THE OFFICE AC IS NOT WORKING

Поделиться
HTML-код
  • Опубликовано: 18 апр 2024
  • Trying to find the root cause is what I try to do every time.
    HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com
    Please consider supporting my channel by
    Becoming a Patreon member - Patreon / hvacrvideos
    Becoming a RUclips channel member / @hvacrvideos
    By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
    Visiting my website and purchasing merch www.hvacrvideos.com
    HVAC OVERTIME CHANNEL LINK - / hvacovertime
    Social Media
    Facebook / hvacr-videos
    Instagram / hvacrvideos
    For any inquiries please contact me at chris@hvacrvideos.com
    Mailing Address
    HVACR VIDEOS
    12523 LIMONITE AVE.
    440 - 184
    MIRA LOMA, CA. 91752

Комментарии • 128

  • @tmo26
    @tmo26 Месяц назад +94

    You are one of the few people on this planet who are able to admit that they made a mistake. You took viewers feedback serious, corrected your mistake and reuploaded your video. Kudos for that!

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад +12

      Thanks

    • @SuburbanDon
      @SuburbanDon Месяц назад +3

      When I make one, I'll let you know.

    • @shovon134
      @shovon134 20 дней назад

      Yeah, he's my mentor. Although I'm not involved with hvac.

  • @ericr.117
    @ericr.117 Месяц назад +51

    Don't be so hard on yourself, Chris. Armchair generals, quarterbacks, and techs are always going to be right. In the heat of the moment when you're working, things can be misspoke. You're one of the best techs I've seen, and your ability to explain and train is impressive. This is coming from a 30-year installer/tech/manager/now owner. For what that's worth. Kudos to you for highlighting your mistake.

  • @DanO181919
    @DanO181919 Месяц назад +39

    “Show me a person who has never made a mistake and I'll show you someone who has never achieved much.”

    • @ebfsystem
      @ebfsystem Месяц назад +1

      Thanks for this !🍻

    • @brucejones2354
      @brucejones2354 Месяц назад

      The idea is to NOT Keep making the same mistakes over and over again!
      Try a different one next time ! ! !

    • @HappilyHomicidalHooligan
      @HappilyHomicidalHooligan Месяц назад +1

      Either that or you'll show us someone that it lying through their teeth...

  • @krazy1z
    @krazy1z Месяц назад +11

    One reason why I always suggest your videos to everyone is your honesty. You don't pretend to be perfect and leave mistakes there for others to see and also learn from.

  • @alnonymous9361
    @alnonymous9361 Месяц назад +6

    It takes a good man to admit they made a mistake, that’s why you’re a great HVAC/R tech.

  • @user-ev8tv1qe1z
    @user-ev8tv1qe1z 11 дней назад +2

    ALL GOOD MAN , IT HAPPENS . DON'T STOP YOUR GREAT WORK!

  • @marcolanza5132
    @marcolanza5132 Месяц назад +5

    Brother, you are smarter than 95% of techs I know. Keep making these videos!

  • @Natsumidragneelkim
    @Natsumidragneelkim Месяц назад +5

    I showed my friend your videos and he is now using them to train his employees

  • @JeffreyJakucyk
    @JeffreyJakucyk Месяц назад +11

    7:40 great visual of refrigerant boiling out of the oil!

  • @NereidSpaceman
    @NereidSpaceman Месяц назад +4

    I personally love rivnuts, fantastic for stripped holes for panels mounting things in sheet metal. I'm putting them in all the time. But not for something like a compressor. They should have welded a nut on the bottom, or something beefier. Also, it's big of you to admit it when you said something incorrectly. I don't watch your content because you're perfect, I watch it because you're a fantastic tech and even though I've been in this industry for a long time, you just have a way of explaining things that's easy to listen to and reaffirms my own knowledge. Keep it up Chris 👍

  • @garenharutyunyan4275
    @garenharutyunyan4275 Месяц назад +21

    Anyway, you are the BEST 99.9% We are learning a lot from your detailed videos. THANKS AGAIN CHRIS!!!

