  • @Bazujkaz
    @Bazujkaz 3 года назад +3

    It's monolithic structure. So big top moments near supports possible. Thats also a reason for crank bars.

  • @motalibaluyodan8616
    @motalibaluyodan8616 2 года назад +1

    .is there specific lapping location for crank bar... like this video 20ft apart id qe use crank bar then 20ft long rebar could be a little bit short...

  • @erkundanyadav
    @erkundanyadav 3 года назад +5

    Angle should be 135 degree for stirrups bending to counteracts during any deflection

  • @burhanhashmi5355
    @burhanhashmi5355 3 месяца назад

    Can such a beam support the weight of a room wall over it? If not, what kind of beam can carry the load of a 12' high, 9" thick wall??

  • @dr.fakhar
    @dr.fakhar 2 месяца назад

    what is ideal spacing for stirups at ends and in the center 10 feet?

  • @Harindra000
    @Harindra000 Год назад

    You saved my day!
    Million Thanks!

  • @balrajkotakari8041
    @balrajkotakari8041 3 года назад +3

    This beam top tention zone lapping how.??

  • @BestBeatsClub
    @BestBeatsClub 2 года назад +2

    Thanks for the knowledge

  • @mbens9266
    @mbens9266 3 года назад +3

    "...especially for commercial buildings..." Distances between stirrups do not depend on whether or not the structure is for "commercial building" sir.

  • @jameel.akhtar12
    @jameel.akhtar12 Год назад

    Agar yeh beam 25 feet long ho or 18 inch beam ho tou oper or neechy kitni baars daalen gei

  • @Kemy96
    @Kemy96 Год назад

    Do you still need stirrups close together near the ends even if you have crank bars? Can you do one out of them or you have to do both close stirrups and crank bar?

  • @harnamsingh7426
    @harnamsingh7426 2 года назад

    If we want to make 10 ft horizontal beam with one vertical beam, than how we use steel bar for the said horizontal beam. Please answer my question.

  • @chegensangma1623
    @chegensangma1623 Год назад

    In this beam what steel is used is it 10mm Or 12 mm and can you tell size of the beam? Sir as well as column size and steel used...

  • @Aviator0215
    @Aviator0215 7 месяцев назад

    Sir can we provide two hidden beams in 20 by 20 hall with 20 mm and 16 mm bars?

  • @emadmansoor1817
    @emadmansoor1817 2 года назад

    God bless you wishing you all the best

  • @harnamsingh7426
    @harnamsingh7426 2 года назад

    Sir it is very interesting vdo.

  • @rastihussein4796
    @rastihussein4796 3 года назад +2

    Thank you! Helpful video 🙌

  • @dionthomas2004
    @dionthomas2004 2 года назад

    My Brother you are great

  • @kedarkumare848
    @kedarkumare848 Год назад

    Super information

  • @mdzakirhossain682
    @mdzakirhossain682 2 года назад +3

    Nice video. For 16 feet span beam (10X15), can I use 4 straight bars at the top and 4 straight bars at the bottom instead of any cranked bar?

  • @josephpinto8378
    @josephpinto8378 3 года назад

    I like it 👍 Fantastic and Suppper 👍

  • @rycordavisol
    @rycordavisol 3 года назад +1

    thank you so much Engr.
    Great Job

  • @susaankafle197
    @susaankafle197 3 года назад +1

    If the depth of slab is

  • @rajdhar327
    @rajdhar327 3 года назад +2

    1. Up to what length 2" spacing in stirup should be given? And after that what should be ideal spacing betwen two consecutive stirrups?
    2. Open ends of stirrups should be placed whether on upper side or lower side?

  • @brindaassociated6721
    @brindaassociated6721 2 года назад

    Kitne mm ki steel daali hai ye kyo nahi batya

  • @kinamaerick1568
    @kinamaerick1568 Год назад

    Thanks for insight it is really helpful,Is the crank provided for all beams or long span only

  • @davidzothansanga6731
    @davidzothansanga6731 3 года назад

    Interesting vedio

  • @manjittalukdar3139
    @manjittalukdar3139 Год назад

    What's the plan .. it is for G+2 or above...?

