Thermostatic Expansion Valve || TXV adjustment || TXV faults

Поделиться
HTML-код
  • Опубликовано: 1 янв 2025

Комментарии •

  • @abuatikahfauzi7533
    @abuatikahfauzi7533 4 месяца назад +3

    Thanks for your sharing....👍👍👍

  • @Hvactechnicalmaster
    @Hvactechnicalmaster 4 месяца назад +2

    Very informative video

    • @FKmechofficial
      @FKmechofficial  4 месяца назад +2

      @@Hvactechnicalmaster thanks Dear brother ❤️

  • @Lucky-kc6sc
    @Lucky-kc6sc 5 месяцев назад +2

    Nice Information ❤🎉

  • @nayanjagirdar8408
    @nayanjagirdar8408 6 месяцев назад +2

    Nice sir👌👍

  • @ImranTech-hx4fu
    @ImranTech-hx4fu Год назад +2

    Waw great video Sir

  • @narayanchaudhary3580
    @narayanchaudhary3580 Год назад +1

    Sir apke sare video bahot hi jankari purn hai age bhi aise hi video banate rahe ❤ 👍

    • @FKmechofficial
      @FKmechofficial  Год назад +1

      Thanks Dear brother for your valuable comments 👍

  • @azmathussain8232
    @azmathussain8232 Год назад +1

    Aoa farman bahi bht achi video ha mashallah

  • @tazimshaik8085
    @tazimshaik8085 5 месяцев назад +1

    Masallah masallah kya baat h aap ki aap ka samjane bhot badya h Allah hafiz

  • @AliKhan-jc8dy
    @AliKhan-jc8dy Год назад +2

    Very well explained

  • @HarisAhmad-zw3pi
    @HarisAhmad-zw3pi Год назад +2

    Very nice teacher

  • @kainTV
    @kainTV 8 месяцев назад +3

    valuable information

  • @IshfaqKhann
    @IshfaqKhann 8 месяцев назад +2

    Excellent sir

  • @mohammadmaroof7867
    @mohammadmaroof7867 Год назад +1

    Bahot he badhiya bhaya❤

    • @FKmechofficial
      @FKmechofficial  Год назад

      Thanks Dear Sir for your valuable comments ❤️

  • @rizwanshafi8509
    @rizwanshafi8509 9 месяцев назад +1

    Great great explanation.

    • @FKmechofficial
      @FKmechofficial  9 месяцев назад

      Thanks Dear brother for your valuable comments ❤️

  • @harimanda9412
    @harimanda9412 10 месяцев назад +2

    Thanks sir 😊

  • @jahangiralam-qr9px
    @jahangiralam-qr9px 10 месяцев назад +1

    Good experts.

    • @FKmechofficial
      @FKmechofficial  10 месяцев назад

      Thanks Dear brother ❤️

    • @jahangiralam-qr9px
      @jahangiralam-qr9px 10 месяцев назад +1

      Boss your City? I am from Chittagong, Bangladesh.

    • @FKmechofficial
      @FKmechofficial  10 месяцев назад

      @@jahangiralam-qr9px thanks Dear brother from Bangladesh,,,
      I am from Pakistan

  • @enjoylife5138
    @enjoylife5138 Месяц назад

    Thanks 👍

  • @Hasanali-kd3iv
    @Hasanali-kd3iv 10 месяцев назад +2

    Very nice nice

  • @prakashgotame8875
    @prakashgotame8875 3 месяца назад +1

    Sir txv ka clockwise and counterclockwise ghumane per discharge pressure and subcool temp me kya kya hoga cooling load increase karna kiya evaporator inlet temp kitna range ma rakhe sir

    • @FKmechofficial
      @FKmechofficial  2 месяца назад

      Brother, cooling load maintain Karne kelie hr refrigerant ke pressure ranges different hote hain

    • @prakashgotame8875
      @prakashgotame8875 2 месяца назад

      + temp wale me evapotor me temp maintain karne k liya txv output temp kitna set kiya sir

  • @pramodpoojari4314
    @pramodpoojari4314 8 месяцев назад +1

    Sir Walkin chiller ka same ex value new replaced kiya fir bi ex value ka out let me icing horaha hai kya reason hai gas pressure pura sahi hai

    • @FKmechofficial
      @FKmechofficial  8 месяцев назад

      Refrigerant kam ho sakta hai,
      Refrigerant ka pressure km adjustment ki waja se,
      Super heat adjustment problem

  • @azmatullah7164
    @azmatullah7164 Год назад +1

    Nice

  • @ibrahimohammad1398
    @ibrahimohammad1398 3 месяца назад +1

    Goodsar

  • @mumraizakhtar3994
    @mumraizakhtar3994 Год назад +1

    جزاكَ اللّٰه‎

  • @shaikhaejazali4774
    @shaikhaejazali4774 2 месяца назад

    wow 😮

  • @AHK702
    @AHK702 Год назад +1

    Sir agar 5ton ke package ac me txv installation karna ho to capillary ka size aur length kitna hona chahiye

    • @FKmechofficial
      @FKmechofficial  Год назад

      Thanks Dear brother for your valuable comments,
      TXV to koyi bi ho bs evaporating temp: ki range se dekhi jati hai awr lagayi jati hai,
      But capillary tube ka taluq mass flow se hai, Ap 0.059 ki capillary tube 24 inch two capillary tubes laga sakte hain...