  • @ebfsystem
    @ebfsystem Месяц назад +3

    Pro tip:
    When you check for ground scrape some of the paint of the compressor and test it from there,you will get a solid ground by doing that

  • @stacihess9378
    @stacihess9378 Месяц назад +8

    I think you are right about refrigerant migrating back to the compressor and starting with a comp full of liquid. I recently went to a call for a self contained open produce cooler. Unit shut off on high head from a seized fan motor. I pushed the reset and it sounded like the compressor was going to expode. Anyhow, although the hp tripped the solenoid stayed energized and over the course of a few days the refrigerant migrated to the compressor causing the awful sounding recip comp.

  • @MovingHeatLata666
    @MovingHeatLata666 Месяц назад +3

    Top Tier Craftsmen-ship. In the Phoenix area we always quote to replace cc heater, outdoor fan motor, Contactor and Drier. Excellent idea to replace the drier with an HH. Flawless! She sounded like she was purring like a kitten.

  • @JoeCdaYT
    @JoeCdaYT Месяц назад +2

    Just to point out, the windings on all motors have an enamel coating to prevent shorts. The acids will soften the enamel and that will float in the system as a wax like substance. Also scrolls will normally separate a little when they experience over pressure from a liquid getting into the scroll. Depending on design it will either separate enough until there is room for the exhaust valve to allow it to pass or the internal valve opens. This design might be with that coupling does not allow the scrolls to separate with liquid slugging. Always a good video when you get a teardown of the compressors to see what happened.

  • @mrbootedcowby
    @mrbootedcowby Месяц назад +27

    Dang, now I am upset. When I saw that video this morning it had zero lights. And I was the first one to like it😂😂😂

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Месяц назад +12

    Takes a real man to admit a mistake and to make it right. We are all humans, and none of us are perfect in any shape or form. I appreciate your desire to put out the most correct information you can. Bravo Chris

  • @legionofanon
    @legionofanon Месяц назад +5

    I wondered what has happened yesterday, i had a 30 minute old notification for it on my phone, but the video was privated. Nice to be able to watch it now

    • @legionofanon
      @legionofanon Месяц назад +1

      I've also hated rivnuts, one little truck I've found to get a bolt out of them is to use super glue on the nut, if you can access it. Little glue and carefully unbolt and you have a decent chance of unbolting the part.
      I like the concept of rivnuts, but in practice they just suck

  • @whoisderf
    @whoisderf Месяц назад +3

    5:00. Flame outs…..old school trick that usually works. Cold wet rag (I said old school), fold into square, place on the dome of the compressor….. try it!

  • @andenmcleod7355
    @andenmcleod7355 Месяц назад +9

    you are what got me into hvac, been in the field for 5 years now, cheers

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад +2

      Thanks so much for telling me that it made my day!

    • @andenmcleod7355
      @andenmcleod7355 Месяц назад +1

      @@HVACRVIDEOS yeah man, dropped out of highschool after taking my ged, and went to hvac school. your videos definitly help alot and show variety for what to expect on jobs.

    • @Hudson12339
      @Hudson12339 Месяц назад

      @@andenmcleod7355 I'm currently a 16 and going to be doing dual enrollment this fall at my local community college. I've been apprenticing for about 4 months now and can't wait to learn more! It's definitely not an easy trade to learn but I'm excited for the future!

  • @user-hj5le6lo9w
    @user-hj5le6lo9w Месяц назад +3

    I admire your honesty, humility and dedication. Appreciate you sharing your experiences on the field with us. These videos are a good source for building our knowledge of hvac. Damn, how many of us are gonna cut open a compressor shell and investigate what caused the failure? These are the only times we see it.😅 Thanks again! Please keep em coming!

  • @harleyfisher3668
    @harleyfisher3668 Месяц назад +2

    I love your videos and I love you can admit your mistakes thank you for sharing these experiences with us

    • @harleyfisher3668
      @harleyfisher3668 Месяц назад +1

      Also is a flooded start the same as hydro lock

  • @thesilentonevictor
    @thesilentonevictor Месяц назад +2

    It's a learning curve for all of us

  • @torinbrown8196
    @torinbrown8196 Месяц назад +3

    I appreciate the training videos you've been doing brother. On another note I sincerely appreciate a humble person. Much love bro. Stay humble and stay blessed.

