10 Basic Rules of Column Design - Don't Forget Basic Rules of RCC Column

Поделиться
HTML-код

Комментарии • 161

  • @romycruz4498
    @romycruz4498 3 года назад +3

    Thanks for sharing. -watching from the Philippines.

  • @shokatraja1832
    @shokatraja1832 2 года назад +1

    MashALLAH yr really dua ha apke lia

  • @kanagarajkanagaraj6775
    @kanagarajkanagaraj6775 Год назад +3

    I love your lecture, very helpful Sir.

  • @bossingsarmento8989
    @bossingsarmento8989 3 года назад +2

    I learned a lot from your video, good boy. Thank you sir

  • @mamadoudiop5462
    @mamadoudiop5462 2 года назад

    Great video, very academic. Thank you from Senegal

  • @MustaphaGoni-ru3op
    @MustaphaGoni-ru3op 8 месяцев назад

    Masha allah i really appreciate you Sir

  • @josephmasvokisi7745
    @josephmasvokisi7745 Год назад +1

    I like your teaching you are highly knowledgeable

  • @ForensicCats
    @ForensicCats 2 года назад +6

    Perhaps rule number 11, we should spray galvanized over all outer reinforcement, including stirrups or at least etch and nutrialize metal to point of ph concrete pH will not react as much...
    Then we could add number 12, use a coating to protect exposed columns from water intrusion.
    Keep up your good work, I have posting on this for years now...

    • @TheLazyGuyWay
      @TheLazyGuyWay Год назад

      Nothing not graded and recommended in engineering should be sprayed as he could alter chemicals contained in concrete mix. Minimum rebars cover is based on building area too. To prevent water intrusion especially in salted air area, we would use a different type of cement like type 2 portland ciment with c3a < 8% or even a type 5 portland ciment with c3a < 5% which is better.

  • @prafulsoni1095
    @prafulsoni1095 3 года назад

    Very useful RC column design rules.

  • @VicTv1992
    @VicTv1992 5 месяцев назад

    Thank you sir, for sharing your knowledge. I am learning from your lectures.God bless .❤

  • @zainalabidin6390
    @zainalabidin6390 3 года назад +1

    Alaikumussalam brother...thanks for your video..
    Very important for me..i like

  • @REG3305
    @REG3305 3 года назад +3

    TY sir! All the best!

  • @civilvibes8036
    @civilvibes8036 3 года назад +2

    thank you sir wonderful explanation keep it up

  • @ManneLearningAcademy
    @ManneLearningAcademy 3 года назад

    Nice presentation there sir. i learned a lot. Keep it up. More videos sir.

  • @hawk61192
    @hawk61192 3 года назад

    Very informative video brother. Very well explained.

  • @PBS-nm1uu
    @PBS-nm1uu Год назад

    best video i have seen so far, thanks

  • @hanadnor2457
    @hanadnor2457 4 года назад +3

    Maasha Allah.
    Thanks brother

  • @yabagabaduza
    @yabagabaduza 3 года назад +3

    Thank you for the education, I have a plot size 60 × 25 ft, I. Want to make one big shop without middle columns and to construct four storey residential houses on top, kindly advise how will I design the columns and beams. Thank you.

  • @adityaadityanarayana6862
    @adityaadityanarayana6862 4 года назад +1

    Good message brother 👍

  • @ayuubmohamedisxaaq2859
    @ayuubmohamedisxaaq2859 4 года назад

    God bless you
    Great teacher

  • @sawjulianku8136
    @sawjulianku8136 7 месяцев назад

    Thanks, I have been studying yr video n like it. Only a bit difficult in following yr accent.

  • @debendrabehera7626
    @debendrabehera7626 7 месяцев назад

    Sir,
    Can we construct 2 storey bulding with 4 nos. of 12mm rods in a column ?

