Adding a fire alarm pull station Notifier NFS-320c home fire alarm system

Поделиться
HTML-код
  • Опубликовано: 10 сен 2024

Комментарии • 124

  • @ifixforu
    @ifixforu 10 месяцев назад +15

    4:25 “hue g rection” 💀 anyways amazing video as always

    • @Organham4903
      @Organham4903 10 месяцев назад

      Lmao glad I’m not the only one who saw it

    • @joeycaridi3030
      @joeycaridi3030 8 месяцев назад

      hue g rection
      My brain: huge reaction

    • @ifixforu
      @ifixforu 5 месяцев назад

      @USAUK2 yeah like kilometers or Celsius

  • @FourtyFiftyEighty
    @FourtyFiftyEighty 10 месяцев назад +5

    ngl that intro was amazing

  • @jo_bro666
    @jo_bro666 10 месяцев назад +8

    4:24 nice light switch

    • @Honekawasuneo646
      @Honekawasuneo646 4 месяца назад

      In Vietnam is call cầu dao khẩn cấp translate is call point

  • @IanGSully
    @IanGSully 3 дня назад

    Late comment I know. But this is an amazing video! That pull station is also in a good location too because let's say something in your dryer catches on fire. You can initiate the fire alarm immediately upon seeing it.

  • @thetoffeetable
    @thetoffeetable 10 месяцев назад +3

    Another excellent video. That second pull station is a good addition to your home system. Makes sense to have one near both main exits to your home. Good job!

  • @YourLocalFireAlarmTech
    @YourLocalFireAlarmTech 10 месяцев назад +4

    I love being able to learn about rough in from you dude, This will come in clutch for my own systems too, or if I need to do it myself in the field lol. Love the video as always man!

  • @owensanto4004K
    @owensanto4004K 10 месяцев назад +26

    “My house is on fire again” wait… again 😳

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +14

      Shit happens

    • @jo_bro666
      @jo_bro666 10 месяцев назад +1

      ​@@nics-systems-electric i happen

    • @ajsmusic723
      @ajsmusic723 10 месяцев назад +1

      ​@@nics-systems-electric true

    • @Huey-Gamer
      @Huey-Gamer 10 месяцев назад +1

      @@nics-systems-electricshit does happen

    • @Neptunesalad12
      @Neptunesalad12 7 месяцев назад +1

      ​@@nics-systems-electricshit happens all the damn time

  • @elektrokinesis4150
    @elektrokinesis4150 10 месяцев назад +9

    my mother would have the biggest bird if I put anything like this in her house :(

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +6

      We found it's much better to have the commercial system than the residential crap that sets off every day you could do it without the pull stations though absolutely

    • @SDPP992
      @SDPP992 10 месяцев назад

      I had one installed at my apartment complex when I had my ms-9600udls, had to utilize the basement access in the hall to get all the wiring done lol

  • @HenBasketFireAlarms
    @HenBasketFireAlarms 10 месяцев назад +1

    Nice video. I do agree that the 115 cm max height is low, that equates to about 45”, about 3” or 76 mm lower than the height down here in the states. Feels off being that low, even if it is only a few inches.

  • @leafmk
    @leafmk 10 месяцев назад +1

    You finally got another pull station! Great Nic.

  • @TheLastWolfBane
    @TheLastWolfBane 10 месяцев назад +2

    Nice vid and smart on where you you installed the pull station, i look forword to more content. Also where do you get your pull stations?

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +2

      Thanks! I get most the of my fire alarm equipment on eBay but this particular one came from a building.

  • @FireGuy1500
    @FireGuy1500 10 месяцев назад +1

    Dude the intro is awesome 😊

  • @NormanWeather
    @NormanWeather 10 месяцев назад +4

    What... what was that intro? Great job! 😂

  • @ResetTheFireAlarm
    @ResetTheFireAlarm 5 месяцев назад

    The intro was so funny😂, good job as always man!

  • @dutchwolf2675
    @dutchwolf2675 10 месяцев назад

    Great video! Good addition. Interesting name for the light switch next to it.