    • @majharulislam5950
      @majharulislam5950 Год назад

      From Adjusting screw gas is leaking after opening the cap. Is that normal or have some problem.

  • @Divyanshiuikey
    @Divyanshiuikey Год назад +1

    Sir ji Danfoss TEX 55 (R22)ke exponsal valve k bare me bataye

  • @ammarmaqsood1493
    @ammarmaqsood1493 9 месяцев назад +1

    Refrigerant flow barhany se tou cooling increase aur temp kam hona chahye. Idher ulta kese ho rha plz explain

    • @FKmechofficial
      @FKmechofficial  9 месяцев назад

      Brother 1 khas limit tk flow barhany se cooling increase hoga awr temp: decrease hoga, but hr unit me limit different hota hai.
      Uss khas limit me flow barhany ka matlab evaporator me more refrigerant maujood hota hai, awr more BTUs absorb honge.
      Agar ap flow bahut zyada barhayenge Jo ke evaporator design se zyada hoga to usss surat me evaporator me temp: halka sa barhega jis ka matlab cooling km hota Jayega .

    • @ammarmaqsood1493
      @ammarmaqsood1493 9 месяцев назад +1

      @@FKmechofficial thank u so much sir. Kya iss ka koi reference material hai koi book etc

    • @FKmechofficial
      @FKmechofficial  9 месяцев назад

      @@ammarmaqsood1493 Exactly apko Google se mil sakte hai Bhai,
      Engineer levels ke bhi awr students levels ke bhi

  • @ammarmaqsood1493
    @ammarmaqsood1493 9 месяцев назад +1

    Salam. Sir ye jou temp ap ny consider kiye ye refrigerant k thy ya air k thy jisko cool kerna tha ?

    • @FKmechofficial
      @FKmechofficial  9 месяцев назад

      Brother temp: refrigerant ka hai but ye directly air ko bhi effect karega

  • @dirajgotame
    @dirajgotame Год назад +1

    Sir expansion valve ya filter block hoga tyo discharge pressure ghatega ya badga amp me Kay hota ya

    • @FKmechofficial
      @FKmechofficial  Год назад

      Dear brother Discharge pressure Tora SA barega...awr suction pressure me kafi Kami ayegi...

    • @dirajgotame
      @dirajgotame Год назад +1

      Amp sir

    • @FKmechofficial
      @FKmechofficial  Год назад

      @@dirajgotame agar compressor rotary hai pir ampr badenge...awr agar compressor piston wala hai to pir ampr drop honge

    • @zuone3573
      @zuone3573 Год назад +1

      ​@@FKmechofficial
      Sir wih kiuyon?
      Amp tou increase hi hon gay as compressor has to work hard now

    • @FKmechofficial
      @FKmechofficial  Год назад

      @@zuone3573 yes but suction pressure agar low ho jaye, to compressor hard work kaise kr Sakta hai, matlab suction line se flow me kami ho jayegi

  • @prakashgotame8875
    @prakashgotame8875 Год назад +1

    Thank u so much sir sir good expension valve me expension valve se output me ice formation hoga ki naiii hoga sir example k liya chiller cold storage refrigeration system me use expension valve me

    • @FKmechofficial
      @FKmechofficial  Год назад

      Ye depend karta hai refrigerant ke pressure pr...
      Agar refrigerant Ka pressure TXV se Aage Yani evaporator me ap zyada rakte hain to only NAMI hogi...but agar evaporator pressure ap km rakte hain to TXV se Aage ice hoga

    • @prakashgotame8875
      @prakashgotame8875 Год назад

      Cold storage minus 12 centrigrade me ice aarahe good he sir

    • @prakashgotame8875
      @prakashgotame8875 Год назад +1

      Sir 0 degree centrigrade Upper temp example 3 degree me expension me ice aayaga tyo bad he

    • @FKmechofficial
      @FKmechofficial  Год назад

      @@prakashgotame8875 temp below 0⁰C ki surat me ice ayega...
      Agar evaporator coil ki temp 0 se zyada Hoga to ice nhi balke only nami ayigi

    • @prakashgotame8875
      @prakashgotame8875 Год назад +1

      OK sir

  • @ITR30
    @ITR30 Месяц назад +1

    Sir coldroom ke evaporator ke upar on karte hi thode der me ice araha hai kuch upay bataye please

