just so I can see what going on inside 👍👍

  • @mr.chirinos5993
    @mr.chirinos5993 4 года назад +1

    Great video by the way!!

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thank you 👍👍. I'm glad you liked it.

  • @HughesManHVAC
    @HughesManHVAC 4 года назад +1

    Nice video Rick 👍

  • @Ted_E_Bear
    @Ted_E_Bear 4 года назад +1

    Great video today. You are the man !!

  • @HVACUncensored
    @HVACUncensored 4 года назад +1

    Great video brother. Finally able to check some of your videos out. Definitely good info bud. Keep it up. 💪🏻👊🏻🤟🏻

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thanks man 👍👍 I appreciate you taking the time to check them out 🤜🤛.

  • @hvacresidentialbasics7684
    @hvacresidentialbasics7684 4 года назад +1

    Nice video there buddy! Trane coils are definitely not that big of a deal to replace the trickiest part in my opinion is learning how to get those panels off

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Yeah, that took a minute to figure out but after a few days I got it 🤣🤣👍👍

    • @sivalley
      @sivalley 4 года назад +2

      @@HVACRSurvival Easiest way I learned to take them off is wear steel toes, grab the far sides with both hands, and give the bottom middle a tap kick while yanking upwards. Works 99+% of the time. The trick is to kick the panel like you're passing a ball to a little kid. Firm, but not crushing.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      That's a good analogy 😁👍👍. Thanks 4 the info!

  • @mk415030
    @mk415030 4 года назад +1

    Awesome video.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thank you! I appreciate you taking the time to watch it 👍👍

  • @teresaray-cp7vv
    @teresaray-cp7vv Год назад +1

    I have a 2012 with a Freon leak in the big coil you just put in . They gave me estimate of all day to remove put in the new one and around 2,000 should I look around ? It’s still under warranty parts not labor ,It is a traneYou made it look easy wish I could have you take a look at the heat pump .Thank you for this Video PS it’s really clean the coils are new looking I hose it a lot and it’s not where any grass or trees are

    • @HVACRSurvival
      @HVACRSurvival  Год назад +1

      This really depends on what's included in the quote? does this include new refrigerant? This was an R 22 system that stuff goes for over $150 a pound or more. I make it look easy because I've done it for 28 years. Like they say you're paying for all those years that I spent learning the trade not the couple minutes it took me to do it because it didn't always go that easy.

    • @teresaray-cp7vv
      @teresaray-cp7vv Год назад

      @@HVACRSurvival yes this includes R 12 I thought he said ?? He said it is a special blend they use so they can not use what’s left that haven’t leaked out .He used a snifter to fund leak however no bubble test .. I always wonder could it be sodered? He said they do not do that .Replace the unit is what they are recommending because it is 10 yrs old this July 2023

  • @joehead1294
    @joehead1294 4 года назад +1

    Where those kevlar industrial clutching belts?

  • @KG-yn9qi
    @KG-yn9qi 4 года назад +1

    Nice work , puts money in your pocket

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Yes it does and makes them happy to.

  • @richvacrdyazhi5532
    @richvacrdyazhi5532 4 года назад +1

    Great video!

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thank you for checking it out 👍👍

  • @donnierobertson3088
    @donnierobertson3088 4 года назад +1

    Nice job and video

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thanks Donnie 👍👍. I appreciate the view!

  • @Froggability
    @Froggability 4 года назад +2

    I'm curious, the original coil is copper/ali truly not fixable? Or didn't try?
    We usually braze repair at least 90% coil leaks no problem.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      The leak was in the aluminum not the copper. I have tried repairing a Trane coil once before and it did not work.

  • @alonsosalazar7326
    @alonsosalazar7326 4 года назад +1

    The clip on the fan cover is on the outside. It looks like it should be tucked behind the condenser grille.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I corrected it before I left. Good catch 👍👍

  • @jonathonpettit9418
    @jonathonpettit9418 Год назад +1

    I’m not sure if this will get responded to, but why do you put the filter drier on the inside ? I’ve always installed them in the outdoor unit side by the valves. Just curious. Cheers🎉

    • @HVACRSurvival
      @HVACRSurvival  Год назад

      Less likely to rust, and it's right before the metering device.

  • @davejohnsonnola2758
    @davejohnsonnola2758 4 года назад +1

    That Trane portion of the video looked high definition! Change of camera or I haven't been keeping up with you lately? As always, thanks for putting out content again.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I record at 1080 60fps, sometimes the lighting makes all the difference.

