Bad txv symptoms | expansion valve ko kaise check kare | hvac training videos | हिन्दी اردو

Поделиться
HTML-код
  • Опубликовано: 17 ноя 2024

Комментарии • 57

  • @Salmanhvacsystem
    @Salmanhvacsystem 4 месяца назад +2

    Hamesha ki tarh 👌👌 maa shaa ALLAH ALLAH or kamiyabi de apko

  • @aishakhan8623
    @aishakhan8623 3 месяца назад +1

    Sir masha allah aap buhut acche se samjhate ho

  • @AhmedAhmed-lz1ke
    @AhmedAhmed-lz1ke 3 месяца назад

    Aoa
    Very knowledgeable Explanation Thanks

  • @mkaleem9824
    @mkaleem9824 6 месяцев назад +1

    You are the best in our technician group

  • @acmagd771
    @acmagd771 3 месяца назад

    Very clearly explained

  • @satyendrachauhan8534
    @satyendrachauhan8534 2 месяца назад

    Very nice superb thanks love you

  • @HamzaMalik-x8o
    @HamzaMalik-x8o 6 месяцев назад

    Thanks achhe se samchhaya h

  • @rudalchauhan7000
    @rudalchauhan7000 3 месяца назад

    Very nice

  • @altafhossain1574
    @altafhossain1574 3 месяца назад +1

    Thank you 🙏

  • @ShahalamKwt-k4h
    @ShahalamKwt-k4h 2 месяца назад

    good job

  • @SaleemKhan-es1ru
    @SaleemKhan-es1ru 6 месяцев назад

    Thanks bade Bhai

  • @khurseedkhanvlogsofficial
    @khurseedkhanvlogsofficial 6 месяцев назад

    Nice video bro

  • @bachpankakhel.648
    @bachpankakhel.648 6 месяцев назад

    Thank you for everything help and support brother.❤

  • @lailamajnu199
    @lailamajnu199 5 месяцев назад

    Yes, good job 👏 👍

  • @technicianmulajim7020
    @technicianmulajim7020 3 месяца назад

    Thanks you 👍

  • @sattarkhanjee7103
    @sattarkhanjee7103 6 месяцев назад

    Thanks for your sir ❤❤

  • @nomanqureshi340
    @nomanqureshi340 2 месяца назад

    Bhai ap nai condenser u bands kis cheez say coaded kia howa hai

  • @SaleemKhan-es1ru
    @SaleemKhan-es1ru 6 месяцев назад

    Assalamualaikum Bhai. Sir g unit freezing ka connection aur uski checking ke bare ek basic se video upload kariye

  • @nafizislam7424
    @nafizislam7424 27 дней назад

  • @raheeztp3158
    @raheeztp3158 6 месяцев назад

    👍👍👍👍

  • @SaleemKhan-es1ru
    @SaleemKhan-es1ru 6 месяцев назад +1

    Evaporator coil pe laga hota hai jaise LP HP jaisa hota shayad suko anti freezing switch bolte hai Bhai

    • @thetechhvac
      @thetechhvac  6 месяцев назад

      ji han ...✅

    • @jollyscaria1922
      @jollyscaria1922 4 месяца назад

      Expasion valve chockup ok lecking not working flusin and topset replcinv mechionsreolasinv gas cherging tocoveremoveing pin adjusting full fluhingsystom systom fuldion and norm fitef ok chocup rrplcing methad snd los didd high sidd e expshion topset removring ned replcing solveing porbels and unbalcing fixed ok systom poperly fixed ok systom vacuomed and systom gaumd vacum pump revalve coldd 2sidd vacom off and cherging lind fixid ok has cherging purging and methas pesged 35 mored ok iquked cherv 50t0 60cherging amper checking ok

    • @tanzilsahjad567
      @tanzilsahjad567 2 месяца назад

      Bro Rheem duct ac 2. 5 ton the issue is suction pressure show 200 and discharge 450 r410 unit but no cooling why

    • @SaleemKhan-es1ru
      @SaleemKhan-es1ru 2 месяца назад

      @@jollyscaria1922 sir g Hindi me Bhi baat kar lijye taki ham bignar ko bhi pata chale ki kis topic pe baat ho rahi hai please 🙏🙏

    • @SaleemKhan-es1ru
      @SaleemKhan-es1ru 2 месяца назад

      @@thetechhvac sir g Hindi me Bhi baat kar lijiye taki ham bignar ko bhi pata chale ki kis topic pe baat ho rahi hai please sir

  • @mahamdulhasan6892
    @mahamdulhasan6892 4 месяца назад

    Package Ac kah Honeywell thermostat Kece Automatic Kece Hoti hae oskah Display meh Automatic sensor kider lagta hae
    Or Honeywell thermostat kider lagnah chaiyee os barmeh ake details practical video upload kare brother ❤

    • @thetechhvac
      @thetechhvac  4 месяца назад

      Insha Allah brother 🤝 ✅ ⏰

  • @Technician613
    @Technician613 3 месяца назад

    sir ek 9 tr ki unit hai voltas ki jo aapne wo sab kuch ok hai par awaaj karte hai bhut jyada or firr trip ho jata hai 20second bad plzz reply

    • @thetechhvac
      @thetechhvac  3 месяца назад

      discharge pressure aur amps kitna hai?