    • @FKmechofficial
      @FKmechofficial  Месяц назад

      Check the Expansion valve brother,
      I'm sorry for replying late

  • @felixruvinga7232
    @felixruvinga7232 Год назад +2

    May you please add subtitles so that students from Africa will understand way better🙏🏿🙏🏿🙏🏿🙏🏿

    • @FKmechofficial
      @FKmechofficial  Год назад +1

      Thanks Dear for connecting with us...
      The subtitles are included in video 🙏

  • @sudhanshupriyadarshi1370
    @sudhanshupriyadarshi1370 6 месяцев назад +1

    Sir agar valve ki setting bigar jaye to wapas usko set kaise kre? 404 refrigerant use krta hu 5 ton semi hermatic compressor h

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад +1

      Sorry brother for late reply,
      Agar bellows adjustment karna ho to suction pr gauge laga kr screw ko tight awr loose kiya jata hai, JB suction normal ho jaye i-e 20 se 25 Psig ho Jaye to adjustment complete hogi.
      Agar superheat adjustment me issue to phir suction line pr sensing bulb ko Aage peeche Le Jaye to suction pressure gauge pr khud bakhud ho jayi

  • @IshfaqKhann
    @IshfaqKhann 8 месяцев назад +1

    Sir valve k adjustment se room temperature pe aser ho ga k ni plz rply

    • @FKmechofficial
      @FKmechofficial  8 месяцев назад +1

      Yes, zaror hota asar kyunke TXV adjustment cooling coil me flow barane ya kam karne pr hota hai

    • @IshfaqKhann
      @IshfaqKhann 8 месяцев назад +1

      @@FKmechofficial sir central Africa se hn mere pas frozen refer container ha jis ka temperature -20⁰ tak jhata ha Kuch dino se temperature kafi decrease ho rha ha hr cheze ok ha ager valve ko adjusting kr dun TU kitni degree farq pare ga,6 ton ki unit ha plz rply

    • @FKmechofficial
      @FKmechofficial  8 месяцев назад +1

      @@IshfaqKhann Dear, konsa temp: decrease ho raha hai ?
      Ambient ya evaporator coil temp: ?

    • @IshfaqKhann
      @IshfaqKhann 8 месяцев назад +1

      @@FKmechofficial room temperature

    • @FKmechofficial
      @FKmechofficial  8 месяцев назад +1

      @@IshfaqKhann adjustment se tora bahut faraq ho sakta hai. Taqreeban 4 to 5 degrees.
      Ap Pakistan se ho ya India se ?

  • @ansarahmed1021
    @ansarahmed1021 Год назад +1

    اس میں گیس کتنے کلو ہے جو اپ کا انتظار رہے گا

  • @sulemanshaikh4798
    @sulemanshaikh4798 Год назад +1

    Assalamualikum
    Mera mins 11 ka chiller hi lekin wo sat nahi ho raha hi plz help

  • @amirhussain6849
    @amirhussain6849 Год назад

    Nic

  • @mohammedfarooqueshaikhirfa467
    @mohammedfarooqueshaikhirfa467 Год назад +1

    If sensor bellow is break then what happen

  • @IshtiyaqKhan-hs5nm
    @IshtiyaqKhan-hs5nm Год назад +1

    ❤❤❤❤❤

  • @baldevbhambhariya1061
    @baldevbhambhariya1061 Год назад +1

    Orifice kitna number he

    • @FKmechofficial
      @FKmechofficial  Год назад

      Brother TXV ke orifice Ke number Ka Kiya matlab hai,
      Me ne to Kabhi TXV orifice ke number Ka Kabhi nhi suna hai...

    • @baldevbhambhariya1061
      @baldevbhambhariya1061 Год назад +1

      Accha bro exprion valve bole to shop vala bolega ki kitne number TXV valve

    • @baldevbhambhariya1061
      @baldevbhambhariya1061 Год назад

      Krupya Aapka number bhejiye bro

    • @baldevbhambhariya1061
      @baldevbhambhariya1061 Год назад

      To humko bolna pdega na big bro ki 0 number ki orifice 1 number orifice 2 number orific 3 number orifice

    • @FKmechofficial
      @FKmechofficial  Год назад +1

      @@baldevbhambhariya1061 brother ye to TOR ke hisab se milti hai,,
      Ton of refrigeration ke hisab se

  • @sulemanshaikh4798
    @sulemanshaikh4798 Год назад +1

    Compressor R404 ka hi

  • @MIJANURRAHMAN-xr2ew
    @MIJANURRAHMAN-xr2ew 3 месяца назад

    Sir,When I reduce the refrigerant with txv, more gas will accumulate in the condenser, will not it increase the pressure on the compressor?

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@MIJANURRAHMAN-xr2ew yes it increase burden on compressor if so much pressure accumulate in condenser