  • @joemartinez7619
    @joemartinez7619 4 года назад +1

    Crap happens " man " real world applications. Got to love it or get in a different field . Thanks for passing it forward.

  • @jkepps
    @jkepps 4 года назад +1

    Not a tech, so this might be a dumb question. Any particular reason to use a braze in filter/drier vs one with flare fittings for ease of future servicing/replacement?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      Possible leaks is why when your using R-410a and there was no isolation valves to change it anyway if I wanted to. Thanks 4 watching!

    • @jkepps
      @jkepps 4 года назад +1

      @@HVACRSurvival Thanks for the reply, that makes perfect sense. I never even considered the issues of higher pressures with R-410a. And DUUUHH no isolation valves, LOL.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      😁👍👍

  • @smellyjay7902
    @smellyjay7902 4 года назад +2

    Question? I have ac unit that is 18 years old, a tech said it was the compressor that was bad he is recommending changing the whole unit in side and out at a cost $3000 to $3500 for new system, in your experience is this true, or is it better to replace the compressor

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +2

      If it's R22 and 18 years old, I would replace it. That's a fair price.

  • @robwallingsford9274
    @robwallingsford9274 Год назад +1

    Did you purge with nitrogen during brazing? You don’t shoot for

    • @HVACRSurvival
      @HVACRSurvival  Год назад

      I had to rewatch the video since it's been awhile. Looks like I did nitrogen for the inside but the outside I did not because of the location of the service valves made it difficult. As far as your question on the vacuum, looks to me like I cut that section out because this was a simple job and didn't want to bore people watching paint dry. Let me ask you this, what kind of vacuum hoses do you use? What kind of micron gauge do you have? Do you pull every system down below 500 and have it hold below 500 micron for over a 30 minutes? Now be truthful

    • @robwallingsford9274
      @robwallingsford9274 Год назад +1

      @@HVACRSurvival I use Appion Megaflow 1/2” x 1/4” FL for every evacuation using only VCRTs-no more pulling vacuums through the service manifold. I use a BluVac + Pro micron gauge that performs the decay test. I purge nitrogen for everything I braze and I evacuate to at least 400 µm for everything. As everyone and HVAC should be, I am paid by the hour, and there are no shortcuts. I’ve seen the old timers set up the vacuum pump walk away and smoke a cigarette and come back and call it done because the gauge read 30 inches Hg. A lot of leaks get left behind that way.

  • @josemagallanes7779
    @josemagallanes7779 4 года назад +1

    Does the micron gauge give you an accurate measurement when placed on the vacuum pump?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +2

      At the pump is not the recommended location. It's better to have it either at a different location on the system being evacuated or on the valve core removal tool. This allows you to isolate the vacuum pump from the system and do a blank off test. This helps verify that the vacuum is not only deep but stays deep when it's isolated.

  • @joelwatts7786
    @joelwatts7786 4 года назад +1

    just curious why you didn't fit the drier at the condenser?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Two reasons, the big one is I can pump the system down and change it and the other is to prevent rusting of the metal shell after it has been brazed.

  • @mparker7739
    @mparker7739 4 года назад +1

    Almost like they knew it was going to go bad exactly 😂

  • @DigitalIP
    @DigitalIP 4 года назад +1

    Kinda annoys me when people dont keep bushes etc trimmed back away from units..
    So i asked on another channel also but... If after a customer had multiple visits from 2 companies that customer personally found the cause of a problem they were having was a stuck contactor (Not a bad CAP or logic board or high pressure switch like they were lead to believe was the cause), what would you do?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Sometimes it's hard to catch the problem if it won't act up while you're there. I try to look over the contactor and if there is any doubt about it or the capacitor they get changed. If it was mine I would call both companies and explain the issue, see how they respond. If they are reasonable they should either work with you on the bill or do something to make it right. At least that's what I would do.