  • @juvvalaanusha6641
    @juvvalaanusha6641 Год назад

    Nice information

  • @lkdsamte4910
    @lkdsamte4910 2 года назад

    Very good explaining

  • @mkalimikidadi2597
    @mkalimikidadi2597 Год назад

    Can you have the same number of bars and size of the beam for 7m distance between columns? without increasing beam width and depth putting into consideration bent up bar to L/4 for 7m, also stirrup details as you instructed

  • @Athar_Irfan_reacts
    @Athar_Irfan_reacts 2 года назад

    Sir, do i need crank bar if i provided 4legged beam with 4 no. Of bars at top and bottom

  • @ajaykumar-rm8mu
    @ajaykumar-rm8mu 8 месяцев назад

    Very nice

  • @aizazullah8848
    @aizazullah8848 6 месяцев назад

    Thanks alot

  • @prasannakumarcooldude7589
    @prasannakumarcooldude7589 Год назад

    Great work well explained

  • @lindonlezama6916
    @lindonlezama6916 2 года назад

    You really good

  • @mkalimikidadi2597
    @mkalimikidadi2597 Год назад

    Very insightful thank you

  • @muhammadafzaal8670
    @muhammadafzaal8670 3 года назад

    Yar huda k leye Urdu mai bolai.
    Buht achi video bnatai ho. Lyken agr urdu mai hoti to aor bi achi hoti

  • @theviswaskoundinyan536
    @theviswaskoundinyan536 3 года назад

    very nice video.... thank u

  • @mdziauddin3666
    @mdziauddin3666 3 года назад

    Boss if coming like this mistake on inspection time its will be rectified or not

  • @muhammadshakeelahmed2839
    @muhammadshakeelahmed2839 Год назад

    bhia, try not to repeat the conversation again and again. some where video is self explanatory, just hints required. anyway, good effort

  • @asmakhalid4562
    @asmakhalid4562 2 года назад

    Very informative. Please make more videos on site for practical explanation.
    Also please discuss the loads and the resulting structural design.

  • @builttolast5249
    @builttolast5249 Год назад

    We have use 6 bars. 2 bars 16mm and 1 12 mm in top and in bottom 3 bars of 12 mm. Is it good

    • @builttolast5249
      @builttolast5249 Год назад

      Slab beam size is 9×12 and plinth beam. Size is 9×18

  • @edwinorcino9312
    @edwinorcino9312 2 года назад

    Goog pm .Sir what are the sizes of the deformed bar and the stirrup you used in your illustration? Thank you

  • @robertswanson6774
    @robertswanson6774 2 года назад

    Hello sir was this a commercial building g+?

  • @ghadman1061
    @ghadman1061 Год назад

    Awesome job mate

  • @ShivaKumar-qb6qt
    @ShivaKumar-qb6qt Год назад

    Sir for 26 feet between the two coloum is ok

  • @azsk5712
    @azsk5712 2 года назад

    20by30.feet.slab.ma.kitna.mm.steel.ànd.distance.ķitna.rakhey.20.feet.latakta.steel.size

  • @nikhilv803
    @nikhilv803 3 года назад +1

    Sir what is the cost of a plan for 40 40.

  • @edwinmoree833
    @edwinmoree833 3 года назад +1

    Great job my friend

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 2 года назад

    Why not provided secondary beam?

  • @himanshusing21
    @himanshusing21 2 года назад

    So much helping

  • @ogunsolaoluwaseun9471
    @ogunsolaoluwaseun9471 8 месяцев назад

    Weldone,pls send the structural drawings for this particular video

  • @shafiadam5739
    @shafiadam5739 3 года назад +1

    Hook are bending with135°or not 90,*

  • @williambitaseme4067
    @williambitaseme4067 3 года назад

    Good Morning and win today,
    Good illustration. is it possible to have a beam of 9. 90m at simple support without intermediate support. how is it designed.
    God bless you
    thanks

  • @PavanKumar-sq9xj
    @PavanKumar-sq9xj 3 года назад

    Sir it is continous or simply supported beam

  • @goutamkumarda3535
    @goutamkumarda3535 2 года назад +1

    Thanks sir...💘
    Will you please clear is the size of beam without concrete is same for all design

    • @vi683a
      @vi683a 2 года назад

      No beam size it not standard.

  • @190hima
    @190hima 3 года назад

    What is the benefit of using sheets under the rebars??

  • @saarthakkumarlal6371
    @saarthakkumarlal6371 2 года назад

    Sir size of beam without slab in this video is...??