  • @calebmorand4604
    @calebmorand4604 10 месяцев назад +2

    I really like your home system! I am also doing a home alarm system in my house. I have 2 questions for you.
    1. I am installing conventional attic heat detectors. Will putting the end of line resistor in the Attic heat detector junction box be a problem? Will the extreme heat of the attic heat up the resistor and change the resistance of the resistor causing zone troubles?
    2. I'm using Honeywell Genesis FPL wire for the system. I'm pretty sure this is obvious, but will FPL wire survive longer in a direct Flame then regular wire? I'm asking because I've read that FPL resists the spread of Fire. I haven't read that it survives longer in direct heat or flames. Thank you for your help! You are doing a great job on your system. It's very impressive!

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +1

      The systems are meant to operate on a range of resistance within a certain parameter of the spec for that reason so that's fine. the insulation is just rated to be installed in a higher ambient temperature in an actual fire it's going to be extremely minimum as for any extra resistance it's going to provide against heat if you actually need wire to resist extreme temperature you use mineral insulated also known as pyrotenax cable

    • @calebmorand4604
      @calebmorand4604 10 месяцев назад

      @@nics-systems-electric Got it. thank you!

  • @collinrieck4939
    @collinrieck4939 10 месяцев назад +1

    You should add a door holder to the door at the bottom of the basement steps.

  • @joeycaridi3030
    @joeycaridi3030 7 месяцев назад

    05:29 Your Drywall cut-out tool sounds very musical 🎼 🎶

  • @theplanetmc181
    @theplanetmc181 10 месяцев назад +1

    I remember seeing this in another video, and I wondered why it was there, now I know!

  • @SodiumInduction-hv
    @SodiumInduction-hv 10 месяцев назад +2

    Wow!

  • @kyleviolette8808
    @kyleviolette8808 10 месяцев назад +1

    You should do a durability test on system sensor, p2rl

  • @adventuresquadofficial
    @adventuresquadofficial 3 месяца назад

    Next, you should add a pull station near the sliding door

  • @UKsystems
    @UKsystems 10 месяцев назад +1

    I like how the start is edited differently

  • @AmityOhCramity98
    @AmityOhCramity98 10 месяцев назад +1

    5:28 I thought you were about to play us a song on the hackzall lol

  • @unbiasedventures2091
    @unbiasedventures2091 7 месяцев назад

    One of the best videos out there on this stuff. Question, so is the only way to create a new point through auto program on this panel? I never saw a “add point” option and don’t have the software any more. Working on a 180 point Notifier 640-2 with 2 SLC loops and wanted to make sure I didn’t lose any previously programmed points doing this. Its been a few years. Thanks!

    • @nics-systems-electric
      @nics-systems-electric  7 месяцев назад +1

      Yes the Onyx series only has auto program as an option to add a point for front panel programming there's no way to manually add a point.

  • @EASsirenVids01
    @EASsirenVids01 10 месяцев назад +2

    Noticed that pull station in your last testing video but I didn’t mention it I didn’t wanna spill the beans for whoever didn’t notice it lol

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +1

      Everyone else that noticed did spill it lol

    • @EASsirenVids01
      @EASsirenVids01 10 месяцев назад

      @@nics-systems-electric lol

    • @CGray1234
      @CGray1234 10 месяцев назад

      @@nics-systems-electricguilty lol

  • @unbiasedventures2091
    @unbiasedventures2091 7 месяцев назад

    If you connect a device to the SLC with an unused address, or delete one that is still connected with a unique address, will the panel, eventually show, “unspecified device“ or “extra point?”

    • @nics-systems-electric
      @nics-systems-electric  7 месяцев назад +1

      No it will not indicate if there are devices that are not programmed in

  • @leafmk
    @leafmk 10 месяцев назад +1

    Dog be chillin 2:31

  • @rodgodx345
    @rodgodx345 10 месяцев назад

    2:26 this backdoor looks like a nice spot to put another pull station.