    • @DigitalIP
      @DigitalIP 4 года назад +1

      @@HVACRSurvival Thats reasonable, But...
      Heres the thing... For the upstairs unit that i had replaced a few months ago, The old unit started acting up last year during a heat wave, the company i had at the time came out a total of 5 times total because they thought they fixed it but they didnt (It reset when they cut the power so when it started working normally they thought they fixed it) and it wasnt until i did some troubleshooting that i figured out what was going on. I found out that i could reset the unit by using the wet/dry switch, it would then reset the unit after the 5 minute delay and allow it to work for exactly 3 On/Off cycles before it had to be "reset" again to work normally. So since the company was full of idiots i got rid of them and went with a different company, which after seeing it for the first time immediately said it was because of the High Pressure Switch, supposedly because of an LED light being lit, though i didnt personally see it. So we had the whole upstairs unit replaced, which i do have to say i Loveeeee.
      A Few months ago the downstairs unit started doing the exact same thing and was able to again get it working a number of times before needing to be "reset". All of a sudden the unit started working Normally for nearly a month and then started acting up again a week or 2 ago. So i did some troubleshooting.
      They initially wanted to try replacing the logic board (Super Tinyyyyyyy little thing) and the CAP, wasnt spending $200+ for that so didnt happen.. So i took it upon myself last week and bought a $20 CAP of the same rating, that sadly didnt fix it. Then i remember seeing videos here n there mentioning the contactor and i did recall that something did look off with the contactor, so i nudged it a little and PLOP it came unstuck, there was a little rust/corrosion on the bits it would make contact with so i cleaned it up a little and the unit has been working flawlessly ever since, i'm sure the new CAP helped in some form too though.
      But yeah
      i'll consider what you said
      The next time i'll be seeing them is for Winter maintenance so i'll bring it up with the guy then, i likely will have him replace the contactor depending on its cost just in case though so it wont happen again.
      Sorry for the extremely large wall of text guys

  • @jonnymac31
    @jonnymac31 4 года назад +1

    Nice man.

  • @gregflorko8402
    @gregflorko8402 2 года назад +1

    I have a Trane XR15 condenser. It's 11 years old and the coil has a slow leak. How do I go about getting a replacement coil? I'm not sure if it's even available because the XR15 is discontinued.

    • @HVACRSurvival
      @HVACRSurvival  2 года назад +1

      I believe that's a 15 seer unit if I'm understanding their terminology of model numbers. They still make 13 seer evap coils and you can go to a higher efficiency evaporator if that's where it's leaking? you'll likely have to go through a dealer and they should be able to match something up.

    • @gregflorko8402
      @gregflorko8402 2 года назад +1

      @@HVACRSurvival Thanks.

    • @gregflorko8402
      @gregflorko8402 2 года назад +1

      @@HVACRSurvival It's leaking at the condenser coils. The evap is good.

    • @HVACRSurvival
      @HVACRSurvival  2 года назад

      @@gregflorko8402 find a company that has solder weld for aluminum and have them repair the aluminum spot that's leaking. It can easily be done now. Just got to find the right company to do it.

    • @gregflorko8402
      @gregflorko8402 2 года назад +1

      @@HVACRSurvival Thanks. That's what I was thinking. The HVAC tech that I had here said the coil is a combination of copper and aluminum and that it was not fixable. I don't recall his exact explanation. That company quoted me over $2,800 to replace the coil assembly or $4,000 to $6,000 (depending on tonnage) to replace the entire condenser. I told him that I didn't need an entirely new system. The indoor components, thermostat and evap coils are good. I asked him to clarify that the 4 to 6 thousand was for a condenser only with installation and he said that was correct. I'm seeing brand new condensers advertised on line for about $1,200. I've also watched RUclips videos that explain the process of replacing a condenser unit and it doesn't look like it's anything complicated. They drain the coolant from the old one, disconnect the coolant in and out lines and the power, level the mounting area, hook up the new one, braze the lines, charge the coolant and turn it on. I can't see that being over $1,000 worth of labor at the most. I think I was quoted about double what it should cost. It sounds to me like they're trying to take about $1,000 markup on the equipment and charge me another $2,000 for labor. I'm not hiring them to do the job. Can I order a condenser on-line if I'm not a licensed HVAC vendor? If so, who would you recommend? Thanks.

  • @Tjita1
    @Tjita1 4 года назад +2

    Are you still allowed to fill R22 in the US? It's been illegal in Sweden since 2005 i think.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +3

      On repairs yes, I believe until it's all gone. But we can't import it make it.

    • @GoatzombieBubba
      @GoatzombieBubba 4 года назад +1

      January of 2020 is when they stopped manufacturing R22.

  • @IslandbreezeMechanical
    @IslandbreezeMechanical 4 года назад +1

    Good vid

  • @Teegogetta
    @Teegogetta 4 года назад +1

    Two hoses for the vacuum?...just learned something

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      How many hoses do you normally use?

