  • @nsubugadeo7256
    @nsubugadeo7256 9 месяцев назад +2

    Nice lecturer🎉

  • @identidem
    @identidem 2 года назад

    Thanks a lot o was looking for this for a long time but didn't find much info.
    The span I have is 22 ft.
    Columns 9*14inches, 4 bars16mm and 2 bars 12 mm door/lintel beam is 6inches and the roof beam is 12 inches deep 16mm bars. Will it be sufficient?

  • @truedecors5941
    @truedecors5941 2 года назад +1

    Super explanation direct to core content

  • @venu511
    @venu511 2 года назад +1

    Good video sir..more information 👌👌👌👌

  • @bollusrinivas
    @bollusrinivas 2 года назад +4

    Column size 9/15 with 6 Rods(16mm 4bars and 12mm 2bars with 8mm rings @6inch) and distance between two columns is 15.8feet. two rooms, each 12feet/15.8feet. Footing 6.5feet depth width 4x4, with 1feet 40mm and 2.5feet 20mm. Is this good for g+2 residential building?

  • @kennethwhite5158
    @kennethwhite5158 2 года назад

    Sir, If we have four steel rods on the bottom of the beam and three steel rods in the column to tie off to how is it possible to tie the two middle rods in the beam to one middle rod in the column? I'm confused.

  • @anilshukla8075
    @anilshukla8075 2 года назад +1

    Excellent knowledge

  • @fasterfaster5960
    @fasterfaster5960 2 года назад

    Baraka lahou fikkk

  • @engrraufkhan9876
    @engrraufkhan9876 2 года назад +7

    Nice lecture,sir Explain Difference between Tie beam and plinth beam

  • @ameehasa5504
    @ameehasa5504 2 года назад

    How many crank bar we should use? I hope if u have video for framing on all type of soil

  • @KusaasiraNoah7421
    @KusaasiraNoah7421 2 года назад

    can you use 16mm diameter bars in columns and 20mm in beams?

  • @mohammadmuslim5694
    @mohammadmuslim5694 2 года назад +1

    Good lecture

  • @pradeepSuriyabandara
    @pradeepSuriyabandara Год назад

    Thanks for the lesson what about if this G + 2 story with 5 ton of load

  • @murthyau6620
    @murthyau6620 2 года назад +3

    Can we know from you, the load bearing of our existing Residential structure, to go for further floors, at professional consultation. Then how to communicate, please. Regards.

  • @ph6263
    @ph6263 2 года назад +1

    Sir My newly constructed house have one of the beam of length of 5.2 m (16.5 ft) and one secondary beam is tested on it. It is 230×300mm but we used 4 no of steel bars of 16 mm at bottom and 2 nos of 16 mm + 1 no of 12 mm at top.
    So ll it sustain to that amount of load for longer period or developed crack???
    As I see many engineers recommend more than 450 mm deep beam.

  • @faruqahmedbusiness1105
    @faruqahmedbusiness1105 2 года назад +1

    Will you show the analysis. Formula or thumb rule for column and footing design like beam depth formula l/20 for depth.

  • @dreamer69223
    @dreamer69223 Год назад

    Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??

  • @amols9634
    @amols9634 2 года назад

    L/20 for 19 feet span 285mm depth so safer side you have to take 230x 380

  • @kaungsettlinn1179
    @kaungsettlinn1179 2 месяца назад

    ACI code(Beam is. span× 0.75=beam depth)

  • @syedabdulquddus3469
    @syedabdulquddus3469 2 года назад

    supper sir, Thank you very much

  • @ayaan5633
    @ayaan5633 2 года назад

    Can you do your future video measurements in feet and inches.?

  • @phyohtetkoko929
    @phyohtetkoko929 Год назад

    Thanks For Teaching Sir

  • @ariezaziziacahlebih2637
    @ariezaziziacahlebih2637 2 года назад +2

    Salam sir, does this can apply to 21 ft span?

  • @khan52310
    @khan52310 2 года назад

    If I have 24 feet span and other side is 26 feet span for G plus 1 story home only, please reply

  • @byrappakaramaradi4070
    @byrappakaramaradi4070 2 года назад

    What should be the height of building?

  • @waluohopaulo2116
    @waluohopaulo2116 2 года назад

    Well understood

  • @paonamdineshmangang6179
    @paonamdineshmangang6179 2 года назад

    Sir is it OK to put 4 Steel rod of 16mm on top and 4 on bottom of 17.5 feet long beam

  • @defersonlyngdohmawlong708
    @defersonlyngdohmawlong708 2 года назад

    G 1 G2 G3 means what? Does it mean 1floor 2floor

  • @sridharsahoo489
    @sridharsahoo489 2 года назад

    Sir u could not say top reiforcement which mm bar used in this video

  • @Mithushahome
    @Mithushahome 2 года назад

    Super bro

  • @moamar7585
    @moamar7585 2 года назад

    what is the thickness of footings?

  • @intkhabahmad453
    @intkhabahmad453 Год назад

    Steel volume should be 1-2% of RCC volume for beam. Calculate it

  • @akojuravisankar3492
    @akojuravisankar3492 2 года назад

    Thank you for giving good information about construction building.

  • @hemantasingh8606
    @hemantasingh8606 2 года назад +2

    6 nos of 16mm in beam (10X12) for 20 feet span.column (12x12) 4 nos 16mm &4 nos 12mm for single room .can we build g+2?