  • @booksourexistence2153
    @booksourexistence2153 4 года назад +1

    Thanks a million sirji

  • @ahsanbinalrahmanfromairara9868
    @ahsanbinalrahmanfromairara9868 4 года назад

    Thanks Sir Ji
    Allah Bless You Sir Ji

  • @cliffriifiu1586
    @cliffriifiu1586 3 года назад

    I love your lecture, very helpful hope to get more information from you sir

  • @bayisabiri2450
    @bayisabiri2450 4 года назад +1

    Thank you, that's good

  • @mahaboobsubhani6758
    @mahaboobsubhani6758 2 года назад +1

    Sir
    What happensin colmn if concrete cover more than 25mm in rectangular column

  • @syedshabirgilani9944
    @syedshabirgilani9944 3 года назад +1

    Thanks .
    What should be the reinforcement ratio i;e steel qty.

  • @REANDESIGNSTRUCTURE
    @REANDESIGNSTRUCTURE Год назад

    Thanks for share knowlegde.

  • @kefelegntemesgen7958
    @kefelegntemesgen7958 3 года назад

    Good explanation!

  • @manojkumar-qu8ml
    @manojkumar-qu8ml 3 года назад +1

    I have planned to construct two separate rooms like 20*10 ( ground floor with 10*14 room size at first floor) & 22.5*10 (only ground floor) . My engineer suggested RCC is as follows. Pls tell it correct or not. Basement level of 22.5*10 is 2 feet less than 20*10 room
    1. For 20*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 8 feet at one end and 11 ft at other end. Plinth beam with 1.5 feet height and 9*9 (l*b). Ceiling height is 10 feet. Planned tie beam at below windows (2.5 feet) and lintel (7 feet) of 6 inch rcc
    2. For 22.5*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 10 feet at one end and 10 ft at other end. Plinth beam with 1 feet height and 9*9 (l*b). Ceiling height is 12 feet. Planned tie beam at below windows (4 feet) and lintel ( 8 feet) with 6 inch rcc
    And join the both room in ceiling and both room in 90 degree position to each other

  • @mjazz9017
    @mjazz9017 2 года назад

    Very informative 👍👍👍

  • @JahidulIslam-bf5qw
    @JahidulIslam-bf5qw 2 года назад

    Thank you sir, i am from Bangladesh

  • @anthonymarafi8160
    @anthonymarafi8160 Год назад

    Thank you for sharing.
    🙂👍

  • @P99665
    @P99665 Год назад

    Useful info thanks

  • @romycruz4498
    @romycruz4498 4 года назад

    Thanks again- from-Phils.

  • @abdumohammed6880
    @abdumohammed6880 3 года назад

    Hey sir ..is that safe if the depth of the beam less than that of the depth

  • @nagaraj5338
    @nagaraj5338 Год назад

    Very nice explanation and fabulous

  • @justinekihoro5152
    @justinekihoro5152 3 года назад

    I have learned a lot about building from u

  • @phyohtetkoko929
    @phyohtetkoko929 Год назад

    Thanks For Teaching SIr

  • @nizamali7027
    @nizamali7027 2 месяца назад

    Nice teaching

  • @joshuabautista9519
    @joshuabautista9519 3 года назад

    Thank you! So useful

  • @bsudheer05
    @bsudheer05 2 года назад

    Good explanation...

  • @osmanyussuf7069
    @osmanyussuf7069 Год назад

    Masha Allah thanks

  • @ziauddin7948
    @ziauddin7948 3 года назад

    Good civil engineering rules of column construction #

  • @user-lx4qm1gy7g
    @user-lx4qm1gy7g 9 месяцев назад

    How about 9meters span beam what should be the coulumn n beam

  • @aadil8715
    @aadil8715 2 года назад +1

    I was laughing the whole time, the accent , the spellings,hahhahah any way good one.

  • @dulhapur
    @dulhapur 2 года назад

    For finding A zone and B zone in coloumn only two floor beams are considered,is not lintel tie beam required to considered?

  • @muhammedtijani2308
    @muhammedtijani2308 Год назад

    Peace to you my Honurable Engr. Sir, thank you sir.

