WIRING MODIFICATION IN NEW FAIVELEY WSP SYSTEM

Поделиться
HTML-код
  • Опубликовано: 2 окт 2024
  • Solution to repeated Power ON issue in Faiveley AEFG2 WSP system.

Комментарии • 7

  • @purushottamahire6813
    @purushottamahire6813 8 месяцев назад

    Sir inhibit wire Remove bad software update 102 to 104 kse Krna plz vedio bana ye gaa

    • @coachingdepottvc8814
      @coachingdepottvc8814  5 месяцев назад

      That work is currently being done by Faiveley itself. Its better to let them do it.

  • @sreekalavm3779
    @sreekalavm3779 3 года назад

    Kindly post a video on hand brake attention in lhb coach

  • @jayachandranjoy
    @jayachandranjoy 3 года назад

    Nice sir

  • @santudas9482
    @santudas9482 3 года назад

    Sir in AEFG2 model coach if all 4 dump valve exhaust air for longer time than the usual time , then what to do.

    • @coachingdepottvc8814
      @coachingdepottvc8814  3 года назад +1

      Sir, it will be because the three wires to a single dump valve are connected in wrong sequence. The exhaust valve wire is now connected to brake valve. Try interchanging the wiring of each individual dump valve

    • @santudas9482
      @santudas9482 3 года назад

      @@coachingdepottvc8814 thankyou sir