  • @civilengineerteluguvasthu5365
    @civilengineerteluguvasthu5365 3 года назад +1

    Steel diameter please ?

  • @civilengn
    @civilengn 3 года назад

    Great video. Very good explanation.👍

  • @bishandebnath4262
    @bishandebnath4262 3 года назад +1

    Thank you so much Sir ☺️

  • @randybritto1738
    @randybritto1738 2 года назад

    why not just add 4 whole lenght steel rods ! honest question!

  • @mathewskalungulu7684
    @mathewskalungulu7684 3 года назад

    good illustration

  • @erkundanyadav
    @erkundanyadav 3 года назад

    Nice informative video

  • @DHARIENGICON
    @DHARIENGICON 3 года назад

    Nicely explained

  • @gamingbeast6920
    @gamingbeast6920 2 года назад

    Nice

  • @Gary-pogi
    @Gary-pogi 2 года назад

    What size rebar here?

  • @rahee876
    @rahee876 3 года назад

    Sir, practically I asked the steel fixer to provide 135° in stirrups bending. But in the case of crank Bar (beam) he refused, the reason for that he told that in case of crank bars then it is impossible for us(the steel fixer) to pass the crank bars in the beam as the 135° stirrups provide resistance during arrangement of the crank bars.
    Now if this is the case then what to do Sir?

    • @usmanawan3083
      @usmanawan3083 2 года назад +2

      You can change steel fixers because its possible they were giving only shitt arguments for there own favour, & you should go for 90° Degree as well its up to you

  • @muruganmuthusamy9976
    @muruganmuthusamy9976 3 года назад

    Fine

  • @constructionwork-99
    @constructionwork-99 3 года назад

    Do you design this structure ?

  • @harishkumarsharishkumars848
    @harishkumarsharishkumars848 3 года назад

    Stirrup ?Hooks at bottom

  • @dineshswami3100
    @dineshswami3100 3 года назад +2

    Taking more time to explain

  • @thanglurasailo7623
    @thanglurasailo7623 2 года назад

    There should not be joint at the top side...which they provide in this vedio

  • @seekhainquranwithusman9588
    @seekhainquranwithusman9588 3 года назад

    سر السلام علیکم
    کرنک بار بیم کے اندر کس لئیے دیا جاتا ہے پلیز اردو میں بتا دیں اللہ تعالیٰ آپ کا حامی و ناصر ہو

  • @saifalikhanpathan7729
    @saifalikhanpathan7729 Год назад

    What a diameter of bar .

  • @mohammadballamaabubakar4059
    @mohammadballamaabubakar4059 3 года назад

    Thank you Eng.

  • @harishkumarsharishkumars848
    @harishkumarsharishkumars848 3 года назад

    Beam ht 13 inch ?

  •  2 года назад

    Thanks for you showed some mistake in install rebar.

  • @KashidSunita1996
    @KashidSunita1996 6 месяцев назад

    Continue beam should be in L by 3

  • @seyabkhan7383
    @seyabkhan7383 2 года назад

    I thought you are going to design beam according to load and do calculation
    But you are just talking about parts of beam

  • @usmanawan3083
    @usmanawan3083 2 года назад

    Please make video on overlap in slab & beam also

  • @sashiverma8089
    @sashiverma8089 2 года назад

    रूफ स्लैब कास्टिंग फ़्रॉम बोटम ऑफ़ बीम
    प्लीज एक्सप्लेन

  • @rajdhar327
    @rajdhar327 3 года назад

    Sir, are you Kashmiri? Your dialect resembles Kashmiri dialect.

  • @entertainmentcentre2395
    @entertainmentcentre2395 2 года назад

    How many stories

  • @skcallme9995
    @skcallme9995 7 месяцев назад

    Hindi mein video nahin banaa Sakta

  • @romeosabaldan58
    @romeosabaldan58 2 года назад

    Good video sir. I will subscribe. Hope to exchange information with my construction videos also.

  • @Theuniverse11095
    @Theuniverse11095 Год назад

    Details required

  • @rajeevtiwari368
    @rajeevtiwari368 3 года назад

    Plz give steel dia details

  • @cityengineering3713
    @cityengineering3713 3 года назад

    Pl.give design for 40' length of beam

  • @CivilEngineering93
    @CivilEngineering93 2 года назад

    Which Type Of builing, this is?