  • @thecomputergeek101old
    @thecomputergeek101old 10 месяцев назад +2

    That face at 6:43

  • @tnejgardening2084
    @tnejgardening2084 10 месяцев назад +2

    Anyone notice what is on the light switch it says hue g reaction

  • @CuongPhan-fl8vn
    @CuongPhan-fl8vn 7 месяцев назад

    Thank for your video.

  • @FireAlarmGuy-8090
    @FireAlarmGuy-8090 10 месяцев назад +1

    Can you film. A another security system testing

  • @carsonkalinowski
    @carsonkalinowski 10 месяцев назад +3

    Where do you get the items for the system?

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +1

      eBay mostly

    • @leafmk
      @leafmk 10 месяцев назад

      @@nics-systems-electric same

    • @carsonkalinowski
      @carsonkalinowski 10 месяцев назад

      Thanks I’m glad to see your dedication to the community and your channel

  • @Dilsonalarmsandelectrics
    @Dilsonalarmsandelectrics 10 месяцев назад +1

    When is the next durability testing video gonna happen, because when I watch the first part of this video, I wanted to know the durability testing video going to happen ?

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +1

      Hard to say there might never be anymore

    • @Dilsonalarmsandelectrics
      @Dilsonalarmsandelectrics 10 месяцев назад +1

      Bro, rest in peace of durability testing videos😢😢😢😢😢😢😢😢 hopefully I get to see another one

    • @Dilsonalarmsandelectrics
      @Dilsonalarmsandelectrics 10 месяцев назад +1

      I have a fire alarm system in my house just like yours in the moment, I heard the news that you might not do any more durability testing videos my fire alarm system started screaming😂😂😂😂

  • @CGray1234
    @CGray1234 10 месяцев назад

    Yeeeaaahh i’ve been waiting for this one for a while

  • @MitchGaming381
    @MitchGaming381 10 месяцев назад +2

    3030's do have autoprogram

  • @Huey-Gamer
    @Huey-Gamer 10 месяцев назад +1

    Next power outage at your school can you pull the fire alarm?

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад

      That's illegal and even if not I have lots of videos of the fire alarm system at my school

    • @Huey-Gamer
      @Huey-Gamer 10 месяцев назад

      oh. okay@@nics-systems-electric

  • @Bama817
    @Bama817 10 месяцев назад

    I love your videos. They're educational and fun. One of my favorite pull stations is the Edwards SPO 270.
    By the way your dog is beautiful. Is she a purebred German Shepherd? Can you do a video of her if at all possible?

  • @michaelhinchey
    @michaelhinchey 7 месяцев назад

    Could you explain with props the loop system and t tap etc in a video?

    • @nics-systems-electric
      @nics-systems-electric  7 месяцев назад

      There is no T taps on this system it is wired as a class B Loop

  • @Big_Noob-ROBLOX
    @Big_Noob-ROBLOX 10 месяцев назад

    The intro is very weird and cool nic

  • @onefastslimjim
    @onefastslimjim 10 месяцев назад

    Whats the context to "HUE G RECTION", because thats fuckin hilarious lmfao

  • @TransGalGaming
    @TransGalGaming 7 месяцев назад

    i gotta know.. how did you talk your family into adding a firealarm system!?

    • @nics-systems-electric
      @nics-systems-electric  7 месяцев назад

      I didn't, Old smoke alarm were not good needed something new so I installed this.

  • @margaritamendez1028
    @margaritamendez1028 Месяц назад

    The position next to the garage

  • @Firealarmperson902
    @Firealarmperson902 10 месяцев назад

    good job nic looks good

  • @adamcrane6306
    @adamcrane6306 10 месяцев назад +1

    Hello NIC’S - SYSTEMS & ELECTRIC

  • @DanTDMJace
    @DanTDMJace 3 месяца назад

    What would happen if you programmed a pull as a smoke

  • @TeeVeeStudiosAnimations
    @TeeVeeStudiosAnimations 10 месяцев назад

    Awesome video man!

