Tan Delta testing of Current Tranformer (CT) - Theory & Practical Procedure

Поделиться
HTML-код
  • Опубликовано: 3 янв 2025

Комментарии • 58

  • @truptimali6856
    @truptimali6856 Год назад

    Thanks Sir for this Informative Video 🙂

  • @sisir22
    @sisir22 Год назад

    very nice elaboration abt tan delta testing, its easy & digestive, pronunciation is very clear. thank you a lot.

  • @subratamohapatra6478
    @subratamohapatra6478 Год назад

    Very good lecture.

  • @angrycap999
    @angrycap999 2 года назад

    Maa Shaa ALLAH zaberdast

  • @ahmedsalim1756
    @ahmedsalim1756 2 месяца назад

    should the frequency be nominal frequency or very low frequency?

  • @kananbiharibehera5749
    @kananbiharibehera5749 4 года назад

    Thank you sir,i gain more tips from this video, plz sir upload more video

  • @bibhubisoyi525
    @bibhubisoyi525 2 года назад

    Nice explanation

  • @KRISHNAKUMAR-pu9tq
    @KRISHNAKUMAR-pu9tq Год назад +1

    How tan delta = Ir/Ic
    Calculated using this data?

  • @indrajitchatterjee4752
    @indrajitchatterjee4752 2 года назад

    Helpful.Thank you

  • @surendrakverma555
    @surendrakverma555 2 года назад

    Very good 🙏🙏🙏🙏🙏🙏. Thanks

  • @karanparmar4754
    @karanparmar4754 Год назад +2

    What is tan delta point and where is it connected ,i am having a hard time understanding it.

    • @that90sguy77
      @that90sguy77 Год назад

      You have to open the CT terminal box under or on the side of the CT

  • @juakoedge
    @juakoedge Год назад

    Thank you for the information, i have a question: The HV terminal must be connected to the primary terminal of the CT, we all know CT's have 2 terminals, usally P1 and P2, do i have to short them, or just connect the HV to P1 terminal?
    In terms of secondary windings, theyre shorted and grounded, am i right? i whould be so grateful if you could clear my doubt

    • @substationtestingandcommis3452
      @substationtestingandcommis3452  Год назад +1

      P1 and P2 are internally connected, you should not short them.

    • @substationtestingandcommis3452
      @substationtestingandcommis3452  Год назад

      Secondary windings are connected to meters or relays.

    • @therisencomrade3452
      @therisencomrade3452 Год назад

      Secondary alrdy connected to meter and relay so, secondary is not open circuit even during tan delta test. The P1 is first remove from the main line only and then the connected to tan delta HV side. P2 is usually left like that since isolator is alrdy open during test(or maybe earthswitch need to be closed?) . I have performed this test once,I think we usually test with 2kV and 10kV at 50Hz and 100Hz frequency. The current being injected inside CT is around 100A.(For 132kV)

  • @asywadsaferi5565
    @asywadsaferi5565 Год назад

    Using gst mode do we need to connect to earth?

  • @parmodyadav9966
    @parmodyadav9966 2 месяца назад

    Sir I have make a wiring of new substation. Sir before charging of power transformer what we should test performed of power transformer and there protection and control system.

    • @substationtestingandcommis3452
      @substationtestingandcommis3452  2 месяца назад

      These tests are conducted before taking new Transformer in service:
      SFRA
      Open circuit test
      short circuit test
      Magnetising current test
      Magnetic balance test
      Vector group test
      bushing tan delta
      Winding tan Delta
      Winding resistance test
      Differential stability test
      Ref stability test

    • @parmodyadav9966
      @parmodyadav9966 2 месяца назад

      @substationtestingandcommis3452 sir please make a video of testing of power transformer and there protection and control devices

  • @Assistant_User
    @Assistant_User 2 года назад

    Thank you. In which standard appears values of permissible limits shown for Tan Delta?

  • @ravikumarkoyyana12
    @ravikumarkoyyana12 3 года назад +1

    If tan delta point is not available in CT,then where to connect the Tan delta terminal of the kit

  • @anilshemade6048
    @anilshemade6048 4 года назад

    Good info...If ct has no tan delta point,then where the lv lead of the kit be connected?

  • @rushirajsinhsolanki2990
    @rushirajsinhsolanki2990 4 года назад +1

    CT secondary terminal short and measured??

  • @aviralsingh2776
    @aviralsingh2776 3 года назад

    Nice man

  • @tb.casenjo2680
    @tb.casenjo2680 3 года назад

    in which standard appears this procedure?

  • @ashishvitekar3474
    @ashishvitekar3474 2 года назад

    Sir,
    When tan delta Test required?
    As per your best explanation I realized as same as IR Test done by HT megger.
    Can we this test by HT megger?
    Thank you very much

  • @substationtestingandcommis3452
    @substationtestingandcommis3452  4 года назад

    Recommended Videos:
    Power Transformer Nameplate Details Explained in Hindi : ruclips.net/video/6HrTgIOZC5k/видео.html
    Difference between Metering CT and Protection CT: ruclips.net/video/VSwLHAZLj6Y/видео.html
    CT Nameplate Details Fully Explained: ruclips.net/video/eznFythQz3c/видео.html

  • @vinodmusicprogamer9503
    @vinodmusicprogamer9503 2 года назад

    What if cvt and CT tan delta points are not earthed plz reply

  • @CutieSamriddhi357
    @CutieSamriddhi357 3 года назад

    If we left the tan delta point in grounded then what happens

  • @RAMBABU-gk8kx
    @RAMBABU-gk8kx 2 года назад

    What's UST and gst mode

  • @garvalnaran9972
    @garvalnaran9972 8 месяцев назад

    Good

  • @sjamesking6605
    @sjamesking6605 2 года назад

    Thanku

  • @ashok2m
    @ashok2m 4 года назад

    Great

  • @النخاعدزيري
    @النخاعدزيري 3 года назад

    شكرا

  • @deesingh3330
    @deesingh3330 2 года назад

    Thank u so much sir for sharing your knowledge 🙏🏻 ..& purely explanation

  • @AnilKumar-bz4rj
    @AnilKumar-bz4rj Год назад

  • @mathewsksamuel6508
    @mathewsksamuel6508 Год назад

    hello bro

  • @fazleazim8125
    @fazleazim8125 7 месяцев назад

    great

  • @birbahadurpal5080
    @birbahadurpal5080 Год назад