  • @Techhead777
    @Techhead777 29 дней назад +1

    Speaking of crankcase heaters, Emerson has recommended installation requirements in their technical bulletins for each compressor model. In general, where the weld seam goes down the length of the compressor, they suggest that the torque nut and bracket cover the weld, not the heating element itself. This is to prevent stretching of the element and also it's generally not a flat surface and there will be an air gap if the heating element were to cover it. The torque recommendations is 20-25 inch pounds. The crankcase heater shown in the video looks a tad bit high. Every compressor will be different, but for example the measurement could be 0.20" - 1.22" from the bottom of the base plate.
    There are crankcase protrusions seen towards the bottom of the body of the compressor. Some bulletins recommend above or below these protrusions depending on the compressor. The main point is that the clamping bracket should be placed over the weld and not necessary convenient for the install or servicing technician. Here's a video to explain it - ruclips.net/video/y3PsTyCN6aw/видео.html

  • @colinclingan8246
    @colinclingan8246 Месяц назад +3

    Glad to see they finally replaced that old junky York unit that caused you such paid with a nice Carrier unit!

  • @colinclingan8246
    @colinclingan8246 Месяц назад +2

    I love how your iPad case is magnetic. Very handy.

  • @Android_Warrior
    @Android_Warrior Месяц назад +11

    Just sign up for my HVAC school yesterday, 12 weeks, wish me luck.

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад +3

      Good luck

    • @halverde6373
      @halverde6373 Месяц назад +2

      You will love it.
      Get the RSES SAMS manuals too.
      It instructs physics.
      A trade school generally doesn't in depth.

    • @halverde6373
      @halverde6373 Месяц назад +6

      I began sweeping a refrigeration shop and being a gofer to brilliant technicians there when I was 10 years old. They apprenticed me and when I got my driving license at 16, they gave me a service truck as I was at journeyman level by then.
      Nearly 50 years doing HVACR and was never without work.
      I'm now retired at nearly 61.
      Until I was 16, they paid me cash under the table so child labor laws weren't violated.🤣

  • @jonl2996
    @jonl2996 Месяц назад +1

    Past 2 weeks been busy and tired but hopefully will be back on the live stream on Monday love your videos and try teaching others while trying to get them to watch your stuff on RUclips.
    Thanks again for all your content

  • @chrisgilbert1916
    @chrisgilbert1916 Месяц назад +2

    I was going to say it but you did. Not adding a liquid line port. Another side note where you mentioned about lines rubbing a dab of silicone in those areas work wonders on potential rub areas.

  • @jsfkdkjslfdslfkdj
    @jsfkdkjslfdslfkdj Месяц назад +1

    Good man Chris. This is why I love to watch your content

  • @KillerF0x
    @KillerF0x Месяц назад +1

    Great video, no criticism here just commenting...
    Those pieces can just break too, from wear or possibly a manufacturing defect or design flaw. Personally I think Scroll's are way more liquid resilient, especially versus a piston type compressor. I used to cut open all the failed scrolls I replaced and I'd say 90% of the time that same coupling piece is what broke. The pieces jammed the rotation (locked rotor), took out a winding (open/grounded winding), or the compressor was just free-spinning and not pumping anymore (low amp draw, no pressure change). I'd actually say its pretty uncommon to find a failed scroll where that piece wasn't broken, for me at least.

  • @carvajal01
    @carvajal01 Месяц назад +1

    Thanks so much for share all this amazing great job you did.

  • @cadgear
    @cadgear Месяц назад +3

    This is exactly why I started watching your channel. You’re human and you admit it without elitism.

  • @alext424
    @alext424 Месяц назад +1

    Awesome video Chris! Thanks so much! 👍🏻👍🏻

  • @wilcleno1866
    @wilcleno1866 Месяц назад +1

    Just goes to show Chris is just one of us! He makes mistakes as we all do. The best admit to it.

  • @HappilyHomicidalHooligan
    @HappilyHomicidalHooligan Месяц назад +2

    If you're right and the failure of the crankcase heater broke the compressor, then perhaps the system should be redesigned slightly so the heater is part of the compressor start-up...
    By that I mean, during compressor start-up the heater is briefly turned on (if it's not cold enough to require it to be used) and if it won't turn on, then the contactor can't pull in to turn on the compressor motor...
    A better system (assuming this won't damage the compressor) is to simply wire the heater in series with the compressor motor so it turns on when the compressor does so if the heater has failed and can't turn on, then the motor circuit also can't turn on and the compressor can't undergo a flooded start due to cold conditions...