  • @tanveerkhan3477
    @tanveerkhan3477 4 месяца назад

    Zamil 6.5 ton package unit hai evaporator with expension an dryer an compressor allchang but ritrun not coming compressor over hit hoke tip kar Raha hai keya rission ho Sakta hai

    • @thetechhvac
      @thetechhvac  4 месяца назад

      kuchh main aapko step bata raha hoon jisko aap follow karke apni problem solve sakte hain . lekin sab se pahle condensor ki kya condition hain jyada weak to nahi hai ( damage ) . agar ok hai to condensor coil proper neet and clean hai ? .
      follow this step 👉 sabse pahle aap compressor aur dryer filter lagane se pahle system ko flush / clean kar len ( R 11 ya R141 with nitrogen ) condensor coil ko alag se aur evaporator ko alag se .
      ab dryer filter aur compressor ko fit kar len . compressor agar aap naya use kar rahe hain to koi baat nahi lekin agar aap used compressor laga rahe hain to aap usko achhe se check kar len jaise kitna pressure hai , amps kitna le raha hai , sound kaisa hai kahin koi noise to nahi hai jisse hame maloom chalta hai ki mechenical ki kya condition hai , fir oil check kar len . ab iske baad system ko 500 micron vaccum karke gas charge karen . yaad rahe gas quality bhi matter karti hai cooling ko effect karne ke liye . to hamesha achhi quality ki gas use karen . ummeed karta hoon aapke sawal ka jawab mil gaya hoga 💚

  • @muhammadnaveed9382
    @muhammadnaveed9382 4 месяца назад

    Back pressure 90 low hy or Head pressure 270 bhi low hy gas R410 charge krta hon to wo bhi charge nhi hoti kia reason ho sakti hy please guide me

  • @ranadastgir3690
    @ranadastgir3690 6 месяцев назад

    Please explain one video thanks
    Lp HP switch close and open katny pressure pay hota han R22 R 410 and R134a R32

    • @thetechhvac
      @thetechhvac  6 месяцев назад

      watch this video 👉ruclips.net/video/UpkM4KWSfAo/видео.html

  • @mohammadesamuddin3912
    @mohammadesamuddin3912 4 месяца назад

    Aslm bhai AK prablam Ara back pressure barabar Ara pirbi cooling nai Ara section pipe het hura prablam kya hai

  • @SyedSher313
    @SyedSher313 6 месяцев назад

    Bhai Heat Pump hai usme 4 way reversing valve laga hua hai...Heating mode mein suction aur discharge pressure normal running karta hain but cooling mode me dalne se suction pressure pura down hojata hai approx 20PSI aur filter drier bhi bahut thanda hota hai aur cooling mode bhi show nahi karta hai display mein.

    • @thetechhvac
      @thetechhvac  6 месяцев назад

      agar cooling mode par chalane se dryer filter thanda hota hai to aapka filter chock hoga . filter normal ya thoda sa heat hona chahiye ye good condition hai aur thanda hai to iska matlab filter chock kar raha hai ( filter change karna padega )
      NOTE ;- kabhi kabhi reversing valve agar problrm karta hai to bhi aisa problem aa sakta hai

  • @RoshanDcunha-wu1ni
    @RoshanDcunha-wu1ni Месяц назад

    valve expation oint leakage

  • @dariwalaladka
    @dariwalaladka 4 месяца назад

    Bhai agar expansion valve kharab hai aur usko main remove karke direct kardu to kya cooling me koi effect pare ga ??

    • @thetechhvac
      @thetechhvac  4 месяца назад +2

      ji han bagair expansion valve ya capillery cooling nahi hogi ( expansion valve ya capillery high pressure liquid ko low pressure liquid main convert karti hai jisse system main cooling hoti hai aur agar expansion valve remove karke direct kar denge to high pressure liquid , low pressure liquid main convert nahi hoga aur jisse cooling bhi nahi hogi . aur agar aasan way main samjhane ki koshish karoon to itna yaad rakhho ki jitna gas ka pressure kam hoga utna hi temp. gas ka kam hoga to jab tak kam pressure nahi karenge tab tak gas thandhi nahi hogi ... ummeed karta hoon aapko samajh main aa gaya hoga 🤝

    • @dariwalaladka
      @dariwalaladka 4 месяца назад

      @@thetechhvac main yeh kehna charaha hu ke distributor aur capillery tube rahega sirf expansion valve ko remove kardu to kya koi problem hoga

    • @thetechhvac
      @thetechhvac  4 месяца назад +2

      ji han problem hogi ! ( distributor aur capillery tube jisko aap rakhne ko bol rahe ho wo gas ke flow ko sirf distribute karegi na ki high pressure liquid ko low pressure liquid main convert karegi . jo distributor ke sath capillery tube lagi hai wo as distributor ka kaam karti hai na ki capillery )

    • @dariwalaladka
      @dariwalaladka 4 месяца назад

      @@thetechhvac thanks bhaiya ❤️

    • @israrahmad2756
      @israrahmad2756 2 месяца назад

      Dierect kren ge to cooling n ho gi

  • @rajjakali4178
    @rajjakali4178 3 месяца назад

    Bhai compressor 30 minutes chalne k bad back pressure badh jata hein wor thanda hona band kar deta hein, scroll compressor 10 tr ka hein. Kya ho jakta hein?

    • @RaviKumar-gz2tg
      @RaviKumar-gz2tg 2 месяца назад

      Hall Bhai hamar sat bhi asa hi ho rahi hai kiya kare ame bhi bthana

  • @Technician613
    @Technician613 3 месяца назад

    sir ji high pressure 500 pe chala jata hai on hote hi or low pressure 60 pe rahta or fir ekdum band ho.jata hai

    • @thetechhvac
      @thetechhvac  3 месяца назад

      system main chocking to nahi hai ❓

    • @strangergameing3771
      @strangergameing3771 2 месяца назад

      Bhai aapka koun sa refrigant use kar rahe ho wo bhi bata do

  • @bikashtamang5158
    @bikashtamang5158 4 месяца назад

    भाई अापका अावाज सहि नहि अाराहा है समझ मे नहि अाया।