    • @prettycureforever7102
      @prettycureforever7102 4 года назад +1

      @@HVACRSurvival lol the normal 3 hoses

    • @Teegogetta
      @Teegogetta 4 года назад

      The setup for the vacuum threw me off for a second 😂😂 I'm use to the vacuum and manifold gauge set up but shit im green as hell i just order that field piece micron gauge

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      @@prettycureforever7102 if you want to speed up your evacuation times and eliminate several leak points you should try the 2 hose system with vcr tools. I never believed it until I tried it 👍👍

    • @tytig94
      @tytig94 4 года назад

      @@prettycureforever7102 I use 3 Schrader core tools, and 2 hoses. I learned it from AC service tech, and its a bit cheaper than HVAC Survival's method. Here's the video ruclips.net/video/wYZ8Wudksb0/видео.html A vacuum only takes me about 5-10 minutes depending on lineset run and system size with a 6cfm pump.

  • @mr.chirinos5993
    @mr.chirinos5993 4 года назад +1

    I wonder how much is that job? Probably same price as replacement of the unit?!!

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      Not every company is screwing the customer. Sorry to bust your bubble.

  • @HAGICASA
    @HAGICASA 4 года назад +1

    ur not the only one with the filter drier ....lol

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thanks Knoxville, I appreciate you saying that 👍👍

  • @JDT738126
    @JDT738126 4 года назад +1

    No nitrogen purge while brazing? :(

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      You're correct they're eagle eye, I needed to hook up the condenser coil before I could run my nitrogen through the system. I used it everywhere else.

  • @RJMaker
    @RJMaker 4 года назад +1

    Getting B/EMS involved...Oh heck no, that drier would be installed outside on my job. 10 min. tops and that's with wet ragging it. Not sure what the big deal is with everyone having a problem with installing driers outside. If done properly, the drier will outlast any of the crap ANY manufacturer is making today, including salt spray areas.. /rant anyway.. thanks for the video, Nice bonus material. :-)

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +2

      I use to always put them outside. I still will at times but I now try to do them inside for the 1% better chance of catching something before the metering device and the rust factor.

    • @Froggability
      @Froggability 4 года назад +1

      We braze the filter outside, a puff of zinc spray slows corrosion

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      @@Froggability Sounds good to me. I use to do it outside all the time. I even did mine at my house on the outside. But as time goes on I try to do it just little bit better than I did the last time.

  • @acrepairnearme
    @acrepairnearme 4 года назад +1

    How the copper pipe might leak refrigerant!?!?!?!??!?! is it real?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I'm confused if your asking or making a statement and if so what your saying?. The leak was in the aluminum. Not the copper.

  • @mansourramzey7711
    @mansourramzey7711 4 года назад +1

    I use jb weld on anything, why couldn't you use jb weld and let it fix the hole?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      There's several reasons why, (Warranty coat, safety, and professionalism) but the biggest one would be I've seen it fail to seal a refrigeration system multiple times.

  • @heavydiesel
    @heavydiesel 4 года назад +1

    A sharpie would have sorted the drier orientation issue!

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      Or just paying better attention 👀😁. I think it was more of me not paying closer attention and all the piping and electrical breaking the visual line of travel making it less obvious.

  • @publicmail2
    @publicmail2 4 года назад +1

    I wouldn't want aluminum on evap or condenser, they seem to leak bigtime over copper.

  • @sterlingarcher46
    @sterlingarcher46 4 года назад +1

    Such a bloody shame I can't get my hands on the tru blue hoses !
    My VACCUM pump is a joke compared to the Fieldpiece one , and I work on big systems with no oil separator , so you can Imagine how long it takes me to pull a bloody vaccum... Try to make my boss understand that we need better tools to do a better job but the answer is always the same : too expensive, you don't need them fancy tools to do a decent job , your colleagues manage just fine with what they've got ... I'm lost for words 😒

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I understand what your saying, people I speak with feel it's stupid to use them and don't want to learn the basic science of how these things work. After awhile I just worry about my self because in the end, I'm the only one I can control.

    • @sterlingarcher46
      @sterlingarcher46 4 года назад +1

      @@HVACRSurvival honestly if I could I'd probably buy them hoses for myself out of my own pocket, but I just can't find them over here , Accutools need to find a way to enter the European market .
      We're pulling vaccums with charging hoses , that alone doesn't make any sense if you pause and think about it , really ...

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      That's what I was doing 7 years ago. It will work just not as fast or as deep of vacuum.

  • @pelon542
    @pelon542 4 года назад +1

    the compressor will probably fail a few days later,i would never replace just the coil on a residential split system,unless it's a warranty job,

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +4

      Does everyone realized it was not my decision? If that's what the customer wants to do and they accept the responsibility. Who cares what they do. They were given the option to replace it and they chose not to. I can't twist their arm or beat him to a pulp until they buy it. LOL

  • @acunlimited9683
    @acunlimited9683 4 года назад +2

    you didn't put the unit back together very good tops not tucked in

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      I noticed it when I put the door back on for the electrical section. Good catch 👍

  • @matthewgregory8218
    @matthewgregory8218 4 года назад +3

    It’s a leaker mama

  • @alessichris07
    @alessichris07 4 года назад +1

    👍👍👍

  • @KadirYildiran
    @KadirYildiran 4 года назад +1

    Çok iyi 🖒🖒🖒

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Thanks 👍👍. Where you located?

