✅ Don't forget the Basic Rules of Column design rebar reinforcement | Green House Construction

Поделиться
HTML-код
  • Опубликовано: 6 май 2020
  • Welcome back to Green House Construction!
    This channel shall be replaced Nha Xanh E&C Channel instead. Please follows me "SUBSCRIBE" this channel.
    This video will introduce to you the basic rules of column design reinforcement rebar for your information.
    This a just a basic rules but that was really important for your working.
    in the next video, we will introduce to you 10 rules of column design reinforcement.
    Hope you like this video!
    ✔ Website: nhaxanhvietnam.com.vn
    Hotline: 0974665955
    Fanpage: / nhaxanhchannel

Комментарии • 193

  • @NHAXANHVIETNAM
    @NHAXANHVIETNAM  3 года назад +12

    If you see this video helpful, Please "SUBSCRIBE", like, share for further helpful videos.
    Các bạn nhớ "ĐĂNG KÝ" kênh, like, chia sẽ để nhận được nhiều video hữu ích khác nhé.

  • @Engrwaleed555
    @Engrwaleed555 3 года назад +34

    Want to see same animation for beams, slab and stairs.

  • @khalidrasheed3432
    @khalidrasheed3432 9 месяцев назад +4

    It is a good effort for those who are interested in the basic design requirements of reinforced concrete. I would like to suggest that wrong and right design should be based on industrial codes which will be more helpful for better understanding in which assurance in guaranteed for not denying the industrial standards. Mentioning without such standers right or wrong are having no bases.

  • @muralikrishnagandikota4980
    @muralikrishnagandikota4980 5 месяцев назад +1

    Tq so much for making useful content for our civil engineers

  • @kingsleyumeh1482
    @kingsleyumeh1482 11 месяцев назад +2

    As a Civil Engineering Student, I find this article very useful. Thank you.

  • @ikbalshah7940
    @ikbalshah7940 Год назад +1

    Thank you for your information ❤️👍

  • @MrMohamadfahad1
    @MrMohamadfahad1 2 года назад +5

    Best channel on youtube for civil knowledge 👍🏻

  • @marcelo_rcosta
    @marcelo_rcosta Год назад +1

    Excelente conteúdo!
    Abraços do Brasil 🇧🇷

  • @jamesbladerunner2735
    @jamesbladerunner2735 Год назад +1

    Love it ❤️thankx

  • @Life_is_Awesome_Civil
    @Life_is_Awesome_Civil Год назад +3

    Very nice

  • @RabiulIslam-ug9qt
    @RabiulIslam-ug9qt 2 года назад +1

    Very informative.nice presentation.

  • @sunilgadriya1832
    @sunilgadriya1832 Год назад +2

    Wow ...amazing video sir

  • @phyohtetkoko929
    @phyohtetkoko929 Год назад +1

    Thanks For Teaching Sir

  • @asepraisamarulloh2723
    @asepraisamarulloh2723 2 года назад +1

    Thanks your God video, I follow your next content. Keep Spirit brother... (Jakarta, Indonesia)

  • @Thao7891
    @Thao7891 Год назад

    Good luck ☘️☘️☘️

  • @seksantipapala1878
    @seksantipapala1878 Год назад

    ขอบคุณมากๆครับ

  • @prenumenumedefamilie3418
    @prenumenumedefamilie3418 Год назад +2

    hi there mr engineer !Please tell me at the base of the columns that little step concrete is better to pour in the same time with the slab under ?or just add a little later !What is the dimension of that one ?what high need to be ?

  • @HuyHoang79ag
    @HuyHoang79ag 2 года назад

    cám ơn bạn đã chia sẽ

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  2 года назад

      Cám ơn anh đã ủng hộ Nhà Xanh Việt Nam

  • @athulachandana7883
    @athulachandana7883 3 года назад +1

    Excellent vedio ....

  • @arvinselvarajarvinselvaraj6083
    @arvinselvarajarvinselvaraj6083 7 месяцев назад

    GOOD AND HELP FOR REBAR LEARNERS.

  • @mozmiah5596
    @mozmiah5596 Год назад

    Excellent video very easy to understand 👍🏽👍🏽👍🏽

  • @muhammadhayathayat3472
    @muhammadhayathayat3472 15 дней назад +1

    7:20
    Very informative 👌🏻👌🏻
    Please also upload a video on how to design and construct foundation in hilly areas

  • @hussainkazmi4829
    @hussainkazmi4829 Год назад +2

    Are your specifications according to ACI code?

  • @kazungualbert9441
    @kazungualbert9441 Год назад +1

    Perfect explanation

  • @umeshvyas214
    @umeshvyas214 2 года назад

    Excellent, Thanks

  • @ismaelarellano1586
    @ismaelarellano1586 2 года назад

    Excelente!