  • @markae0
    @markae0 Месяц назад +1

    Thanks for the teardown of the compressor.

  • @davesawyer497
    @davesawyer497 Месяц назад +1

    We all make mistakes Mate, in fact the one who never makes a mistake is the one who has never done anything. Don't worry about it, learn from it, and move on. Another great job done and great diagnostics.

  • @10minutenewhampshirebreak77
    @10minutenewhampshirebreak77 Месяц назад +1

    Nice, thanks

  • @stephencupitt6888
    @stephencupitt6888 Месяц назад +1

    Love your videos Chris- fyi youtube should have an editor where you can put in clip like the intro while keeping the video live... I haven't done it myself so idk the legitimacy, but may be worth a shot!

  • @hrdworkin7633
    @hrdworkin7633 Месяц назад +1

    Thanks for all your videos and all you do for the trade. I've learned much! small note, you kept calling the unit a 6 ton when it was a 5, twice.

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад +1

      It is a 6 ton but it had a 5 ton compressor, carrier does some voodoo magic with the coils that make
      It a 6ton

  • @petenikolic5244
    @petenikolic5244 Месяц назад +2

    Rivnuts are great just have to think a little bit when using them bit of never cease or similar and Tighten it down fully

  • @ovalman
    @ovalman Месяц назад +1

    Hey bro..... Good videos, I enjoy them. Question: what kind of tip do you have on your oxy-acetylene setup? I can't seem to find something that spreads that nice for bigger pipe. Thanks.

  • @squirrelwood8008
    @squirrelwood8008 Месяц назад +3

    Have you considered looking into induction brazing?

  • @glenjones4404
    @glenjones4404 Месяц назад +1

    The clever people learn by there mistakes !!!
    It's the people that make them day out day in 💯
    But yes if this happens in the winter the refrigerant migrates to the coldest place which will be the compressor up on the roof where it needed the crankcase heater working 🥶

  • @ElmerCat
    @ElmerCat Месяц назад +1

    I wonder if it was possible to know the old ham coupling was going bad - then again, putting in a new ham coupling might be more trouble than changing the compressor.

  • @scottporchik96
    @scottporchik96 18 дней назад

    Compressor changeout I’d automatically replace the Crank Case Heater and Contactor.as well.
    I’ve also seen people replace Condener Fan Motors and not replacing Capacitors….
    Doing so I my opinion is like putting old parts in a new Transmission.

  • @jhatfield2755
    @jhatfield2755 Месяц назад +1

    Acid test and acid neutralizer work great

  • @ThunderClawShocktrix
    @ThunderClawShocktrix Месяц назад +1

    It sounds to me like it had just the wrong (or right) amount of flooding enot enough to be outright hydro locked but enough that if it started moving it would do real damage from the inertia

  • @AmazingRoony
    @AmazingRoony Месяц назад

    Hello Scotty, we need some maintenance Here !

  • @exoticsportcars
    @exoticsportcars Месяц назад

    That socket stack is a thing of beauty.

  • @richardbartlett6932
    @richardbartlett6932 Месяц назад +1

    My understanding is that it's not the refrigerant that does the damage, or rather:
    As the compressor sits in cooler climes refrigerant condenses in the oil. On first start up the drop in pressure inside the compressor causes the refrigerant to rapidly evaporate. This evaporation in the oil causes the oil to 'boil' as it sits at the bottom of the compressor.
    The level of the now 'boiling' oil rises (like water level in a kettle rises as it boils. ) Sufficiently to allow too much oil (more than normal and acceptable carry over) to be dragged into the suction inlet port and into the compression chamber. The excessive oil is trapped inside the compression chamber and as it wont compress, hence tries to bust its way out instead...
    Therefore its actually the oil that does the damage not the refrigerant although its the refrigerant that causes the oil to enter in the first place .
    Anyhoo thats my understanding..

  • @malcolmmackenzie9202
    @malcolmmackenzie9202 Месяц назад +1

    7:00 i would have thought keep the 2 cut bolts as locating pins for the compressor. Not sure if it would much though so cutting them off isnt a bad thing.

  • @dyl4446
    @dyl4446 Месяц назад +1

    Why do some manufactures have ambient temperature switches for their crankcase heaters? Iv'e seen a lot of trane units use this design.

