HOW DO THEY DO... HOW TO DO FUEL OIL CHANGEOVER FOR EMISSION CONTROL AREA ONBOARD SHIP..
HTML-код
- Опубликовано: 27 янв 2025
- ECA FUEL# VLSFO#FUEL CHANGE OVER# SECA #FOBAS#FOBAS CALCULATOR# HOW TO DO CHANGEOVER OF FUEL OIL IN ECA AREA# EMISSION CONTROL AREA#SULPHUR EMISSION CONTROLLED AREA
highly appreciate ur work sir
u r an epitome of marine engg knowledge
Thanks for your good compliment sir... Jst sharing watever i kno
Good explanation ...chief ✨
Glad you liked it!
Thank you for different videos
Welcun sir
Hi dear, very nice and useful vedio, keep it up, consider about background sounds
Hi dear...thanks for your good comment....sure vl take care of sound
Thanks a lot sir
welcum sir ..pls keep supporting
Bda kindly let me know what is the formula to calculate fuel oil consumption at lower RPM .
Or its in seatrial report ....kindly reply.
Good Day kindly let me know where to find fuel oil consumption vs rpm data.
Or if one to calculate that on which rpm what is the fuel oil consumption is so how we can do this .
Nice video..just need voice clearity
I will try my best
I TRULY APPRECIATE YOUR EFFORTS THANKS SIR
I HAVE 1 QUESTION TO BE CLEAR ,WHEN CHANGING TO D,O COMPLETELY DO WE ALSO NEED TO CHANGE OVER RETURN LINE VALVE FROM HFO TO D.O RETURN LINE KINDLY CLARIFY
Yes you do
❤❤❤
😍
❤
Thank u...
Sir, pls make a video
how to adjust generator fuel pump timing?
will do for sure sir.. pls give some time
Please 🙏 make a video regarding AE’S adjustment. Fuel timing . Fuel rack .
sure will do ..please give some time
Cheif
Why we are reducing rpm?
You have mentioned fo temprature should not be less than 95 because purifier is running i didn't understand why purifier came in between?
At starting of change over you completely shut the fuel valves of hfo. About pobas calculator it have given timings ?
when we reduce the rpm fuel consumption will be reduced and load will be reduced for the engine to have gradual mixture of oil.
Service tank temperature will be the fuel oil outlet temperature from hfo purifier so the hfo temperature dont go less than purifier temperature.
at the beginning completley open the diesel inlet and close hfo inlet valve.
fobas calculator will give you how much time you need to change over from hfo to do completly in entire system.
@@marine-knowledge-basha thank you chief
sir , plz share noon report calculation and bunkering procedure.
Sir its already in our channel..
What about fuel oil return ? When to change that
fuel oil return in case if ur doing from hfo to do ....return line for hfo should kept open and once the fuel oil temperature come to diesel oil temp den u can open the do return and close hfo return,,,This is to avoid hfo gtng mixd with do .
Is there any diff. in procedure of Fo change over in system having mixing column and without mixing column?.
Secondly, as both hfo service tank and purifier have seperate heating system.so, why to consider purifier heater in this?.
Thank you in advance.
No sir
No need to consider purifier heater sir..
Thanks 🙏. Nice explanation very clearly. Could you please tell vice Versa procedure from mgo to Hfo.
1)
Is it necessary to heat up diesel oil little before opening HFO ?
2) Please explain it for boiler also . Boiler should run in manual mode always ? Continuously? What temperature I should keep on boiler ? Fuel always different !
3) As far as I know from my experience before change over it is best practice to clean all the filters and after change over too. Also one generator to be changed over with separate independent system (flushing pump) first . And keep it running for safety reason . Is it correct please 🙏 comment .
Thanks 🙏. Nice explanation very clearly. Could you please tell vice Versa procedure from mgo to Hfo.
1)
Is it necessary to heat up diesel oil little before opening HFO ? No need to heat up diesel oil
2) Please explain it for boiler also . Boiler should run in manual mode always ? No ,boiler should be in auto mode only
Continuously? What temperature I should keep on boiler ? depends on area u can use either vLSFO OR MDO
3) As far as I know from my experience before change over it is best practice to clean all the filters and after change over too. Also one generator to be changed over with separate independent system (flushing pump) first . And keep it running for safety reason . Is it correct ..
UR VERY CORRECT SIR
If FOBAS calculator is not there, is there any other way to find out or calculate how much time it will take for changeover?
FOBAS will be alwys available ...if not u have to take and refer previous oil consumption data for the vessel engine specified RPM from sea trial record and do the calculation for change over
@@marine-knowledge-basha okay thank you so much sir for responding.
What is your opinion when we make a change over from MGO TO HFO is it neccessery to heat up disel oil or not? A lot of people say that need to heat MGO up to 75- 80 deg to avoid termoshock of your pumps and system . Some engineers said never heat up disel it is dengerouse. Clirify it here please.
No need to heat up sir.. Absolutely no need to hear up LSMGO.. Thermal shock can be avoided by gradual mixing of LSMGO with HFO..
@@marine-knowledge-basha when we work on big tanker and make a change over procedure the boiler should work continuously and dump steam during change over ? Or not ?
Mama i am suhaila