  • @sureshbabube
    @sureshbabube 5 месяцев назад +1

    excellent work.. Appreciated

  • @SolidworksUnlimited
    @SolidworksUnlimited 2 года назад +2

    I agree 👍

  • @mymobile011
    @mymobile011 2 года назад +1

    Love you for this

  • @Altricksss
    @Altricksss 11 месяцев назад +1

    On tall buildings, I've always wondered how they extended the length of support columns that have rebar inside.

  • @sscaspirants2024_
    @sscaspirants2024_ Год назад +1

    Hi i from India but I like this information

  • @premsagarjagu8683
    @premsagarjagu8683 Год назад +1

    Tnq .. FULLY SATISFIED

  • @siva2570
    @siva2570 Месяц назад +1

    Thank you very important information. I want 24feet x 24feet ceiling rebar arrange ment without beam structure.

  • @couplelovers9229
    @couplelovers9229 Год назад

    Thanks for you ❤️💯👍

  • @amitnayak5869
    @amitnayak5869 Год назад +1

    We want video on civil aspect of machine foundation like; (use of TMT bar and it's distence calculation)

  • @shashanksrivastava8292
    @shashanksrivastava8292 Год назад

    What a great video sir 🙏🏻🙏🏻🍰🍰🤗

  • @sonukoli8613
    @sonukoli8613 2 года назад +2

    Fantabuls video 😃😃

  • @vs-maniyan682
    @vs-maniyan682 3 года назад

    Excellent

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  3 года назад

      Thank you very much. Have a nice day sir

  • @DroneConstruction
    @DroneConstruction 5 месяцев назад +1

    thank for your video

  • @user-pi6jx6qu4l
    @user-pi6jx6qu4l Год назад +6

    Funny seeing this, coming from a guy that tied steel for 15 years. I've never seen staggered splices on columns. And question: aren't 135* bands for seismic applications? And number of bands isn't called out by load. Edit: is not isn't, excuse me.

    • @q-divinetv8278
      @q-divinetv8278 10 месяцев назад +2

      Then you are wrong for 15 years

  • @madhavanarashimhadasskitch8365
    @madhavanarashimhadasskitch8365 Год назад +2

    Beautiful

  • @brainwavemedia173
    @brainwavemedia173 Год назад

    Ap video banaty kasy ho ?
    Kon sa software use kerty hn?

  • @dadulvai8535
    @dadulvai8535 Год назад +1

    Good knowledge

  • @linhnguyen-xx2lf
    @linhnguyen-xx2lf Год назад +1

    So nice ! ❤👍

  • @jhonaderlybarbozaolivera6414
    @jhonaderlybarbozaolivera6414 Год назад +3

    Reglas de diseño de columnas
    1. 100% de barras de refuerzo superpuestas en una sección
    2. Longitud de traslape sin pendiente (barra doblada) en longitud de barra de refuerzo superpuesta
    3. Todos los lazos con el extremo doblado en una dirección
    4. Los extremos de los lazos no están doblados 135°
    5. Esta área de la zona no es suficiente lazos

    • @travelfanatic9124
      @travelfanatic9124 Год назад

      Why all ties end's are provided in opposite direction? Reason.

  • @yaseenpatel8068
    @yaseenpatel8068 Год назад +1

    This demonstration is done in which software sir ??????

  • @yigrembayleyegn9370
    @yigrembayleyegn9370 Год назад +1

    I like it well done

  • @edwardarikpe9403
    @edwardarikpe9403 2 месяца назад

    Please is it proper for lapping in foundation before DPC?

  • @aaaaaa-pr5gt
    @aaaaaa-pr5gt Год назад +2

    Super!!!

  • @fernandojaramillo736
    @fernandojaramillo736 Год назад +1

    La dimensión del traslape, la dimensión entre flejes , la rotación del remate de los flejes.

  • @EdwinColubioChannelENJOY
    @EdwinColubioChannelENJOY 2 года назад +1

    Full pack already. hope mine too.

  • @mohamedcivwerk1189
    @mohamedcivwerk1189 2 года назад

    good video,

  • @mohammedsiraj4189
    @mohammedsiraj4189 2 года назад +1

    Good sir

  • @user-no5tm8sl2c
    @user-no5tm8sl2c Месяц назад

    بالعراق لا المقاولين ولا المهندسين يفعلون الطريقه الصحيحه ابدا حتى لو ضاعفنا لهم المال لا يفعلون الطريقه الصحيحه

  • @thomasedison1973
    @thomasedison1973 14 дней назад +1

    nice

  • @dangaerlan6906
    @dangaerlan6906 Год назад +1

    I think @ 9:10 to 9:25, lateral ties are incorrectly placed as they don't have ends in 135 degrees bend.