  • @Corwin09-ji8sx
    @Corwin09-ji8sx 10 месяцев назад

    So, how much has the House Fire Alarm System cost to get all parts and wiring (CA$)?

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад

      Wire and boxes were free as well as the 320c panel itself so $3422 is the current cost

  • @Huey-Gamer
    @Huey-Gamer 10 месяцев назад +1

    i love your vids and where do you buy all of your notifier products?

  • @larrysmith8281
    @larrysmith8281 5 месяцев назад

    I love your sistem can you do it im my entier home and the apartmint

  • @bjthedjdutchdude1992
    @bjthedjdutchdude1992 10 месяцев назад

    Hi Nic. Great video. I love watching them. Im looking for that video where you swapped a bell with one of your bells. Do you know the title of that one?

  • @rianflynn2765
    @rianflynn2765 10 месяцев назад

    Can make the house fire alarm system give you notifications on your phone?

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад

      It does the video on it will be out one day it's the same thing as I use in the garage system

  • @EntertainmentFactory-yz1ij
    @EntertainmentFactory-yz1ij 10 месяцев назад

    great vid i subbed!

  • @northwestindianaeas2450
    @northwestindianaeas2450 10 месяцев назад

    My Middle School Needs A New Fire Alarm System. The Current System Is Conventional And Very Old. We Need Something Like An MS9600UDLS Or An NFS-3030 And New Alarms Such As The Gentex Commander 3 Or A Wheelock Exceeder.

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад

      Your old conventional system will probably outlast anything new if it's still works I don't see anything wrong with it

  • @michellebertrand7702
    @michellebertrand7702 10 месяцев назад

    House on fire, Again!? Also new fish tape I see.

  • @enricodigi
    @enricodigi 10 месяцев назад

    Could you do a video on how speaker shutdown works please

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад

      Fire alarm relay connected to other the entire power supply or auxiliary shut down terminals it's as simple as that

    • @enricodigi
      @enricodigi 10 месяцев назад

      Ok cool

  • @busdriver1247RigsofRods
    @busdriver1247RigsofRods 10 месяцев назад +1

    When I wanted to install my photo and I didn't want the residential smoke alarms. I have a photo electric so this was safe. I took my hammer and smashed the smoke alarm.

  • @rodgodx345
    @rodgodx345 10 месяцев назад

    ahhh there it is LOL

  • @julieuehline9334
    @julieuehline9334 25 дней назад

    Get started routines

  • @julieuehline9334
    @julieuehline9334 25 дней назад

    Trfff
    4:35

  • @cwanto5061
    @cwanto5061 10 месяцев назад +1

    Hue G Rection

  • @suehines8451
    @suehines8451 9 месяцев назад

    Lol Run away from problems lol

  • @West_Kootenay_railfan
    @West_Kootenay_railfan 10 месяцев назад

    Hi

  • @Musiocmonkeh
    @Musiocmonkeh 10 месяцев назад

    can I make a nic edit/ movie

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад

      You can do whatever you want

    • @HenBasketFireAlarms
      @HenBasketFireAlarms 10 месяцев назад

      That actually sounds like a fun idea. Something along the lines of “Pickle 700 out of context”

  • @ILVT_Plumbing
    @ILVT_Plumbing 10 месяцев назад +1

    Why does it say "HUE G RECTION" on the light switch plate?

  • @ILVT_Plumbing
    @ILVT_Plumbing 10 месяцев назад

    you should have lined up the pull station with the light switches

    • @tallman11282
      @tallman11282 10 месяцев назад +1

      I agree it would look better but he couldn't as he's following code as much as possible and there is a small height range the handle of the pull station can be in and that's below the switch height.

    • @nics-systems-electric
      @nics-systems-electric  10 месяцев назад +1

      Yes I think we can all agree that things look better if they're all lined up but that's not always legal which if I didn't somebody would be upset with me for that so either way I will end up with somebody upset

  • @TyphoonTip970
    @TyphoonTip970 10 месяцев назад +1

    Hue G Rection