  • @cyrilthomasthomas6714
    @cyrilthomasthomas6714 Год назад +1

    Super sir

  • @bebotepuknot2631
    @bebotepuknot2631 3 года назад

    Rectangular column can be use 6 longotudinal bar?

  • @amitgehalot125
    @amitgehalot125 3 года назад

    Sir can we change orientation of one column at first floor

  • @ainunjariyaazad9179
    @ainunjariyaazad9179 4 года назад +6

    Thanks sir
    Please upload to how prepare bar bending schedule ?~~

  • @homendrapandey5708
    @homendrapandey5708 4 года назад

    thank you very much,

  • @simranratnani5923
    @simranratnani5923 3 года назад

    please make video on distance between two columns,grids and size of columns

  • @DeejayPapi
    @DeejayPapi 2 года назад

    🙏🏽❤amazing

  • @abdimajiddek7782
    @abdimajiddek7782 Год назад

    Thanks so much teacher

  • @charlesgregory7469
    @charlesgregory7469 Год назад

    Is there a height to cross section area ratio in columns?

  • @sagarsooriyakumar4542
    @sagarsooriyakumar4542 2 года назад

    sir,in your 5th rule you said about concrete cover. it means clear cover right. you are saying about effective cover, isnt it?. because effective cover is between top steel center to top edge distance. so concrete cover and effective cover same?

  • @ZaiidRaza
    @ZaiidRaza 4 года назад

    Sir apka wo Shadi ka coat nhi pehne apne?

  • @constructionmaster2642
    @constructionmaster2642 3 года назад +1

    How I know what is steel bar size is required for different colums for load bearing

  • @willfordnongspung6238
    @willfordnongspung6238 3 года назад

    Great sir but we hardly understand the third and fourth rules any way your explanation are of great help

  • @bijayalaxmipant9940
    @bijayalaxmipant9940 3 года назад

    Is it possible to build a building in a single column?

  • @ChoooooXiS
    @ChoooooXiS 3 года назад +1

    Sir, what is the required column and wall footing for 2-storey 5x5 residential house? Thanks.

  • @rajeshraj8106
    @rajeshraj8106 4 года назад

    Sir. How would we know the column is axial r eccentric?

  • @mahaboobsubhani6758
    @mahaboobsubhani6758 2 года назад +1

    Is clear cover not same around tie of column sir......u said 25 mm from top and bottom and >15 mm from side:....shall we take same or different..

  • @iamphyize
    @iamphyize 3 года назад

    nice one

  • @BigBuck6244
    @BigBuck6244 4 года назад +1

    Plz discuss Acceptance criteria of concrete as per Britesh Standard

  • @dinakadi6609
    @dinakadi6609 3 года назад

    Thank you very much

  • @gangmeiaphun5026
    @gangmeiaphun5026 Месяц назад

    why extra steel/rod are putting below in the L/2 portion of beam? please

  • @gayanpradeepkumara5557
    @gayanpradeepkumara5557 4 года назад

    Brother What happens if concrete cover less than 25mm...... ?

  • @gerardoatutubo4759
    @gerardoatutubo4759 4 года назад +2

    Sir, size of column plz....if G, G+1, or G+2 residential 4m span. Tnx.

  • @gopalkamble1263
    @gopalkamble1263 2 года назад +1

    Ties spacing in IS code maximum 300 mm

  • @uzmaonline4844
    @uzmaonline4844 3 года назад

    Nice bhai

  • @CR-io3xw
    @CR-io3xw 3 года назад

    Very interested your class sir

  • @ragibkhan2323
    @ragibkhan2323 4 года назад

    Sr can you explain about Circular column.

  • @AtomicHermit
    @AtomicHermit 2 года назад

    In 7 and 8 you may mean vertical rather than longitudinal?

  • @MuhammadAzam-oi2xg
    @MuhammadAzam-oi2xg 3 года назад

    Sir if load coming on 3 then size of coloum?