  • @noeljunco
    @noeljunco Месяц назад +1

    I've never had an issue with the 3/8 copper with the Navac tube expander I must be lucky..question on the metering device...have you ever ran across a unit that the metering device is not operating properly after a big job such as this?

  • @cyborgsheep6077
    @cyborgsheep6077 Месяц назад +1

    threaded inserts in general are just trash the electrical boxes that get installed in concrete that I work with are the biggest pain

  • @Nyarly_Relyeh
    @Nyarly_Relyeh Месяц назад +1

    Chris, don't be so hard on yourself.
    It looks like you're eating you out in the re-edit.
    Everyone can make a mistake, but there is a few of them who learns from it.
    Get it up, man.

  • @ImZyluxOG
    @ImZyluxOG Месяц назад +1

    is there a reason why you didnt do an acid test on the old refrigerant before recovering?

  • @SupremeRuleroftheWorld
    @SupremeRuleroftheWorld Месяц назад

    crankcase heaters are so underchecked during PM's. its very common that a 50 buck heater (or other part) causes a 15k repair.

  • @zekenzy6486
    @zekenzy6486 Месяц назад +1

    Great Video. Thank you for sharing. May I ask, Why's single phase Contactor use on this 3 phase power hvac unit ? I'm newbie ^_^

    • @inothome
      @inothome Месяц назад

      Cheap American made equipment saving money using two pole contactors instead of three pole contactors.

  • @nathang.1744
    @nathang.1744 13 дней назад +1

    Was the economizer working? Because it’s supposed to bring in outside air if you get a call for cooling and it’s too cold to run compressor right?

  • @Kevin-wj4ed
    @Kevin-wj4ed Месяц назад +1

    Why don't they have 3phase motor starters on 3phase compressors to protect them?

  • @scottgambers8013
    @scottgambers8013 Месяц назад +1

    Hi Chris question how come you don’t use mega press

  • @CoreySnow87
    @CoreySnow87 Месяц назад +1

    Not a HVAC person here but why couldn't the catch all be moved to a more serviceable location for replacement for next time. Does it have to be within X amount of a certain point?

  • @dashcamandy2242
    @dashcamandy2242 Месяц назад +1

    25:53 - Are you throwing shade? 🤣 Just kidding...

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      Throwing shade or paintin shadows

  • @promisel1964
    @promisel1964 Месяц назад +1

    what you do make sense the biggest thing is you admitted the mistake

  • @LadyAnuB
    @LadyAnuB Месяц назад +1

    You want to see mistakes while making RUclips videos, check out the bloopers with the Cutting Edge Engineering Australia videos. Kurtis is a master of machining but his verbal skills do lack a lot of the time 😅

  • @suezq74
    @suezq74 Месяц назад +4

    8:23 oil washed out? That is definitely not good! From my HVACR knowledge as a 13yr old, compressors definitely need oil or else they will seize up. (I forgot to mention, I have autism and I’m interested in HVACR, so I like to learn from AI and HVACR technicians like you Chris)

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      Thats awesome, thanks for watching

    • @suezq74
      @suezq74 Месяц назад +1

      @@HVACRVIDEOS no problem! :)

  • @cyborgsheep6077
    @cyborgsheep6077 Месяц назад +1

    how much longer until Chris puts disco inferno on his brazing montage🤨

  • @kens.3729
    @kens.3729 Месяц назад +2

    GOD knows we ALL make Mistakes because we’re ALL Human. Everyone is entitled to their Opinion but you felt it was Important to Update your video. 👍😬

  • @urosgaber3786
    @urosgaber3786 Месяц назад +1

    Hi Chris, long time viewer from Slovenia here, when you commented that you hoped that the compressor went bad due to single phase running I wonder why you don’t use 3 phase control relays to protect the units? The control relay detects presence and correct sequence of the phases and if you then use it as lock out signal so the unit does not start when there is a problem with input voltage.

    • @inothome
      @inothome Месяц назад

      Pretty sure he was referring to the contactor single phasing the compressor, not the supply losing a phase. To prevent this you would need phase monitors on the load side of each three phase contactor. And in this case, where cheap US manufactures use two pole contactors instead of three pole, the phase monitors would trip every time the contactor de-energized, since there is one phase that is always energized. But, I do agree and I don't understand why more US equipment does not have phase monitors to at least monitor the supply. I see phase monitors on just about every piece of three phase equipment from Asia and EU that I work on and almost never on US made equipment.

