How to Choose a Sump Pump? (Complete Sizing Guide) | Spec. Sense

Поделиться
HTML-код
  • Опубликовано: 20 сен 2024

Комментарии • 18

  • @jenniferkwapisz4694
    @jenniferkwapisz4694 4 года назад

    Thank you so MUCH! IM 43 ANDD my mom is 80 n I have an 11 yr old. We both are widows n I am care taker. Thankfully and gratefully my father taught me the same as my brother. I am mechanically inclined and knowwledgable. I have assisted replacing these solo pumps but never done one alone. Your video helped me learn info I needed to know b4 I left house to purchase a new pump and helped me install new pump and also a tank alert and a battery back up pump instead of manuel one. VERY INFORMATIVE. If only it wasn't in a hole and in nice clear glass tank! Lol Excellent videos. Highly revommended!

    • @AmreSupply
      @AmreSupply  4 года назад +1

      Thank you Janice! It really means a lot to hear that. We put a lot of thought into making our videos informative and practical, and its great to hear that the videos have helped you out!
      Its great that your father helped you to become mechanically inclined. Being comfortable learning and doing these repairs really helps keep people grounded. We're happy to have helped you replace your sump pump and upgrades!

    • @jenniferkwapisz4694
      @jenniferkwapisz4694 4 года назад

      @@AmreSupply Thanks to you we gave a new sump pump, central valve AND a battery back up pump. Your incredible video gave me confidence to install them all! And next time it goes it's gonna blast a horn so the whole block can hear it! Lol I most definitely will be watching more! Thank you from 3 very happy ladies!

    • @AmreSupply
      @AmreSupply  4 года назад +1

      @@jenniferkwapisz4694 That is wonderful! We really do love hearing experiences like yours and we hope the next video you watch is just as useful!

  • @Whatisthis195
    @Whatisthis195 Год назад

    Glad I found your video! We have an 18” basin that fills with water like clockwork every 10 minutes. Most I’ve ever seen between cycles is about 20 minutes. Dry, wet, doesn’t matter. Constant water flow into the basin. Would this require a higher HP pump, our current one burned out in about a year. -also, definitely not the check valve as I can see the water empty into the ditch!

    • @AmreSupply
      @AmreSupply  Год назад +1

      Thanks for watching. Yes it's likely that the ground water table or drainage is different than the average home. Check to make sure that discharge pipe is positioned in a way that it won't just drain back to the foundation, this might increase how much water is accumulating. It might not be a lot of new water it could largely be some of the same water draining back.
      A larger pump can help. You might want to invest in a backup system to make sure that the sump can always run. In your case it seems like a faulty pump even for a short while would result in a flood.

  • @michelekm56
    @michelekm56 8 месяцев назад

    Well-done video. Clear & efficient. Thank you.

    • @AmreSupply
      @AmreSupply  7 месяцев назад

      Glad it was helpful!

  • @23youwatch
    @23youwatch 6 дней назад

    Great videos

    • @AmreSupply
      @AmreSupply  4 дня назад

      Thank you, we're just happy to help!

  • @Ricquisimo
    @Ricquisimo 8 дней назад

    How about horizontal length of pipe to discharge point?

    • @AmreSupply
      @AmreSupply  7 дней назад

      Thanks for watching. A longer run of horizontal pipe will increase friction so that is a factor when making a more detailed calculation of total dynamic head.

  • @oparajiozioma2383
    @oparajiozioma2383 Год назад

    What could be the cause of four sewage pumps packing up at the same time in the same sump?

    • @AmreSupply
      @AmreSupply  Год назад

      Thanks for watching. It is unlikely that 4 pumps had all 4 motors fail at the same time. It is more likely that there is an issue with the power supply to the pumps.

  • @charlieeaton598
    @charlieeaton598 4 года назад

    Hi Vance - Thanks for your series - I live on a sailboat and have a 2,000 gph in my engine room, and another amid ships. The head is a little over a meter & 1/2, no checkvalve between, none really needed. does the head height vary depending on the hose diameter? I'm thinking it has to. Yeah?

    • @AmreSupply
      @AmreSupply  4 года назад

      Thank you Tom, we're glad you're finding the series helpful! The head will differ based on the hose diameter, so its best to use the same diameter as the outlet of the sump pump if possible. At 1.5 meters you won't get too much head loss from the height alone, and without a check valve or too many 90° turns, your pump should be able to output close the max gpm.

  • @LAArt
    @LAArt 4 года назад

    What's better - bottom inlet or side inlet?

    • @AmreSupply
      @AmreSupply  4 года назад

      Thanks for watching. Most sump basins will have a inlet pipe on the side near the top, and most sump pumps have a bottom intake which will mean it will have a lower water level after it discharges.