  • @BigBuck6244
    @BigBuck6244 4 года назад +1

    And Concrete Control Charts Discussed

  • @munaseid2765
    @munaseid2765 Год назад

    I didn't understand the first two rule how do we know when designing where the axial load would be to choose either square or rectangular column?

  • @jeevanchaudhary7222
    @jeevanchaudhary7222 3 года назад +1

    how we can know column is taking Axial or Eccentric load

  • @kartikshekhar940
    @kartikshekhar940 4 года назад +1

    Sir your video is very informative.
    1. Pl suggest the column width for a 25 ft X 44 ft plot (2 Storey Building) ? Is 12 “ X 12 “ enough with 8 Nos 12 mm bars ?
    2.Also pl suggest maximum spacing between 2 columns in the above mentioned structure?

    • @tslunzou6393
      @tslunzou6393 2 года назад

      max spacing of columns should not be more than 5.5 metres

  • @foodmates1994
    @foodmates1994 2 года назад

    Hi sir plz reply my question,my house only G[G+0], span between 2 columns length 19 feet ,wedth 14 feet , size of colum 9/15 with 6 bars of 16mm rectangler column, all house walls 9 “wall. And first we make walls before slab it is safe or not ? Plz reply

  • @nelsleons2931
    @nelsleons2931 3 года назад +1

    How about determining the axial load for column sizing?

    • @davidcivil1651
      @davidcivil1651 3 года назад

      Calc the load transferring from slab to beams and from beams to column.

  • @wefindwaystodothat6431
    @wefindwaystodothat6431 2 года назад

    what is minimum Beam size if 5x5 meter support column residential Building.

  • @guyesanoor-son940
    @guyesanoor-son940 3 года назад

    Good lecture sir.👍👌🏼
    Is it possible to renovate a mud house with reinforced bars without demolishing the entire house?

    • @6ear_rsa
      @6ear_rsa 3 года назад

      It is but putting the existing out building in grave danger from settlement.

  • @MuhammadAfzal-ok1ip
    @MuhammadAfzal-ok1ip 3 года назад

    What is pullers with 6 bars use like a shop covered area is 984 sq ft 1floor and 2 floor is 835+ 835 sq fts

  • @ragibkhan2323
    @ragibkhan2323 4 года назад

    👍🏼

  • @maxizmax484
    @maxizmax484 9 месяцев назад

    You didn’t Mention the main thing that hock of a tie should be curved 135° Angel. 😊

  • @jnyanendrakumarjena4354
    @jnyanendrakumarjena4354 4 года назад

    Thanks.

  • @srinivasandk9680
    @srinivasandk9680 3 года назад

    excelant sir but more advertisments coming in short times . thank u.

  • @ayoubenaciri
    @ayoubenaciri 3 года назад

    👍👍👍

  • @luckynoob3328
    @luckynoob3328 10 месяцев назад

    Thank you sir

  • @pattaharsha2220
    @pattaharsha2220 4 года назад

    Where the laplength should be provided in column.....?

  • @harishXO
    @harishXO 4 года назад +4

    Sir how would we know that load is on centre or eccentric?

    • @veerababuakula1344
      @veerababuakula1344 4 года назад +1

      Eccentric means the load is not passing through the centre and it passes at some distance from the centre

    • @kiyoponnn
      @kiyoponnn 3 года назад

      @@veerababuakula1344 Moron.

  • @mackybishmac8559
    @mackybishmac8559 2 года назад

    Please sir I would like to build a two storehouse only and coloum can this be done

  • @SurajChauhan-qh7bh
    @SurajChauhan-qh7bh 3 года назад

    THANKS SIR

  • @petergrice76
    @petergrice76 4 года назад +1

    15mm cover and 20mm aggregate ?????

  • @indianarchitecture
    @indianarchitecture 3 года назад

    ♥️♥️♥️

  • @adhivamshi2154
    @adhivamshi2154 2 года назад

    How to do cost estimation for Foundations