  • @Fredflinstone23
    @Fredflinstone23 2 месяца назад +1

    why is it that you’ll need to over lap if you have sufficient length of rebar? why the rebar does not go all the way to the footing?

  • @halimhafid6996
    @halimhafid6996 2 года назад +1

    thanks alot for your video..on my way to built my own house..subs done

  • @practicalcivilengineer6846
    @practicalcivilengineer6846 3 года назад +1

    plz can u tell me about which software do u use to make things looking realistic
    i am civil engineer in pakistan i will suggest my friends to your channel

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  3 года назад

      Please send to my email your question

    • @richarddrai2750
      @richarddrai2750 2 года назад

      I am a civil engineer..i really enjoy your videos...iPls can I know the software you used in doing this?..thanks

  • @thangminlenhaokip4932
    @thangminlenhaokip4932 Год назад +1

    Please make video the best way to mix 1bag of cement and sand

  • @jayareddy6252
    @jayareddy6252 Год назад

    Easy understanding method. Jayachandra reddy.

  • @sharifulislam-cm1xj
    @sharifulislam-cm1xj 2 года назад +1

    Tnx

  • @Twitchtv_zh-tw
    @Twitchtv_zh-tw Год назад +1

    還有一個是筋的間距 在地震帶都比較窄 10~15cm

  • @jayareddy6252
    @jayareddy6252 Год назад

    Nice explanation. Thanks .jayachandrareddy.

  • @qayoumkhan470
    @qayoumkhan470 Год назад

    Sir muji circular colomn me Aria chahia liking bottom 27inch hai sir top 18inch

  • @pigikprasatko1253
    @pigikprasatko1253 Год назад +7

    Conection of rebar in column you have incorect. You may joint this with double welded rebars from both sides and conected rebar insert to the edge. Your solution produce parazitical bending moments

  • @sanjaymahadik9943
    @sanjaymahadik9943 Год назад +1

    Please do same animation for beam & slab
    Thanks for your animation video

  • @Sarosh9696
    @Sarosh9696 2 года назад

    Up to what distance the ties spacing should be close ? Is it H/3 ?

  • @hossainzargham2190
    @hossainzargham2190 2 года назад +1

    Thanks alot dear

  • @smartsv4727
    @smartsv4727 Год назад +1

    Wich software sir

  • @prabum5523
    @prabum5523 Год назад

    Sir, please give steel details 60×40 marriage hall .G+1 40 feet side no column.

  • @victorpetchenev4119
    @victorpetchenev4119 2 года назад +2

    8:26 да такие ломы только на завода можно погнуть!

  • @johnrogan9420
    @johnrogan9420 2 года назад +1

    Inside baseball column making!...well ✔

  • @luisalbertoariasmuriel7959
    @luisalbertoariasmuriel7959 Год назад

    Bien si se entiende 50 por ciento de empalme con refuerzo de estribos cercanos okey.

  • @rayzincrothravenwood1510
    @rayzincrothravenwood1510 2 года назад +1

    @9:14 you award bell for a correct column but the braces do not have the 135° bend in them

  • @user-rb2np5dt3l
    @user-rb2np5dt3l 2 года назад +2

    Please, what is the name of the application you draw with? ☺️

  • @mc.drawing6255
    @mc.drawing6255 Год назад +1

    👌😊👍👍

  • @raymondpapang3854
    @raymondpapang3854 Год назад

    From me..
    my Common sense the best lap join in Column is under Tide Bean..30 cm above 20 cm..,
    whatever ground floor or first floor..Not in the middle of column..
    Because when it's comes Desater../ meanly Earthquake, construction are not safety it's can collapse

  • @rbcastro5727
    @rbcastro5727 3 года назад +2

    Se dice que las varillas de unión deben llegar hasta el suelo y no flotando como esas.

  • @UMASHANKAR-jz9hs
    @UMASHANKAR-jz9hs Год назад +1

    bigger dia rod crank not possible.

  • @duketran62
    @duketran62 3 года назад +2

    @2:01, on the right column, what are the angle and length of bent rebars? Also what is the minimum overlap size of the 2 bars pink and black? Thanks

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  3 года назад +2

      Thanks for your question. The slope (angle) is 1:6 and the length is 30d . And the minimum size of 2 bars overlap is 12mm diameter

    • @medaprasanth
      @medaprasanth 2 года назад +1

      @@NHAXANHVIETNAM 30d development length is per which code?
      It should be around 50d for M30 grade concrete and Fe500 rebar

    • @mihailfelixdumitresc
      @mihailfelixdumitresc Год назад

      ​​@@NHAXANHVIETNAM The overlapping in my country, where buildings are designed to presumably withstand 8 degrees on the Richter scale, is between 50-60 times the diameter of the rebars.

