TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?

Поделиться
HTML-код
  • Опубликовано: 2 окт 2024

Комментарии • 156

  • @kabarotv6591
    @kabarotv6591 2 года назад +4

    The best channel for all the electrical works onboard a vessel.

  • @srujan-eh6mz
    @srujan-eh6mz 2 года назад +2

    You are explaining like very cool and with patience ☺️

  • @edgar5608
    @edgar5608 2 года назад +3

    Awesome, another well done job.
    As a still inexperienced Engineer, I would really like to sail with you. Im sure that I would learn a lot. And just having really good colleagues like you would for sure keep one motivated to constantly improve :)

    • @leckyjake
      @leckyjake  2 года назад

      thank you for your support

    • @niky7197
      @niky7197 Год назад

      No I go with him... 😠

  • @warnadisuwarlan6606
    @warnadisuwarlan6606 Месяц назад

    Thanks so much for your sharing brother.

  • @bassamrajjoub9843
    @bassamrajjoub9843 6 месяцев назад +1

    God bless you teacher

  • @bassamrajjoub9843
    @bassamrajjoub9843 Год назад +2

    Thank you master.God bless you.

  • @mahmoudmoussa9687
    @mahmoudmoussa9687 2 года назад +1

    I totally agree with u and you are really amazing 👏

  • @dmitriibugayov6975
    @dmitriibugayov6975 5 месяцев назад +2

    I can be wrong, but Superheat is the amount of heat added to a vapor above its boiling point. As a result, it shows the amount of heat your Freon has gathered over time.
    This means that the evaporator is frozen because you have too LOW superheat, but not too high! Too much Freon goes through txv and in the video you are reducing the quantity of Freon and that is why increasing superheat. Am I correct, colleagues?

    • @lambertobaldovino4535
      @lambertobaldovino4535 5 месяцев назад

      Parehong tama ang explanation ninyo sir jake and Mr. bugayo pero ang tingin ko ang problema nasa spring tension,dahil na rin sa sobrang ice build up umabot hangang feeler bulb.kaya kinulang nang bukas ang expansion valve .yong pag adjust ni sir jake counterclockwise ay nagbalik sa tamang opening uli yong txv.hope nakatulong sa pag analyze nang problema.

    • @davidsanders6957
      @davidsanders6957 2 месяца назад

      🎉

  • @smileforever3486
    @smileforever3486 6 месяцев назад +2

    isn't the TXV supposed to automatically adjust the amount of refrigerant passing through by sensing the refrigerant temperature at the output of the evaporator coil?

  • @reefercontainerph4182
    @reefercontainerph4182 2 года назад +1

    Very Informative video sir! thanks for sharing

  • @oleksandrchernov2781
    @oleksandrchernov2781 Год назад +11

    Very good video. For defrosting vegetable room better disconnect power supply for solenoid valve and keep running fan for 2-3 hours- also very good way.

    • @vedranpejic8906
      @vedranpejic8906 9 месяцев назад +1

      And temp.will fall down more than it should

  • @TheBTheBeurope
    @TheBTheBeurope Год назад +5

    That's why there is a method called ''DEFROSTING''
    (1) Stillstand - Shutting the system till the ice melts
    (2) Let the fan only run in the evaporator
    (3) Heating rod in the evaporator.
    (4) High-Pressure hot gas flowing pipe from the compressor directly to the evaporator.
    All the above-mentioned processes apart from the 3, are automated and have time intervals.
    You adjusted the TEV by turning counterclockwise. This means you opened the valve more. This means more refrigerant is sprayed in the evaporator. When more refrigerant is sprayed in the evaporator, it gets cooked more slowly ( turns to gas form more slowly). This will result in the refrigerant leaving the evaporator in a semi-liquid state. This will result in very low SUPER HEAT.
    I don't think you have solved the problem.
    The temperature in the vegetable room seems to return back to normal because after you cleaned the ice block from the evaporator the fan is circulating the air in the room properly. But soon ice block in going to form in the evaporator and the same problem returns back.
    Instead of adjusting the TEV, you should have checked the DEFROSTING system's functionality.

    • @niky7197
      @niky7197 Год назад

      It has no Dfos system....

    • @davidsanders6957
      @davidsanders6957 2 месяца назад

      Also, liquid leaving evap will "slug" compressor

  • @davidmears9410
    @davidmears9410 2 года назад +5

    I hope you are the top paid sparks in Maersk. Such a range of skills.

