kyonki iska kaam low pressure hone par compressor ko band karana hota hai na ki high pressure par high pressure ka kam HP ( high pressure switch ) ka hota hai aur aise hi dono ( HP , LP ) mil kar compressor ko low aur high pressure se compressor ko protect karate rahte hain . aur ye kuchh aise design hote hain ki jaise LP switch ka pressure jyada hoga to contect point ( internally LP switch ) judega ( lekin yaad rahe ye har ek refrigerant ke alag alag pressure ke according aate hain ) aur HP ka pressure jyada hone par contect point tootega … Ummeed karta hoon aapke sawal ka jawab mil gaya hoga 🤝💚
meter se check karne par jin do wire par reading with sound bata raha hoga us ko use kar len baki bachi ek wire rahne den ( one point common hoga baki bachi wire NO , NC ) isma main bhi two type ke aate hain non pcb , and pcb wale abi jo maine bataya hai ye none pcb wale ki baat ki hai..
AP mere favorite technishtion hea mein apsy bht inspire hu apka andaz bht acha lgata haii smjhany ka I love u sir
❤Very good and clear teaching,🌷thahk you sir,🌷🇧🇩 🇧🇩. 🇧🇩 🇧🇩,
You are most welcome
Masaallah sir❤❤❤❤❤❤
Very good information 🙏🙏
Electronics expension valve ke uper practical video banaye please aapka tarika sahi hai wait
Thank you bhai jaan
Hp ka apne nhi test kiye working sir
MAsha Allah amazing and informative video.May Allah Pak bless upon you.
Thanks for liking💚
Thank you sir good information 👍👍
Nice information sir
Sir pcb par wala video bataye thoda
Sukriya Faiz bhai.. great job 👍
welcome 🤝
Good man nice information A to z
Happy to help 💚
Assalamualaikum❤
Mein 30 sal sy is kam sy related hu but esy mere ustad NY b nhi smjhaya jesy apne smjhaya hai mujhy
Nice information
So nice of you💚
Good
Thanks vai ❤❤❤❤❤❤❤🇧🇩🇧🇩
welcome 💚💚💚❤️❤️❤️🇮🇳
Good luck
Good job brother.
Thanks💚
Thank u bhai good job
Thank you for your information.
My pleasure 😍
Faz bhai Aslawalekum aap kaa bahot bahot sukriya samjhane kaa aap number chahiye kabhi kaam me koi muskil me rahu to aap se baat karne ke liye
Nice❤
Thanks 👍 brother
Welcome😍
Kya LP HP switch change karne ke liye gas pump down karna chahiye please reply
Next vedio bhai.. 24 transformer se nikl kr kaise kaise jare hai pls thodi details..
ok ✅
Thik bhai
Cute off pressure details par video banay
R22, R134a R 32 R 410A
We will try
Bhai HP /LP 24V pr chalta tha kya mai isko 220 pr Chala skate hai
bilkul chala sakte hain 24 volt par aur 220 par
Sir aap kahan kaam karte ho
Low pressure per kat marke band ho jata h bt High per chal jata h eska kya problem ho sakta h
kyonki iska kaam low pressure hone par compressor ko band karana hota hai na ki high pressure par high pressure ka kam HP ( high pressure switch ) ka hota hai aur aise hi dono ( HP , LP ) mil kar compressor ko low aur high pressure se compressor ko protect karate rahte hain . aur ye kuchh aise design hote hain ki jaise LP switch ka pressure jyada hoga to contect point ( internally LP switch ) judega ( lekin yaad rahe ye har ek refrigerant ke alag alag pressure ke according aate hain ) aur HP ka pressure jyada hone par contect point tootega … Ummeed karta hoon aapke sawal ka jawab mil gaya hoga 🤝💚
Assalamualaikum किसी किसी में 3 वायर भी होता है इसका क्या मतलब है।
waalaikumassalam 🤝💚 ...
as feedback ke liye ( NO , NC , point )
कैसे समझ में आयेगा की ये No है या nc
मान लीजिए ये किसी चिल्लर में लगा है और 3 वायर है तो क्या एक हटा सकते है प्वाइंट वाला
meter se check karne par jin do wire par reading with sound bata raha hoga us ko use kar len baki bachi ek wire rahne den ( one point common hoga baki bachi wire NO , NC ) isma main bhi two type ke aate hain non pcb , and pcb wale abi jo maine bataya hai ye none pcb wale ki baat ki hai..
AP muslim hea ye btadan
🤝🤲😍
AP mere favorite technishtion hea mein apsy bht inspire hu apka andaz bht acha lgata haii smjhany ka I love u sir
love you toooo brother 💚😍
Nice information
So nice of you😍
Nice information
Thanks🤝😍