  • @architecture-gawangkalidad4543
    @architecture-gawangkalidad4543 Год назад +1

    What code is your reference.thanms

  • @taffythegreat1986
    @taffythegreat1986 Год назад +1

    Hmmm everything I’ve done is wrong. What a bummer 😂

  • @kizzjd9578
    @kizzjd9578 2 года назад +2

    Your lateral ties at 135° are alternating sides every run yet if what you’re saying for everything else, they should be changing every 90° instead of 180°.

    • @dominicnolan6975
      @dominicnolan6975 2 года назад +1

      This works for square stirrups but rectangular ones have to be 180°, obviously.

    • @kizzjd9578
      @kizzjd9578 2 года назад

      @@dominicnolan6975 yep.. but these are square.

  • @mohammadmehroz6102
    @mohammadmehroz6102 5 дней назад

    What is the music name??

  • @abdulganisurve4591
    @abdulganisurve4591 2 года назад +1

    Please guide how to make sweeming pool construction.

  • @AdamAdam-fh1jj
    @AdamAdam-fh1jj 2 года назад +1

    Why you give the joggle ?

  • @mitramoradi3846
    @mitramoradi3846 3 года назад

    به این نوع م میلگرد که خم داره واسه اتصال پایه ستون چی هست

  • @hasyem7009
    @hasyem7009 3 года назад

    Bikin lebih banyak

  • @vi683a
    @vi683a 3 месяца назад +1

    9:13 is a not good!
    No 135 degree bends

  • @JosephAlexanderR.
    @JosephAlexanderR. 9 дней назад

    I thought this was a revit tutorial into how to make reinforcements.

  • @curiosityu9359
    @curiosityu9359 2 года назад +2

    It is so fast 🚴三

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  2 года назад

      Thank for your opinion

    • @kentmate645
      @kentmate645 2 года назад

      @@NHAXANHVIETNAM I watched it at 0.25 speed! I've never done that before.

  • @anthony7091
    @anthony7091 Год назад +1

    Interesting.
    For 200mmX200mm concrete columns, what size should the ties be?

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  Год назад +1

      The ties should be 6-8mm sir

    • @anthony7091
      @anthony7091 Год назад

      @@NHAXANHVIETNAM thanks
      What l meant was square size. 150mmX150mm or 100mmX100mm?

  • @kollurubharathsimha539
    @kollurubharathsimha539 2 года назад +1

    Bro give time to even look at it

  • @samaddengineering798
    @samaddengineering798 Год назад +2

    Not correct overlap of two drawings

  • @juanpack8146
    @juanpack8146 2 года назад +2

    But it's really difficult to tell a old worker when his pride and ego at stake😆

    • @NHAXANHVIETNAM
      @NHAXANHVIETNAM  2 года назад

      Haha

    • @marcinkazberuk4923
      @marcinkazberuk4923 2 года назад

      Especcially, if your knowledge isn't perfect like informations on this video. Both types are incorrect.

  • @lovetodrive3421
    @lovetodrive3421 2 года назад +1

    Bohot jaldi kr rha he bhai thoda dhire

  • @MaMa-ig2hh
    @MaMa-ig2hh 10 месяцев назад

    Nonsense, simply weld the iron and make an extension. Important places such as in thin columns, the bearing beams should be treated with an anti-corrosion agent. Certainly our modern primitive way of building is far behind the ancient buildings. It has a service life until the steel wears out.

  • @mikeangami3714
    @mikeangami3714 6 месяцев назад

    Watch video in 4X

  • @Black--general
    @Black--general 2 года назад +4

    Это только на бумаге и в 3д красиво смотрится и легко реализуется!
    А на практике это проблематично реализовать, так что это все глупости!

    • @user-xp9ts1wq4q
      @user-xp9ts1wq4q 2 года назад

      тоже трудно было представить, как рабочие так аккуратно согнут стержень д12 или 16 (а то и 22мм) чтобы у оного получился такой грамотный переход в 45гр, да еще и с возвратом к основной оси)

    • @marcinkazberuk4923
      @marcinkazberuk4923 2 года назад

      @@user-xp9ts1wq4q :-) do it with machines and it will be easier ;-)

    • @Black--general
      @Black--general 2 года назад

      @@marcinkazberuk4923 Ну тогда покажите этот аппарат для гибки арматуры!

    • @marcinkazberuk4923
      @marcinkazberuk4923 2 года назад

      @@Black--general are you joking? I can't print link on YT.

    • @Black--general
      @Black--general 2 года назад

      @@marcinkazberuk4923 Автор канала может ссылки оставлять тут)))