  • @heavydiesel
    @heavydiesel 2 года назад +7

    Interesting vid!
    I work on a lot of really old systems, have seen a few TXV's where the inlet filter has become blocked with dirt. Also have had a few where systems have been converted from CFC's to HFC's where the TXV has got wax in it which also blocks the flow.

    • @leckyjake
      @leckyjake  2 года назад

      thanks

    • @rustblade5021
      @rustblade5021 2 года назад +3

      yes it is probably clogged or faulty txv but this works fine for temporary fix

  • @gregdekkers2667
    @gregdekkers2667 Год назад +2

    If you have to adjust the TXV to solve an issue that wasn't there before with similar settings I would say the TXV is faulty or you possibly miss something else (blockage around inlet TXV?) and are solving a problem by offsetting your TXV. (P.S. I sailed on he same vessel as you in 2009 - Maersk Salalah.)

  • @johnthompson9918
    @johnthompson9918 2 года назад +6

    Should you check for superheat with a thermometer and gauge pressure prior to adjusting valve? I hope so.
    The room doesn’t look like a new installation. Possibly worth replacing the TXV completely if it isn’t functioning ok

    • @davidsanders6957
      @davidsanders6957 2 месяца назад +1

      Can't find a parts house in the middle of the Atlantic Ocean 😮😮😮😮

    • @johnthompson9918
      @johnthompson9918 2 месяца назад +1

      @@davidsanders6957 isn’t there a refrigeration wholesale down just off Bedrock Road? 🤪

  • @Marineelectricalknowledge
    @Marineelectricalknowledge Год назад

    Please do video on refrigerator cycle system.

  • @maheshkumarsubramani5329
    @maheshkumarsubramani5329 19 дней назад

    When txv supplies more refrigerant ice will form on evaporator right .?
    If supply refrigerant too small how ice will form.
    Might be temperature not in level. Okay

  • @bebeusxl9842
    @bebeusxl9842 2 года назад +1

    Great video as always! Could you perhaps sometime in the future make a video on how to perform safety checks for the ME, Diesel GE, Emergency GE and Boiler?

    • @leckyjake
      @leckyjake  2 года назад +2

      currently editing video regarding previous boiler trouble

  • @LucasOli09__
    @LucasOli09__ 4 месяца назад

    Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?

  • @ΜΑΝΩΛΗΣΖΩΝΟΥΔΑΚΗΣ
    @ΜΑΝΩΛΗΣΖΩΝΟΥΔΑΚΗΣ 5 месяцев назад +1

    thank you for ur time to show us problems of recarding ac and provision systems on board. the line after the expansion valve can be icy but when the TEV is icy this means that a sudden drop of pressure happens before the TEV which can be caused if the TEV filter is dirty.

  • @migz4360
    @migz4360 2 года назад

    sir thank you for the video..

  • @babaolowo35
    @babaolowo35 2 года назад

    Thanks 👍

  • @nivri88
    @nivri88 Год назад +1

    Hey bro just have a question right above the TXV all the way to the evaporator was filled with ice what you think causing it? it’s a little condensing unit..thanks

  • @KamaleshSellamuttu
    @KamaleshSellamuttu 4 месяца назад

    Dear Lecki Jake, if there is too little refrigerant in the evap. coil, it will get excessively heated up ( high superheat ), resulting in sensing bulb opening the txv to admit more refrigerant to the evap. coil, however you state that there is too little ref charge in evap.coil due to high superheat - could you please clarify this? thanks

  • @muhammadfaridsulton5668
    @muhammadfaridsulton5668 11 месяцев назад

    Hello mr lecky. I am also electrician of the ships. I want to learning with you about cold storage no cool because having ice on expansion valve. I ask to you what cause this ? Please help me

  • @StoweLauren-t1c
    @StoweLauren-t1c 22 дня назад

    Rodriguez Frank Gonzalez Michael Smith Helen

  • @danishmomin8102
    @danishmomin8102 2 года назад +1

    why back pressure valve is provided in veg room?

  • @tsalikistsalikis3118
    @tsalikistsalikis3118 2 года назад +3

    THAT'S WHY YOU SHOULD ALWAYS USE EVAPORATORS WITH HEAT ELEMENT AND TIMER FOR DEFROST NOT ONLY FOR TEMPERATURES BELOW ZERO BUT ALSO FOR TEMPERATURE ABOVE ZERO WITH HIGH OR LOW HUMIDITY IN THE COLD ROOM.
    AND YOU WILL NOT SEE FOR EVER ICE IN THE FINS OF YOUR EVAPORATORS.
    NEVER TOUCH/TRY TO ADJUST THE EXPANSION VALVE BECAUSE IT IS FACTORY ADJUSTED WITH THE CORRECT SUPER HEAT.
    CHOOSE THE CORRECT ORIFICE.
    KEEP THIS ADVICE FOR THE FUTURE.
    THANKS FOR READING 🇬🇷

    • @officerkrupke4966
      @officerkrupke4966 2 года назад

      Stewards dept. leaving doors open all the time. I cant believe that system came without defrost heaters..