    • @urosgaber3786
      @urosgaber3786 Месяц назад

      @@inothome probably right, in EU there is no way this kind of installation (one phase left energised) would be allowed, here all the phases must go through contactor and if present neutral too.

  • @cayden9224
    @cayden9224 Месяц назад +2

    Hey Chris, are you gonna be on the overtime show tonight?

  • @carlyleworkman1928
    @carlyleworkman1928 Месяц назад +1

    👍🏿

  • @freefunky830
    @freefunky830 Месяц назад +1

    Yummmmmmmmm

  • @al6347
    @al6347 Месяц назад +2

    Nice opened a scroll compressor to literally see what caused the failure. Cch a $20 part . How cold temperature wise does that part of the world get in the winter?
    I tell peoples that I know alot but I do not know everything.
    The HVAC&R tech that claims to know everything is a lier.

  • @user-ln7of9gs4s
    @user-ln7of9gs4s Месяц назад +1

    :43 you could have re-uploaded the video, and explain at the beginning why you did it. No one minds. 😁

  • @ryanforde90
    @ryanforde90 Месяц назад +1

    Copeland in there factory’s test there compressors to 90% liquid flood to stress test there compressors

  • @DelticEngine
    @DelticEngine Месяц назад +2

    Sorry to be the bearer of bad news but, despite the re-edit, you've made the same mistake twice regarding the operation of the compressor in that you described the moving scroll as sliding back-and-forth when in reality it orbits within the fixed scroll to provide the compression. In fairness, though, you did say 'orbiting scroll' in the commentary at the end.
    Regarding flooded starts, it would be relatively simple for manufacturers to implement a sensor on the compressor to detect this condition and prevent the compressor starting in extreme circumstances. An extra port on the side of the compressor with a window for a optical sensor would be one method though there may also be electrical/electronic methods of achieving the the same thing, even going so far as measuring the liquid level within the compressor casing. As there are low oil level systems on compressors, why not a high level sensor?

    • @dmiestercommkitchentech3043
      @dmiestercommkitchentech3043 Месяц назад

      Dude he doesnt make the compressor take that idea to Emerson it a great idea

    • @inothome
      @inothome Месяц назад

      Just one more thing to fail, leak or go wrong. Risk vs reward, how many compressors would be saved vs how many more nuisance problems would it create?

    • @DelticEngine
      @DelticEngine Месяц назад

      @@inothome As there are already compressors with extra connections, both refrigerant and electrical, where the extra connections are not problematic I don't see a problem.

  • @mackenziegray2090
    @mackenziegray2090 Месяц назад +1

    How come your technicians are always quiet?

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      They respect the fact that I’m filming

  • @jo6520
    @jo6520 Месяц назад +1

    This is kind of a part 2.

  • @rickchapman9232
    @rickchapman9232 Месяц назад

    Why was that one cup of oil acting like a beer?

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      Good question, Ill try and talk about that a bit more on the live stream this Monday

    • @dmiestercommkitchentech3043
      @dmiestercommkitchentech3043 Месяц назад +1

      It was refrigerant in the oil boiling off and escaping into the air

  • @Uhh.thankyou
    @Uhh.thankyou Месяц назад +1

    I swear I watched video like 7 months ago? Either that or it’s the same unit

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      It’s probably the same unit, I think I did a leak repair on this unit before

    • @Uhh.thankyou
      @Uhh.thankyou Месяц назад +1

      @@HVACRVIDEOS ah yes I thought so, great vid keep them coming

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      Thanks bud

  • @JamesTK
    @JamesTK Месяц назад +1

    That's not oil you poured yourself a drink

  • @elcrazy8017
    @elcrazy8017 Месяц назад +1

    Everyone makes mistakes who cares. Nobody is a super tech. I don’t care what they say

  • @petenikolic5244
    @petenikolic5244 Месяц назад +4

    I was watching that when you pulled it thoght aye up have i annoyed someone

    • @peewee3ie
      @peewee3ie Месяц назад +2

      I was also watching it when it got pulled yesterday and did send an email to see what happened but no reply

    • @cedrickrenn7152
      @cedrickrenn7152 Месяц назад +1

      Same. Was listening to the closing words when it got pulled…