    • @kswvidioyoutube8816
      @kswvidioyoutube8816 2 года назад

      It's possible even I'm doing my own house with four 16 mm andtwo 12 mm in one biller size is 8/10

  • @aemisection4460
    @aemisection4460 2 года назад

    please post a video for culvert reinforcement details and designs

  • @UmeshSahu-di2ee
    @UmeshSahu-di2ee 2 года назад

    Wow bhai....

  • @ningthoujamnewtonmeitei5137
    @ningthoujamnewtonmeitei5137 2 года назад

    Sir can it apply in normal residential building

  • @premjitchakpram4201
    @premjitchakpram4201 2 года назад +1

    How about if we made column size 12x12 for G+2 residential house with steel rod of four 16mm and four 12mm?

  • @muruganmuthusamy9976
    @muruganmuthusamy9976 2 года назад

    Fine

  • @manjunathbc3655
    @manjunathbc3655 Год назад

    What should be size of beam and column and size of steel which is 7 meters and roof size and steel size G+3

  • @lakshmanang8316
    @lakshmanang8316 2 года назад

    I have one doubt ,
    In your previous video you say As per Indian standard min depth of beam is d/16 = 19/16= 1.2 ft but you say now 1 ft is enough . how !?

  • @izharulhaq8435
    @izharulhaq8435 Месяц назад

    And calculate the no. Of beams for 40 by 16 feet

  • @lakshmanang8316
    @lakshmanang8316 2 года назад +1

    Need plinth beam design

  • @salimmahmud1614
    @salimmahmud1614 2 года назад

    Maa shah Allah

  • @kswvidioyoutube8816
    @kswvidioyoutube8816 2 года назад

    Very nice explaination but not for the poor peaple it's too much and it will be very expensive less size column beam can biuld G+2

  • @engrijazali282
    @engrijazali282 Год назад

    if the span btween 2 column is 16ft...and the building is G+1+2 than explain size of column and beam...

  • @namahshivay8978
    @namahshivay8978 Год назад

    Thanks 👍❣️

  • @izharulhaq8435
    @izharulhaq8435 Месяц назад

    No. Of beams used for 40 by 16 feet

  • @muhammadtahirmushtaq6300
    @muhammadtahirmushtaq6300 2 года назад

    good mashallah

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 Год назад +1

    What will be the size of footing for same building if soil bearing capacity is 70kn/m2?

    • @SandeepKumar-eg1kw
      @SandeepKumar-eg1kw Год назад

      It is good decision to choose deep foundation than shallow foundation if you cam to know soil is till 70kn of bearing

  • @musahhamid5461
    @musahhamid5461 2 года назад

    Pls I need picture of G+1 and G+2 story building

  • @awishhamza6368
    @awishhamza6368 5 месяцев назад

    12x9'' beam isn't safe for 19-20 feet span in beam column structure. do stress analysis

  • @nyantehemmanuel7089
    @nyantehemmanuel7089 6 месяцев назад

    maximum span between columns

  • @logisticsh.n.a.a4136
    @logisticsh.n.a.a4136 2 года назад

    Do pakistan and india have the same engineering principles for rcc construction .

    • @MehrbanRana
      @MehrbanRana 2 года назад +1

      Dear All over the world is same principles.
      Even here in GCC countries are same principles.

    • @logisticsh.n.a.a4136
      @logisticsh.n.a.a4136 2 года назад

      @@MehrbanRana thanks .

  • @shanjaiks7583
    @shanjaiks7583 2 года назад

    We are watching a religious programe . Inshallah

  • @muhammadafzaal8670
    @muhammadafzaal8670 2 года назад

    Agr urdu mai lecture daitai to aor acha hota......

  • @himangshupatra5000
    @himangshupatra5000 2 года назад +1

    SIR I HAVE 16 feet span G+1.stroy, i have provide beam ( 9 inch *12 inch ) , with 16 mm 2 bar, and 12 mm 1 bar at bottom, and 2 bar of 12 mm at top with 8mm stirrups @150mm c/c spacing, is it safe?? Also column size -(9"*15")

    • @ayaan5633
      @ayaan5633 2 года назад

      absolutely save for G+1

    • @trishan2739
      @trishan2739 2 года назад

      Can you explain that what is column and beam size with how many steel used with size
      Also length and width distance of each column

  • @ramakantapradhan7932
    @ramakantapradhan7932 2 года назад

    If column to column clear span 19', i want provide 6 nos 12mm bar in column and in beam 16mm 4nos bar, any problem plz solve it

  • @intkhabahmad453
    @intkhabahmad453 Год назад

    Your beam steel is not correct for 19 ft span... Moreover depth of beam is also very less for 19 ft... It should be minimum 19 ft... Rest of the calculation and suggestions are well.

  • @palashmatubber8496
    @palashmatubber8496 Год назад

    I love u sar

  • @DeepakKumar-oo9si
    @DeepakKumar-oo9si 2 года назад

    18fit distance mi kon sa colum lgta hi

  • @izharulhaq8435
    @izharulhaq8435 Месяц назад

    Please answer my question

  • @nawalshrivastav6032
    @nawalshrivastav6032 Год назад

    Please hindi Language used.

  • @muzammilkhan3054
    @muzammilkhan3054 2 года назад

    Abhe main br 16 mm aygi

  • @252adeshpatade3
    @252adeshpatade3 2 года назад

    Sir for 3 storey house
    6 no 12mm bars are sufficient or not
    Column size 9 * 15 "
    Please guide

  • @idriveridesharing6493
    @idriveridesharing6493 2 года назад

    It's all confusing

  • @faritherwandy2126
    @faritherwandy2126 2 года назад

    Not economical.