    • @tsalikistsalikis3118
      @tsalikistsalikis3118 2 года назад

      @@officerkrupke4966 YOUR OPINION Sir.

    • @tsalikistsalikis3118
      @tsalikistsalikis3118 2 года назад

      THAT'S WHY WHEN THE DOOR IS OPEN,
      IT'S SHOULD GIVE THE DOOR SWITCH,
      THE ORDER TO CLOSE THE SOLENOID VALVE AND FANS TO STOP.
      IT DEPEND FROM THE ORDERS YOU GIVE TO THE ELECTRICAL PANEL.

    • @officerkrupke4966
      @officerkrupke4966 2 года назад +1

      @@tsalikistsalikis3118 That still isnt going to get rid of the high humidty air introduced each time room is accessed. Need after market defrost heating strips installed with timer to initiate and shut off solenoid and fan.

    • @tsalikistsalikis3118
      @tsalikistsalikis3118 2 года назад

      @@officerkrupke4966 DID YOU READ MY LAST COMMENT ?
      I THINK YOU AGREE WITH ME.
      SAME SENSE WITH DEFERENT WORDS.

  • @FrankMatawai
    @FrankMatawai 5 месяцев назад +1

    Very well explanation done. Thanks 🙏

  • @tomasmahuis-teles1976
    @tomasmahuis-teles1976 Месяц назад

    Good video , l have a question why the line of the line low side , is getting a little frosty, on a walk in freezer

  • @davidsanders6957
    @davidsanders6957 2 месяца назад +1

    You the man !

  • @alegreberlin4628
    @alegreberlin4628 Месяц назад

    How about walk in freezee sir icy on expansion valve,

  • @fabiantajale2576
    @fabiantajale2576 Месяц назад

    Good day sir what the issue the TXV is cold.. but indoor is not cold

  • @mototechtv.3774
    @mototechtv.3774 4 месяца назад

    fly high lodz rest in peace lodz

  • @mariyaan1545
    @mariyaan1545 2 года назад

    Thank you sir

  • @El_Robinson
    @El_Robinson 2 года назад +1

    Great Video!!! Thank you for sharing.💯💯

  • @franzduhina2475
    @franzduhina2475 Месяц назад

    ser paano kng ice yung evarotor my tendisi ba expansion valve ang problema

  • @vamshikrishnagadde199
    @vamshikrishnagadde199 5 месяцев назад

    Hello lecky have a nice day
    Actually I am on the same ship which you have done that vedio regarding the ice formation in veg room. I have adjusted the TXV but still same the ice formation please suggest what to do

  • @rohilkumarsaini9126
    @rohilkumarsaini9126 2 года назад +2

    Thank you sir for sharing wonderful knowledge.

  • @alterator
    @alterator Год назад

    Good

  • @TenaHosan
    @TenaHosan Месяц назад

    Johnson Frank Anderson Maria Lewis Sharon

  • @Mohammad.faizan.technical
    @Mohammad.faizan.technical 4 месяца назад

    Which ac is it

  • @scorpiomarine-electrocutio7460
    @scorpiomarine-electrocutio7460 2 года назад +1

    Thankyou for this video sir.

  • @rubenereso5805
    @rubenereso5805 5 месяцев назад

    Nice 👍👍 Sir 🙏 I have good learned for your discussion about the refrigeration thank you so much Sir👏👏👏👍👍👍

  • @marinonglubas6103
    @marinonglubas6103 Месяц назад

    Rip sir lecky laki tulong talaga mga video mo 😊

  • @acmell3173
    @acmell3173 2 года назад

    Great explanation, btw sir you are RAC TEHC.?

    • @leckyjake
      @leckyjake  2 года назад

      I am an Electro Technical Officer onboard a ship

  • @sherwinladera5818
    @sherwinladera5818 2 года назад

    hey lecky ...how to apply to your company ...i am HVAC/RAC TECH. ..6 years experience

  • @rahmansaleh5695
    @rahmansaleh5695 Год назад +1

    Good job bro 👍👍👍

  • @Cathay2017
    @Cathay2017 Год назад

    Actually you need not to adjust expansion since it is a factory set. Adjusting is only be done in case of emergency. The icing of of evaporator not clearly emphasising the major cause.There is one big reason why icing occurs immediately. It is always the fault when malfunction of one component but pointing to expansion valve is really not the real thing at first.