    • @KadirYildiran
      @KadirYildiran 4 года назад +1

      @@HVACRSurvival Turkey in istanbul. It's great to watch how professionals from different countries work and great to interact with.
      I am using google translate, it may be wrong translation. I don't want to be misunderstood🙏

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      No your translation was perfect. That's really interesting, so how do you watch my videos if you don't speak english?

    • @KadirYildiran
      @KadirYildiran 4 года назад +1

      @@HVACRSurvival 😁😁 I know what you're doing. You describe the problem and explain what happened and some subtleties. Then you fix it. Yes, I don't really understand your language but I enjoy watching it. I am also repair small air conditioning systems and washing machines.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      That's really cool 👍👍. Stay safe out there.

  • @davefrattaroli5804
    @davefrattaroli5804 4 года назад +1

    Try this next time Trane KIT01146

  • @joeshearer1247
    @joeshearer1247 4 года назад +2

    I just delete the bottom of the coil- subcool loop is all it is

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      I'm not a Trane guy so it never occurred to me that button of the coil was just a extra capacity subcooler?. Someone else mentioned that as well, it's definitely something I will take into consideration next time. 👍👍

    • @joeshearer1247
      @joeshearer1247 4 года назад +1

      HVACR Survival I've actually deleted an entire circuit from the coil without any distinguishable problems as well ...just to keep in mind.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      That would have been handy if it was a critical unit. This one wasn't

  • @donaldpainter956
    @donaldpainter956 2 года назад +1

    That door isn't on correct

  • @HVACRNorth
    @HVACRNorth 4 года назад +1

    Woo0000🤘

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      Joe Joe, what's up my Canadian brother 👍👍. Thanks 4 checking out the video 🍺🍺.

  • @jimgarcia5165
    @jimgarcia5165 7 месяцев назад +1

    Isn’t it more practical just change the whole condenser unit?

    • @HVACRSurvival
      @HVACRSurvival  7 месяцев назад

      Speed of replacement is an issue right now. Things are slow to get.

  • @roscoebarnes1222
    @roscoebarnes1222 4 года назад +1

    Yeah I wouldn't have gave the option of repair..... That wouldn't benefit them in the long run. If the AHU was in good shape it would've got a new ID coil and outdoor unit

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      Not my call on what we do and don't quote and there maintenance guy knows what he wants.

    • @roscoebarnes1222
      @roscoebarnes1222 4 года назад +1

      @@HVACRSurvival yeah well I reckon that's job security

    • @HVACRSurvival
      @HVACRSurvival  4 года назад +1

      That's what I was thinking.

  • @bobgallo2178
    @bobgallo2178 4 года назад +1

    Good job. I suggest wearing gloves when handling coils, my hands are proof, lol.

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      It builds character. I have so many cuts and bruises it don't matter anymore 😏

  • @rickmiles2381
    @rickmiles2381 3 года назад +1

    The landscaper didn’t do you any favors. I did a coil and I spent 20 minutes cutting down vegetation grrrrrr

    • @HVACRSurvival
      @HVACRSurvival  3 года назад

      It's the same old situation🤦🏻👍👍

  • @clintgray1623
    @clintgray1623 4 года назад +1

    Just delete the bottom row
    . It is a old r22 unit anyway. They won’t notice a loss of capacity or effectiveness
    Save bucks$$

  • @TheNemosdaddy
    @TheNemosdaddy 4 года назад +1

    Who in their right mind pays for a condenser change out on an r22 system?

    • @HVACRSurvival
      @HVACRSurvival  4 года назад

      It was the decision of the board of directors and the head maintenance. This was for the basement and they technically didn't occupy that area of the building so it wasn't important to them. 🤷🏻‍♂️ You eventually learn to accept it's not your building and not your money. So whatever 😏

  • @reptilerob57
    @reptilerob57 4 года назад +2

    That's why I will never install Trane I'll walk away if a customer wants Trane installed and let it be someone else's headache

  • @steveblake8766
    @steveblake8766 4 года назад +1

    #382 thumbs up

  • @sknight0391
    @sknight0391 4 года назад +1

    #ShitHappens