  • @tamilcooking4685
    @tamilcooking4685 Год назад

    Thanks brother for this vedio.
    I want to know when all the three rooms are running evaporator outlet line is freezing up, but after switching off two units its not. what do you this will be reason. Checked refrigerant charge is ok.

  • @jayvinmarqueses9484
    @jayvinmarqueses9484 11 месяцев назад

    Check first superheat, then you adjust accordingly.

  • @ChandanaPriyantha-pq3uv
    @ChandanaPriyantha-pq3uv 4 месяца назад

    Interesting lessons are there,I would like these trouble shooting of machineries,Thank you sir

  • @acong9891
    @acong9891 Год назад

    same trouble with my deep freeze.. but the trouble is happen in fish compartment.. are the solution is same like this video? hope u reply sir

  • @JayjayCaluyo
    @JayjayCaluyo Год назад +1

    big no sir,that valves is factory seated nothing to adjust check your control,fan blower and also refrigerant charge.

    • @leckyjake
      @leckyjake  Год назад

      and yet after doing it the unit becomes ok

    • @JayjayCaluyo
      @JayjayCaluyo Год назад +1

      Yeah but in few days you see

    • @leckyjake
      @leckyjake  Год назад

      that video was already from last year and the system still in good running condition up to now

  • @WALKINGJOURNEY-eq9zd
    @WALKINGJOURNEY-eq9zd Год назад

    Txv already set the company when you buy if thers have issue need to be replace..

  • @arturollanto3984
    @arturollanto3984 2 года назад

    I have a question what is the problem why have ice in met room and fish room

  • @jonnyjonnyyespapa8013
    @jonnyjonnyyespapa8013 Год назад

    Valve looks like there is a restriction. Also the type of frost build up on coil indicates lack of defrost and high humidity entering walk-in box

  • @somendranathchatterjee7704
    @somendranathchatterjee7704 2 года назад +1

    Nice video, well done buddy.

  • @dudungdkin2100
    @dudungdkin2100 2 месяца назад

    RIP leckyjake

  • @manuellastrollo2168
    @manuellastrollo2168 Год назад

    mabuti master hindi nasisira yung fan motor nyo pag binabasa nyo yung evaporator

  • @japhetjalandoni2751
    @japhetjalandoni2751 Год назад

    Hello sir Lecky ano po Kaya problem ng reefer Namin Hanggang _4.0 lang yaw tumaas high pressure nya ok Naman low pressure bagsak Ang pressure napansin ko yong expansion valve ay nag yeyo na ano po dapat. Echeck

  • @seanintia77
    @seanintia77 3 месяца назад

    rest and peace sir

  • @sukhwinder7636
    @sukhwinder7636 3 месяца назад

    Good evening bro

  • @elmerbiongan9784
    @elmerbiongan9784 2 года назад +1

    very informative video, thanks for sharing ideas on how to fix this kind of trouble on the reefer machine.

    • @leckyjake
      @leckyjake  2 года назад

      thank you for the support

  • @vishnuayapilla1791
    @vishnuayapilla1791 Год назад

    What to do with electronic expansion valve, sir can you please suggest me

  • @SreejeshKS-lw1iz
    @SreejeshKS-lw1iz 5 месяцев назад

    Your all videos are very useful.Please add more videos of reefer container issues

  • @rajeshsonkamble2552
    @rajeshsonkamble2552 Год назад

    Some reson ice frosting evaprater fan speed or not working

  • @WASIMEDOO
    @WASIMEDOO 6 месяцев назад

    So you increase the pressure on the txv is that right

  • @lunger2006
    @lunger2006 Год назад

    need a hot gas bypass for the vegetable room system

  • @MAJ-xy7qd
    @MAJ-xy7qd 2 года назад

    Sir leckyjake, how about meat room is in range,veg room is in range tapos fish room is in range after few days d na mameet ng fish room ang range ng temp sir panu po kaya un?thanks po

  • @manubkrishnan
    @manubkrishnan Год назад

    Thanks for the video... expecting more videos on refrigeration and AC...

  • @Timpon_Dorz
    @Timpon_Dorz 6 месяцев назад

    Very well made. Thank you... Explained a lot

  • @celsoguillepa8153
    @celsoguillepa8153 6 месяцев назад

    Sir Jake how to adjust thermostat meat room

  • @seamantv6182
    @seamantv6182 Год назад

    Very helpful to other sir idol

  • @gustavosh.5147
    @gustavosh.5147 2 года назад

    Sometimes ice on evaporator is also a sign of starving refrigerant.

  • @rajeshsonkamble2552
    @rajeshsonkamble2552 Год назад

    Air conditioner & refrigerator work Never ending to learn to new work

  • @robinkim143
    @robinkim143 Год назад

    i thought this vessel made at china hahaha

  • @claudiusderil7098
    @claudiusderil7098 Год назад

    Sir please explain about superheat please

  • @leroytheconvoy713
    @leroytheconvoy713 7 месяцев назад

    Nice video, thanks for posting!

  • @16valve64
    @16valve64 2 года назад +1

    Thanks a lot Jake

  • @alvinjayreyes7478
    @alvinjayreyes7478 Год назад

    sir can i get the diagram?

  • @pawan.malakar
    @pawan.malakar Год назад

    Very good knowledge form video.

  • @danielfdo4889
    @danielfdo4889 2 года назад +1

    Very useful 👍

    • @leckyjake
      @leckyjake  2 года назад

      thank you for watching

  • @taanhquan3665
    @taanhquan3665 Год назад

    Sao nhìn anh giống người Việt thế

  • @majidrad7516
    @majidrad7516 9 месяцев назад

    Thank you and good luck buddy 👍

  • @daludadoernelito
    @daludadoernelito Год назад

    You have on line clases ?

  • @hvacknowledgechannel1621
    @hvacknowledgechannel1621 5 месяцев назад

    Good explanation

  • @francisg3349
    @francisg3349 2 года назад

    Hi. What might be the cause of ice formation on the suction filter line of provision refrigeration compressor?

    • @smyejhamza
      @smyejhamza 2 года назад

      If its after the filter ( the side that goes in the compressor suction port ) that means you've got a clogged suction filter, and maybe you are flooding back the compressor but maybe not, only superheat could tell you if you've evaporated all of the refrigerant or if there is still some trapped in liquid state

  • @jeggercalihat1994
    @jeggercalihat1994 6 месяцев назад

    Solid idol 👍 dami ko na natutunan kahit d pa ako nakapag barko 😁

  • @formanworkshop2433
    @formanworkshop2433 11 месяцев назад

    How are you bro? Where you from

  • @svyat8710
    @svyat8710 2 года назад

    I liked this Video 👍👍👍💯

  • @globalgate8480
    @globalgate8480 Год назад

    Very nice, enjoy your posts

  • @Budiono-yk8dw
    @Budiono-yk8dw 5 месяцев назад

    Terima kasih sudah berbagi pengetahuan & pengalaman anda dalam bekerja,,video anda sangatlah bagus dan sangat penuh dengan ilmu pengetahuan.

  • @wasimedoo7994
    @wasimedoo7994 2 года назад

    Very good information nice job

  • @paologringoescalante6916
    @paologringoescalante6916 Год назад

    Thank you, leck!😊

  • @arabarmwrestlingtv1693
    @arabarmwrestlingtv1693 2 года назад

    thank you sir for all of this informations, i'm studying mechanical eng and i hope you can suggest some hvac books to learn more about fixing problems in hvac sys . thank u again .

  • @SupremeRuleroftheWorld
    @SupremeRuleroftheWorld 2 года назад +3

    why not use a constant pressure valve to hold a fixed temperature? with that you can hold a exact temperature just above 0 without any chance of freezing. its the standard for flower storage for example.

    • @leckyjake
      @leckyjake  2 года назад +1

      this is actually a vessel provision plant and changing the design requires approval from the class

    • @SupremeRuleroftheWorld
      @SupremeRuleroftheWorld 2 года назад +1

      @@leckyjake yes, i understand that. i just wonder why they didnt use such a valve. is it just for parts commonality or just a engineer that assumes everything always works perfectly all the time?

    • @leckyjake
      @leckyjake  2 года назад +2

      The temperature for the rooms should be variable, from negative 22 degrees Celsius to positive 22 deg Celsius. In this way they can use for various reasons.

  • @dennisvirtuoso6478
    @dennisvirtuoso6478 Год назад

    Tnx sa info sir..dagdag kaalaman

  • @johncoyote9012
    @johncoyote9012 2 года назад

    Nice info and kudos to u amigo. Keep safe always.